Schneider
Schneider

Schneider

25001 products

Showing 1609 - 1632 of 25001 products

Showing 1609 - 1632 of 25001 products
View
A9L40501 Schneider Electric
Schneider A9L40501 Schneider Electric
Sale price0.00 kr
Sold Out

This Acti9 iPRD surge arrester protects 1P+N installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for high risk level in incoming panel board. It offers remote reporting of the "cartridge must be changed" message. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. It is compatible with TT and TN-S earthing system. The Uc maximum continuous operating voltage in common mode (between neutral and earth) is 260VAC. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Up Voltage protection level is 1.4kV in common mode (N/PE) and 1.6kV in differential mode (L/N) . The Ue rated operational voltage is 230VAC or 400VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 36mm x (H) 85mm x (D) 69mm. The weight is 220g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standard.

Main

Characteristic Value(s)
Range of product IPRD
range of product Acti9
product name Acti9 iPRD
Product or component type Surge arrester with pluggable cartridge
Device short name iPRD40r
Device application Distribution
Standards EN 61643-11:2012
IEC 61643-11:2011
Product certifications CE
Quality labels NF
KEMA-KEUR
Poles description 1P + N
Remote signalling With
Signal contacts composition 1 SD (1 C/O)
Surge arrester type Electrical distribution network
Earthing system TT
TN-S

Complementary

Characteristic Value(s)
Surge arrester class type Type 2
Surge arrester technology MOV + GDT
[Ue] rated operational voltage 230 V AC (+/- 10 %) at 50/60 Hz
Nominal discharge current Common mode: 15 kA (L/PE)
Common mode: 15 kA (N/PE)
Differential mode: 15 kA (L/N)
Maximum discharge current Common mode: 40 kA L/PE
Common mode: 40 kA N/PE
Differential mode: 40 kA L/N
[Uc] maximum continuous operating voltage Common mode: 260 V N/PE
Differential mode: 350 V L/N
Maximum [Up] voltage protection level Common mode <1.4 kV type 2 N/PE
Differential mode <1.6 kV type 2 L/N
[Ut] temporary overvoltage 337 V L/N 5 s withstand
1200 V N/PE 200 ms safe failure mode
442 V L/PE 5 s withstand
1455 V L/PE 200 ms safe failure mode
Disconnector device type Associated circuit breaker iC60H 40 A curve C - Icu 15 kA
Associated circuit breaker IC60N 40 A curve C - Icu 10 kA
Associated circuit breaker NG125H 40 A curve C - Icu 36 kA
Associated circuit breaker NG125L 40 A curve C - Icu 50 kA
Associated circuit breaker NG125N 40 A curve C - Icu 25 kA
Associated fuse gG 63 A - Icu 15 kA
Associated fuse gG 80 A - Icu 50 kA
Signalling circuit voltage 0.25 A/250 V AC 50/60 Hz
Mounting mode Clip-on (DIN rail)
9 mm pitches 4
Height 85 mm
Width 36 mm
Depth 69 mm
Product weight 220 g
Colour White (RAL 9003)
[Ipe] Ground residual current 0.003 mA
0.6 mA
Connections - terminals Tunnel type terminal (top or bottom) 4…16 mm² flexible
Tunnel type terminal (top or bottom) 4…16 mm² flexible with ferrule
Tunnel type terminal (top or bottom) 2.5…25 mm² rigid
Wire stripping length 14 mm
Tightening torque 3.5 N.m
Compatibility code IPRD40r
A9L40600 Schneider Electric
Schneider A9L40600 Schneider Electric
Sale price 4,687.00 kr
Only 1 unit left

This Acti9 iPRD40 surge arrester protects 3P+N installations. It allows quick replacement of damaged cartridges. Modular design (cartridge type) DIN rail mounted The associated circuit breaker Isc breaking capacity can go up to 50kA. This Acti9 iPRD40 is compatible with TT and TN-S earthing system. The Imax rated discharge current is 40kA. The In nominal discharge current is 15kA. The Uc maximum continuous operating voltage in common mode is 260VAC between neutral and earth, and 350VAC between phase and earth. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Up Voltage protection level is 1.4kV in common mode (N/PE) and in differential mode (L/N). The Un rated service voltage is 230VAC or 400VAC. The operating frequency is 50Hz or 60Hz. The dimensions are (W) 72mm x (H) 85mm x (D) 69mm. The width in 9mm pitches is 8. The weight is 450g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to +60°C. The storage temperature is -40°C to +85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standard.

