Variable Frequency Drives

25001 products

Showing 217 - 240 of 25001 products

Showing 217 - 240 of 25001 products
View
6SL3210-1PE22-7AL0 Siemens
Siemens 6SL3210-1PE22-7AL0 Siemens
Sale price 7,984.00 kr
Only 1 unit left
Product
Article Number (Market Facing Number) 6SL32101PE227AL0 | 6SL32101PE227AL0
Product Description SINAMICS g120 power module pm24 built in cl. a filter with buil braking chopper 3AC380-480v +10 47-63HZ output high overload 7, 200% 3s,150% 57s,100% 240s ambi -10 to +50 deg c output low ove 11KW for 150% 3s,110% 57s,100% ambient temp -10 to +40 deg c 3 x 165 (hxwxd), fsc protection I without control unit and panel for firmware- version v4.6
Product family Ordering Data Overview
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4042948666098
UPC 887621780036
Commodity Code 85044095
LKZ_FDB/ CatalogID D11.1SD
Product Group 9772
Group Code R220
Country of origin Great Britain
SCIP number Not available
Delivery information
Net Weight (lb) 11.685 lb
Package size unit of measure Inch
Packaging Quantity 1
6SL3210-5BE24-0UV0 Siemens
Siemens 6SL3210-5BE24-0UV0 Siemens
Sale price 3,133.00 kr
Only 10 units left
Product
Article Number (Market Facing Number) 6SL32105BE240UV0 | 6SL32105BE240UV0
Product Description SINAMICS V20 380-480 V 3 AC -15/+10% 47-63Hz rated power 4 kW with 150% overload for 60 sec. unfiltered I/O: 4 DI, 2 DO,2 AI, 1 AQ fieldbus: USS/MODBUS RTU with built-in BOP protection: IP20/ UL open size: B 140x160x165 (WxHxD)
Product family SINAMICS V20 basic converters
Product Lifecycle (PLM) PM400:Announcement of product phase-out
Additional Product Information
EAN 6940408102767
UPC 887621056247
Commodity Code 85044095
LKZ_FDB/ CatalogID SINAMICS V20
Product Group 5681
Group Code R220
Country of origin China
SCIP number Not available
Delivery information
Net Weight (lb) 3.549 lb
Package size unit of measure Inch
Packaging Quantity 1
6SL3210-1PE28-8UL0 Siemens
Siemens 6SL3210-1PE28-8UL0 Siemens
Sale price 22,338.00 kr
In stock, 12 units
Product
Article Number (Market Facing Number) 6SL32101PE288UL0 | 6SL32101PE288UL0
Product Description SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 45kW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 551 X 275 X 237 (HXWXD), FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 HF8
Product family Ordering Data Overview
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4042948668108
UPC 804766090899
Commodity Code 85044095
LKZ_FDB/ CatalogID D11.1SD
Product Group 9775
Group Code R220
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 58.202 lb
Package size unit of measure Inch
Packaging Quantity 1
6SL3100-0BE21-6AB0 Siemens
Siemens 6SL3100-0BE21-6AB0 Siemens
Sale price 15,634.00 kr
In stock, 19 units
Product
Article Number (Market Facing Number) 6SL31000BE216AB0 | 6SL31000BE216AB0
Product Description SINAMICS S120 ACTIVE INTERFACE MODULE FOR 16KW ACTIVE LINE MODULE INPUT: 3AC 380-480V, 50/60HZ FRAME SIZE: BOOKSIZE
Product family Ordering Data Overview
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4042948662939
UPC 662643344943
Commodity Code 85363030
LKZ_FDB/ CatalogID D21MC
Product Group 9617
Group Code R220
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 28.660 lb
Package size unit of measure Not available
Packaging Quantity 1
VFD015EL21W Delta
Delta VFD015EL21W Delta
Sale price 1,913.00 kr
Only 10 units left

