Variable Frequency Drives

25001 products

Showing 913 - 936 of 25001 products

Showing 913 - 936 of 25001 products
View
ACS510-01-038A-4 ABB
ABB ACS510-01-038A-4 ABB
Sale price 11,848.00 kr
Only 8 units left

ACS510,38A,380V; ACS510-01-038A-4

1SVR730712R1200 ABB - CM-MSS.41S
ABB 1SVR730712R1200 ABB - CM-MSS.41S
Sale price 1,995.00 kr
In stock, 11 units

Ordering

EAN:
4013614496677
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
22.5 mm
Product Net Height:
85.6 mm
Product Net Depth / Length:
103.7 mm
Product Net Weight:
0.141 kg

Technical

Function:
1 sensor circuit
Auto, manual or remote reset
ATEX approved
Dynamic interrupted wire detection
Short-circuit detection, configurable
Non-volatile fault storage, configurable
1 sensor circuit
Auto, manual or remote reset
ATEX approved
Dynamic interrupted wire detection
Short-circuit detection, configurable
Non-volatile fault storage, configurable
Rated Control Supply Voltage (Us):
24 ... 240 V AC/DC
Rated Operational Voltage:
Auxiliary Circuit 250 V AC
Rated Frequency (f):
Supply Circuit 15 ... 400 Hz
Output:
2 c/o (SPDT) contacts
Terminal Type:
Screw Terminals
Rated Operational Current AC-12 (Ie):
(230 V) 4 A
Rated Operational Current AC-15 (Ie):
(230 V) 3 A
Rated Operational Current DC-12 (Ie):
(24 V) 4 A
Rated Operational Current DC-13 (Ie):
(24 V) 2 A
Minimum Switching Capacity:
24 V
10 mA
24 V
10 mA
Rated Impulse Withstand Voltage (Uimp):
Output Circuit 1 / Output Circuit 2 4 kV
Output Circuit 4 kV
Output Circuit 1 / Output Circuit 2 4 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui):
Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Measuring Circuit 300 V
Supply Circuit / Output Circuit 300 V
Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Measuring Circuit 300 V
Supply Circuit / Output Circuit 300 V
Degree of Protection:
Housing IP50
Terminals IP20
Housing IP50
Terminals IP20
Overvoltage Category:
III
Pollution Degree:
3
Short-Circuit Protective Devices:
Output Circuit NC - F Type Fuses 10 A
Output Circuit NO - F Type Fuses 10 A
Output Circuit NC - F Type Fuses 10 A
Output Circuit NO - F Type Fuses 10 A
Electrical Durability:
AC-12 100000 cycle
Mechanical Durability:
Nr. Operations 30000000 cycle
Connecting Capacity:
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque:
0.6 ... 0.8 N·m
Wire Stripping Length:
8 mm
Recommended Screw Driver:
4.5
0.8 x 4
Pozidriv 1
4.5
0.8 x 4
Pozidriv 1
Mounting Position:
1 ... 6
Mounting on DIN Rail:
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Standards:
CAN/CSA C22.2 No.14
EN 50495
IEC/EN 63000
IEC/EN 60079-7
IEC/EN 60947-5-1
IEC/EN 60947-8
UL 508
CAN/CSA C22.2 No.14
EN 50495
IEC/EN 63000
IEC/EN 60079-7
IEC/EN 60947-5-1
IEC/EN 60947-8
UL 508

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Output Circuit 300 V AC
Contact Rating UL/CSA:
B300
Connecting Capacity UL/CSA:
Flexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 2x 20-14 AWG
Rigid 1x 20-12 AWG
Flexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 2x 20-14 AWG
Rigid 1x 20-12 AWG
Tightening Torque UL/CSA:
7.08 in·lb
Pilot Duty UL/CSA:
B300
Flammability According to UL94:
V-0

Environmental

Ambient Air Temperature:
Operation -25 ... +60 °C
Storage -40 ... +85 °C
Operation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude Permissible:
Without Derating 2000 m

