Sinamics G120 POWER Module PM240 WITHOUT FILTER with BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 497 X 275 X 204 (HXWXD), FSE Protection IP20 WITHOUT Control Unit and BOP
Sinamics G120 POWER Module PM240 with BUILT IN CL. A FILTER with BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 635 X 275 X 204 (HXWXD), FSE Protection IP20 WITHOUT Control Unit and BOP
Sinamics G120 POWER Module PM240 WITHOUT FILTER with BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 419 X 275 X 204 (HXWXD), FSD Protection IP20 WITHOUT Control Unit and BOP
Sinamics G120 POWER Module PM240 with BUILT IN CL. A FILTER with BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD Protection IP20 WITHOUT Control Unit and BOP
Sinamics G120 POWER Module PM240 WITHOUT FILTER with BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 18,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 22KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 419 X 275 X 204 (HXWXD), FSD Protection IP20 WITHOUT Control Unit and BOP
Sinamics G120 POWER Module PM240 WITHOUT FILTER with BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 15KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 18,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 419 X 275 X 204 (HXWXD), FSD Protection IP20 WITHOUT Control Unit and BOP
Sinamics G120 POWER Module PM240 with BUILT IN CL. A FILTER with BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 7,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 11KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 334 X 189 X 185 (HXWXD), FSC Protection IP20 WITHOUT Control Unit and BOP
Sinamics G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG Input CT: 1.5KW; VT: 1.5KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) Protection IP20 AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE
Sinamics V20 3AC380-480V -15/+10% 47-63HZ RATED POWER 0.55KW with 150% OVERLOAD FOR 60SEC UNFILTERED I/O-INTERFACE: 4DI, 2DO,2AI,1AO FIELDBUS: USS/ MODBUS RTU with INBUILT BOP PROTECTION: IP20/ UL OPEN TYPE SIZE:FSA 90X150X146(WXHXD)
SINAMICS S120 SMART LINE MODULE INPUT: 3AC 380-480V, 50/60HZ OUTPUT: 600VDC, 8.3A, 5KW FRAME SIZE: BOOKSIZE INTERNAL AIR COOLING INCL. CONTROL VOLTAGE ADAPTER MODULES PAINTED
SINAMICS S120 SINGLE MOTOR MODULE INPUT: DC 600V OUTPUT: 3AC 400V, 60A FRAME SIZE: BOOKSIZE INTERNAL AIR COOLING OPTIMIZED PULSE SAMPLE AND SUPPORT OF THE EXTENDED SAFETY INTEGRATED FUNCTIONS INCL. DRIVE-CLIQ CABLE
Sinamics S120 ACTIVE Interface Module FOR 80KW ACTIVE LINE Module INPUT 3AC 380-480V, 50 60HZ
SINAMICS S120 CONTROL UNIT CU310 DP WITH PROFIBUS INTERFACE WITHOUT COMPACTFLASH CARD
Sinamics S120 CONVERTER POWER Module PM340 INPUT 3AC 380-480V, 50 60HZ OUTPUT 3AC 25A (11KW) FRAME SIZE BLOCKSIZE SIZE FSC INTERNAL AIR COOLING
SINAMICS S120 SINGLE MOTOR MODULE INPUT: DC 600V OUTPUT: 3AC 400V, 30A FRAME SIZE: BOOKSIZE INTERNAL AIR COOLING OPTIMIZED PULSE SAMPLE AND SUPPORT OF THE EXTENDED SAFETY INTEGRATED FUNCTIONS INCL. DRIVE-CLIQ CABLE
Control Module CUR for infeed and infeed/regenerative feedback units Notice
SIMOVERT Master drives Motion Control adapter module for Compact and installation devices ADB
SIMOVERT Master drives Motion Control Communication module PROFIBUS CBP2, Delivery without operating instructions
Rectifier interfaces Module PER2 for infeed/regenerative feedback Supply units with Designs H and K 3 AC 500-575V, 50/60 Hz and 660-690V 3AC, 50/60 Hz