This Acti9 iRCI product is a current control relay. It has a changeover contact (C/O). The Ie rated operational voltage is 8A with a Ue rated operational voltage of 250VAC, with the condition of test that the power factor (cos phi) is worth 1.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| product name | Acti9 iRC |
| Product or component type | Control relay |
| Device short name | iRCI |
| Device application | Current control relay |
| Signal contacts composition | 1 C/O |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ie] rated operational current | 8 A at 250 V AC (cos Phi = 1) |
| Local signalling | Reports when the preset threshold is reached Red LED for fault Green LED for power on |
| Type of setting | Selected by wiring: measurement range Switch: overcurrent Switch: undercurrent |
| Tripping threshold | 10...100 % |
| Analogue input range | 1...10 A DC 0.15...1.5 A DC 1...10 A AC 0.15...1.5 A AC |
| Hysteresis | 5â¦50 % |
| Time delay range | 0.1...10 s |
| Accuracy error | +/- 10 % |
| [Us] rated supply voltage | 230 V AC at 50/60 Hz |
| Power consumption in VA | 3 VA |
| Power dissipation in W | 2 W |
| Mounting mode | Fixed |
| Mounting support | 35 mm symmetrical DIN rail |
| 9 mm pitches | 4 |
| Height | 88.1 mm |
| Width | 36 mm |
| Depth | 67 mm |
| Product weight | 215 g |
| Colour | White |
| Connections - terminals | Tunnel type terminals6 cable(s) 1.5 mm² rigid |

This Acti9 iRCU product is a voltage control relay. It has a changeover contact (C/O).
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| product name | Acti9 iRC |
| Product or component type | Control relay |
| Device short name | iRCU |
| Device application | Voltage control relay |
| Signal contacts composition | 1 C/O |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ie] rated operational current | 8 A at 250 V AC 50/60 Hz (cos Phi = 1) |
| Local signalling | Reports when the preset threshold is reached Red LED for fault Green LED for power on |
| Type of setting | Selected by wiring: measurement range Switch: overvoltage Switch: undervoltage |
| Tripping threshold | 10...100 % |
| Analogue input range | 50...500 V AC 10...100 V DC 50...500 V DC 10...100 V AC |
| Hysteresis | 5â¦50 % |
| Time delay range | 0.1...10 s |
| Accuracy error | +/- 10 % |
| [Us] rated supply voltage | 230 V AC at 50/60 Hz |
| Power consumption in VA | 3 VA |
| Mounting mode | Fixed |
| Mounting support | 35 mm symmetrical DIN rail |
| 9 mm pitches | 4 |
| Height | 88.1 mm |
| Width | 36 mm |
| Depth | 67 mm |
| Product weight | 0.215 kg |
| Colour | White |
| Connections - terminals | Tunnel type terminals6 cable(s) 1.5 mm² rigid |

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Miniature circuit-breaker, Acti9 iC60N, 3P, 50 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.










Miniature circuit-breaker, Acti9 iC60H, 2P, 6 A, D curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)

Miniature circuit-breaker, Acti9 iC60H, 2P, 10 A, D curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)