Measurement Systems

42 products

Showing 25 - 42 of 42 products

Showing 25 - 42 of 42 products
View
keyence Stock Image
Keyence IM-H3EA Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence IM-6000 Keyence
Sale price0.00 kr
Sold Out
Buy the Keyence IM-6000 - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence IM-6000 is a direct drop-in replacement for existing installations and ships ready for integration.
keyence Stock Image
Keyence IM-SG2 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

IM-SG2

Type

Tempered stage glass

Applicable product

IM-7010, IM-7020

keyence Stock Image
Keyence IM-8020 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

IM-8020

Type

Head

Image sensor

1" 20-megapixel monochrome CMOS

Display

12.1" LCD monitor (WXGA: 1280 × 800)

Receiver lens

Double telecentric lens

Image measurement

Field of view

Wide-field measurement mode

200 × 200 mm 7.87" × 7.87" (4× R50 R1.97")

High-precision measurement mode

125 × 125 mm 4.92" × 4.92"

Minimum display unit

0.1 μm

Repeatability

Wide-field measurement mode

Without stage movement

±1 μm

With stage movement

±2 μm

High-precision measurement mode

Without stage movement

±0.5 μm

With stage movement

±1.5 μm

Measurement accuracy (±2σ)

Wide-field measurement mode

Without binding

±3.9 μm *1

With binding

±(7 + 0.02 L) μm *2

High-precision measurement mode

Without binding

±2 μm *3

With binding

±(4 + 0.02 L) μm *4

Outer diameter measurement

Measurement accuracy

Wide-field measurement mode

±(2.8 + 0.02 D) μm *5

High-precision measurement mode

±(1.4 + 0.04 D) μm *6

Light probe measurement

Measurable area (XY)

90 × 90 mm 3.54" × 3.54"

Maximum measurement depth

30 mm 1.18"

Light probe diameter

ø3 mm ø0.12"

Measuring force

0.015 N

Repeatability

±2 μm *7

Measurement accuracy

±(8 + 0.02 L) μm *8

External remote input

Non-voltage input (with and without contact)

External output

OK/NG/FAIL/MEAS.

PhotoMos output
Rated load: 24 VDC 0.5 A
ON resistance: 50 mΩ or lower

Interface

LAN

RJ-45 (10BASE-T/100BASE-TX/1000BASE-T)

USB 3.1

4 ports (rear: 4)

USB 2.0 series A

4 ports (front: 2, rear: 2)

Monitor output

DVI-D

Record

Hard disk drive

500 GB

Illumination system

Transparent

Telecentric transparent illumination

Ring

Four division, multi-angle illumination (electric), Slit ring (directivity) illumination (electric)

XY stage

Moving range

100 × 100 mm 3.94" × 3.94" (electric)

Withstand load

5 kg

Z stage

Moving range

75 mm 2.95" (electric)

Power supply

Power voltage

100 to 240 VAC ±10%, 50/60 Hz

Power consumption

430 VA or lower

Environmental resistance

Ambient temperature

+10 to 35°C +50°F to 95°F

Relative humidity

20 to 80% RH (no condensation)

Overvoltage category

II

Pollution degree

2

Weight

Approx. 30 kg

*1 In the range of ø80 mm ø3.15", within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F at the focal point position.
*2 In the range of 180 × 180 mm 7.09" × 7.09" (4× R40 R1.57"), within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F at the focal point position, and with a load weighing 2 kg or less on the stage. L is the amount of stage movement (in mm inch).
*3 In the range of ø20 mm 0.79", within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F at the focal point position.
*4 In the range of 120 × 120 mm 4.72" × 4.72", within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F at the focal point position, and with a load weighing 2 kg or less on the stage. L is the amount of stage movement (in mm inch).
*5 Within the range of L118 mm × ø60 mm L4.65" × ø2.36". At the focal point position, with the part positioned in the center of the lens field of view, and with the shaft direction of the part facing the horizontal direction of the lens field of view. Within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F. D is the Y direction distance (in mm inch).
*6 Within the range of L106 mm × ø20 mm L4.17" × ø0.79". At the focal point position, with the part positioned in the center of the lens field of view, and with the shaft direction of the part facing the horizontal direction of the lens field of view. Within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F. D is the Y direction distance (in mm inch).
*7 When the detection system is standard. If the detection system is at a deep position, ±3 μm.
*8 When the detection system is standard, within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F, and with a load weighing 2 kg or less on the stage. If the detection system is at a deep position, ±(10 + 0.02 L) μm with L as the measurement length (in mm inch).