Material Compliance

Conflict Minerals Reporting Template (CMRT):
SCIP:
d4dbc433-2a16-40d0-8ee2-d005b9e2fea2 Germany
Simplified SCIP:
97fdf0e9-e196-4fa0-8b24-f288fe8e9aea France
5191e536-19e2-42c2-8888-343710fc4118 Sweden
5d6c5da3-8f68-42fd-9452-cf86ffc3d84d Germany
0579a862-9a96-4513-8980-cd4c82f17264 Sweden
0c255667-c4e9-4c28-9eb0-619a2a8c134a Poland
e47abcda-c347-4b9a-8de6-255a532151d6 France
6c416bdf-8553-4a46-81af-af49326e8d14 Hungary
ac7fed6b-1252-450f-b2e1-67786a5c142b Belgium
6ababbce-f6ab-49c4-8797-e0a3f2f21de1 Spain
85fb3565-2def-4c91-8fb1-afebf0692157 Bulgaria
ea3fb2c1-a709-4fa1-a37e-a9002337e517 Netherlands
95d5aebf-caea-4a1a-bed0-558c46030260 Estonia
9a041399-78a0-4b77-9ada-d82e3356bec9 Poland
4c7702b2-4eff-4547-ba87-e6ee9575694a Hungary
2c2ea1a2-b79e-420e-a57c-d37acf25df90 Portugal
0020ec2f-b7df-48d8-8fce-e791b7da1069 Greece
a4801e96-395e-4492-bfd7-4210043288ab Germany
abb6a722-0c77-48a9-ad1c-b5266d9b9708 Czech Republic
e54804b2-476f-4c71-82ce-52accc36c3f3 Germany
aec3a7c8-eef9-4d1b-8cdd-f86a48a801a1 Croatia
da4ef4be-a365-467b-b662-882c7a29d45d Germany
535ca094-48b0-488b-90a6-7f2dd88abbed Italy
ee217793-1566-48f9-b125-2c8fad4b9f66 Denmark
401e70ee-8d39-45c4-8a10-391b95410818 Poland
1c31e64e-be0c-44f3-9263-d14274188b4b Norway
161de862-9a33-4035-94b7-de947bffc6c0 Finland
e68db441-f9c9-40d4-9477-b376a0e8ad8f Belgium
97fdf0e9-e196-4fa0-8b24-f288fe8e9aea France
5191e536-19e2-42c2-8888-343710fc4118 Sweden
5d6c5da3-8f68-42fd-9452-cf86ffc3d84d Germany
0579a862-9a96-4513-8980-cd4c82f17264 Sweden
0c255667-c4e9-4c28-9eb0-619a2a8c134a Poland
e47abcda-c347-4b9a-8de6-255a532151d6 France
6c416bdf-8553-4a46-81af-af49326e8d14 Hungary
ac7fed6b-1252-450f-b2e1-67786a5c142b Belgium
6ababbce-f6ab-49c4-8797-e0a3f2f21de1 Spain
85fb3565-2def-4c91-8fb1-afebf0692157 Bulgaria

ABB EcoSolutions

ABB EcoSolutions:
Yes

Certificates and Declarations

CB Certificate:
cULus Certificate:
Declaration of Conformity - UKCA:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
97 mm
Package Level 1 Depth / Length:
30 mm
Package Level 1 Height:
109 mm
Package Level 1 Gross Weight:
0.167 kg
Package Level 1 EAN:
4013614496677

External Classifications and Standards

Object Classification Code:
B
ETIM 7:
EC002568 - Relay for thermistor protection (PTC)
ETIM 8:
EC002568 - Relay for thermistor protection (PTC)
ETIM 9:
EC002568 - Relay for thermistor protection (PTC)
eClass:
V11.0 : 27371503
UNSPSC:
39122331
E-Number (Finland):
2712512
E-Number (Norway):
4187717
E-Number (Sweden):
3860738
DCS800-S02-0520-05 ABB
ABB DCS800-S02-0520-05 ABB
Sale price 194,854.00 kr
Only 2 units left

DC Variable Frequency Drive (100 HP, 250 HP), 230 VAC / 240 VDC 4-QUADRANT REVERSING

1SAM250000R1002 ABB - MS116-0.25
ABB 1SAM250000R1002 ABB - MS116-0.25
Sale price 1,127.00 kr
Only 7 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362010

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals (Part 2):

