Ordering
85369010
Terminal block. Screw front, Cable front. 11-pole. Minimum order qty. 6. Order multiple of 6. (TA564-11)
No
6 piece
6 piece
piece
Dimensions
0.036 kg
40 mm
250 mm
150 mm
0.037 kg
6 bag
Certificates and Declarations
20241206
True - contains substances > 0.1 mass percentage
2012
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Technical
Screw front, Cable front. 11-pole. Minimum order qty. 6. Order multiple of 6.
IP20
Electrical: Plug
Additional Information
TA564
Distributed Automation I/Os
External Classifications and Standards
27-24-22-92
EC002584 - Accessories/spare parts for controls
EC002584 - Accessories/spare parts for controls
EC002584 - Accessories/spare parts for controls
32151703
Environmental
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)



ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 75.20 %
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Recycled Cardboard - 98 %
Recycled Paper - 00 %
Chemically Recycled Polymer - 00 %
Recycled Cardboard - 98 %
Recycled Paper - 00 %
Chemically Recycled Polymer - 00 %
Product Durability
Technical
Type A
170 ... 264 V
2 kV
15 kA
EN 61009-1 6000 A
IEC 61009-1 6000 A
EN 61009-1 6000 A
IEC 61009-1 6000 A
11.2 kA
10 kA
Arbitrary
Red ON / Green OFF
3
10000 cycle
20000 cycle
1
1P+N
2
Blue Flag on Toggle
Instantaneous
Right
2.8 N·m
Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device
Toggle - Insulation group II, Black RAL 9005,
sealable in ON-OFF positions
Undelayed
Insulation group I - II, RAL 7035
Failsafe Bi-directional Cylinder-lift Terminal
Yes
0
Busbar 10 ... 10 mm²
Stranded 0.75 ... 25 mm²
Flexible with Ferrule 0.75 ... 16 mm²
Flexible 0.75 ... 16 mm²
Busbar 10 ... 10 mm²
Stranded 0.75 ... 25 mm²
Flexible with Ferrule 0.75 ... 16 mm²
Flexible 0.75 ... 16 mm²
1 - Solid-Core 0.75 … 25 mm²
4 - Multi-Wired 0.75 … 16 mm²
1 - Solid-Core 0.75 … 25 mm²
4 - Multi-Wired 0.75 … 16 mm²
12 mm
Screw Terminals
Electrical
C
acc. to IEC 60898-1 240 V
acc. to IEC/EN 60664-1 500 V
4 kV
AC
6 A
30 mA
10 kA
15 kA
50 … 60 Hz
Average per Pole 1.3 W
Phase Pole 2.4 W
Neutral Pole 0.2 W
Total 2.6 W
Average per Pole 1.3 W
Phase Pole 2.4 W
Neutral Pole 0.2 W
Total 2.6 W
III
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20211115
True - contains substances > 0.1 mass percentage
20240429
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Consumer
Environmental
Operation -25 … 55 °C
30 °C
IP20
IP40
IP20
IP40
2
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
25g 2 shocks 13 ms
Dimensions
2
35 mm
85 mm
69 mm
200 g
69 mm
Engineering
Ordering
box 1 piece
225 g
3211214
1683058
2100618
Certificates and Declarations
Installation
Popular Downloads
External Classifications and Standards
EC000905 - Earth leakage circuit breaker
EC000905 - Earth leakage circuit breaker
39121601
V11.0 : 27142207
4875 >> Residual current circuit breaker (RCCB)
F
IEC/EN 61009-1, IEC/EN 61009-2-1