Main

Characteristic Value(s)
Range of product IPRD
range of product Acti9
product name Acti9 iPRD
Product or component type Surge arrester with pluggable cartridge
Device short name iPRD40
Device application Distribution
Standards EN 61643-11:2012
IEC 61643-11:2011
Product certifications CE
Quality labels KEMA-KEUR
NF
Poles description 3P + N
Remote signalling Without
Surge arrester type Electrical distribution network
Earthing system TT
TN-S

Complementary

Characteristic Value(s)
Surge arrester class type Type 2
Surge arrester technology MOV + GDT
[Ue] rated operational voltage 230/400 V AC (+/- 10 %) at 50/60 Hz
Nominal discharge current Common mode: 15 kA (L/PE)
Common mode: 15 kA (N/PE)
Differential mode: 15 kA (L/N)
Maximum discharge current Common mode: 40 kA L/PE
Common mode: 40 kA N/PE
Differential mode: 40 kA L/N
[Uc] maximum continuous operating voltage Common mode: 260 V N/PE
Common mode: 350 V L/PE
Differential mode: 350 V L/N
Maximum [Up] voltage protection level Common mode <1.4 kV type 2 N/PE
Differential mode <1.4 kV type 2 L/N
[Ut] temporary overvoltage 337 V L/N 5 s withstand
1200 V N/PE 200 ms safe failure mode
442 V L/PE 5 s withstand
1453 V L/PE 200 ms safe failure mode
Disconnector device type Associated circuit breaker iC60H 40 A curve C - Icu 15 kA
Associated circuit breaker IC60N 40 A curve C - Icu 10 kA
Associated circuit breaker NG125H 40 A curve C - Icu 36 kA
Associated circuit breaker NG125L 40 A curve C - Icu 50 kA
Associated circuit breaker NG125N 40 A curve C - Icu 25 kA
Associated fuse gG 63 A - Icu 15 kA
Associated fuse gG 80 A - Icu 50 kA
Mounting mode Clip-on (DIN rail)
9 mm pitches 8
Height 85 mm
Width 72 mm
Depth 69 mm
Product weight 0.414 kg
Colour White (RAL 9003)
[Ipe] Ground residual current 0.003 mA
0.6 mA
Connections - terminals Tunnel type terminal (downside) 2.5…35 mm²
Tunnel type terminal (upside) 2.5…35 mm²
Tightening torque 2.5 N.m
Compatibility code IPRD40
A9L40601 Schneider Electric
Schneider A9L40601 Schneider Electric
Sale price0.00 kr
Sold Out

iPRD40r modular surge arrester - 3P + N - 350V - with remote transfert

Schneider Stock Image
Schneider A9L612501 Schneider
Sale price0.00 kr
Sold Out

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

A9L65101 Schneider Electric
Schneider A9L65101 Schneider Electric
Sale price0.00 kr
Sold Out

iPRD65r modular surge arrester - 1P - 350V - with remote transfert

A9L65102 Schneider Electric
Schneider A9L65102 Schneider Electric
Sale price0.00 kr
Sold Out

cartridge C65-350 for surge arrester iPRD

A9L65121 Schneider Electric
Schneider A9L65121 Schneider Electric
Sale price0.00 kr
Sold Out

iPRD65r modular surge arrester - 1P - IT - 460V - with remote transfert

A9L65201 Schneider Electric
Schneider A9L65201 Schneider Electric
Sale price0.00 kr
Sold Out

iPRD65r modular surge arrester - 2P - 350V - with remote transfert

A9L65301 Schneider Electric
Schneider A9L65301 Schneider Electric
Sale price0.00 kr
Sold Out

This Acti9 iPRD65r surge arrester protects 3P installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for very high risk level and incoming panel board. It offers remote reporting of the "cartridge must be changed" message. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. It is compatible with TT and TN-S earthing system. The Uc maximum continuous operating voltage in common mode is 260VAC between neutral and earth, and 350VAC between phase and earth. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Up Voltage protection level is 1.5kV in common mode (N/PE) and in differential mode (L/N). The Ue rated operational voltage is 230VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 72mm x (H) 85mm x (D) 69mm. The weight is 393g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11and IEC 61643-11 standards.