Dimensions

Product Net Width:
45 mm
Product Net Height:
90 mm
Product Net Depth / Length:
85.6 mm
Product Net Weight:
0.225 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics):
(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 30 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 30 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii):
3.1 A
Setting Range:
0.16 ... 0.25 A
Rated Operational Power AC-3 (Pe):
(400 V) Three Phase 0.06 kW
Rated Operational Power AC-3e (Pe):
(400 V) Three Phase 0.06 kW
Rated Operational Voltage:
Main Circuit 690 V AC
Rated Operational Current (Ie):
0.25 A
Rated Operational Current AC-3 (Ie):
0.25 A
Rated Operational Current AC-3e (Ie):
0.25 A
Rated Frequency (f):
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 6 kV
Rated Insulation Voltage (Ui):
690 V
Power Loss:
at Rated Operating Conditions per Pole 0.7 ... 1.6 W
Number of Poles:
3P
Conventional Free-air Thermal Current (Ith):
Main Circuit 0.25 A
Degree of Protection:
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
Pollution Degree:
3
Electrical Durability:
100000 cycle
Mechanical Durability:
Nr. Operations 100000 cycle
Terminal Type:
Screw Terminals
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Tightening Torque:
Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length:
Main Circuit 9 mm
Recommended Screw Driver:
Pozidriv 2
Mounting Position:
1 ... 6
any
1 ... 6
any
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance:
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type:
Rotary Handle
Contact Position Indication:
ON / OFF
Standards:
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L

Technical UL/CSA

Short-Circuit Current Rating (SCCR):
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V AC
Full Load Amps Motor Use:
(110 ... 120 V AC) Three Phase 0.25 A
(200 V AC) Three Phase 0.25 A
(208 V AC) Three Phase 0.25 A
(220 ... 240 V AC) Three Phase 0.25 A
(440 ... 480 V AC) Three Phase 0.25 A
(550 ... 600 V AC) Three Phase 0.25 A
(110 ... 120 V AC) Three Phase 0.25 A
(200 V AC) Three Phase 0.25 A
(208 V AC) Three Phase 0.25 A
(220 ... 240 V AC) Three Phase 0.25 A
(440 ... 480 V AC) Three Phase 0.25 A
(550 ... 600 V AC) Three Phase 0.25 A
Locked Rotor Amps:
(110 ... 120 V AC) Three Phase 1.5 A
(200 V AC) Three Phase 1.5 A
(208 V AC) Three Phase 1.5 A
(220 ... 240 V AC) Three Phase 1.5 A
(440 ... 480 V AC) Three Phase 1.5 A
(550 ... 600 V AC) Three Phase 1.5 A
(110 ... 120 V AC) Three Phase 1.5 A
(200 V AC) Three Phase 1.5 A
(208 V AC) Three Phase 1.5 A
(220 ... 240 V AC) Three Phase 1.5 A
(440 ... 480 V AC) Three Phase 1.5 A
(550 ... 600 V AC) Three Phase 1.5 A
General Use Rating UL/CSA:
(600 V AC) 0.25 A
Connecting Capacity Main Circuit UL/CSA:
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSA:
Main Circuit 10 in·lb

Environmental

Ambient Air Temperature:
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +55 °C
Storage -50 ... +80 °C
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +55 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation:
Yes
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 25g
Resistance to Vibrations:
2g 5 ... 150 Hz
5g 3 ... 150 Hz
2g 5 ... 150 Hz
5g 3 ... 150 Hz

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Certificates and Declarations

GL Certificate:
KC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
95 mm
Package Level 1 Height:
50 mm
Package Level 1 Gross Weight:
0.24 kg
Package Level 1 EAN:
4013614320255
Package Level 2 Units:
carton 40 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
9.986 kg
Package Level 2 EAN:
4013614408625

External Classifications and Standards

Object Classification Code:
F
ETIM 9:
EC000074 - Motor protection circuit-breaker
ETIM 10:
EC000074 - Motor protection circuit-breaker
eClass:
V11.0 : 27370401
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4731 >> Manual Starters
E-Number (Finland):
3706002
E-Number (Norway):
4364268
E-Number (Sweden):
3111932
1SAM250000R1010 ABB - MS116-10
ABB 1SAM250000R1010 ABB - MS116-10
Sale price 1,147.00 kr
In stock, 12 units