keyence Stock Image
Keyence IM-SG3 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence IM-7000 Keyence
Sale price 392,264.00 kr
Only 3 units left
Buy the Keyence IM-7000 - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence IM-7000 is a direct drop-in replacement for existing installations and ships ready for integration.
Keyence Stock Image
Keyence IM-6145 Keyence
Sale price 122,409.00 kr
Only 4 units left
Buy the Keyence IM-6145 - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence IM-6145 is a direct drop-in replacement for existing installations and ships ready for integration.
keyence Stock Image
Keyence IM-XC100TL Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

IM-XC100TL

Type

Head

Image measurement

Field of view

Wide-field mode [mm inch]

ø100 ø3.94"

High-precision mode [mm inch]

25 0.98" × 25 0.98"

Minimum display unit

0.1 μm

Repeatability

Within field of view (2σ)

Wide-field mode

1 µm

High-precision mode

0.5 μm

Measurement accuracy

Wide-field mode

3.5 µm*1

High-precision mode

1.8 µm*2

Laser height

Reference distance

70 mm 2.76"

Repeatability

σ ≦ 0.6 µm

Spot diameter

ø50 µm

Linearity

±2 μm*3

Laser class

Class 1

Touch probe

Repeatability

±1 μm

Measuring force

0.015 N*4

AF height

Repeatability

Illumination system

Transparent

Green LED, telecentric transparent illumination

Coaxial

Color LED, white LED, four-division multi-angle illumination (electric)

Green LED, slit ring (directivity) lateral illumination (electric)

White LED coaxial illumination (optional)

Environmental resistance

Ambient temperature

+10 to 35°C +50°F to 95°F

Weight

12 kg 26.46 lb

*1 In the range of ø80 mm ø3.15", within the operating ambient temperature range of +23±1°C +73.4±1.8°F at the focal point position.
*2 In the range of 20 × 20 mm 0.79" × 0.79", within the operating ambient temperature range of +23±1°C +73.4±1.8°F at the focal point position.
*3 Value measured with KEYENCE reference workpiece, laser stand-alone performance.
*4 Reference value

keyence Stock Image
Keyence IM-XC100T Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

IM-XC100T

Type

Head

Image measurement

Field of view

Wide-field mode [mm inch]

ø100 ø3.94"

High-precision mode [mm inch]

25 0.98" × 25 0.98"

Minimum display unit

0.1 μm

Repeatability

Within field of view (2σ)

Wide-field mode

1 µm

High-precision mode

0.5 μm

Measurement accuracy

Wide-field mode

3.5 µm*1

High-precision mode

1.8 µm*2

Laser height

Reference distance

Repeatability

Spot diameter

Linearity

Laser class

Touch probe

Repeatability

±1 μm

Measuring force

0.015 N*3

AF height

Repeatability

Illumination system

Transparent

Green LED, telecentric transparent illumination

Coaxial

Color LED, white LED, four-division multi-angle illumination (electric)

Green LED, slit ring (directivity) lateral illumination (electric)

White LED coaxial illumination (optional)

Environmental resistance

Ambient temperature

+10 to 35°C +50°F to 95°F

Weight

11 kg 24.25 lb

*1 In the range of ø80 mm ø3.15", within the operating ambient temperature range of +23±1°C +73.4±1.8°F at the focal point position.
*2 In the range of 20 × 20 mm 0.79" × 0.79", within the operating ambient temperature range of +23±1°C +73.4±1.8°F at the focal point position.
*3 Reference value

keyence Stock Image
Keyence IM-XDXW Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence IM-8001 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

IM-8001

Type

Controller

Image sensor

1" 20-megapixel monochrome CMOS

Display

12.1" LCD monitor (WXGA: 1280 × 800)

Receiver lens

Double telecentric lens

Image measurement

Field of view

Wide-field measurement mode

IM-8005: ø100 mm ø3.94"
IM-8020: 200 × 200 mm 7.87" × 7.87" (4× R50 R1.97")
IM-8030: 300 × 200 mm 11.81" × 7.87" (4× R50 R1.97")

High-precision measurement mode

IM-8005: 25 × 25 mm 0.98" × 0.98"
IM-8020: 125 × 125 mm 4.92" × 4.92"
IM-8030: 225 × 125 mm 8.86" × 4.92"