Main

Characteristic Value(s)
Range of product IPRD
range of product Acti9
product name Acti9 iPRD
Product or component type Surge arrester with pluggable cartridge
Device short name iPRD65r
Device application Distribution
Standards EN 61643-11:2012
IEC 61643-11:2011
Product certifications CE
Quality labels KEMA-KEUR
NF
Poles description 3P
Remote signalling With
Signal contacts composition 1 SD (1 C/O)
Surge arrester type Electrical distribution network
Earthing system TN-C
IT 230

Complementary

Characteristic Value(s)
Surge arrester class type Type 2
Surge arrester technology MOV + GDT
[Ue] rated operational voltage 400 V AC (+/- 10 %) at 50/60 Hz
Nominal discharge current Common mode: 20 kA (L/PE)
Common mode: 20 kA (N/PE)
Differential mode: 20 kA (L/N)
Maximum discharge current Common mode: 65 kA L/PE
Common mode: 65 kA N/PE
Differential mode: 65 kA L/N
[Uc] maximum continuous operating voltage Common mode: 260 V N/PE
Common mode: 350 V L/PE
Differential mode: 350 V L/N
Maximum [Up] voltage protection level Common mode <1.5 kV type 2 N/PE
Differential mode <1.5 kV type 2 L/N
[Ut] temporary overvoltage 337 V L/N 5 s withstand
1200 V N/PE 200 ms safe failure mode
Disconnector device type Associated circuit breaker IC60N 50 A curve C - Icu 10 kA
Associated circuit breaker iC60H 50 A curve C - Icu 15 kA
Associated circuit breaker NG125N 50 A curve C - Icu 25 kA
Associated circuit breaker NG125H 50 A curve C - Icu 36 kA
Associated circuit breaker NG125L 50 A curve C - Icu 50 kA
Associated fuse gG 80 A - Icu 50 kA
Signalling circuit voltage 0.25 A/250 V AC 50/60 Hz
Mounting mode Clip-on (DIN rail)
9 mm pitches 6
Height 85 mm
Width 54 mm
Depth 69 mm
Product weight 0.393 kg
Colour White (RAL 9003)
[Ipe] Ground residual current 0.6 mA
0.003 mA
Connections - terminals Tunnel type terminal (downside) 2.5…35 mm²
Tunnel type terminal (upside) 2.5…35 mm²
Tightening torque 2.5 N.m
Compatibility code IPRD65r
A9L65321 Schneider Electric
Schneider A9L65321 Schneider Electric
Sale price0.00 kr
Sold Out

This Acti9 iPRD65r surge arrester protects 3P installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for very high risk level and incoming panel board. It offers remote reporting of the "cartridge must be changed" message. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. It is compatible with TT and TN-S earthing system. The Uc maximum continuous operating voltage in common mode (between phase and earth) is 460VAC. The Up Voltage protection level in common mode (between phase and earth) is 2.3kV. The Ue rated operational voltage is 230VAC or 400VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 54mm x (H) 85mm x (D) 69mm. The weight is 340g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standards.

Main

Characteristic Value(s)
Range of product IPRD
range of product Acti9
product name Acti9 iPRD
Product or component type Surge arrester with pluggable cartridge
Device short name iPRD65r
Device application Distribution
Standards EN 61643-11:2012
IEC 61643-11:2011
Product certifications CE
Poles description 3P
Remote signalling With
Signal contacts composition 1 SD (1 C/O)
Surge arrester type Electrical distribution network
Earthing system IT