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362010

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals (Part 2):
Time-Current Characteristic Curve:

Dimensions

Product Net Width:
45 mm
Product Net Height:
90 mm
Product Net Depth / Length:
85.6 mm
Product Net Weight:
0.265 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics):
(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 6 kA
(500 V AC) 6 kA
(690 V AC) 2 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 6 kA
(500 V AC) 6 kA
(690 V AC) 2 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(230 V AC) 75 kA
(400 V AC) 75 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(690 V AC) 3 kA
(230 V AC) 75 kA
(400 V AC) 75 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii):
150 A
Setting Range:
6.3 ... 10 A
Rated Operational Power AC-3 (Pe):
(400 V) Three Phase 4 kW
Rated Operational Power AC-3e (Pe):
(400 V) Three Phase 4 kW
Rated Operational Voltage:
Main Circuit 690 V AC
Rated Operational Current (Ie):
10 A
Rated Operational Current AC-3 (Ie):
10 A
Rated Operational Current AC-3e (Ie):
10 A
Rated Frequency (f):
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 6 kV
Rated Insulation Voltage (Ui):
690 V
Power Loss:
at Rated Operating Conditions per Pole 0.9 ... 2.4 W
Number of Poles:
3P
Conventional Free-air Thermal Current (Ith):
Main Circuit 10 A
Degree of Protection:
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
Pollution Degree:
3
Electrical Durability:
100000 cycle
Mechanical Durability:
Nr. Operations 100000 cycle
Terminal Type:
Screw Terminals
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Tightening Torque:
Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length:
Main Circuit 9 mm
Recommended Screw Driver:
Pozidriv 2
Mounting Position:
1 ... 6
any
1 ... 6
any
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance:
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type:
Rotary Handle
Contact Position Indication:
ON / OFF
Standards:
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L

Technical UL/CSA

Short-Circuit Current Rating (SCCR):
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V AC
Horsepower Rating UL/CSA:
(200 V AC) Three Phase 2 Hp
(208 V AC) Three Phase 2 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 5 Hp
(550 ... 600 V AC) Three Phase 7.5 Hp
(200 V AC) Three Phase 2 Hp
(208 V AC) Three Phase 2 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 5 Hp
(550 ... 600 V AC) Three Phase 7.5 Hp
Full Load Amps Motor Use:
(200 V AC) Three Phase 7.8 A
(208 V AC) Three Phase 7.5 A
(220 ... 240 V AC) Three Phase 9.6 A
(440 ... 480 V AC) Three Phase 7.6 A
(550 ... 600 V AC) Three Phase 9 A
(200 V AC) Three Phase 7.8 A
(208 V AC) Three Phase 7.5 A
(220 ... 240 V AC) Three Phase 9.6 A
(440 ... 480 V AC) Three Phase 7.6 A
(550 ... 600 V AC) Three Phase 9 A
Locked Rotor Amps:
(200 V AC) Three Phase 57.5 A
(208 V AC) Three Phase 55 A
(220 ... 240 V AC) Three Phase 64 A
(440 ... 480 V AC) Three Phase 46 A
(550 ... 600 V AC) Three Phase 50.8 A
(200 V AC) Three Phase 57.5 A
(208 V AC) Three Phase 55 A
(220 ... 240 V AC) Three Phase 64 A
(440 ... 480 V AC) Three Phase 46 A
(550 ... 600 V AC) Three Phase 50.8 A
General Use Rating UL/CSA:
(600 V AC) 10 A
Connecting Capacity Main Circuit UL/CSA:
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSA:
Main Circuit 10 in·lb

Environmental

Ambient Air Temperature:
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +55 °C
Storage -50 ... +80 °C
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +55 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation:
Yes
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 25g
Resistance to Vibrations:
2g 5 ... 150 Hz
5g 3 ... 150 Hz
2g 5 ... 150 Hz
5g 3 ... 150 Hz

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Certificates and Declarations

