ABB

16438 products

Showing 265 - 288 of 16438 products

Showing 265 - 288 of 16438 products
View
1MRK002136-A ABB
ABB 1MRK002136-A ABB
Sale price0.00 kr
Sold Out

Package of contact sockets 10A, 100 pcs

ABB Stock Image
ABB 1MRK002247-AGR01 ABB
Sale price 20,828.00 kr
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

ABB Stock Image
ABB 1MRK002247-AGR02 ABB
Sale price 22,290.00 kr
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

ABB Stock Image
ABB 1MRK002812-AA ABB
Sale price0.00 kr
Sold Out

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

ABB Stock Image
ABB 1MRK004810-AC ABB
Sale price 83,660.00 kr
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

ABB Stock Image
ABB 1MRK004812-DC ABB
Sale price 70,617.00 kr
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

ABB Stock Image
ABB 1MRK004814-AC ABB
Sale price 108,952.00 kr
Only 6 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

ABB Stock Image
ABB 1MRK006516-AD ABB
Sale price0.00 kr
Sold Out

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

ABB Stock Image
ABB 1MRK006520-AD ABB
Sale price 89,496.00 kr
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

1MRS050396 ABB
ABB 1MRS050396 ABB
Sale price 40,861.00 kr
Only 2 units left

Central processor unit

1MRS050628 ABB - PS1_240V_HIGH
ABB 1MRS050628 ABB - PS1_240V_HIGH
Sale price 6,923.00 kr
Only 1 unit left

PS1_240V_HIGH - Power supply

1MRS050696 ABB
ABB 1MRS050696 ABB
Sale price0.00 kr
Sold Out

RAISING FRAME 50MM

1MRS050942 ABB
ABB 1MRS050942 ABB
Sale price0.00 kr
Sold Out

COMMUNICATION CABLE

1SAE231111R0104 ABB - ESB25-04N-01
ABB 1SAE231111R0104 ABB - ESB25-04N-01
Sale price0.00 kr
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080

Popular Downloads

EPLAN Data:
Data Sheet, Technical Information:

Dimensions

Product Net Width:
36 mm
Product Net Depth / Length:
65 mm
Product Net Height:
85 mm
Product Net Weight:
0.245 kg

Technical

Number of Main Contacts NO:
0
Number of Main Contacts NC:
4
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
4P
Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Rated Operational Voltage:
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated Operational Current AC-1 (Ie):
(NC) 25 A
Rated Operational Current AC-3 (Ie):
(230 V) Single Phase, NC 6 A
Rated Operational Current AC-7a (Ie):
(NC) 25 A
Rated Operational Current AC-7b (Ie):
(400 V) Three Phase, NC 6 A
Rated Operational Power AC-1 (Pe):
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.3 kW
Rated Operational Power AC-3 (Pe):
(230 V) Single Phase, NC 0.9 kW
(400 V) Three Phase, NC 2.7 kW
(230 V) Single Phase, NC 0.9 kW
(400 V) Three Phase, NC 2.7 kW
Rated Operational Power AC-7a (Pe):
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.25 kW
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.25 kW
Rated Operational Power AC-7b (Pe):
(230 V) Single Phase, NC 2.7 kW
(400 V) Three Phase, NC 2.7 kW
(230 V) Single Phase, NC 2.7 kW
(400 V) Three Phase, NC 2.7 kW
Rated Breaking Capacity AC-3:
8 x Ie / AC-3
Rated Making Capacity AC-3:
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui):
500 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Electrical Durability:
AC-1 (NC) 50000 cycle
AC-3 (NC) 340000 cycle
AC-7a (NC) 50000 cycle
AC-7b (NC) 340000 cycle
AC-1 (NC) 50000 cycle
AC-3 (NC) 340000 cycle
AC-7a (NC) 50000 cycle
AC-7b (NC) 340000 cycle
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Mechanical Durability:
Nr. Operations 1000000 cycle
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
24 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 2 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
Degree of Protection:
IP20
Recommended Screw Driver:
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Tightening Torque:
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Terminal Type:
Screw Terminals
Width in Number of Modular Spacings:
2.0
Product Name:
Installation Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 480 V AC
General Use Rating UL/CSA:
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
Horsepower Rating UL/CSA:
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Three Phase, NC 3 Hp
(440 ... 480 V AC) Single Phase, NC 0.5 Hp
(440 ... 480 V AC) Three Phase, NC 2 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Three Phase, NC 3 Hp
(440 ... 480 V AC) Single Phase, NC 0.5 Hp
(440 ... 480 V AC) Three Phase, NC 2 Hp
Connecting Capacity Main Circuit UL/CSA:
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Connecting Capacity Control Circuit UL/CSA:
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Tightening Torque UL/CSA:
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Full Load Amps Motor Use:
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Three Phase, NC 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Three Phase, NC 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Three Phase, NC 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Three Phase, NC 7.6 A