Delta’s VFD-EL-W series is the new generation compact vector control drive. Simple, delicate and durable design inherits Delta’s superior drive technology. Various essential functions are built-in as standard, including: Multi-step Operation; Torque Compensation; PID Control; Multi-Pump Control; Water Supply at Constant Pressure; Leakage Detection function and so on. 1.2 KW – 2 HP – 7.5 A 230 V – 1 Phase

Delta New Stock Image
Delta VFD2A7MS43ANSAA Delta
Sale price 2,265.00 kr
Only 9 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

ACS55-01E-02A2-2 ABB
ABB ACS55-01E-02A2-2 ABB
Sale price 7,860.00 kr
Only 1 unit left

Inverter Drive, 1-Phase In, 130Hz Out 0.37 kW, 230 V, 2.2 A ACS55, IP20

ACS355-03U-24A4-2 - ABB
ABB ACS355-03U-24A4-2 - ABB
Sale price 20,404.00 kr
Only 3 units left

Variable Frequency Drive, 208 – 240 VAC 3 Phase Input, 240 VAC 3 Phase Output, 22.0 Amps

1SAM350000R1006 ABB - MS132-1.6
ABB 1SAM350000R1006 ABB - MS132-1.6
Sale price 1,240.00 kr
Only 6 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362010

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals (Part 2):

Dimensions

Product Net Width:
45 mm
Product Net Height:
90 mm
Product Net Depth / Length:
86.75 mm
Product Net Weight:
0.265 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics):
(230 V AC) 100 kA
(250 V DC) 3 Poles in Series 10 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
(230 V AC) 100 kA
(250 V DC) 3 Poles in Series 10 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii):
20 A
Setting Range:
1.0 ... 1.6 A
Rated Operational Power AC-3 (Pe):
(400 V) Three Phase 0.55 kW
Rated Operational Power AC-3e (Pe):
(400 V) Three Phase 0.55 kW
Rated Operational Voltage:
Main Circuit 690 V AC
Main Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 250 V DC
Rated Operational Current (Ie):
1.6 A
Rated Operational Current AC-3 (Ie):
1.6 A
Rated Operational Current AC-3e (Ie):
1.6 A
Rated Operational Current DC-5 (Ie):
1.6 A
Rated Frequency (f):
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
Operating Frequency (fsw):
0 ... 400 Hz
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 6 kV
Rated Insulation Voltage (Ui):
690 V
Power Loss:
at Rated Operating Conditions per Pole 0.6 ... 1.7 W
Number of Poles:
3P
Conventional Free-air Thermal Current (Ith):
Main Circuit 1.6 A
Degree of Protection:
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
Pollution Degree:
3
Electrical Durability:
50000 cycle
Mechanical Durability:
Nr. Operations 100000 cycle
Terminal Type:
Screw Terminals
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Tightening Torque:
Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length:
Main Circuit 9 mm
Recommended Screw Driver:
Pozidriv 2
Mounting Position:
1 ... 6
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance:
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type:
Rotary Handle
Contact Position Indication:
ON / OFF / TRIP
Standards:
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Remarks:
UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx

Technical UL/CSA

Short-Circuit Current Rating (SCCR):
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V AC
Horsepower Rating UL/CSA:
(440 ... 480 V AC) Three Phase 0.75 Hp
(550 ... 600 V AC) Three Phase 0.75 Hp
(440 ... 480 V AC) Three Phase 0.75 Hp
(550 ... 600 V AC) Three Phase 0.75 Hp
Full Load Amps Motor Use:
(200 V AC) Three Phase 1.6 A
(208 V AC) Three Phase 1.6 A
(220 ... 240 V AC) Three Phase 1.6 A
(440 ... 480 V AC) Three Phase 1.6 A
(200 V AC) Three Phase 1.6 A
(208 V AC) Three Phase 1.6 A
(220 ... 240 V AC) Three Phase 1.6 A
(440 ... 480 V AC) Three Phase 1.6 A
Locked Rotor Amps:
(200 V AC) Three Phase 9.6 A
(208 V AC) Three Phase 9.6 A
(220 ... 240 V AC) Three Phase 9.6 A
(440 ... 480 V AC) Three Phase 9.6 A
(550 ... 600 V AC) Three Phase 9.6 A
(200 V AC) Three Phase 9.6 A
(208 V AC) Three Phase 9.6 A
(220 ... 240 V AC) Three Phase 9.6 A
(440 ... 480 V AC) Three Phase 9.6 A
(550 ... 600 V AC) Three Phase 9.6 A
General Use Rating UL/CSA:
(600 V AC) 1.6 A
Connecting Capacity Main Circuit UL/CSA:
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSA:
Main Circuit 10 ... 12 in·lb

Environmental

Ambient Air Temperature:
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation:
Yes
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 25g
Resistance to Vibrations:
5g 3 ... 150 Hz

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Certificates and Declarations

LR Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
95 mm
Package Level 1 Height:
50 mm
Package Level 1 Gross Weight:
0.28 kg
Package Level 1 EAN:
4013614400063
Package Level 2 Units:
carton 40 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
11.586 kg
Package Level 2 EAN:
4013614408960

External Classifications and Standards

Object Classification Code:
F
ETIM 9:
EC000074 - Motor protection circuit-breaker
ETIM 10:
EC000074 - Motor protection circuit-breaker
eClass:
V11.0 : 27370401
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4731 >> Manual Starters
E-Number (Finland):
3705990
E-Number (Norway):
4364075
E-Number (Sweden):
3112122
1SFA897107R7000 ABB
ABB 1SFA897107R7000 ABB
Sale price 10,494.00 kr
Only 9 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85371091

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals:
Instructions and Manuals (Part 3):
EPLAN Data:
Wiring Diagram:

Dimensions

Product Net Width:
90 mm
Product Net Height:
245 mm
Product Net Depth / Length:
184 mm
Product Net Weight:
2.5 kg

Technical

Rated Operational Voltage:
208 ... 600 V AC
Rated Control Supply Voltage (Us):
100 ... 250 V AC
Rated Control Circuit Voltage (Uc):
24 V DC
Rated Frequency (f):
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe):
(230 V) 18.5 kW
(400 V) 37 kW
(500 V) 45 kW
(230 V) 18.5 kW
(400 V) 37 kW
(500 V) 45 kW
Rated Operational Current - In-Line Connection (Ie):
72 A
Service Factor Percentage:
100 %
Overload Protection:
Build-in electronic overload protection
Integrated Electronic Overload:
Yes
Starting Capacity at Maximum Rated Current Ie:
4xIe for 10s
Ramp Time:
0 ... 30 second [unit of time]
1 ... 30 second [unit of time]
0 ... 30 second [unit of time]
1 ... 30 second [unit of time]
Initial Voltage During Start:
30 ... 70 %
Step Down Voltage Special Ramp:
No %
Current Limit Function:
1.5 ... 7xIe
Switch for Inside Delta Connection:
No
Run Signal Relay:
Yes
By-pass Signal Relay:
Yes
Fault Signal Relay:
Yes
Overload Signal Relay:
Yes
Analog Outputs:
4…20 mA
Signal Indication Completed Start Ramp (LED):
Green
Signal Indication Ready to Start/Standby ON (LED):
Green
Signal Indication Running R (LED):
Green
Signal Indication Ramping Up/Down (LED):
Green
Signal Indication Protection (LED):
Yellow
Signal Indication Fault (LED):
Red
Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:
10
Communication:
Modbus-RTU
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:
Screw Terminals
Connecting Capacity Main Circuit:
Hole Diameter 8.5 mm
Rigid 1/2 x 2.5 ... 70 mm²
Width and Thickness 17.5x5 mm
Hole Diameter 8.5 mm
Rigid 1/2 x 2.5 ... 70 mm²
Width and Thickness 17.5x5 mm
Connecting Capacity Control Circuit:
Rigid 1 x 2.5 mm²
Rigid 2 x 1.5 mm²
Rigid 1 x 2.5 mm²
Rigid 2 x 1.5 mm²
Connecting Capacity Supply Circuit:
Rigid 1 x 2.5
Tightening Torque:
Control Circuit 0.5 N·m
Main Circuit 9 N·m
Supply Circuit 0.5 N·m
Control Circuit 0.5 N·m
Main Circuit 9 N·m
Supply Circuit 0.5 N·m
Product Main Type:
PSE72
Function:
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Kick start
Sequence start
Current limit
Start reverse (external contactors)
Automatic restart
Event log
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Kick start
Sequence start
Current limit
Start reverse (external contactors)
Automatic restart
Event log
Protection Function:
Electronic overload protection, EOL; Locked rotor protection; Current underload protection