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Ordering
4016779876506
1 piece
85364900
Popular Downloads
Dimensions
22.5 mm
85.6 mm
103.7 mm
0.119 kg
Technical
Phase failure detection
Phase sequence monitoring
Phase failure detection
Phase sequence monitoring
(L-L) 200 ... 500 V AC
500 ms start-up delay
(L-L) 200 ... 500 V AC
Supply Circuit 50/60 Hz
2 c/o (SPDT) contacts
Screwless Terminals
(230 V) 4 A
(230 V) 3 A
(24 V) 4 A
(24 V) 2 A
24 V
10 mA
24 V
10 mA
Input Circuit 6 kV
Output Circuit 4 kV
Input Circuit 6 kV
Output Circuit 4 kV
Input Circuit / Output Circuit 600 V
Output Circuit 1 / Output Circuit 2 300 V
Input Circuit / Output Circuit 600 V
Output Circuit 1 / Output Circuit 2 300 V
Housing IP50
Terminals IP20
Housing IP50
Terminals IP20
III
3
Output Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Output Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
AC-12 100000 cycle
Nr. Operations 30000000 cycle
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 2x 0.5 ... 1.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 2x 0.5 ... 1.5 mm²
8 mm
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Technical UL/CSA
Output Circuit 300 V AC
B300
Flexible 2x 18-16 AWG
Rigid 2x 20-16 AWG
Flexible 2x 18-16 AWG
Rigid 2x 20-16 AWG
B300
Environmental
Operation -25 ... +60 °C
Storage -40 ... +85 °C
Operation -25 ... +60 °C
Storage -40 ... +85 °C
Without Derating 2000 m
Material Compliance
b9a0bc30-ba41-4f9e-aea3-4fc6dbac9968 Germany
da9cf325-c68e-430b-971f-702e914052d4 Spain
5533b885-9023-4c2e-af82-d2819a841087 Belgium
565bc012-2539-4d90-a05a-7f345bf7ec6c Hungary
1a0e3f7f-d67c-4b57-ab9c-f5ace656a5c3 France
0d3e7ed3-f3f8-40a7-be6a-fde380fd51a9 Poland
aa5cae51-448f-49b5-959b-27d210656d30 Netherlands
318b7b46-8b52-46ed-a033-b3658b42d95b Hungary
bc2657ad-c984-4580-b135-97a2eb0da5f4 Greece
9080824f-cd90-4c55-89b5-d49f7aec08ae Portugal
cc572f68-4e2e-40e9-9b17-4197da140731 Sweden
06450af5-5632-4bff-a9f4-43d802d7e259 Poland
438539df-b487-460f-b796-9809b98da563 France
0aa3766b-a3ad-44e1-a793-6ee372ea7c05 Bulgaria
165c131e-53ce-48a3-be21-ab9eeb207fb4 Sweden
93175cb2-07a8-4e73-be8c-2eacb5cff009 Germany
7ecfd5e8-42b7-4963-b596-16713c36f6f1 Italy
35a34d13-13ac-4080-996d-9819118b0b0f Germany
fd6deb27-8d7e-4643-90bc-04dfbc2a7c13 Estonia
f845ddcf-94ef-4400-a5ae-ed0f5e5d8ad6 Germany
0141ff46-48da-4b76-ab8b-26e7443ae899 Croatia
656f5386-2881-4dd5-86c9-1880b1d8325d Czech Republic
af639068-d32b-4f43-b339-d373e41c6dfc Germany
6a15d8fb-e88f-4203-b507-5170345d06e9 Finland
c57f0cc1-2689-4e81-ac3b-56f6279f24b5 Belgium
5b12aa5e-189c-4eff-8a1e-a41131f8010b Denmark
c6935f35-77a0-4a97-b81c-ac2b2cc0954e Poland
d7c018e4-b109-4b31-89b6-b2cc4b09357d Norway
da9cf325-c68e-430b-971f-702e914052d4 Spain
5533b885-9023-4c2e-af82-d2819a841087 Belgium
565bc012-2539-4d90-a05a-7f345bf7ec6c Hungary
1a0e3f7f-d67c-4b57-ab9c-f5ace656a5c3 France
0d3e7ed3-f3f8-40a7-be6a-fde380fd51a9 Poland
aa5cae51-448f-49b5-959b-27d210656d30 Netherlands
318b7b46-8b52-46ed-a033-b3658b42d95b Hungary
bc2657ad-c984-4580-b135-97a2eb0da5f4 Greece
9080824f-cd90-4c55-89b5-d49f7aec08ae Portugal
cc572f68-4e2e-40e9-9b17-4197da140731 Sweden
Certificates and Declarations
Container Information
box 1 piece
97 mm
30 mm
109 mm
0.144 kg
4016779876506
External Classifications and Standards
B
EC001441 - Phase monitoring relay
EC001441 - Phase monitoring relay
EC001441 - Phase monitoring relay
V11.0 : 27371803
39122332
2712285
4188095
3860614

