Overload Relays

930 products

Showing 337 - 360 of 930 products

Showing 337 - 360 of 930 products
View
Schneider New Stock Image
Schneider LRN22N16-24A Schneider
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV2P01 Schneider Electric
Schneider GV2P01 Schneider Electric
Sale price0.00 kr
Sold Out

Motor circuit breaker, TeSys GV2, 3P, 0.1-0.16 A, thermal magnetic, screw clamp terminals

Schneider New Stock Image
Schneider LRD-16C Schneider
Sale price 877.00 kr
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider GVAN11NONC Schneider
Sale price 862.00 kr
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV4LE50B6 Schneider Electric
Schneider GV4LE50B6 Schneider Electric
Sale price0.00 kr
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. It provides magnetic protection, breaking capacity Icu 25kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Magnetic protection adjustable by dial, setting range 6-14 In. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). To be used in association with a class 10 or 20 thermal overload relay to complete motor protection. Multi standards certified (IEC, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Main

Characteristic Value(s)
Range of product TeSys GV4
Range TeSys Deca
Device short name GV4L
product name TeSys GV4
Product or component type Motor circuit breaker
Device application Motor protection
Trip unit technology Magnetic
Electronic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Operating position Any position
Motor power kW 11 kW at 400...415 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
18.5 kW at 660...690 V AC 50/60 Hz
15 kW at 400...415 V AC 50/60 Hz
18.5 kW at 400...415 V AC 50/60 Hz
22 kW at 400...415 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
22 kW at 660...690 V AC 50/60 Hz
30 kW at 660...690 V AC 50/60 Hz
45 kW at 660...690 V AC 50/60 Hz
Breaking capacity 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
control type Toggle
[In] rated current 50 A
Magnetic tripping current 300…700 A
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current 115 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Power dissipation per pole 6.1 W
Mechanical durability 40000 cycles
Electrical durability 20000 cycles for AC-3 at 440 V In/2
10000 cycles for AC-3 at 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Connection pitch 27 mm without spreaders
35 mm with spreaders
Connections - terminals Lugs-ring terminals
Tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
Mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Height 155 mm
Width 81 mm
Depth 116 mm
Product weight 1.5 kg
Colour Grey (RAL 7016)
Suitability for isolation Yes conforming to IEC 60947-1
Schneider New Stock Image
Schneider GV3P5050A Schneider
Sale price 1,580.00 kr
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LRD3357C Schneider
Sale price 990.00 kr
Only 10 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GVAPK11 Schneider Electric
Schneider GVAPK11 Schneider Electric
Sale price0.00 kr
Sold Out

Main

Characteristic Value(s)
Range TeSys
Product or Component Type Shaft bracket
Device short name GVAP
Accessory / separate part category Control accessory

Complementary

Characteristic Value(s)
Product Compatibility GV2APN01
GV2APN02
GV2APN03
GV2APN04
GVAPA1
Length 9.8 in (250 mm)
GV2LE22 Schneider Electric
Schneider GV2LE22 Schneider Electric
Sale price0.00 kr
Sold Out

Motor circuit breaker, TeSys GV2, 3P, 25 A, magnetic, toggle control, screw clamp terminals

GV4L50B6 Schneider Electric
Schneider GV4L50B6 Schneider Electric
Sale price0.00 kr
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 50 A, Icu 25 kA, magnetic, lugs terminals

GV4P25B Schneider Electric
Schneider GV4P25B Schneider Electric
Sale price0.00 kr
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic, Everlink terminals

GV4AU137 Schneider Electric
Schneider GV4AU137 Schneider Electric
Sale price0.00 kr
Sold Out

TeSys GV electrical trip unit, MN undervoltage release, 110-130V AC 50/60Hz and 125V DC, for motor circuit breakers GV4. Opening of the the circuit breaker is ensured when the control voltage drops below 0.35 Uc, and possible between 0.35-0.7 Uc. Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc. To be plugged inside the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA).

Main

Characteristic Value(s)
Range TeSys
Device short name MN
Product or Component Type Voltage release
Device Application Control
Range compatibility TeSys TeSys GV4
TeSys TeSys BV4
Voltage release type Undervoltage release
[Uc] control circuit voltage 110...130 V AC 50/60 Hz
125 V DC