Complementary

Characteristic Value(s)
Surge arrester class type Type 2
Surge arrester technology MOV
[Ue] rated operational voltage 400 V AC (+/- 10 %) at 50/60 Hz
Nominal discharge current Common mode: 20 kA (L/PE)
Maximum discharge current Common mode: 65 kA L/PE
[Uc] maximum continuous operating voltage Common mode: 460 V L/PE
Maximum [Up] voltage protection level Common mode <2.3 kV type 2 L/PE
[Ut] temporary overvoltage 337 V L/N 5 s withstand
1455 V L/PE 200 ms safe failure mode
1455 V N/PE 200 ms safe failure mode
Short-circuit withstand 5 kA 415 V Ph/Ph
Disconnector device type Associated circuit breaker iC60L 25 A curve C - Icu 25 kA
Associated circuit breaker NG125H 50 A curve C - Icu 36 kA
Associated circuit breaker NG125L 50 A curve C - Icu 50 kA
Associated fuse gG 80 A - Icu 50 kA
Signalling circuit voltage 0.25 A/250 V AC 50/60 Hz
Mounting mode Clip-on (DIN rail)
9 mm pitches 6
Height 85 mm
Width 54 mm
Depth 69 mm
Product weight 340 g
Colour White (RAL 9003)
[Ipe] Ground residual current 0.6 mA
Connections - terminals Tunnel type terminal (top or bottom) 2.5…25 mm² rigid
Tunnel type terminal (top or bottom) 4…16 mm² flexible
Tunnel type terminal (top or bottom) 4…16 mm² flexible with ferrule
Wire stripping length 14 mm
Tightening torque 3.5 N.m
Targeted country All
Compatibility code IPRD65r
A9L65401 Schneider Electric
Schneider A9L65401 Schneider Electric
Sale price0.00 kr
Sold Out

iPRD65r modular surge arrester - 4P - 350V - with remote transfert

A9L65501 Schneider Electric
Schneider A9L65501 Schneider Electric
Sale price0.00 kr
Sold Out

iPRD65r modular surge arrester - 1P + N - 350V - with remote transfert

A9L65601 Schneider Electric
Schneider A9L65601 Schneider Electric
Sale price 7,005.00 kr
Only 1 unit left

iPRD65r modular surge arrester - 3P + N - 350V - with remote transfert

A9MEM1520 Schneider Electric
Schneider A9MEM1520 Schneider Electric
Sale price0.00 kr
Sold Out

This PowerTag A9 M63 1PW for Acti 9 and Multi 9 Monoconnect offers is a Class 1 wireless-communication energy sensor. It is dedicated to Acti9 and Multi9 1P Monoconnect devices rating less than or equal 63A. The neutral blue wire is to be connected to a neutral terminal block. It has to be associated with a concentror or a gateway to provide circuit monitoring and diagnosis down to load level. It is designed specifically for Energy Management, Load Monitoring and Power Availability applications. It incorporates accurate real-time measurements of active energy, active power, current, voltage and power factor. In case of power outage, it sends a voltage loss alarm and the current-per-phase value before being de-energized. PowerTag Energy 63A complies with IEC 61557-12 standard. It is a PMD-I/DD/K55/1. The Performance category is Class 1. The Imax Maximum current is 63A. The Ib Base current is 10A. The Saturation current is 130A. The Ist Starting current is 40mA. The Un rated voltage is Phase-to-neutral 200VAC to 240VAC +/- 20%. The maximum consumption is below or equal to 1VA. The degree of protection is IP20 and IK05 The Operating temperature is between -25°C to +60°C. The Storage temperature is between 40°C to +85°C. The Performance category is Class 1. PowerTag Energy 63A complies with IEC 61557-12 standard.