Minimum display unit

0.1 μm

Repeatability

Wide-field measurement mode

Without stage movement

±1 μm

With stage movement

IM-8005: —
IM-8020: ±2 μm
IM-8030: ±2 μm

High-precision measurement mode

Without stage movement

±0.5 μm

With stage movement

IM-8005: —
IM-8020: ±1.5 μm
IM-8030: ±1.5 μm

Measurement accuracy (±2σ)

Wide-field measurement mode

Without binding

±3.9 μm *1

With binding

IM-8005: —
IM-8020: ±(7 + 0.02 L) μm *2
IM-8030: ±(7 + 0.02 L) μm *3

High-precision measurement mode

Without binding

±2 μm *4

With binding

IM-8005: —
IM-8020: ±(4 + 0.02 L) μm *5
IM-8030: ±(4 + 0.02 L) μm *6

Outer diameter measurement

Measurement accuracy

Wide-field measurement mode

IM-8005: ±(2.8 + 0.02 D) μm *7
IM-8020: ±(2.8 + 0.02 D) μm *8
IM-8030: ±(2.8 + 0.02 D) μm *9

High-precision measurement mode

IM-8005: ±(1.4 + 0.04 D) μm *10
IM-8020: ±(1.4 + 0.04 D) μm *11
IM-8030: ±(1.4 + 0.04 D) μm *12

Light probe measurement

Measurable area (XY)

IM-8005: —
IM-8020: 90 × 90 mm 3.54" × 3.54"
IM-8030: 190 × 90 mm 7.48" × 3.54"

Maximum measurement depth

IM-8005: —
IM-8020: 30 mm 1.18"
IM-8030: 30 mm 1.18"

Light probe diameter

IM-8005: —
IM-8020: ø3 mm ø0.12"
IM-8030: ø3 mm ø0.12"

Measuring force

IM-8005: —
IM-8020: 0.015 N
IM-8030: 0.015 N

Repeatability

IM-8005: —
IM-8020: ±2 μm *13
IM-8030: ±2 μm *13

Measurement accuracy

IM-8005: —
IM-8020: ±(8 + 0.02 L) μm *14
IM-8030: ±(8 + 0.02 L) μm *15

External remote input

Non-voltage input (with and without contact)

External output

OK/NG/FAIL/MEAS.

PhotoMos output
Rated load: 24 VDC 0.5 A
ON resistance: 50 mΩ or lower

Interface

LAN

RJ-45 (10BASE-T/100BASE-TX/1000BASE-T)

USB 3.1

4 ports (rear: 4)

USB 2.0 series A

4 ports (front: 2, rear: 2)

Monitor output

DVI-D

Record

Hard disk drive

500 GB

Illumination system

Transparent

Telecentric transparent illumination

Ring

IM-8005: Four division ring illumination
IM-8020: Four division, multi-angle illumination (electric), Slit ring (directivity) illumination (electric)
IM-8030: Four division, multi-angle illumination (electric), Slit ring (directivity) illumination (electric)

XY stage

Moving range

IM-8005: —
IM-8020: 100 × 100 mm 3.94" × 3.94" (electric)
IM-8030: 200 × 100 mm 7.87" × 3.94" (electric)

Withstand load

IM-8005: 5 kg
IM-8020: 5 kg
IM-8030: 7.5 kg

Z stage

Moving range

75 mm 2.95" (electric)

Power supply

Power voltage

100 to 240 VAC ±10%, 50/60 Hz

Power consumption

430 VA or lower

Environmental resistance

Ambient temperature

+10 to 35°C +50°F to 95°F

Relative humidity

20 to 80% RH (no condensation)

