keyence Stock Image
Keyence SJ-H084C Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H084C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

840 mm 33.07" *4

No. ofelectrodes

12

Static elimination bar length

800 mm 31.50"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

980 g 34.57 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H108 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H108

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1080 mm 42.52" *3

No. ofelectrodes

24

Static elimination bar length

1040 mm 40.94"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1250 g 44.09 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H108A Keyence
Sale price 19,372.00 kr
Only 7 units left

Specifications

Model

SJ-H108A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1080 mm 42.52" *3

No. ofelectrodes

16

Static elimination bar length

1040 mm 40.94"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1200 g 42.33 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H108C Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H108C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

1080 mm 42.52" *4

No. ofelectrodes

16

Static elimination bar length

1040 mm 40.94"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

1200 g 42.33 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H132 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H132

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1320 mm 51.97" *3

No. ofelectrodes

30

Static elimination bar length

1280 mm 50.39"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1450 g 51.15 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H132A Keyence
Sale price 16,525.00 kr
Only 2 units left

Specifications

Model

SJ-H132A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1320 mm 51.97" *3

No. ofelectrodes

20

Static elimination bar length

1280 mm 50.39"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1400 g 49.38 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H132C Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H132C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

1320 mm 51.97" *4

No. ofelectrodes

20

Static elimination bar length

1280 mm 50.39"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

1400 g 49.38 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H156 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H156

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1560 mm 61.42" *3

No. ofelectrodes

36

Static elimination bar length

1520 mm 59.84"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1600 g 56.44 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

Keyence Stock Image
Keyence SJ-H156A Keyence
Sale price 28,110.00 kr
Only 2 units left

Specifications

Model

SJ-H156A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1560 mm 61.42" *3

No. ofelectrodes

24

Static elimination bar length

1520 mm 59.84"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1550 g 54.67 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H156C Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H156C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

1560 mm 61.42" *4

No. ofelectrodes

24

Static elimination bar length

1520 mm 59.84"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

1550 g 54.67 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H180 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H180

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1800 mm 70.87" *3

No. ofelectrodes

42

Static elimination bar length

1760 mm 69.29"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1850 g 65.26 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H180A Keyence
Sale price 11,164.00 kr
Only 1 unit left

Specifications

Model

SJ-H180A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1800 mm 70.87" *3

No. ofelectrodes

28

Static elimination bar length

1760 mm 69.29"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1750 g 61.73 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H180C Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H180C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

1800 mm 70.87" *4

No. ofelectrodes

28

Static elimination bar length

1760 mm 69.29"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

1750 g 61.73 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H204 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H204

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

2040 mm 80.31" *3

No. ofelectrodes

48

Static elimination bar length

2000 mm 78.74"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

2100 g 74.08 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H204A Keyence
Sale price 16,254.00 kr
Only 1 unit left

Specifications

Model

SJ-H204A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

2040 mm 80.31" *3

No. ofelectrodes

32

Static elimination bar length

2000 mm 78.74"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

2000 g 70.55 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H204C Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H204C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

2040 mm 80.31" *4

No. ofelectrodes

32

Static elimination bar length

2000 mm 78.74"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

2000 g 70.55 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H228 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H228

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

2280 mm 89.76" *3

No. ofelectrodes

54

Static elimination bar length

2240 mm 88.19"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

2400 g 84.66 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H228A Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H228A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

2280 mm 89.76" *3

No. ofelectrodes

36

Static elimination bar length

2240 mm 88.19"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

2350 g 82.89 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H228C Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H228C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

2280 mm 89.76" *4

No. ofelectrodes

36

Static elimination bar length

2240 mm 88.19"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

2350 g 82.89 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H252 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H252

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

2520 mm 99.21" *3

No. ofelectrodes

60

Static elimination bar length

2480 mm 97.64"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

2800 g 98.77 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H252A Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H252A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

2520 mm 99.21" *3

No. ofelectrodes

40

Static elimination bar length

2480 mm 97.64"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

2700 g 95.24 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H252C Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H252C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

2520 mm 99.21" *4

No. ofelectrodes

40

Static elimination bar length

2480 mm 97.64"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

2700 g 95.24 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H300 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SJ-H300

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

3000 mm 118.11" *3

No. ofelectrodes

72

Static elimination bar length

2960 mm 116.54"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

3250 g 114.64 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H300A Keyence
Sale price 9,110.00 kr
Only 1 unit left

Specifications

Model

SJ-H300A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

3000 mm 118.11" *3

No. ofelectrodes

48

Static elimination bar length

2960 mm 116.54"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

3150 g 111.11 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

Recently viewed