Main

Characteristic Value(s)
Range of product PowerLogic
product name PowerTag A9 M63
Product or component type Energy sensor
Poles 1P
Maximum current [Imax] 63 A
[Ib] Basic current 10 A
Starting current 40 mA
Saturation current 130 A
Product specific application Load monitoring
Overload alarm
Cost allocation
Circuit monitoring
Energy management
Concentrator compatibility Acti9 Smartlink SI B
Acti9 Smartlink SI D
Acti9 PowerTag Link C
Acti9 PowerTag Link
Acti9 PowerTag Link HD
Wiser IP module
EcoStruxure Panel Server Universal
EcoStruxure Panel Server Advanced
PrismaSet Active
Application Buildings: breaker voltage monitoring
Buildings: cost allocation
Buildings: overload alarm
Range compatibility Acti 9 Acti9 iKQE RCBO
Multi9 Multi9 C60
Multi9 Multi9 ID
Multi9 Multi9 C32N
Multi9 Multi9 C65
Acti 9 Acti9 iID
Acti 9 Acti9 iID K
Acti 9 Acti9 iK60
Acti 9 Acti9 iKQ
Acti 9 Acti9 K60
Acti 9 Acti9 Reflex iC60
Acti 9 Acti9 iC65
Acti 9 Acti9 DT60
Acti 9 Acti9 iC60 single terminal
Type of measurement Voltage
Power factor
Active energy
Current
Active power
Accuracy class Class 1 current conforming to IEC 61557-12
Class 0.5 voltage conforming to IEC 61557-12
Class 1 active power conforming to IEC 61557-12
Class 1 active energy conforming to IEC 61557-12
Class 1 power factor conforming to IEC 61557-12
Mounting location Top or bottom
Mounting support On circuit breaker
Product destination Switchboard
Event management Voltage loss with measured current at voltage loss
Transmission support medium Radio frequency 2.4…2.4835 GHz conforming to IEEE 802.15.4
Emission power 10 mW

Complementary

Characteristic Value(s)
Form factor Monoconnect
Mounting mode By screws (terminals)
Electrical connection (voltage sensing & power supply) Connector tooth and wire
Cable cross section 1 rigid cable 1.5…16 mm²
2 stranded cable 1.5…2.5 mm²
2 rigid cable 1.5…2.5 mm²
1 stranded cable 1.5…16 mm²
Cable length 1 m
supply voltage 200...240 V AC, +/- 20 %
Cable composition 1 x 0.33 mm²
Network frequency 50 Hz
60 Hz
Maximum power consumption 1 VA
Standards IEC 61557-12
IEC 61010-1
IEC 61010-2-030
IEC 61326-1
ETSI EN 300 328
ETSI EN 301 489-1
Height 16.5 mm
Width 18 mm
Depth 43 mm
Product weight 16.4 g
Colour White (RAL 9003)
Compatibility code PowerTag A9 M63
A9MEM1521 Schneider Electric
Schneider A9MEM1521 Schneider Electric
Sale price0.00 kr
Sold Out

energy sensor, PowerTag Monoconnect 63A 1P+N top position

A9MEM1522 Schneider Electric
Schneider A9MEM1522 Schneider Electric
Sale price0.00 kr
Sold Out

energy sensor, PowerTag Monoconnect 63A 1P+N bottom position

A9MEM1540 Schneider Electric
Schneider A9MEM1540 Schneider Electric
Sale price0.00 kr
Sold Out

energy sensor, PowerTag Monoconnect 63A 3P top and bottom position

A9MEM1541 Schneider Electric
Schneider A9MEM1541 Schneider Electric
Sale price0.00 kr
Sold Out

This PowerTag A9 M63 3PN T for Acti 9 and Multi 9 Monoconnect offers is a Class 1 wireless-communication energy sensor. It is dedicated to Acti9 and Multi9 3P+N Monoconnect devices with 18mm pitch between phase and neutral, rating less than or equal 63A. It has to be associated with a concentror or a gateway to provide circuit monitoring and diagnosis down to load level. It is designed specifically for Energy Management, Load Monitoring and Power Availability applications. It incorporates accurate real-time measurements of active energy, active power, current, voltage and power factor. In case of power outage, it sends a voltage loss alarm and the current-per-phase value before being de-energized. PowerTag Energy 63A complies with IEC 61557-12 standard. It is a PMD-I/DD/K55/1. The Performance category is Class 1. The Imax Maximum current is 63A. The Ib Base current is 10A. The Saturation current is 130A. The Ist Starting current is 40mA. The Un rated voltage are Phase-to-neutral 220VAC to 240VAC +/- 20% and Phase-to-phase 380VAC to 415VAC +/- 20%. The maximum consumption is below or equal to 2VA. The degree of protection is IP20 and IK05. The Operating temperature is between -25°C to +60°C. The Storage temperature is between 40°C to +85°C. The Performance category is Class 1. PowerTag Energy 63A complies with IEC 61557-12 standard.