GL Certificate:
KC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
95 mm
Package Level 1 Height:
50 mm
Package Level 1 Gross Weight:
0.28 kg
Package Level 1 EAN:
4013614320330
Package Level 2 Units:
carton 40 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
11.586 kg
Package Level 2 EAN:
4013614408700

External Classifications and Standards

Object Classification Code:
F
ETIM 9:
EC000074 - Motor protection circuit-breaker
ETIM 10:
EC000074 - Motor protection circuit-breaker
eClass:
V11.0 : 27370401
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4731 >> Manual Starters
E-Number (Finland):
3706010
E-Number (Norway):
4364276
E-Number (Sweden):
3111948
ACS355-03U-12A5-4 - ABB
ABB ACS355-03U-12A5-4 - ABB
Sale price 10,042.00 kr
In stock, 11 units

ACS355, 7.5HP, 3-Phase, 380-480V (Input), IP20 Enclosure, Variable Frequency Drives

64607901 ABB - RDCU-02C
ABB 64607901 ABB - RDCU-02C
Sale price 66,440.00 kr
Only 6 units left

DRIVE CONTROL UNIT, COATED, BLANK, 24 VDC

1SFL551001R8011 ABB - A300-30-11-80
ABB 1SFL551001R8011 ABB - A300-30-11-80
Sale price 9,280.00 kr
Only 7 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900
Replacement Product ID (NEW):

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals:
Dimension Diagram:

Dimensions

Product Net Width:
140 mm
Product Net Depth / Length:
180.5 mm
Product Net Height:
227 mm
Product Net Weight:
5.4 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Number of Poles:
3P
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 500 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 500 A
(690 V) 55 °C 400 A
(690 V) 70 °C 325 A
(690 V) 40 °C 500 A
(690 V) 55 °C 400 A
(690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie):
(415 V) 55 °C 300 A
(440 V) 55 °C 280 A
(500 V) 55 °C 280 A
(690 V) 55 °C 280 A
(380 / 400 V) 55 °C 305 A
(220 / 230 / 240 V) 55 °C 305
(415 V) 55 °C 300 A
(440 V) 55 °C 280 A
(500 V) 55 °C 280 A
(690 V) 55 °C 280 A
(380 / 400 V) 55 °C 305 A
(220 / 230 / 240 V) 55 °C 305
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
(110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
(110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
(110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Power AC-3 (Pe):
(415 V) 160 kW
(440 V) 160 kW
(500 V) 200 kW
(690 V) 250 kW
(380 / 400 V) 160 kW
(220 / 230 / 240 V) 90 kW
(415 V) 160 kW
(440 V) 160 kW
(500 V) 200 kW
(690 V) 250 kW
(380 / 400 V) 160 kW
(220 / 230 / 240 V) 90 kW
Rated Breaking Capacity AC-3:
8 x Ie AC-3
Rated Making Capacity AC-3:
10 x Ie AC-3
Short-Circuit Protective Devices:
gG Type Fuses 500 A
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 8 kV
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
Mechanical Durability:
5 million
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc):
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 50 Hz 60 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 65 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1350 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1550 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 60 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 65 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1350 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1550 V·A
Power Loss:
at Rated Operating Conditions per Pole 18 W
Operate Time:
Between Coil De-energization and NC Contact Closing 7 ... 13 ms
Between Coil De-energization and NO Contact Opening 10 ... 16 ms
Between Coil Energization and NC Contact Opening 12 ... 30 ms
Between Coil Energization and NO Contact Closing 17 ... 35 ms
Between Coil De-energization and NC Contact Closing 7 ... 13 ms
Between Coil De-energization and NO Contact Opening 10 ... 16 ms
Between Coil Energization and NC Contact Opening 12 ... 30 ms
Between Coil Energization and NO Contact Closing 17 ... 35 ms
Connecting Capacity Main Circuit:
Bar 32 mm²
Rigid Al-Cable 2 x 95 ... 120 mm²
Rigid Cu-Cable 16 ... 240 mm²
Bar 32 mm²
Rigid Al-Cable 2 x 95 ... 120 mm²
Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Connecting Capacity:
Bar 32 mm²
Rigid Al-Cable 120 ... 240 mm²
Rigid Cu-Cable 16 ... 240 mm²
Bar 32 mm²
Rigid Al-Cable 120 ... 240 mm²
Rigid Cu-Cable 16 ... 240 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main Poles:
Flat type c/w screws and bolts
Tightening Torque:
Main Circuit 28 N·m
Terminal Type:
Main Circuit: Bars
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 400 A
Horsepower Rating UL/CSA:
(200 V AC) Three Phase 100 hp
(208 V AC) Three Phase 100 hp
(220 ... 240 V AC) Three Phase 100 hp
(440 ... 480 V AC) Three Phase 250 hp
(550 ... 600 V AC) Three Phase 300 hp
(200 V AC) Three Phase 100 hp
(208 V AC) Three Phase 100 hp
(220 ... 240 V AC) Three Phase 100 hp
(440 ... 480 V AC) Three Phase 250 hp
(550 ... 600 V AC) Three Phase 300 hp
Full Load Amps Motor Use:
(440 ... 480 V AC) Three Phase 302 A
(550 ... 600 V AC) Three Phase 289 A
(440 ... 480 V AC) Three Phase 302 A
(550 ... 600 V AC) Three Phase 289 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Shock Direction: A 5 g
Shock Direction: B1 5 g
Shock Direction: B2 5 g
Shock Direction: C1 5 g
Shock Direction: C2 5 g
Shock Direction: A 5 g
Shock Direction: B1 5 g
Shock Direction: B2 5 g
Shock Direction: C1 5 g
Shock Direction: C2 5 g