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 83.26 %
Recycled Paper - 00 %
Recycled Cardboard - 92 %
Recycled Paper - 00 %
Recycled Paper - 00 %
Recycled Cardboard - 92 %
Recycled Paper - 00 %
Product Durability
Technical
Type A
10 kA
6 kA
Arbitrary
3
10000 cycle
20000 cycle
3
4P
Instantaneous
Right
Undelayed
None
Yes
Busbar 10 mm²
Rigid 25 ... 25 mm²
Flexible 25 ... 25 mm²
Busbar 10 mm²
Rigid 25 ... 25 mm²
Flexible 25 ... 25 mm²
1 - Solid-Core 25 … 25 mm²
4 - Multi-Wired 1 … 25 mm²
1 - Solid-Core 25 … 25 mm²
4 - Multi-Wired 1 … 25 mm²
Electrical
C
acc. to IEC 60898-1 415 V
acc. to IEC/EN 60664-1 500 V
4 kV
AC
32 A
30 mA
6 kA
10 kA
50 … 60 Hz
15.1 W
III
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20211115
True - contains substances > 0.1 mass percentage
20240429
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Consumer
Environmental
Dimensions
Engineering
Ordering
box 1 piece
0.530 kg
3211103
1683605
2160035
Certificates and Declarations
Installation
External Classifications and Standards
EC000905 - Earth leakage circuit breaker
EC000905 - Earth leakage circuit breaker
39121601
V11.0 : 27142207
4875 >> Residual current circuit breaker (RCCB)
F
IEC 61009-1
IEC 61009-2-1
EN 61009-1
EN 61009-2-1
IEC 61009-1
IEC 61009-2-1
EN 61009-1
EN 61009-2-1

Ordering
Popular Downloads
Dimensions
102 mm
123.5 mm
148 mm
1.8 kg
Technical
3
0
1
1
3P
Main Circuit 1000 V
Main Circuit 50 / 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
(690 V) 40 °C 160 A
(690 V) 55 °C 145 A
(690 V) 70 °C 130 A
(690 V) 40 °C 160 A
(690 V) 55 °C 145 A
(690 V) 70 °C 130 A
(415 V) 55 °C 110 A
(440 V) 55 °C 100 A
(500 V) 55 °C 100 A
(690 V) 55 °C 82 A
(1000 V) 55 °C 30 A
(380 / 400 V) 55 °C 110 A
(220 / 230 / 240 V) 55 °C 110
(415 V) 55 °C 110 A
(440 V) 55 °C 100 A
(500 V) 55 °C 100 A
(690 V) 55 °C 82 A
(1000 V) 55 °C 30 A
(380 / 400 V) 55 °C 110 A
(220 / 230 / 240 V) 55 °C 110
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
(415 V) 59 kW
(440 V) 59 kW
(500 V) 59 kW
(690 V) 75 kW
(1000 V) 40 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
(415 V) 59 kW
(440 V) 59 kW
(500 V) 59 kW
(690 V) 75 kW
(1000 V) 40 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
8 x Ie AC-3
10 x Ie AC-3
gG Type Fuses 200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 175 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 175 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Main Circuit 8 kV
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
10 million
3600 cycles per hour
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
at Rated Operating Conditions per Pole 3.6 W
Between Coil De-energization and NC Contact Closing 7 ... 15 ms
Between Coil De-energization and NO Contact Opening 10 ... 18 ms
Between Coil Energization and NC Contact Opening 7 ... 22 ms
Between Coil Energization and NO Contact Closing 10 ... 25 ms
Between Coil De-energization and NC Contact Closing 7 ... 15 ms
Between Coil De-energization and NO Contact Opening 10 ... 18 ms
Between Coil Energization and NC Contact Opening 7 ... 22 ms
Between Coil Energization and NO Contact Closing 10 ... 25 ms
Bar 30 mm²
Flexible with Cable End 2 x 6 ... 35 mm²
Rigid 1 x 10 ... 95 mm²
Bar 30 mm²
Flexible with Cable End 2 x 6 ... 35 mm²
Rigid 1 x 10 ... 95 mm²
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible 1x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible 1x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Bar 30 mm²
Flexible with Cable End 1 x 10 ... 70 mm²
Rigid 2 x 6 ... 65 mm²
Bar 30 mm²
Flexible with Cable End 1 x 10 ... 70 mm²
Rigid 2 x 6 ... 65 mm²
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
M8 hexagon socket screw with single connector
Main Circuit 8 N·m
Cable Clamp
Block Contactor
Technical UL/CSA
Main Circuit 600 V
(600 V AC) 140 A
(200 V AC) Three Phase 30 hp
(208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 100 hp
(200 V AC) Three Phase 30 hp
(208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 100 hp
(440 ... 480 V AC) Three Phase 96 A
(550 ... 600 V AC) Three Phase 99 A
(440 ... 480 V AC) Three Phase 96 A
(550 ... 600 V AC) Three Phase 99 A
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Without Derating 3000 m
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 10 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 10 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
Material Compliance
Following EU Directive 2011/65/EU
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
130 mm
265 mm
162 mm
2 kg
7320500141595
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4755 >> Contactors

