30mm push button range is robust and offers long term reliability in heavy duty industrial applications and extreme environments. The 9001K operator have a metal operator base and the 9001SK operators have a plastic base. This very broad line of push button operators includes push buttons, emergency stop mushroom head push buttons, selector switches, key operated switches, and operators with potentiometers. Also includes pilot lights (LED, incandescent and neon), joystick controllers, wobble stick operators, and operators with multiple functions. These operators can be purchased as complete operators or as subassemblies that can be assembled by the user to meet specific requirements. The 9001 K metal 30mm push buttons are automatic selfgrounding operators requiring no additional wiring and are ABS Certified. It is compatible with Harmony 9001K push buttons and switches. Contact blocks have terminal screw shipped back out to speed wiring and has a very large variety of accessories. Some operators have super bright LEDs for high visibility. These operators are IP 66, NEMA 4 rated (heavy duty, oil tight, water proof and dust tight without requiring boots). The 9001SK operators are also NEMA 4X corrosion resistant. The 9001K and 9001SK 30mm push button operators conforms to IEC, UL, CSA, EN and NOM standards. They are CE marked. 30mm Push Buttons are used in the automotive, machine tool, crane and hoist, food and beverage, industrial applications, material handling, petrochemical, wastewater treatment, metallurgy and many more industries.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Harmony 9001K Harmony 9001SK |
| Product or Component Type | Contact block |
| Device short name | 9001K |
| Contacts type and composition | 1 C/O |
Complementary
| Characteristic | Value(s) |
|---|---|
| Product Weight | 0.060 lb(US) (0.027 kg) |
| Contact operation | Positive opening |
| Positive opening | Without |
| Connections - terminals | Screw clamp terminals, 1 x 0.22...2 x 2.5 mm² IEC 60947-1 |
| Tightening torque | 7.08 lbf.in (0.8 N.m) IEC 60947-1 |
| Shape of screw head | Cross slotted |
| Contacts material | Silver alloy contacts |
| Short-circuit protection | 10 A cartridge fuse IEC 60947-5-1 |
| [Ith] conventional free air thermal current | 10 A |
| [Ui] rated insulation voltage | 250 V 3)IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 2.5 kV IEC 60947-1 |
| [Ie] rated operational current | 3 A 240 V, AC-15, A600-Q600 NEMA 0.55 A 125 V, DC-13, A600-Q600 NEMA |
| [Icm] rated short-circuit making capacity | 12 kA 600 V AC-15, 7200 VA 15 kA 480 V AC-15, 7200 VA 30 kA 240 V AC-15, 7200 VA 60 kA 120 V AC-15, 7200 VA 0.1 kA 600 V DC-13, 7200 VA 0.27 kA 250 V DC-13, 7200 VA 0.55 kA 125 V DC-13 |
| Rated breaking capacity | 3 kA 240 V AC-15, 720 VA 6 kA 120 V AC-15, 720 VA 1.2 kA 600 V AC-15, 720 VA 1.5 kA 480 V AC-15, 720 VA 0.1 kA 600 V DC-13 0.27 kA 250 V DC-13 0.55 kA 125 V DC-13 |
| [Us] rated supply voltage | 0...600 V |
| Connections - Terminals | Screw-clamp terminals |





VigiPacT RH99M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 12/24VAC 50/60Hz, or 12/48VDC. The current sensitivity is selectable with 9 thresholds from 30 mA to 30 A. The time delay is selectable with 9 settings from instantaneous to 4.5s. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.