Main

Characteristic Value(s)
Range of product PowerLogic
product name PowerTag A9 M63
Product or component type Energy sensor
Poles 3P + N
Maximum current [Imax] 63 A
[Ib] Basic current 10 A
Starting current 40 mA
Saturation current 130 A
Product specific application Cost allocation
Load monitoring
Circuit monitoring
Overload alarm
Energy management
Concentrator compatibility Acti9 Smartlink SI B
Acti9 Smartlink SI D
Acti9 PowerTag Link C
Acti9 PowerTag Link
Acti9 PowerTag Link HD
Wiser IP module
EcoStruxure Panel Server Universal
EcoStruxure Panel Server Advanced
PrismaSet Active
Application Buildings: breaker voltage monitoring
Buildings: cost allocation
Buildings: overload alarm
Range compatibility Acti 9 Acti9 iKQE RCBO
Multi9 Multi9 C60
Multi9 Multi9 ID
Multi9 Multi9 C32N
Multi9 Multi9 C65
Acti 9 Acti9 iID
Acti 9 Acti9 iID K
Acti 9 Acti9 iK60
Acti 9 Acti9 iKQ
Acti 9 Acti9 K60
Acti 9 Acti9 Reflex iC60
Acti 9 Acti9 iC65
Acti 9 Acti9 DT60
Acti 9 Acti9 iC60 single terminal
Type of measurement Voltage
Active energy
Current
Active power
Power factor
Accuracy class Class 1 current conforming to IEC 61557-12
Class 0.5 voltage conforming to IEC 61557-12
Class 1 active power conforming to IEC 61557-12
Class 1 active energy conforming to IEC 61557-12
Class 1 power factor conforming to IEC 61557-12
Mounting location Top
Mounting support On circuit breaker
Product destination Switchboard
Event management Voltage loss with measured current at voltage loss
Transmission support medium Radio frequency 2.4…2.4835 GHz conforming to IEEE 802.15.4
Emission power 10 mW

Complementary

Characteristic Value(s)
Form factor Monoconnect
Mounting mode By screws (terminals)
Electrical connection (voltage sensing & power supply) Connector tooth
Cable cross section 1 rigid cable 1.5…16 mm²
2 stranded cable 1.5…2.5 mm²
2 rigid cable 1.5…2.5 mm²
1 stranded cable 1.5…16 mm²
supply voltage 220...240 V AC, +/- 20 %, between phase and neutral
380...415 V AC, +/- 20 %, between phases
Network frequency 50 Hz
60 Hz
Maximum power consumption 2 VA
Standards IEC 61557-12
IEC 61010-1
IEC 61010-2-030
IEC 61326-1
ETSI EN 300 328
ETSI EN 301 489-1
Height 16.5 mm
Width 72 mm
Depth 43 mm
Product weight 35 g
Colour White (RAL 9003)
Compatibility code PowerTag A9 M63
A9MEM1542 Schneider Electric
Schneider A9MEM1542 Schneider Electric
Sale price0.00 kr
Sold Out

energy sensor, PowerTag Monoconnect 63A 3P+N bottom position

A9MEM1560 Schneider Electric
Schneider A9MEM1560 Schneider Electric
Sale price 4,144.00 kr
Only 1 unit left

energy sensor, PowerTag Flex 230V, 63A 1P+N top and bottom position

A9MEM1561 Schneider Electric
Schneider A9MEM1561 Schneider Electric
Sale price0.00 kr
Sold Out

energy sensor, PowerTag phaseNeutral 63A 1P+N top position

A9MEM1562 Schneider Electric
Schneider A9MEM1562 Schneider Electric
Sale price0.00 kr
Sold Out

energy sensor, PowerTag phaseNeutral 63A 1P+N bottom position

A9MEM1570 Schneider Electric
Schneider A9MEM1570 Schneider Electric
Sale price 3,978.00 kr
Only 1 unit left