AC Inverter for 55kW 400V 3 Ph motor to 100A at high overload or 75kW to 138A when Fan/Pump rated. Operates in VxF, Sensorless Vector or Full Closed-loop Flux Vector (when an optional Encoder Feedback card is fitted).

Ordering
1 piece
8536411090
Pluto
Programmable safety controller
Popular Downloads
Dimensions
120 mm
84 mm
90 mm
0.65 kg
Safety Information
Up to e
1
2
3
1
2
3
Technical
High
Failsafe 40
Failsafe (Transistor) 2
Failsafe (Relay) 4
Non-Failsafe 16
Failsafe (Transistor) 2
Failsafe (Relay) 4
Non-Failsafe 16
MODBUS ASCII, StatusBus
24 V DC
24 V DC
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
90 mm
130 mm
105 mm
0.7 kg
7320500410622
External Classifications and Standards
V11.0 : 27242207
EC000236 - PLC CPU-module
EC000236 - PLC CPU-module
EC000236 - PLC CPU-module
3561 >> Programmable Logic Controller Module
32151705
K
2712159
3860084

Ordering
1 piece
85371091
Popular Downloads
Dimensions
150 mm
314 mm
198 mm
4.6 kg
Technical
208 ... 600 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 12.5 kW
(400 V) 22 kW
(500 V) 25 kW
(230 V) 12.5 kW
(400 V) 22 kW
(500 V) 25 kW
45 A
at 230 V 25 kW
at 400 V 37 kW
at 500 V 45 kW
at 230 V 25 kW
at 400 V 37 kW
at 500 V 45 kW
76 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Cable Clamp
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 8 N·m
PSTX45
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 15 Hp
(440 ... 480 V AC) Three Phase 30 Hp
(550 ... 600 V AC) Three Phase 40 Hp
(200 ... 208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 15 Hp
(440 ... 480 V AC) Three Phase 30 Hp
(550 ... 600 V AC) Three Phase 40 Hp
Main Circuit 600 V
Main Circuit 70.8
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
e1fe3351-a6ac-4cbd-aebf-814f3a66a5bc China
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
200 mm
282 mm
388 mm
5.6 kg
7320500501337
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
8536411090
Pluto
Programmable safety controller
Popular Downloads
Dimensions
120 mm
84 mm
90 mm
0.65 kg
Safety Information
Up to e
1
2
3
1
2
3
Technical
High
Failsafe 40
Failsafe (Transistor) 2
Failsafe (Relay) 4
Non-Failsafe 16
Failsafe (Transistor) 2
Failsafe (Relay) 4
Non-Failsafe 16
MODBUS ASCII, Pluto Safety Bus, StatusBus
24 V DC
24 V DC
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
90 mm
130 mm
105 mm
0.7 kg
7320500410615
External Classifications and Standards
V11.0 : 27242207
EC000236 - PLC CPU-module
EC000236 - PLC CPU-module
EC000236 - PLC CPU-module
3561 >> Programmable Logic Controller Module
32151705
K
2712156
3860083