Main
| Characteristic | Value(s) |
|---|---|
| Range | VigiPacT |
| Device short name | RH99M |
| Product or Component Type | Residual current protection relay |
| Relay application | Protection relay |
| Mounting Support | DIN rail |
| Earth-leakage protection class | Type A |
| Type of setting | Selector |
| Residual earth-leakage sensitity adjustment type | Adjustable 9 settings |
| Earth-leakage sensitivity | 0.03â¦30 A |
| Earth-leakage time delay | Instantaneous for 0.03 A Adjustable 9 settings 0â¦4.5 s for 0.03â¦30 A |
| Current sensors compatibility | VigiPacT TOA earth leakage current sensor VigiPacT A earth leakage current sensor VigiPacT L earth leakage current sensor |
| [Ithe] conventional enclosed thermal current | 8 A |
| Minimum load | 10 mA 12 V |
| [Us] rated supply voltage | 12...24 V AC 50/60 Hz 55...120 % 12...48 V DC 55...120 % |
| Power Consumption in VA | 4 VA |
| Monitored distribution system | 1000 V - AC 50/60 Hz maximum) 1000 V - AC 400 Hz maximum) |
| Earthing system | TN-S IT TT |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Reset | Manual reset |
Complementary
| Characteristic | Value(s) |
|---|---|
| Test function | Remote test Local |
| Monitoring | Electronics continuous) Power supply continuous) Relay/sensor link continuous) |
| Type of measurement | Earth fault current internal measurement 80...100 % |
| Tamperproof of settings | Protected by sealable cover |
| Connections - terminals | Auxiliary power supply terminal block 0.0003â¦0.004 in² (0.2â¦2.5 mm²) flexible AWG 24...AWG 12 Auxiliary power supply terminal block 0.0003â¦0.004 in² (0.2â¦2.5 mm²) rigid AWG 24...AWG 12 Auxiliary power supply terminal block 0.0004â¦0.004 in² (0.25â¦2.5 mm²) flexible AWG 24...AWG 12 Fault screw terminal 0.0003â¦0.004 in² (0.2â¦2.5 mm²) flexible AWG 24...AWG 12 Fault screw terminal 0.0003â¦0.006 in² (0.2â¦4 mm²) rigid AWG 24...AWG 12 Fault screw terminal 0.0004â¦0.004 in² (0.25â¦2.5 mm²) flexible AWG 24...AWG 12 Relay test and fault reset screw terminal 0.0002â¦0.002 in² (0.14â¦1 mm²) flexible AWG 26...AWG 16 Relay test and fault reset screw terminal 0.0002â¦0.002 in² (0.14â¦1.5 mm²) rigid AWG 26...AWG 16 Relay test and fault reset screw terminal 0.0004â¦0.0008 in² (0.25â¦0.5 mm²) flexible AWG 26...AWG 16 Sensor screw terminal 0.0002â¦0.002 in² (0.14â¦1 mm²) flexible AWG 26...AWG 16 Sensor screw terminal 0.0002â¦0.002 in² (0.14â¦1.5 mm²) rigid AWG 26...AWG 16 Sensor screw terminal 0.0004â¦0.0008 in² (0.25â¦0.5 mm²) flexible AWG 26...AWG 16 Voltage presence screw terminal 0.0003â¦0.004 in² (0.2â¦2.5 mm²) flexible AWG 24...AWG 12 Voltage presence screw terminal 0.0003â¦0.006 in² (0.2â¦4 mm²) rigid AWG 24...AWG 12 Voltage presence screw terminal 0.0004â¦0.004 in² (0.25â¦2.5 mm²) flexible AWG 24...AWG 12 |
| Wire stripping length | Auxiliary power supply: 0.3 in (7 mm) for top connection Fault: 0.3 in (8 mm) for bottom connection Relay test and fault reset: 0.2 in (5 mm) for bottom connection Sensor: 0.2 in (5 mm) for top connection Voltage presence: 0.3 in (8 mm) for bottom connection |
| Tightening torque | Auxiliary power supply: 5.3 lbf.in (0.6 N.m) top Fault: 5.3 lbf.in (0.6 N.m) bottom Relay test and fault reset: 2.21 lbf.in (0.25 N.m) bottom Sensor: 2.21 lbf.in (0.25 N.m) top Voltage presence: 5.3 lbf.in (0.6 N.m) bottom |
| 9 mm pitches | 6 |
| Standards | EN/IEC 60947-2 Annex M EN/IEC 60755 UL 1053 CAN/CSA C22.2 No. 144 |
| Width | 2.1 in (54 mm) |
| Height | 3.2 in (81 mm) |
| Depth | 2.9 in (74 mm) |
| Product Weight | 0.7 lb(US) (0.3 kg) |
| IP degree of protection | IP40 on front face: conforming to EN/IEC 60529 IP30 on side parts: conforming to EN/IEC 60529 IP20 on connection terminals: conforming to EN/IEC 60529 |
| IK degree of protection | IK07 conforming to EN 50102 |
| Mechanical robustness | Fire resistance IEC 60695-2-1 IK protection 2 joulesIK07 EN 50102 Vibrations 13.2...100 Hz0.7 g Vibrations 2...13.2 Hz+/- 1 mm |