Certificates and Declarations

BV Certificate:
CSA Certificate:
Declaration of Conformity - UKCA:
DNV Certificate:
GL Certificate:
LOVAG Certificate:
LR Certificate:
RINA Certificate:
RMRS Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
203 mm
Package Level 1 Depth / Length:
245 mm
Package Level 1 Height:
188 mm
Package Level 1 Gross Weight:
6.1 kg
Package Level 1 EAN:
7320500203361

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4755 >> Contactors
E-Number (Finland):
3709331
E-Number (Norway):
4115256
E-Number (Sweden):
3227894
ABB New Stock Image
ABB 3AUA0000097468 ABB
Sale price 2,366.00 kr
In stock, 12 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
3ADT312500R0001 ABB - SDCS-PIN-205B
ABB 3ADT312500R0001 ABB - SDCS-PIN-205B
Sale price 16,428.00 kr
Only 5 units left

POWER INTERFACE BOARD, FUSED, STAND-OFF MOUNT

ABB New Stock Image
ABB AF305-30-11-13 ABB
Sale price 7,337.00 kr
Only 10 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB Stock Image
ABB 3HAC046404-003 ABB
Sale price 21,313.00 kr
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Yaskawa Stock Image
Yaskawa JZRCR-NTU02D-2 Yaskawa
Sale price 14,033.00 kr
Only 7 units left
Buy the Yaskawa JZRCR-NTU02D-2 Power Supply - an industrial-grade power supply module providing regulated DC output for Yaskawa automation systems. Features overcurrent protection, high efficiency, wide input voltage range, and DIN-rail mounting. The Yaskawa JZRCR-NTU02D-2 is a direct replacement for existing installations.
Yaskawa New Stock Image
Yaskawa CIMR-VU4A0002FAA Yaskawa
Sale price 10,676.00 kr
Only 8 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Yaskawa New Stock Image
Yaskawa JVOP-KPLCA04MEB Yaskawa
Sale price 3,704.00 kr
Only 1 unit left

The JVOP-KPLCA04MEB unit represents an exceptional interface solution, featuring a keypad with an LCD display and connectivity provided through an RJ-45 port, tailored for HMI, MMI, and OIT systems. With its requirement for only 5 VDC to operate, this device offers an efficient way to enhance user interaction within automation systems. Designed to meet the needs of a broad range of industrial applications, its straightforward integration and operational reliability ensure it's a key component for facilitating user control and system monitoring.

CIMR-VCBA0006BAA Yaskawa
Yaskawa CIMR-VCBA0006BAA Yaskawa
Sale price 4,115.00 kr
In stock, 21 units

The Yaskawa V1000 is a general-purpose AC drive covering the demands of a wide field of applications including Open-Loop-Vector functionality and the use of PM motors without feedback. High flux braking for 50% reduction of braking time. Online Auto-Tuning to optimize for improved motor performance at low speed. Open Loop Vector Control for PM motor operation. Safe Disable Inputs for Safe Torque OFF.