Technical UL/CSA

Horsepower Rating UL/CSA:
(200 ... 208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 25 Hp
(440 ... 480 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 60 Hp
(200 ... 208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 25 Hp
(440 ... 480 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 60 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
Tightening Torque UL/CSA:
Control Circuit 4.4 in·lb
Main Circuit 79.7
Supply Circuit 4.4 in·lb
Control Circuit 4.4 in·lb
Main Circuit 79.7
Supply Circuit 4.4 in·lb

Environmental

Ambient Air Temperature:
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
8462d3d9-3bdb-42b0-9715-4ea626c99564 Sweden
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Container Information

Package Level 1 Width:
178 mm
Package Level 1 Depth / Length:
257 mm
Package Level 1 Height:
288 mm
Package Level 1 Gross Weight:
3.2 kg
Package Level 1 EAN:
7320500400654
Package Level 1 Units:
box 1 piece

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000640 - Soft starter
ETIM 8:
EC000640 - Soft starter
ETIM 9:
EC000640 - Soft starter
eClass:
V11.0 : 27370907
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4740 >> Soft starter
ABB New Stock Image
ABB ACH-CP-B ABB
Sale price 1,725.00 kr
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
6SL3210-5BB21-1UV1 Siemens
Siemens 6SL3210-5BB21-1UV1 Siemens
Sale price 2,414.00 kr
Only 5 units left
Product
Article Number (Market Facing Number) 6SL32105BB211UV1 | 6SL32105BB211UV1
Product Description SINAMICS V20 200-240V 1AC -10/+10% 47-63Hz rated power 1.1 kW with 150% overload for 60 sec. unfiltered I/O: 4 DI, 2 DO,2 AI, 1 AQ fieldbus: USS/MODBUS RTU with built-in BOP protection: IP20/ UL open size: AC 90x160x147(WxHxD)
Product family SINAMICS V20 basic converters
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4042948676950
UPC 804766663154
Commodity Code 85044095
LKZ_FDB/ CatalogID SINAMICS V20
Product Group 5680
Group Code R220
Country of origin China
SCIP number Not available
Delivery information
Net Weight (lb) 2.646 lb
Package size unit of measure Inch
Packaging Quantity 1
FR-A840-00620-2-60 Mitsubishi
Mitsubishi FR-A840-00620-2-60 Mitsubishi
Sale price 16,497.00 kr
Only 6 units left

Inverter AC; Pn: 18,5-30kW; 3x380-500V;In max: 62A;(22kW; 44A); IP20

3AUA0000036521 ABB - RDCU-12C
ABB 3AUA0000036521 ABB - RDCU-12C
Sale price 58,390.00 kr
In stock, 16 units

Drive Control unit+cables RDCU-12C+cables. ACS800-04M-0550-5+E202+E208+H360+J400+K458+P901+P916+P920+OR715