Main
| Characteristic | Value(s) |
|---|---|
| Range | MasterPacT |
| product name | MasterPact NW |
| Circuit breaker name | MasterPact NW16H1 |
| Product or component type | Circuit breaker |
| Device application | Power distribution protection |
| Poles description | 3P |
| Control unit | Without control unit |
| [In] rated current | 1600 A at 40 °C |
| Performance type | H1 65 kA 440 V AC |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Selectivity category | Category B |
| control type | Push-button |
| Mounting mode | Drawout |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Icu] rated ultimate short-circuit breaking capacity | 65 kA at 220/415 V AC 50/60 Hz 65 kA at 440 V AC 50/60 Hz 65 kA at 525 V AC 50/60 Hz 65 kA at 690 V AC 50/60 Hz |
| [Ics] rated service breaking capacity | 65 kA at 220/415 V AC 50/60 Hz 65 kA at 440 V AC 50/60 Hz 65 kA at 525 V AC 50/60 Hz 65 kA at 690 V AC 50/60 Hz |
| [Icw] rated short-time withstand current | 65 kA 1 s 36 kA 3 s |
| [Icm] rated short-circuit making capacity | 143 kA 220/415 V AC at 50/60 Hz 143 kA 440 V AC at 50/60 Hz 143 kA 525 V AC at 50/60 Hz 143 kA 690 V AC at 50/60 Hz |
| Sensor rating | 800 A 1600 A |
| [Ui] rated insulation voltage | 1000 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 12 kV |
| Power dissipation in W | 390 W |
| Maximum breaking time | 25 ms |
| Maximum closing response time | 70 ms |
| Mounting support | Backplate Rails |
| Upside connection | Front Rear |
| Downside connection | Front Rear |
| Connection pitch | 115 mm |
| Mechanical durability | 12500 cycles without maintenance 25000 cycles with maintenance |
| Electrical durability | 10000 cycles 440 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-2 10000 cycles 690 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-2 AC-23A: 10000 cycles 440 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-3 AC-23A: 10000 cycles 690 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-3 |
| Height | 439 mm |
| Width | 441 mm |
| Depth | 395 mm |
| Product weight | 90 kg |
| Standards | EN/IEC 60947-1 EN/IEC 60947-2 |
| Product certifications | CE CCC EAC |





Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPacT |
| Range of product | ComPacT NS630b...1600 new generation |
| Device short name | Compact NS1600N |
| Product or component type | Basic frame |
| Device application | Distribution |
| Number of poles | 3P |
| [In] rated current | 1600 A at 50 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category B |
| [Icu] rated ultimate short-circuit breaking capacity | 50 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | N 50 kA 415 V AC |
| control type | Electrically operated |
| Mounting mode | Fixed |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ui] rated insulation voltage | 1000 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 37 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 (electrical operation) 37 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 (electrical operation) 37 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 (electrical operation) 30 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 (electrical operation) 22 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 (electrical operation) |
| [Icw] rated short-time withstand current | 19.2 kA 1 s conforming to IEC 60947-2 |
| Integral instant protection | 40 kA |
| Mechanical durability | 10000 cycles conforming to IEC 60947-2 |
| Electrical durability | 5000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2 1000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-2 2000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2 2000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-2 |
| Power losses | 74 W |
| Mounting support | Backplate |
| Connection pitch | 70 mm |
| Protection type | Without protection |
| Height (H) | 327 mm |
| Width (W) | 210 mm |
| Depth (D) | 147 mm |