Safety

7727 products

Showing 7681 - 7704 of 7727 products

Showing 7681 - 7704 of 7727 products
View
Leuze Stock Image
Leuze MLC520T14-300G Leuze
Sale price 28,952.00 kr
Only 3 units left
Leuze MLC 500 Series Safety Light Curtain Transmitter (P/N: MLC520T14-300G). Type 4 / SIL 3 safety light curtain for machine guarding and access protection. 14mm resolution, Provides reliable personnel and finger protection per IEC 61496 with integrated muting, blanking, and cascading functions. 24VDC operation with OSSD safety outputs.
Leuze Stock Image
Leuze MLC501T30-450 Leuze
Sale price 7,916.00 kr
Only 6 units left
Leuze MLC 300 Series Safety Light Curtain Module (P/N: MLC501T30-450). Type 4 / SIL 3 safety light curtain for machine guarding and access protection. 30mm resolution, Provides reliable personnel and finger protection per IEC 61496 with integrated muting, blanking, and cascading functions. 24VDC operation with OSSD safety outputs.
Leuze Stock Image
Leuze MLC300T90-1050 Leuze
Sale price0.00 kr
Sold Out
Leuze MLC 300 Series Safety Light Curtain Module (P/N: MLC300T90-1050). Type 4 / SIL 3 safety light curtain for machine guarding and access protection. 90mm resolution, Provides reliable personnel and finger protection per IEC 61496 with integrated muting, blanking, and cascading functions. 24VDC operation with OSSD safety outputs.
Leuze Stock Image
Leuze MLC500T14-600G Leuze
Sale price0.00 kr
Sold Out
Leuze MLC 500 Series Safety Light Curtain Transmitter (P/N: MLC500T14-600G). Type 4 / SIL 3 safety light curtain for machine guarding and access protection. 14mm resolution, Provides reliable personnel and finger protection per IEC 61496 with integrated muting, blanking, and cascading functions. 24VDC operation with OSSD safety outputs.
Leuze Stock Image
Leuze MLC500T20-1650H Leuze
Sale price0.00 kr
Sold Out
Leuze MLC 500 Series Safety Light Curtain Transmitter (P/N: MLC500T20-1650H). Type 4 / SIL 3 safety light curtain for machine guarding and access protection. 20mm resolution, Provides reliable personnel and finger protection per IEC 61496 with integrated muting, blanking, and cascading functions. 24VDC operation with OSSD safety outputs.
Leuze Stock Image
Leuze MLC500T30-1650H Leuze
Sale price0.00 kr
Sold Out
Leuze MLC 500 Series Safety Light Curtain Transmitter (P/N: MLC500T30-1650H). Type 4 / SIL 3 safety light curtain for machine guarding and access protection. 30mm resolution, Provides reliable personnel and finger protection per IEC 61496 with integrated muting, blanking, and cascading functions. 24VDC operation with OSSD safety outputs.
Leuze Stock Image
Leuze CML720I-T10-1100A-M12-EX Leuze
Sale price0.00 kr
Sold Out
Leuze CML720i Measuring Light Curtain Transmitter (P/N: CML720I-T10-1100.A-M12-EX). High-resolution measurement light curtain for object detection, dimensioning, counting, and profiling. Provides precise non-contact measurement with IO-Link communication, configurable resolution, and M12 connectivity for packaging, logistics, and factory automation.
Leuze Stock Image
Leuze MLC500T20-450MG Leuze
Sale price0.00 kr
Sold Out
Leuze MLC 500 Series Safety Light Curtain Transmitter (P/N: MLC500T20-450MG). Type 4 / SIL 3 safety light curtain for machine guarding and access protection. 20mm resolution, Provides reliable personnel and finger protection per IEC 61496 with integrated muting, blanking, and cascading functions. 24VDC operation with OSSD safety outputs.
Leuze Stock Image
Leuze MLC520R20-1500-EX2 Leuze
Sale price 29,269.00 kr
Only 4 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence SL-R11G Keyence
Sale price 5,928.00 kr
Only 4 units left
Buy the Keyence SL-R11G - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence SL-R11G is a direct drop-in replacement for existing installations and ships ready for integration.
Keyence Stock Image
Keyence SR-PN1 Keyence
Sale price 9,216.00 kr
Only 7 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence SL-C32H-T Keyence
Sale price 21,123.00 kr
Only 8 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence SL-JB79 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SL-JB79