ACS580-01-033A-4 ABB
ABB ACS580-01-033A-4 ABB
Sale price 11,464.00 kr
In stock, 13 units

ACS580 IP21 11kW/15kW 400V 3ph AC Inverter, HMI, DBr, STO, C2 EMC

ABB New Stock Image
ABB A185-30-11-84 ABB
Sale price 4,831.00 kr
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB RPBA-01 ABB
Sale price 4,598.00 kr
In stock, 16 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
1SFL427001R1311 ABB - AF116-30-11-13
ABB 1SFL427001R1311 ABB - AF116-30-11-13
Sale price 2,737.00 kr
Only 8 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
90 mm
Product Net Depth / Length:
126 mm
Product Net Height:
150 mm
Product Net Weight:
1.55 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Number of Poles:
3P
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 160 A
(690 V) 60 °C 145 A
(690 V) 70 °C 130 A
(690 V) 40 °C 160 A
(690 V) 60 °C 145 A
(690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie):
(415 V) 55 °C 116 A
(440 V) 55 °C 116 A
(500 V) 55 °C 110 A
(690 V) 55 °C 65 A
(380 / 400 V) 55 °C 116 A
(220 / 230 / 240 V) 55 °C 116 A
(415 V) 55 °C 116 A
(440 V) 55 °C 116 A
(500 V) 55 °C 110 A
(690 V) 55 °C 65 A
(380 / 400 V) 55 °C 116 A
(220 / 230 / 240 V) 55 °C 116 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 116 A
(440 V) 60 °C 116 A
(500 V) 60 °C 110 A
(690 V) 60 °C 65 A
(380 / 400 V) 60 °C 116 A
(220 / 230 / 240 V) 60 °C 116 A
(415 V) 60 °C 116 A
(440 V) 60 °C 116 A
(500 V) 60 °C 110 A
(690 V) 60 °C 65 A
(380 / 400 V) 60 °C 116 A
(220 / 230 / 240 V) 60 °C 116 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Power AC-3 (Pe):
(415 V) 55 kW
(440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
(415 V) 55 kW
(440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
Rated Operational Power AC-3e (Pe):
(415 V) 55 kW
(440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
(415 V) 55 kW
(440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-3:
8 x Ie AC-3
Rated Breaking Capacity AC-3e:
8.5 x Ie AC-3e
Rated Making Capacity AC-3:
10 x Ie AC-3
Rated Making Capacity AC-3e:
12 x Ie AC-3e
Short-Circuit Protective Devices:
gG Type Fuses 250 A
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1000 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 8 kV
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
Mechanical Durability:
5 million
Maximum Mechanical Switching Frequency:
300 cycles per hour
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc):
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A
Holding at Max. Rated Control Circuit Voltage DC 3 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 135 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A
Holding at Max. Rated Control Circuit Voltage DC 3 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 135 W
Power Loss:
at Rated Operating Conditions per Pole 6 W
Operate Time:
Between Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
Between Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
Connecting Capacity Main Circuit:
Flexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
Flexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Connecting Capacity:
Flexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
Flexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque:
Cable Lug 9 N·m
Main Circuit 8 N·m
Cable Lug 9 N·m
Main Circuit 8 N·m
Terminal Type:
Double Clamp
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 160 A
Horsepower Rating UL/CSA:
(200 V AC) Three Phase 30 hp
(208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 100 hp
(200 V AC) Three Phase 30 hp
(208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 100 hp
Full Load Amps Motor Use:
(440 ... 480 V AC) Three Phase 96 A
(550 ... 600 V AC) Three Phase 99 A
(440 ... 480 V AC) Three Phase 96 A
(550 ... 600 V AC) Three Phase 99 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible:
Without Derating 3000 m

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
Improved Energy Efficiency for Customers:
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 37 %