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 15g
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Consumer
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Certificates and Declarations

EAC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
39 mm
Package Level 1 Height:
69.5 mm
Package Level 1 Gross Weight:
0.245 kg
Package Level 1 EAN:
4013614523915
Package Level 2 Units:
48 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
12.3 kg
Package Level 2 EAN:
4013614538315

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC001653 - Installation contactor for distribution board
ETIM 8:
EC001653 - Installation contactor for distribution board
ETIM 9:
EC001653 - Installation contactor for distribution board
eClass:
V11.0 : 27142308
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4759 >> Installation contactor for distribution board
E-Number (Finland):
3707572
E-Number (Norway):
4190252
E-Number (Sweden):
3210562
1SAE231111R0113 ABB - ESB25-13N-01
ABB 1SAE231111R0113 ABB - ESB25-13N-01
Sale price0.00 kr
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080

Popular Downloads

EPLAN Data:
Data Sheet, Technical Information:

Dimensions

Product Net Width:
36 mm
Product Net Depth / Length:
65 mm
Product Net Height:
85 mm
Product Net Weight:
0.245 kg

Technical

Number of Main Contacts NO:
1
Number of Main Contacts NC:
3
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
4P
Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Rated Operational Voltage:
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated Operational Current AC-1 (Ie):
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
Rated Operational Current AC-3 (Ie):
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NC 6 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NC 6 A
Rated Operational Current AC-7a (Ie):
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
Rated Operational Current AC-7b (Ie):
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NC 6 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NC 6 A
Rated Operational Power AC-1 (Pe):
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.3 kW
(230 V) Single Phase, NO 5.8 kW
Rated Operational Power AC-3 (Pe):
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NC 2.7 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NC 2.7 kW
Rated Operational Power AC-7a (Pe):
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NC 17.25 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NC 17.25 kW
Rated Operational Power AC-7b (Pe):
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NC 2.7 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NC 2.7 kW
Rated Breaking Capacity AC-3:
8 x Ie / AC-3
Rated Making Capacity AC-3:
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui):
500 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Electrical Durability:
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Mechanical Durability:
Nr. Operations 1000000 cycle
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
24 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 2 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
Degree of Protection:
IP20
Recommended Screw Driver:
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Tightening Torque:
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Terminal Type:
Screw Terminals
Width in Number of Modular Spacings:
2.0
Product Name:
Installation Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 480 V AC
General Use Rating UL/CSA:
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
Horsepower Rating UL/CSA:
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NC 3 Hp
(440 ... 480 V AC) Single Phase, NC 0.5 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NC 2 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NC 3 Hp
(440 ... 480 V AC) Single Phase, NC 0.5 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NC 2 Hp
Connecting Capacity Main Circuit UL/CSA:
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Connecting Capacity Control Circuit UL/CSA:
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Tightening Torque UL/CSA:
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Full Load Amps Motor Use:
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NC 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NC 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NC 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NC 7.6 A

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 15g
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Consumer
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Certificates and Declarations

EAC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
39 mm
Package Level 1 Height:
69.5 mm
Package Level 1 Gross Weight:
0.245 kg
Package Level 1 EAN:
4013614523922
Package Level 2 Units:
48 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
12.3 kg
Package Level 2 EAN:
4013614538322