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
Ordering
10 piece
85365080
Finland
Dimensions
70 mm
91.5 mm
72.5 mm
0.31 kg
Container Information
box 1 piece
84 mm
103 mm
82 mm
0.34 kg
6417019393094
Technical
Cu 1.5 ... 35 mm²
Flexible with Ferrule 1x Cu 1.5…4 mm²
Solid 1x Cu 1.5…6 mm²
Flexible 1x Cu 1.5…35 mm²
Stranded 1x Cu 1.5…35 mm²
Flexible with Ferrule 1x Cu 1.5…4 mm²
Solid 1x Cu 1.5…6 mm²
Flexible 1x Cu 1.5…35 mm²
Stranded 1x Cu 1.5…35 mm²
Θ = 40 °C 63 A
Fully Enclosed 63 A
Front IP20
Standard
Right Side
Switched - Simultaneous Function
Knob
Handle and shaft not included
Knob
Handle and shaft not included
20000
Base mounting
4P
Front operated
3
Top In - Bottom Out
Bottom In - Top Out
Top In - Bottom Out
Bottom In - Top Out
at Rated Operating Conditions per Pole 2.8 W
(100 A fuse, ≤415 V) 50 kA
(100 A fuse, 500 V) 100 kA
(80 A fuse, 690 V) 50 kA
(100 A fuse, ≤415 V) 50 kA
(100 A fuse, 500 V) 100 kA
(80 A fuse, 690 V) 50 kA
8 kV
acc. to IEC/EN 60664-1 750 V
(380 ... 415 V) 63 A
(500 V) 63 A
(690 V) 63 A
(380 ... 415 V) 63 A
(500 V) 63 A
(690 V) 63 A
(380 ... 415 V) 63 A
(500 V) 63 A
(690 V) 63 A
(380 ... 415 V) 63 A
(500 V) 63 A
(690 V) 63 A
(380 ... 415 V) 63 A
(500 V) 45 A
(690 V) 20 A
(380 ... 415 V) 63 A
(500 V) 45 A
(690 V) 20 A
(220 ... 240 V) 11 kW
(400 ... 415 V) 22 kW
(500 V) 22 kW
(690 V) 15 kW
(220 ... 240 V) 11 kW
(400 ... 415 V) 22 kW
(500 V) 22 kW
(690 V) 15 kW
Main Circuit 750 V
(690 V) 2.1 kA
for 1 s 1.5 kA
Main Circuit Pozidriv 2
No
IEC 60947-3 / UL 508 / CSA C22.2 No. 14
Mechanism on Top of the Switch
Screw Terminals
acc. IEC 60947-1 2 N·m
Main Circuit 10-12 mm
Technical UL/CSA
600 V
60 A
(110 ... 120 V AC) Single Phase 2 Hp
(240 V AC) Single Phase 7.5 Hp
(440 ... 480 V AC) Single Phase 15 Hp
(550 ... 600 V AC) Single Phase 15 Hp
(220 ... 240 V AC) Three Phase 15 Hp
(440 ... 480 V AC) Three Phase 30 Hp
(550 ... 600 V AC) Three Phase 30 Hp
(110 ... 120 V AC) Single Phase 2 Hp
(240 V AC) Single Phase 7.5 Hp
(440 ... 480 V AC) Single Phase 15 Hp
(550 ... 600 V AC) Single Phase 15 Hp
(220 ... 240 V AC) Three Phase 15 Hp
(440 ... 480 V AC) Three Phase 30 Hp
(550 ... 600 V AC) Three Phase 30 Hp
Main Circuit 10-12 mm
Main Circuit Pozidriv 2
acc. IEC 60947-1 2 N·m
18 in·lb
Certificates and Declarations
External Classifications and Standards
Q
EC000216 - Switch disconnector (low voltage)
EC000216 - Switch disconnector (AC)
39122233
5290 >> Disconnect switch
V11.1 : 27371403
5. Small Equipment (No External Dimension More Than 50 cm)
3601451
4363527
3171070

AC Inverter for 0.55kW (0.75HP) 400V 3 Ph motor to 1.8A at high overload or 0.75kW (1HP) to 2.5A when Fan/Pump rated.