Type

Protect Bar

Applicable product

SL-V79F, SL-V40H(S), SL-V20L

keyence Stock Image
Keyence SL-V72HM Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SL-V72HM

Detection capability

ø0.98" ø25 mm

Beam axis spacing/Lens diameter

20 mm/ø5 mm 0.79"/ø0.20"

Effective aperture angle

Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 to 7 m

Response time (ms)

ON→OFF

15.8*1

OFF→ON

55.8*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 µA*3

Max. capacitive load

2.2 µF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

137*6

Receiver

96*6

When the center indicator is OFF

Transmitter

126*6

Receiver

78*6

Environmental resistance

Enclosure rating

IP65/67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

2,850 g

Receiver

2,880 g

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6 ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55 °C 113 to 131 °F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55 °C 113 to 131 °F, use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by 10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of both transmitter and receiver is fixed.)
In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the OFF state.
In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON state.

Keyence Stock Image
Keyence SL-V23F Keyence
Sale price 11,821.00 kr
Only 9 units left

Specifications

Model

SL-V23F

Detection capability

ø0.55" ø14 mm

Beam axis spacing/Lens diameter

10 mm/ø4 mm 0.39"/ø0.16"

Effective aperture angle

Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 to 7 m

Response time (ms)

ON→OFF

9.1*1

OFF→ON

49.1*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 µA*3

Max. capacitive load

2.2 µF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMI

EN61000-6-2, EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

83*6

Receiver

78*6

When the center indicator is OFF

Transmitter

80*6

Receiver

74*6

Environmental resistance

Enclosure rating

IP65 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

200 g

Receiver

205 g

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6 ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55 °C 113 to 131 °F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55 °C 113 to 131 °F, use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by 10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of both transmitter and receiver is fixed.)
In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the OFF state.
In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON state.

Keyence Stock Image
Keyence SL-V08H Keyence
Sale price 5,958.00 kr
Only 5 units left

Specifications

Model

SL-V08H

Detection capability

ø0.98" ø25 mm

Beam axis spacing/Lens diameter

20 mm/ø5 mm 0.79"/ø0.20"

Effective aperture angle

Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 to 9 m

Response time (ms)

ON→OFF

7*1

OFF→ON

47*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 µA*3

Max. capacitive load

2.2 µF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

56*6

Receiver

70*6

When the center indicator is OFF

Transmitter

52*6

Receiver

65*6

Environmental resistance

Enclosure rating

IP65 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

150 g

Receiver

155 g

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6 ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55 °C 113 to 131 °F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55 °C 113 to 131 °F, use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by 10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of both transmitter and receiver is fixed.)
In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the OFF state.
In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON state.

Keyence Stock Image
Keyence SL-V103F-R Keyence
Sale price 20,894.00 kr
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence SL-C24H Keyence
Sale price 17,223.00 kr
Only 8 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence SL-M16H Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SL-M16H

Detecting distance when using the SL-C Series

When using SL-CH

With 1 mirror: 8.1 m, with 2 mirrors: 7.2 m, with 3 mirrors: 6.5 m, with 4 mirrors: 5.9 m

When using SL-CL

When using SL-CF

With 1 mirror: 6.3 m, with 2 mirrors: 5.6 m, with 3 mirrors: 5.1 m, with 4 mirrors: 4.6 m

Reflective surface length

358 mm 14.09"

Supported: SL-C Series

SL-C Series units that have a total length shorter than that of the reflective surface

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 95 % RH (No condensation)

Material

Main unit case

Aluminum

Mirror

Back-side mirror

Mounting bracket

SUS304

Accessories

Mounting bracket (2-piece set)

Weight

Approx. 1.6 kg (including mounting bracket)