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC001653 - Installation contactor for distribution board
ETIM 8:
EC001653 - Installation contactor for distribution board
ETIM 9:
EC001653 - Installation contactor for distribution board
eClass:
V11.0 : 27142308
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4759 >> Installation contactor for distribution board
E-Number (Finland):
3707578
1SAE231111R0120 ABB - ESB25-20N-01
ABB 1SAE231111R0120 ABB - ESB25-20N-01
Sale price0.00 kr
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080

Popular Downloads

EPLAN Data:
Data Sheet, Technical Information:

Dimensions

Product Net Width:
36 mm
Product Net Depth / Length:
65 mm
Product Net Height:
85 mm
Product Net Weight:
0.23 kg

Technical

Number of Main Contacts NO:
2
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
2P
Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Rated Operational Voltage:
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated Operational Current AC-1 (Ie):
(NO) 25 A
Rated Operational Current AC-3 (Ie):
(230 V) Single Phase, NO 9 A
Rated Operational Current AC-7a (Ie):
(NO) 25 A
Rated Operational Current AC-7b (Ie):
(230 V) Single Phase, NO 9 A
Rated Operational Power AC-1 (Pe):
(230 V) Single Phase, NO 5.8 kW
Rated Operational Power AC-3 (Pe):
(230 V) Single Phase, NO 1.3 kW
Rated Operational Power AC-7a (Pe):
(230 V) Single Phase, NO 5.8 kW
Rated Operational Power AC-7b (Pe):
(230 V) Single Phase, NO 1.3 kW
Rated Breaking Capacity AC-3:
8 x Ie / AC-3
Rated Making Capacity AC-3:
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui):
500 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Electrical Durability:
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Mechanical Durability:
Nr. Operations 1000000 cycle
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
24 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 2 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
Degree of Protection:
IP20
Recommended Screw Driver:
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Tightening Torque:
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Terminal Type:
Screw Terminals
Width in Number of Modular Spacings:
2.0
Product Name:
Installation Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 480 V AC
General Use Rating UL/CSA:
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
Horsepower Rating UL/CSA:
(220 ... 240 V AC) Single Phase, NO 1 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
Connecting Capacity Main Circuit UL/CSA:
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Connecting Capacity Control Circuit UL/CSA:
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Tightening Torque UL/CSA:
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Full Load Amps Motor Use:
(220 ... 240 V AC) Single Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 15g
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Consumer
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Certificates and Declarations

EAC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
39 mm
Package Level 1 Height:
69.5 mm
Package Level 1 Gross Weight:
0.23 kg
Package Level 1 EAN:
4013614523939
Package Level 2 Units:
48 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
11.5 kg
Package Level 2 EAN:
4013614538339

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC001653 - Installation contactor for distribution board
ETIM 8:
EC001653 - Installation contactor for distribution board
ETIM 9:
EC001653 - Installation contactor for distribution board
eClass:
V11.0 : 27142308
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4759 >> Installation contactor for distribution board
E-Number (Norway):
4190263
1SAE231111R0122 ABB - ESB25-22N-01
ABB 1SAE231111R0122 ABB - ESB25-22N-01
Sale price0.00 kr
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080

Popular Downloads

EPLAN Data:
Data Sheet, Technical Information:

Dimensions

Product Net Width:
36 mm
Product Net Depth / Length:
65 mm
Product Net Height:
85 mm
Product Net Weight:
0.245 kg

Technical

Number of Main Contacts NO:
2
Number of Main Contacts NC:
2
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
4P
Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Rated Operational Voltage:
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated Operational Current AC-1 (Ie):
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
Rated Operational Current AC-3 (Ie):
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
Rated Operational Current AC-7a (Ie):
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
Rated Operational Current AC-7b (Ie):
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
Rated Operational Power AC-1 (Pe):
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
Rated Operational Power AC-3 (Pe):
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
Rated Operational Power AC-7a (Pe):
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
Rated Operational Power AC-7b (Pe):
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
Rated Breaking Capacity AC-3:
8 x Ie / AC-3
Rated Making Capacity AC-3:
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui):
500 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Electrical Durability:
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Mechanical Durability:
Nr. Operations 1000000 cycle
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
24 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 2 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
Degree of Protection:
IP20
Recommended Screw Driver:
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Tightening Torque:
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Terminal Type:
Screw Terminals
Width in Number of Modular Spacings:
2.0
Product Name:
Installation Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 480 V AC
General Use Rating UL/CSA:
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
Horsepower Rating UL/CSA:
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
Connecting Capacity Main Circuit UL/CSA:
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Connecting Capacity Control Circuit UL/CSA:
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Tightening Torque UL/CSA:
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Full Load Amps Motor Use:
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 15g
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Consumer
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Certificates and Declarations