Complementary

Characteristic Value(s)
[Ui] rated insulation voltage 130 V IEC 60947-1
Threshold tripping voltage < 0.35 Un failsafe opening
0.35...0.7 Un possible opening
0.85...1.1 Un enabled closing
Mounting Mode Internal mounting
Maximum inrush power in VA 7 VA
Maximum inrush power in W 2 W
Maximum hold-in power consumption in VA 7 VA
Maximum hold-in power consumption in W 2 W
Mechanical durability 20000 cycles
Operating time < 50 ms
Connections - terminals Spring terminals 1 0.0008…0.002 in² (0.5…1.5 mm²) - cable stiffness: flexible without cable end
Wire stripping length 0.3 in (8 mm)
GV6P500H Schneider Electric
Schneider GV6P500H Schneider Electric
Sale price0.00 kr
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 500A/690V, for protection of 3-phase motors 200-250kW@400V. It provides thermal magnetic protection and additional protections, breaking capacity Icu 70kA, start-stop control by rotary handle, connection for bars or cables with lugs (direct connection of cables with additional connectors). Thermal protection adjustable by dials with a setting current Ir in range 250-500A and a selectable tripping class 5, 10 or 20, magnetic protection at 13 In. Additional protections with fixed pick-up include short time delay protection Isd at 13 Ir, phase unbalance and loss protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range of product TeSys GV6
Range TeSys
Device short name GV6P
product name TeSys GV6
TeSys Giga
Product or component type Motor circuit breaker
Device application Motor protection
Trip unit technology Electronic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
Motor power kW 200…250 kW at 400/415 V AC 50/60 Hz
250…315 kW at 500 V AC 50/60 Hz
315…400 kW at 660/690 V AC 50/60 Hz
Breaking capacity 70 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
control type Direct rotary handle
[In] rated current 500 A at 65 °C
Magnetic tripping current 6500 A
[Ue] rated operational voltage 690 V AC 50/60 Hz
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current 500 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV
Power dissipation per pole 39.7 W
Mechanical durability 15000 cycles
Electrical durability 4000 cycles for AC-3 at 400/415 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous
Connection pitch 45 mm without spreaders
Connections - terminals Bars
Lugs
Tightening torque 50 N.m M10 screw type
Mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Height 255 mm
Width 140 mm
Depth 179 mm
Product weight 6.7 kg
Colour Anthracite (RAL 7016)
Suitability for isolation Yes conforming to EN/IEC 60947-2
GV2ME076 Schneider Electric
Schneider GV2ME076 Schneider Electric
Sale price0.00 kr
Sold Out

Motor circuit breaker, TeSys GV2, 3P, 1.6-2.5 A, thermal magnetic, lugs terminals

GV7AS055 Schneider Electric
Schneider GV7AS055 Schneider Electric
Sale price0.00 kr
Sold Out

Voltage release, TeSys GV5 GV6 GV7, MX shunt trip, 48V AC 50/60Hz

GV4PEM50S6 Schneider Electric
Schneider GV4PEM50S6 Schneider Electric
Sale price0.00 kr
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 20-50A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).

Main

Characteristic Value(s)
Range of Product TeSys GV4
Range TeSys Deca
Device short name GV4PEM
product name TeSys GV4
Product or Component Type Motor circuit breaker
Device Application Motor protection
Trip unit technology Electronic
Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Operating position Any position
Motor power kW 11 kW 400...415 V AC 50/60 Hz
15 kW 500 V AC 50/60 Hz
18.5 kW 660...690 V AC 50/60 Hz
15 kW 400...415 V AC 50/60 Hz
18.5 kW 400...415 V AC 50/60 Hz
22 kW 400...415 V AC 50/60 Hz
18.5 kW 500 V AC 50/60 Hz
22 kW 500 V AC 50/60 Hz
30 kW 500 V AC 50/60 Hz
22 kW 660...690 V AC 50/60 Hz
30 kW 660...690 V AC 50/60 Hz
37 kW 660...690 V AC 50/60 Hz
45 kW 660...690 V AC 50/60 Hz
Breaking capacity 120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2
100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2
70 kA Icu 440 V AC 50/60 Hz IEC 60947-2
30 kA Icu 500 V AC 50/60 Hz IEC 60947-2
18 kA Icu 525 V AC 50/60 Hz IEC 60947-2
100 kA 208Y/120 V AC 50/60 Hz UL 60947
100 kA 240 V AC 50/60 Hz UL 60947
65 kA 480Y/277 V AC 50/60 Hz UL 60947
10 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2
25 kA 600Y/347 V AC 50/60 Hz UL 60947
Control Type Toggle
Line Rated Current 50 A
Magnetic tripping current 850 A
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz IEC 60947-2
[Ith] conventional free air thermal current 115 A IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Power dissipation per pole 4.6 W
Mechanical durability 40000 cycles
Electrical durability 20000 cycles AC-3 440 V In/2
10000 cycles AC-3 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous IEC 60947-4-1
Connection pitch 1.06 in (27 mm) without spreaders
1.4 in (35 mm) with spreaders
Connections - terminals Lugs-ring terminals
Tightening torque 79.7 lbf.in (9 N.m) 0.02…0.1 in² (16…95 mm²)
44.3 lbf.in (5 N.m) 0.002…0.02 in² (1.5…10 mm²)
Mechanical robustness Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6
Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6
Shocks 15 gn 11 ms IEC 60068-2-27
Phase failure sensitivity Yes IEC 60947-4-1
Height 6.1 in (155 mm)
Width 3.2 in (81 mm)
Depth 4.6 in (116 mm)
Product Weight 3.20 lb(US) (1.45 kg)
color Gray RAL 7016)
Suitability for isolation Yes IEC 60947-1
GV4LE12N6 Schneider Electric
Schneider GV4LE12N6 Schneider Electric
Sale price0.00 kr
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 12.5 A, Icu 50 kA, magnetic, lugs terminals

GV4AU027 Schneider Electric
Schneider GV4AU027 Schneider Electric
Sale price0.00 kr
Sold Out

TeSys GV electrical trip unit, MN undervoltage release, 24V AC 50/60Hz and 24V DC, for motor circuit breakers GV4. Opening of the the circuit breaker is ensured when the control voltage drops below 0.35 Uc, and possible between 0.35-0.7 Uc. Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc. To be plugged inside the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA).