This PowerTag Energy F63 1P+N 110V is a wireless communication energy sensor. With its Flex design, it is dedicated to 3P+N devices, rating less than or equal 63A. It has to be associated with a concentror or a gateway to provide circuit monitoring and diagnosis down to load level. It is designed specifically for Energy Management, Load Monitoring and Power Availability applications. It incorporates accurate real-time measurements of active energy, active power, current, voltage and power factor. In case of power outage, it sends a voltage loss alarm and the current-per-phase value before being de-energized. PowerTag Energy 63A complies with IEC 61557-12 standard. It is a PMD-I/DD/K55/1. The Performance category is Class 1. The Imax Maximum current is 63A. The Ib Base current is 10A. The Saturation current is 130A. The Ist Starting current is 40mA. The Un rated voltage are Phase-to-neutral 220VAC to 240VAC +/- 20% and Phase-to-phase 380VAC to 415VAC +/- 20%. The maximum consumption is below or equal to 2VA. It can be either mounted on the top or the bottom of the protective device. The product color is white (RAL9003). The weight is 40g. The degree of protection is IP20 and IK05 The operating temperature is between -25°C to +60°C. The Storage temperature is between -40°C to +85°C.

Main

Characteristic Value(s)
Range of product PowerLogic
product name PowerTag A9 F63
Product or component type Energy sensor
Poles 3P + N
Maximum current [Imax] 63 A
[Ib] Basic current 10 A
Starting current 40 mA
Saturation current 130 A
Product specific application Cost allocation
Load monitoring
Overload alarm
Circuit monitoring
Energy management
Concentrator compatibility Acti9 Smartlink SI B
Acti9 Smartlink SI D
Acti9 PowerTag Link C
Acti9 PowerTag Link
Acti9 PowerTag Link HD
Harmony Hub
Wiser IP module
EcoStruxure Panel Server Universal
EcoStruxure Panel Server Advanced
PrismaSet Active
Application Buildings: breaker voltage monitoring
Buildings: cost allocation
Buildings: overload alarm
Range compatibility Acti 9 Vigi DT40
Acti 9 Vigi iC40
Acti 9 Vigi iDT40
Acti 9 Vigi N40
Acti 9 Vigi C40
Acti 9 Vigi iC60
Acti 9 Acti9 iDD40
Acti 9 Acti9 iDD40 XA
Acti 9 Acti9 iCV40 XA
Acti 9 Vigi iDPN
Acti 9 Acti9 iCV40
Acti 9 Vigi iTG40
Acti 9 Vigi iCG40
Type of measurement Voltage
Active energy
Active power
Current
Power factor
Accuracy class Class 1 current conforming to IEC 61557-12
Class 0.5 voltage conforming to IEC 61557-12
Class 1 active power conforming to IEC 61557-12
Class 1 active energy conforming to IEC 61557-12
Class 1 power factor conforming to IEC 61557-12
Mounting location Top or bottom
Mounting support On circuit breaker
Product destination Switchboard
Event management Voltage loss with measured current at voltage loss
Transmission support medium Radio frequency 2.4…2.4835 GHz conforming to IEEE 802.15.4
Emission power 10 mW

Complementary

Characteristic Value(s)
Form factor Flex
Mounting mode By screws (terminals)
Electrical connection (voltage sensing & power supply) Wires with cable end
Cable cross section 1 rigid cable 1.5…16 mm²
2 stranded cable 1.5…2.5 mm²
2 rigid cable 1.5…2.5 mm²
1 stranded cable 1.5…16 mm²
Cable length 0.25 m
supply voltage 220...240 V AC, +/- 20 %, between phase and neutral
380...415 V AC, +/- 20 %, between phases
Network frequency 50 Hz
60 Hz
Maximum power consumption 2 VA
Standards IEC 61557-12
IEC 61010-1
IEC 61010-2-030
IEC 61326-1
ETSI EN 300 328
ETSI EN 301 489-1
Height Sensor element: 20 mm
Width Sensor element: 54 mm
Depth Sensor element: 46.6 mm
Product weight 40 g
Colour White (RAL 9003)
Compatibility code PowerTag A9 P63
A9MEM1571 Schneider Electric
Schneider A9MEM1571 Schneider Electric
Sale price0.00 kr
Sold Out