EAC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
39 mm
Package Level 1 Height:
69.5 mm
Package Level 1 Gross Weight:
0.245 kg
Package Level 1 EAN:
4013614523946
Package Level 2 Units:
48 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
12.3 kg
Package Level 2 EAN:
4013614538346

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC001653 - Installation contactor for distribution board
ETIM 8:
EC001653 - Installation contactor for distribution board
ETIM 9:
EC001653 - Installation contactor for distribution board
eClass:
V11.0 : 27142308
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4759 >> Installation contactor for distribution board
E-Number (Finland):
3707574
E-Number (Norway):
4190257
E-Number (Sweden):
3210564
1SAE231111R0131 ABB - ESB25-31N-01
ABB 1SAE231111R0131 ABB - ESB25-31N-01
Sale price0.00 kr
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080

Popular Downloads

EPLAN Data:
Data Sheet, Technical Information:

Dimensions

Product Net Width:
36 mm
Product Net Depth / Length:
65 mm
Product Net Height:
85 mm
Product Net Weight:
0.245 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
1
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
4P
Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Rated Operational Voltage:
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated Operational Current AC-1 (Ie):
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
Rated Operational Current AC-3 (Ie):
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
Rated Operational Current AC-7a (Ie):
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
Rated Operational Current AC-7b (Ie):
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
Rated Operational Power AC-1 (Pe):
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
Rated Operational Power AC-3 (Pe):
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
Rated Operational Power AC-7a (Pe):
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
Rated Operational Power AC-7b (Pe):
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
Rated Breaking Capacity AC-3:
8 x Ie / AC-3
Rated Making Capacity AC-3:
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui):
500 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Electrical Durability:
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Mechanical Durability:
Nr. Operations 1000000 cycle
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
24 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 2 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
Degree of Protection:
IP20
Recommended Screw Driver:
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Tightening Torque:
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Terminal Type:
Screw Terminals
Width in Number of Modular Spacings:
2.0
Product Name:
Installation Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 480 V AC
General Use Rating UL/CSA:
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
Horsepower Rating UL/CSA:
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
Connecting Capacity Main Circuit UL/CSA:
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Connecting Capacity Control Circuit UL/CSA:
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Tightening Torque UL/CSA:
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Full Load Amps Motor Use:
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 15g
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Consumer
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Certificates and Declarations

EAC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
39 mm
Package Level 1 Height:
69.5 mm
Package Level 1 Gross Weight:
0.245 kg
Package Level 1 EAN:
4013614523960
Package Level 2 Units:
48 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
12.3 kg
Package Level 2 EAN:
4013614538360

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC001653 - Installation contactor for distribution board
ETIM 8:
EC001653 - Installation contactor for distribution board
ETIM 9:
EC001653 - Installation contactor for distribution board
eClass:
V11.0 : 27142308
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4759 >> Installation contactor for distribution board
E-Number (Finland):
3707576
E-Number (Norway):
4190265
E-Number (Sweden):
3210566
1SAE231111R0140 ABB - ESB25-40N-01
ABB 1SAE231111R0140 ABB - ESB25-40N-01
Sale price0.00 kr
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080

Popular Downloads

EPLAN Data:
Data Sheet, Technical Information:

Dimensions

Product Net Width:
36 mm
Product Net Depth / Length:
65 mm
Product Net Height:
85 mm
Product Net Weight:
0.245 kg