Keyence Stock Image
Keyence SL-C20L Keyence
Sale price 6,500.00 kr
Only 3 units left
Buy the Keyence SL-C20L Safety Device - an industrial safety component providing personnel protection and machine safeguarding per international safety standards. Features SIL-rated operation, reliable monitoring, and standard safety system integration. The Keyence SL-C20L is a direct replacement for existing installations.
keyence Stock Image
Keyence SL-V111FM Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SL-V111FM

Detection capability

ø0.55" ø14 mm

Beam axis spacing/Lens diameter

10 mm/ø4 mm 0.39"/ø0.16"

Effective aperture angle

Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 to 7 m

Response time (ms)

ON→OFF

21.2*1

OFF→ON

61.2*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 µA*3

Max. capacitive load

2.2 µF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

163*6

Receiver

104*6

When the center indicator is OFF

Transmitter

152*6

Receiver

92*6

Environmental resistance

Enclosure rating

IP65/67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

2,330 g

Receiver

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6 ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55 °C 113 to 131 °F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55 °C 113 to 131 °F, use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by 10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of both transmitter and receiver is fixed.)
In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the OFF state.
In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON state.

keyence Stock Image
Keyence SL-V64H Keyence
Sale price 21,128.00 kr
Only 5 units left

Specifications

Model

SL-V64H

Detection capability

ø0.98" ø25 mm

Beam axis spacing/Lens diameter

20 mm/ø5 mm 0.79"/ø0.20"

Effective aperture angle

Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 to 9 m

Response time (ms)

ON→OFF

14.7*1

OFF→ON

54.7*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 µA*3

Max. capacitive load

2.2 µF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

130*6

Receiver

93*6

When the center indicator is OFF

Transmitter

120*6

Receiver

77*6

Environmental resistance

Enclosure rating

IP65 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

860 g

Receiver

885 g

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6 ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55 °C 113 to 131 °F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55 °C 113 to 131 °F, use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by 10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of both transmitter and receiver is fixed.)
In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the OFF state.
In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON state.

keyence Stock Image
Keyence SL-VS01 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SL-VS01

Type

Serial Connection Cable

Applicable product

SL-V Series

Length

0.15 m 0.49'

Note

· Up to 3 units can be connected in series. · The total number of optical axes is 240 (230 only when 3 SL-VHS units are connected).

Keyence New Stock Image
Keyence SL-V36HM-R Keyence
Sale price 33,809.00 kr
Only 6 units left

Specifications

Model

SL-V36HM

Detection capability

ø0.98" ø25 mm

Beam axis spacing/Lens diameter

20 mm/ø5 mm 0.79"/ø0.20"

Effective aperture angle

Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)

Working distance

0.1 to 9 m

Response time (ms)

ON→OFF

10.9*1

OFF→ON

50.9*1

Light source

Infrared LED (850 nm)

Operation mode

Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

OSSD output

Output

2 outputs each for PNP and NPN. Can be changed by using the connector cable.

Max. l oad current

500 mA*2

Residual vol tage (during ON)

Max. 2.5 V (with a cable length of 7 m 22.97')

Leakage current

Max. 100 µA*3

Max. capacitive load

2.2 µF (with a load resistance of 100 Ω)

Load wiring resistance

Max. 2.5 Ω*4

Non safety-rel ated output

AUX

Output with automatic PNP/NPN switching function, 50 mA max.

Interlock-reset-ready output

Alarm output

Clear/blocked output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998

Rating

Power voltage

24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

Current consumption (mA)

When the center indicator is ON

Transmitter

98*6

Receiver

82*6

When the center indicator is OFF

Transmitter

91*6

Receiver

71*6

Environmental resistance

Enclosure rating

IP65/67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Weight

Transmitter

1,540 g

Receiver

1,560 g

*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.
e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and SL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6 ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
*2 When used under ambient temperature between 45 to 55 °C 113 to 131 °F , the maximum should not exceed 300 mA.
*3 Applies to situations when power is either off or disconnected.
*4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
*5 When used under ambient temperature between 45 to 55 °C 113 to 131 °F, use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
*6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by 10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of both transmitter and receiver is fixed.)
In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the OFF state.
In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON state.