Main

Characteristic Value(s)
Range TeSys
Device short name MN
Product or Component Type Voltage release
Device Application Control
Range compatibility TeSys TeSys GV4
TeSys TeSys BV4
Voltage release type Undervoltage release
[Uc] control circuit voltage 24 V AC 50/60 Hz
24 V DC

Complementary

Characteristic Value(s)
[Ui] rated insulation voltage 24 V IEC 60947-1
Threshold tripping voltage < 0.35 Un failsafe opening
0.35...0.7 Un possible opening
0.85...1.1 Un enabled closing
Mounting Mode Internal mounting
Maximum inrush power in VA 7 VA
Maximum inrush power in W 2 W
Maximum hold-in power consumption in VA 7 VA
Maximum hold-in power consumption in W 2 W
Mechanical durability 20000 cycles
Operating time < 50 ms
Connections - terminals Spring terminals 1 0.0008…0.002 in² (0.5…1.5 mm²) - cable stiffness: flexible without cable end
Wire stripping length 0.3 in (8 mm)
GVAD1010 Schneider Electric
Schneider GVAD1010 Schneider Electric
Sale price 776.00 kr
Only 5 units left

TeSys GV2 & GV3 - auxiliary contact - 1 NO + 1 NO (fault)

GV4L115B Schneider Electric
Schneider GV4L115B Schneider Electric
Sale price0.00 kr
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 115 A, Icu 25 kA, magnetic, EverLink terminals

GV4LE25S Schneider Electric
Schneider GV4LE25S Schneider Electric
Sale price0.00 kr
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for protection of 3-phase motors 5.5-11kW@400V. It provides magnetic protection, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Magnetic protection adjustable by dial, setting range 6-14 In. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). To be used in association with a class 10 or 20 thermal overload relay to complete motor protection. Multi standards certified (IEC, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range of product TeSys GV4
Range TeSys Deca
Device short name GV4L
product name TeSys GV4
Product or component type Motor circuit breaker
Device application Motor protection
Trip unit technology Magnetic
Electronic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Operating position Any position
Motor power kW 7.5 kW at 660...690 V AC 50/60 Hz
5.5 kW at 400...415 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
9 kW at 660...690 V AC 50/60 Hz
11 kW at 660...690 V AC 50/60 Hz
7.5 kW at 400...415 V AC 50/60 Hz
9 kW at 400...415 V AC 50/60 Hz
11 kW at 400...415 V AC 50/60 Hz
9 kW at 500 V AC 50/60 Hz
11 kW at 500 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
15 kW at 660...690 V AC 50/60 Hz
18.5 kW at 660...690 V AC 50/60 Hz
Breaking capacity 120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
control type Toggle
[In] rated current 25 A
Magnetic tripping current 150…350 A
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current 115 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Power dissipation per pole 6.1 W
Mechanical durability 40000 cycles
Electrical durability 40000 cycles for AC-3 at 440 V In/2
20000 cycles for AC-3 at 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
Mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Height 155 mm
Width 81 mm
Depth 116 mm
Product weight 1.5 kg
Colour Grey (RAL 7016)
Suitability for isolation Yes conforming to IEC 60947-1
GV4L07N6 Schneider Electric
Schneider GV4L07N6 Schneider Electric
Sale price0.00 kr
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals

GV2PM16C Schneider
Schneider GV2PM16C Schneider
Sale price 838.00 kr
In stock, 11 units

TeSys Deca motor thermal magnetic circuit breaker GV2PM, knob (control), thermal outlet range: 9-14 A, screw clamp terminals

GV3P131 Schneider Electric
Schneider GV3P131 Schneider Electric
Sale price0.00 kr
Sold Out

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV3
Product or component type Motor circuit breaker
Device short name GV3P
Device application Motor protection
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Network frequency 50/60 Hz conforming to IEC 60947-2
Motor power kW 5.5 kW at 400/415 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
11 kW at 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
control type Rotary handle
[In] rated current 13 A
Thermal protection adjustment range 9…13 A conforming to IEC 60947-2
Magnetic tripping current 182 A
[Ith] conventional free air thermal current 13 A conforming to IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Power dissipation per pole 8 W
Mechanical durability 50000 cycles
Electrical durability 50000 cycles for AC-3 at 415 V In
Rated duty Uninterrupted conforming to IEC 60947-4-1
Tightening torque 5 N.m - on screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Mounting position Horizontal
Vertical
Width 55 mm
Height 132 mm
Depth 136 mm
Product weight 0.96 kg
Colour Dark grey

Recently viewed