Technical

Number of Main Contacts NO:
4
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
4P
Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Rated Operational Voltage:
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated Operational Current AC-1 (Ie):
(NO) 25 A
Rated Operational Current AC-3 (Ie):
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
Rated Operational Current AC-7a (Ie):
(NO) 25 A
Rated Operational Current AC-7b (Ie):
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
Rated Operational Power AC-1 (Pe):
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
Rated Operational Power AC-3 (Pe):
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
Rated Operational Power AC-7a (Pe):
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
Rated Operational Power AC-7b (Pe):
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
Rated Breaking Capacity AC-3:
8 x Ie / AC-3
Rated Making Capacity AC-3:
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui):
500 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Electrical Durability:
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Mechanical Durability:
Nr. Operations 1000000 cycle
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
24 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 2 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
Degree of Protection:
IP20
Recommended Screw Driver:
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Tightening Torque:
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Terminal Type:
Screw Terminals
Width in Number of Modular Spacings:
2.0
Product Name:
Installation Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 480 V AC
General Use Rating UL/CSA:
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
Horsepower Rating UL/CSA:
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
Connecting Capacity Main Circuit UL/CSA:
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Connecting Capacity Control Circuit UL/CSA:
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Tightening Torque UL/CSA:
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Full Load Amps Motor Use:
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 15g
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Consumer
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Certificates and Declarations

EAC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
39 mm
Package Level 1 Height:
69.5 mm
Package Level 1 Gross Weight:
0.245 kg
Package Level 1 EAN:
4013614523977
Package Level 2 Units:
48 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
12.3 kg
Package Level 2 EAN:
4013614538377

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC001653 - Installation contactor for distribution board
ETIM 8:
EC001653 - Installation contactor for distribution board
ETIM 9:
EC001653 - Installation contactor for distribution board
eClass:
V11.0 : 27142308
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4759 >> Installation contactor for distribution board
E-Number (Finland):
3707570
E-Number (Norway):
4190246
E-Number (Sweden):
3210559
1SAE231111R0204 ABB - ESB25-04N-02
ABB 1SAE231111R0204 ABB - ESB25-04N-02
Sale price0.00 kr
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080

Popular Downloads

EPLAN Data:
Data Sheet, Technical Information:

Dimensions

Product Net Width:
36 mm
Product Net Depth / Length:
65 mm
Product Net Height:
85 mm
Product Net Weight:
0.245 kg

Technical

Number of Main Contacts NO:
0
Number of Main Contacts NC:
4
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
4P
Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Rated Operational Voltage:
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated Operational Current AC-1 (Ie):
(NC) 25 A
Rated Operational Current AC-3 (Ie):
(230 V) Single Phase, NC 6 A
Rated Operational Current AC-7a (Ie):
(NC) 25 A
Rated Operational Current AC-7b (Ie):
(400 V) Three Phase, NC 6 A
Rated Operational Power AC-1 (Pe):
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.3 kW
Rated Operational Power AC-3 (Pe):
(230 V) Single Phase, NC 0.9 kW
(400 V) Three Phase, NC 2.7 kW
(230 V) Single Phase, NC 0.9 kW
(400 V) Three Phase, NC 2.7 kW
Rated Operational Power AC-7a (Pe):
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.25 kW
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.25 kW
Rated Operational Power AC-7b (Pe):
(230 V) Single Phase, NC 2.7 kW
(400 V) Three Phase, NC 2.7 kW
(230 V) Single Phase, NC 2.7 kW
(400 V) Three Phase, NC 2.7 kW
Rated Breaking Capacity AC-3:
8 x Ie / AC-3
Rated Making Capacity AC-3:
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui):
500 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Electrical Durability:
AC-1 (NC) 50000 cycle
AC-3 (NC) 340000 cycle
AC-7a (NC) 50000 cycle
AC-7b (NC) 340000 cycle
AC-1 (NC) 50000 cycle
AC-3 (NC) 340000 cycle
AC-7a (NC) 50000 cycle
AC-7b (NC) 340000 cycle
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Mechanical Durability:
Nr. Operations 1000000 cycle
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
42 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 2 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
Degree of Protection:
IP20
Recommended Screw Driver:
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Tightening Torque:
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Terminal Type:
Screw Terminals
Width in Number of Modular Spacings:
2.0
Product Name:
Installation Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 480 V AC
General Use Rating UL/CSA:
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
Horsepower Rating UL/CSA:
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Three Phase, NC 3 Hp
(440 ... 480 V AC) Single Phase, NC 0.5 Hp
(440 ... 480 V AC) Three Phase, NC 2 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Three Phase, NC 3 Hp
(440 ... 480 V AC) Single Phase, NC 0.5 Hp
(440 ... 480 V AC) Three Phase, NC 2 Hp
Connecting Capacity Main Circuit UL/CSA:
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Connecting Capacity Control Circuit UL/CSA:
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Tightening Torque UL/CSA:
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Full Load Amps Motor Use:
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Three Phase, NC 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Three Phase, NC 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Three Phase, NC 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Three Phase, NC 7.6 A