This PowerTag Energy P63 3P+N Top is a wireless communication energy sensor. It is dedicated to Acti9 and Multi9 3P+N PhaseNeutral devices with 9mm pitch between phase and neutral, rating less than or equal 63A. It has to be associated with a concentror or a gateway to provide circuit monitoring and diagnosis down to load level. It is designed specifically for Energy Management, Load Monitoring and Power Availability applications. It incorporates accurate real-time measurements of active energy, active power, current, voltage and power factor. In case of power outage, it sends a voltage loss alarm and the current-per-phase value before being de-energized. PowerTag Energy 63A complies with IEC 61557-12 standard. It is a PMD-I/DD/K55/1. The Performance category is Class 1. The Imax Maximum current is 63A. The Ib Base current is 10A. The Saturation current is 130A. The Ist Starting current is 40mA. The Un rated voltage are Phase-to-neutral 220VAC to 240VAC +/- 20% and Phase-to-phase 380VAC to 415VAC +/- 20%. The maximum consumption is below or equal to 2VA. It can be only mounted on the top of the protective device. The product color is white (RAL9003). The weight is 48g. The degree of protection is IP20 and IK05 The operating temperature is between -25°C to +60°C. The Storage temperature is between -40°C to +85°C.

Main

Characteristic Value(s)
Range of product PowerLogic
product name PowerTag A9 P63
Product or component type Energy sensor
Poles 3P + N
Maximum current [Imax] 63 A
[Ib] Basic current 10 A
Starting current 40 mA
Saturation current 130 A
Product specific application Load monitoring
Overload alarm
Circuit monitoring
Cost allocation
Energy management
Concentrator compatibility Acti9 Smartlink SI B
Acti9 Smartlink SI D
Acti9 PowerTag Link C
Acti9 PowerTag Link
Acti9 PowerTag Link HD
Wiser IP module
EcoStruxure Panel Server Universal
EcoStruxure Panel Server Advanced
PrismaSet Active
Application Buildings: breaker voltage monitoring
Buildings: cost allocation
Buildings: overload alarm
Range compatibility Multi9 Multi9 N40 Vigi
Acti 9 Acti9 C40 Vigi
Acti 9 Acti9 iDPN
Acti 9 Acti9 iC40
Multi9 Multi9 N40
Acti 9 Acti9 iCV40
Acti 9 Acti9 C40
Acti 9 Acti9 DT40
Acti 9 Acti9 DT40 Vigi
Acti 9 Acti9 iDPN Vigi
Type of measurement Active power
Power factor
Active energy
Voltage
Current
Accuracy class Class 1 current conforming to IEC 61557-12
Class 0.5 voltage conforming to IEC 61557-12
Class 1 active power conforming to IEC 61557-12
Class 1 active energy conforming to IEC 61557-12
Class 1 power factor conforming to IEC 61557-12
Mounting location Top
Mounting support On circuit breaker
Connection pitch 9 mm Ph/N
18 mm Ph/Ph
Product destination Switchboard
Event management Voltage loss with measured current at voltage loss
Transmission support medium Radio frequency 2.4…2.4835 GHz conforming to IEEE 802.15.4
Emission power 10 mW

Complementary

Characteristic Value(s)
Form factor PhaseNeutral
Mounting mode By screws (terminals)
Electrical connection (voltage sensing & power supply) Connector tooth
Cable cross section 1 rigid cable 1.5…16 mm²
2 stranded cable 1.5…2.5 mm²
2 rigid cable 1.5…2.5 mm²
1 stranded cable 1.5…16 mm²
supply voltage 220...240 V AC, +/- 20 %, between phase and neutral
380...415 V AC, +/- 20 %, between phases
Network frequency 50 Hz
60 Hz
Maximum power consumption 2 VA
Standards IEC 61557-12
IEC 61010-1
IEC 61010-2-030
IEC 61326-1
ETSI EN 300 328
ETSI EN 301 489-1
Height Sensor element: 19.5 mm
Base unit: 8 mm
Width Sensor element: 54 mm
Base unit: 54 mm
Depth Sensor element: 43 mm
Base unit: 48 mm
Product weight 48 g
Colour White (RAL 9003)
Compatibility code PowerTag A9 P63

Recently viewed