Certificates and Declarations

CB Certificate:
Declaration of Conformity - UKCA:
EAC Certificate:
RMRS Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
207 mm
Package Level 1 Depth / Length:
216 mm
Package Level 1 Height:
150 mm
Package Level 1 Gross Weight:
1.75 kg
Package Level 1 EAN:
7320500476376

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3706167
E-Number (Norway):
4117610
E-Number (Sweden):
3210068
ACS310-03E-34A1-4 ABB
ABB ACS310-03E-34A1-4 ABB
Sale price 15,566.00 kr
Only 10 units left

ACS310 HVAC IP20 15kW 400V 3ph AC Inverter Drive, C3 EMC

CIPRGA50U4012ABAA Yaskawa
Yaskawa CIPRGA50U4012ABAA Yaskawa
Sale price 4,579.00 kr
Only 2 units left

Yaskawa GA50U4012ABA 480 Volt Three Phase 11.9 Amp 7.5 HP Microdrive

6SL3210-5FB10-2UF2 Siemens
Siemens 6SL3210-5FB10-2UF2 Siemens
Sale price 3,285.00 kr
Only 5 units left
Product
Article Number (Market Facing Number) 6SL32105FB102UF2 | 6SL32105FB102UF2
Product Description SINAMICS V90, with PROFINET Input voltage: 200-240 V 1/3-phase AC -15%/+10% 3.0/1.8 A 45-66 Output voltage: 0 – Input voltage: 1.4 A 0-330 Hz Motor: 0.2 kW Degree of protection: IP20 Size A, 45x170x170 (WxHxD)
Product family SINAMICS V90 servo drive
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4042948692189
UPC 804766815461
Commodity Code 85044095
LKZ_FDB/ CatalogID SINAMICS V90
Product Group 4R31
Group Code R220
Country of origin China
SCIP number Not available
Delivery information
Net Weight (lb) 2.425 lb
Package size unit of measure Inch
Packaging Quantity 1
6SE6440-2UC13-7AA1 Siemens
Siemens 6SE6440-2UC13-7AA1 Siemens
Sale price 4,803.00 kr
Only 5 units left
Product
Article Number (Market Facing Number) 6SE64402UC137AA1 | 6SE64402UC137AA1
Product Description
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
Additional Product Information
EAN 4019169450041
UPC 783087635258
Commodity Code 85044085
LKZ_FDB/ CatalogID DA51-D
Product Group 9848
Group Code R2S3
Country of origin Great Britain
SCIP number 461efd93-5ff4-4e57-855e-e7631d1d0ae0
Delivery information
Net Weight (lb) 2.866 lb
Package size unit of measure Inch
Packaging Quantity 1
6SE6440-2UD15-5AA1 Siemens
Siemens 6SE6440-2UD15-5AA1 Siemens
Sale price 6,347.00 kr
In stock, 15 units
Product
Article Number (Market Facing Number) 6SE64402UD155AA1 | 6SE64402UD155AA1
Product Description
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
Additional Product Information
EAN 4019169450324
UPC 783087635678
Commodity Code 85044095
LKZ_FDB/ CatalogID DA51-E
Product Group 9848
Group Code R2S3
Country of origin Great Britain
SCIP number Not available
Delivery information
Net Weight (lb) 2.866 lb
Package size unit of measure Inch
Packaging Quantity 1
6SL3210-1PE31-8UL0 Siemens
Siemens 6SL3210-1PE31-8UL0 Siemens
Sale price 48,741.00 kr
Only 10 units left
Product
Article Number (Market Facing Number) 6SL32101PE318UL0 | 6SL32101PE318UL0
Product Description SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 75KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 90kW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 708 X 305 X 357 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 HF8
Product family Ordering Data Overview
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4042948668139
UPC 804766231810
Commodity Code 85044095
LKZ_FDB/ CatalogID D11.1SD
Product Group 9775
Group Code R220
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 127.868 lb
Package size unit of measure Inch
Packaging Quantity 1

Recently viewed