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 15g
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Consumer
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Certificates and Declarations

EAC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
39 mm
Package Level 1 Height:
69.5 mm
Package Level 1 Gross Weight:
0.245 kg
Package Level 1 EAN:
4013614523984
Package Level 2 Units:
48 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
12.3 kg
Package Level 2 EAN:
4013614538384

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC001653 - Installation contactor for distribution board
ETIM 8:
EC001653 - Installation contactor for distribution board
ETIM 9:
EC001653 - Installation contactor for distribution board
eClass:
V11.0 : 27142308
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4759 >> Installation contactor for distribution board
1SAE231111R0231 ABB - ESB25-31N-02
ABB 1SAE231111R0231 ABB - ESB25-31N-02
Sale price0.00 kr
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080

Popular Downloads

EPLAN Data:
Data Sheet, Technical Information:

Dimensions

Product Net Width:
36 mm
Product Net Depth / Length:
65 mm
Product Net Height:
85 mm
Product Net Weight:
0.245 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
1
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
4P
Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Rated Operational Voltage:
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated Operational Current AC-1 (Ie):
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
Rated Operational Current AC-3 (Ie):
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
Rated Operational Current AC-7a (Ie):
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
Rated Operational Current AC-7b (Ie):
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
Rated Operational Power AC-1 (Pe):
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
Rated Operational Power AC-3 (Pe):
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
Rated Operational Power AC-7a (Pe):
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
Rated Operational Power AC-7b (Pe):
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
Rated Breaking Capacity AC-3:
8 x Ie / AC-3
Rated Making Capacity AC-3:
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui):
500 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Electrical Durability:
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Mechanical Durability:
Nr. Operations 1000000 cycle
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
42 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 2 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
Degree of Protection:
IP20
Recommended Screw Driver:
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Tightening Torque:
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Terminal Type:
Screw Terminals
Width in Number of Modular Spacings:
2.0
Product Name:
Installation Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 480 V AC
General Use Rating UL/CSA:
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
Horsepower Rating UL/CSA:
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
Connecting Capacity Main Circuit UL/CSA:
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Connecting Capacity Control Circuit UL/CSA:
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Tightening Torque UL/CSA:
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Full Load Amps Motor Use:
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 15g
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Consumer
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Certificates and Declarations

EAC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
39 mm
Package Level 1 Height:
69.5 mm
Package Level 1 Gross Weight:
0.245 kg
Package Level 1 EAN:
4013614524035
Package Level 2 Units:
48 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
12.3 kg
Package Level 2 EAN:
4013614538438

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC001653 - Installation contactor for distribution board
ETIM 8:
EC001653 - Installation contactor for distribution board
ETIM 9:
EC001653 - Installation contactor for distribution board
eClass:
V11.0 : 27142308
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4759 >> Installation contactor for distribution board
1SAE231111R0422 ABB - ESB25-22N-04
ABB 1SAE231111R0422 ABB - ESB25-22N-04
Sale price0.00 kr
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080

Popular Downloads

EPLAN Data:
Data Sheet, Technical Information:

Dimensions

Product Net Width:
36 mm
Product Net Depth / Length:
65 mm
Product Net Height:
85 mm
Product Net Weight:
0.24 kg

Technical

Number of Main Contacts NO:
2
Number of Main Contacts NC:
2
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
4P
Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Rated Operational Voltage:
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated Operational Current AC-1 (Ie):
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
Rated Operational Current AC-3 (Ie):
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
Rated Operational Current AC-7a (Ie):
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
Rated Operational Current AC-7b (Ie):
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
Rated Operational Power AC-1 (Pe):
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
Rated Operational Power AC-3 (Pe):
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
Rated Operational Power AC-7a (Pe):
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
Rated Operational Power AC-7b (Pe):
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
Rated Breaking Capacity AC-3:
8 x Ie / AC-3
Rated Making Capacity AC-3:
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui):
500 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Electrical Durability:
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Mechanical Durability:
Nr. Operations 1000000 cycle
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
110 ... 120 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 2 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
Degree of Protection:
IP20
Recommended Screw Driver:
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Tightening Torque:
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Terminal Type:
Screw Terminals
Width in Number of Modular Spacings:
2.0
Product Name:
Installation Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 480 V AC
General Use Rating UL/CSA:
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
Horsepower Rating UL/CSA:
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
Connecting Capacity Main Circuit UL/CSA:
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Connecting Capacity Control Circuit UL/CSA:
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Tightening Torque UL/CSA:
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Full Load Amps Motor Use:
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 15g
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Consumer
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Certificates and Declarations

EAC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
39 mm
Package Level 1 Height:
69.5 mm
Package Level 1 Gross Weight:
0.24 kg
Package Level 1 EAN:
4013614524158
Package Level 2 Units:
48 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
12 kg
Package Level 2 EAN:
4013614538551

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC001653 - Installation contactor for distribution board
ETIM 8:
EC001653 - Installation contactor for distribution board
ETIM 9:
EC001653 - Installation contactor for distribution board
eClass:
V11.0 : 27142308
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4759 >> Installation contactor for distribution board
E-Number (Norway):
4190259
1SAE231111R0440 ABB - ESB25-40N-04
ABB 1SAE231111R0440 ABB - ESB25-40N-04
Sale price0.00 kr
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080

Popular Downloads

EPLAN Data:
Data Sheet, Technical Information:

Dimensions

Product Net Width:
36 mm
Product Net Depth / Length:
65 mm
Product Net Height:
85 mm
Product Net Weight:
0.24 kg

Technical

Number of Main Contacts NO:
4
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
4P
Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Rated Operational Voltage:
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated Operational Current AC-1 (Ie):
(NO) 25 A
Rated Operational Current AC-3 (Ie):
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
Rated Operational Current AC-7a (Ie):
(NO) 25 A
Rated Operational Current AC-7b (Ie):
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
Rated Operational Power AC-1 (Pe):
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
Rated Operational Power AC-3 (Pe):
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
Rated Operational Power AC-7a (Pe):
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
Rated Operational Power AC-7b (Pe):
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
Rated Breaking Capacity AC-3:
8 x Ie / AC-3
Rated Making Capacity AC-3:
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui):
500 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Electrical Durability:
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Mechanical Durability:
Nr. Operations 1000000 cycle
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
110 ... 120 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 2 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
Degree of Protection:
IP20
Recommended Screw Driver:
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Tightening Torque:
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Terminal Type:
Screw Terminals
Width in Number of Modular Spacings:
2.0
Product Name:
Installation Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 480 V AC
General Use Rating UL/CSA:
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
Horsepower Rating UL/CSA:
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
Connecting Capacity Main Circuit UL/CSA:
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Connecting Capacity Control Circuit UL/CSA:
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Tightening Torque UL/CSA:
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Full Load Amps Motor Use:
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 15g
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Consumer
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Certificates and Declarations

EAC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
39 mm
Package Level 1 Height:
69.5 mm
Package Level 1 Gross Weight:
0.24 kg
Package Level 1 EAN:
4013614524189
Package Level 2 Units:
48 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
12 kg
Package Level 2 EAN:
4013614538582