Yaskawa Stock Image
Yaskawa CIPR-GA80U4007ABMA-AAAANA Yaskawa
Sale price0.00 kr
Sold Out

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Yaskawa Stock Image
Yaskawa CIMR-PW4A0023FAA Yaskawa
Sale price 23,314.00 kr
Only 4 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Yaskawa New Stock Image
Yaskawa CIMR-AU4A0044FAA Yaskawa
Sale price 15,390.00 kr
Only 5 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
CIPRGA50U4038ABAA Yaskawa
Yaskawa CIPRGA50U4038ABAA Yaskawa
Sale price 7,844.00 kr
Only 2 units left

Yaskawa GA50U4038ABA 480 Volt Three Phase 38 Amp 25 HP Microdrive

CIMR-JC4A0011BAA Yaskawa
Yaskawa CIMR-JC4A0011BAA Yaskawa
Sale price 4,288.00 kr
In stock, 16 units

Inverter Drive, 9.2A, Three Phase, 4kW

6SL3224-0BE25-5AA0 Siemens
Siemens 6SL3224-0BE25-5AA0 Siemens
Sale price 14,712.00 kr
In stock, 12 units
Product
Article Number (Market Facing Number) 6SL32240BE255AA0 | 6SL32240BE255AA0
Product Description ***spare part*** SINAMICS G120 PM240 Power Module with integrated filter class A with integrated braking chopper 380-480 V 3 AC +10/-10% 47-63 Hz power high overload: 5.5 kW at 200% 3 s,150% 57 s,100% 240 s ambient temperature -10 to +50 °C power low overload: 7.5 kW at 150% 3 s,110% 57 s,100% 240 s ambient temperature -10 to +40 °C 334 x 189 x 185 (HxWxD), FSC degree of protection IP20 without Control Unit and BOP
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
Additional Product Information
EAN 4019169453707
UPC 662643434385
Commodity Code 85044085
LKZ_FDB/ CatalogID D11.1SD
Product Group 9486
Group Code R2S3
Country of origin Great Britain
SCIP number 384ca50d-2e96-4f28-8768-9cbd6f454e15
Delivery information
Net Weight (lb) 15.432 lb
Package size unit of measure Inch
Packaging Quantity 1
6SL3120-1TE32-0AA4 Siemens
Siemens 6SL3120-1TE32-0AA4 Siemens
Sale price 85,807.00 kr
In stock, 15 units
Product
Article Number (Market Facing Number) 6SL31201TE320AA4 | 6SL31201TE320AA4
Product Description SINAMICS S120 SINGLE MOTOR MODULE INPUT: DC 600V OUTPUT: 3AC 400V, 200A OUTPUT: at 8 kHz / 140A FRAME SIZE: BOOKSIZE INTERNAL AIR COOLING OPTIMIZED PULSE SAMPLE AND SUPPORT OF THE EXTENDED SAFETY INTEGRATED FUNCTIONS INCL. DRIVE-CLIQ CABLE
Product family Ordering Data Overview
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4042948662984
UPC 662643927818
Commodity Code 85044086
LKZ_FDB/ CatalogID D21MC
Product Group 9617
Group Code R220
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 47.620 lb
Package size unit of measure Inch
Packaging Quantity 1
Siemens New Stock Image
Siemens 6SL3203-0BB21-8VA1 Siemens
Sale price 1,774.00 kr
Only 7 units left
Product
Article Number (Market Facing Number) 6SL32030BB218VA1 | 6SL32030BB218VA1
Product Description SINAMICS V90/S210 line filter category C2 for 200-240 V 1 AC, 18 A size 62x155x53 (WxHxD)
Product family Line filters
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4025515684787
UPC 195125199415
Commodity Code 85480090
LKZ_FDB/ CatalogID SINAMICS V90
Product Group 3503
Group Code R220
Country of origin China
SCIP number Not available
Delivery information
Net Weight (lb) 1.543 lb
Package size unit of measure Inch
Packaging Quantity 1

Recently viewed