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC001653 - Installation contactor for distribution board
ETIM 8:
EC001653 - Installation contactor for distribution board
ETIM 9:
EC001653 - Installation contactor for distribution board
eClass:
V11.0 : 27142308
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4759 >> Installation contactor for distribution board
E-Number (Norway):
4190248
1SAE231111R0604 ABB - ESB25-04N-06
ABB 1SAE231111R0604 ABB - ESB25-04N-06
Sale price0.00 kr
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080

Popular Downloads

EPLAN Data:
Data Sheet, Technical Information:

Dimensions

Product Net Width:
36 mm
Product Net Depth / Length:
65 mm
Product Net Height:
85 mm
Product Net Weight:
0.235 kg

Technical

Number of Main Contacts NO:
0
Number of Main Contacts NC:
4
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
4P
Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Rated Operational Voltage:
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated Operational Current AC-1 (Ie):
(NC) 25 A
Rated Operational Current AC-3 (Ie):
(230 V) Single Phase, NC 6 A
Rated Operational Current AC-7a (Ie):
(NC) 25 A
Rated Operational Current AC-7b (Ie):
(400 V) Three Phase, NC 6 A
Rated Operational Power AC-1 (Pe):
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.3 kW
Rated Operational Power AC-3 (Pe):
(230 V) Single Phase, NC 0.9 kW
(400 V) Three Phase, NC 2.7 kW
(230 V) Single Phase, NC 0.9 kW
(400 V) Three Phase, NC 2.7 kW
Rated Operational Power AC-7a (Pe):
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.25 kW
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.25 kW
Rated Operational Power AC-7b (Pe):
(230 V) Single Phase, NC 2.7 kW
(400 V) Three Phase, NC 2.7 kW
(230 V) Single Phase, NC 2.7 kW
(400 V) Three Phase, NC 2.7 kW
Rated Breaking Capacity AC-3:
8 x Ie / AC-3
Rated Making Capacity AC-3:
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui):
500 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Electrical Durability:
AC-1 (NC) 50000 cycle
AC-3 (NC) 340000 cycle
AC-7a (NC) 50000 cycle
AC-7b (NC) 340000 cycle
AC-1 (NC) 50000 cycle
AC-3 (NC) 340000 cycle
AC-7a (NC) 50000 cycle
AC-7b (NC) 340000 cycle
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Mechanical Durability:
Nr. Operations 1000000 cycle
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
230 ... 240 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 2 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
Degree of Protection:
IP20
Recommended Screw Driver:
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Tightening Torque:
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Terminal Type:
Screw Terminals
Width in Number of Modular Spacings:
2.0
Product Name:
Installation Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 480 V AC
General Use Rating UL/CSA:
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
Horsepower Rating UL/CSA:
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Three Phase, NC 3 Hp
(440 ... 480 V AC) Single Phase, NC 0.5 Hp
(440 ... 480 V AC) Three Phase, NC 2 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Three Phase, NC 3 Hp
(440 ... 480 V AC) Single Phase, NC 0.5 Hp
(440 ... 480 V AC) Three Phase, NC 2 Hp
Connecting Capacity Main Circuit UL/CSA:
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Connecting Capacity Control Circuit UL/CSA:
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Tightening Torque UL/CSA:
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Full Load Amps Motor Use:
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Three Phase, NC 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Three Phase, NC 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Three Phase, NC 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Three Phase, NC 7.6 A

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 15g
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Consumer
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Certificates and Declarations

EAC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
39 mm
Package Level 1 Height:
69.5 mm
Package Level 1 Gross Weight:
0.235 kg
Package Level 1 EAN:
4013614524196
Package Level 2 Units:
48 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
11.8 kg
Package Level 2 EAN:
4013614538599

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC001653 - Installation contactor for distribution board
ETIM 8:
EC001653 - Installation contactor for distribution board
ETIM 9:
EC001653 - Installation contactor for distribution board
eClass:
V11.0 : 27142308
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4759 >> Installation contactor for distribution board
E-Number (Finland):
3707573
E-Number (Norway):
4190255
E-Number (Sweden):
3210563

Recently viewed