Overvoltage category

II

Pollution degree

2

Weight

Approx. 8 kg

*1 In the range of ø80 mm ø3.15", within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F at the focal point position.
*2 In the range of 180 × 180 mm 7.09" × 7.09" (4× R40 R1.57"), within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F at the focal point position, and with a load weighing 2 kg or less on the stage. L is the amount of stage movement (in mm inch).
*3 In the range of 280 × 180 mm 11.02" × 7.09" (4× R40 R1.57"), within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F at the focal point position, and with a load weighing 3 kg or less on the stage. L is the amount of stage movement (in mm inch).
*4 In the range of ø20 mm 0.79", within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F at the focal point position.
*5 In the range of 120 × 120 mm 4.72" × 4.72", within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F at the focal point position, and with a load weighing 2 kg or less on the stage. L is the amount of stage movement (in mm inch).
*6 In the range of 220 × 120 mm 8.66" × 4.72", within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F at the focal point position, and with a load weighing 3 kg or less on the stage. L is the amount of stage movement (in mm inch).
*7 Within the range of L18 mm × ø60 mm L0.71" × ø2.36". At the focal point position, with the part positioned in the center of the lens field of view, and with the shaft direction of the part facing the horizontal direction of the lens field of view. Within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F. D is the Y direction distance (in mm inch).
*8 Within the range of L118 mm × ø60 mm L4.65" × ø2.36". At the focal point position, with the part positioned in the center of the lens field of view, and with the shaft direction of the part facing the horizontal direction of the lens field of view. Within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F. D is the Y direction distance (in mm inch).
*9 Within the range of L218 mm × ø60 mm L8.58" × ø2.36". At the focal point position, with the part positioned in the center of the lens field of view, and with the shaft direction of the part facing the horizontal direction of the lens field of view. Within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F. D is the Y direction distance (in mm inch).
*10 Within the range of L6 mm × ø20 mm L0.24" × ø0.79". At the focal point position, with the part positioned in the center of the lens field of view, and with the shaft direction of the part facing the horizontal direction of the lens field of view. Within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F. D is the Y direction distance (in mm inch).
*11 Within the range of L106 mm × ø20 mm L4.17" × ø0.79". At the focal point position, with the part positioned in the center of the lens field of view, and with the shaft direction of the part facing the horizontal direction of the lens field of view. Within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F. D is the Y direction distance (in mm inch).
*12 Within the range of L206 mm × ø20 mm L8.11" × ø0.79". At the focal point position, with the part positioned in the center of the lens field of view, and with the shaft direction of the part facing the horizontal direction of the lens field of view. Within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F. D is the Y direction distance (in mm inch).
*13 When the detection system is standard. If the detection system is at a deep position, ±3 μm.
*14 When the detection system is standard, within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F, and with a load weighing 2 kg or less on the stage. If the detection system is at a deep position, ±(10 + 0.02 L) μm with L as the measurement length (in mm inch).
*15 When the detection system is standard, within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F, and with a load weighing 3 kg or less on the stage. If the detection system is at a deep position, ±(10 + 0.02 L) μm with L as the measurement length (in mm inch).

keyence Stock Image
Keyence IM-8030 Keyence
Sale price 478,506.00 kr
Only 1 unit left

Specifications

Model

IM-8030

Type

Head

Image sensor

1" 20-megapixel monochrome CMOS

Display

12.1" LCD monitor (WXGA: 1280 × 800)

Receiver lens

Double telecentric lens

Image measurement

Field of view

Wide-field measurement mode

300 × 200 mm 11.81" × 7.87" (4× R50 R1.97")

High-precision measurement mode

225 × 125 mm 8.86" × 4.92"

Minimum display unit

0.1 μm

Repeatability

Wide-field measurement mode

Without stage movement

±1 μm

With stage movement

±2 μm

High-precision measurement mode

Without stage movement

±0.5 μm

With stage movement

±1.5 μm

Measurement accuracy (±2σ)

Wide-field measurement mode

Without binding

±3.9 μm *1

With binding

±(7 + 0.02 L) μm *2

High-precision measurement mode

Without binding

±2 μm *3

With binding

±(4 + 0.02 L) μm *4

Outer diameter measurement

Measurement accuracy

Wide-field measurement mode

±(2.8 + 0.02 D) μm *5

High-precision measurement mode

±(1.4 + 0.04 D) μm *6

Light probe measurement

Measurable area (XY)

190 × 90 mm 7.48" × 3.54"

Maximum measurement depth

30 mm 1.18"

Light probe diameter

ø3 mm ø0.12"

Measuring force

0.015 N

Repeatability

±2 μm *7

Measurement accuracy

±(8 + 0.02 L) μm *8

External remote input

Non-voltage input (with and without contact)

External output

OK/NG/FAIL/MEAS.

PhotoMos output
Rated load: 24 VDC 0.5 A
ON resistance: 50 mΩ or lower

Interface

LAN

RJ-45 (10BASE-T/100BASE-TX/1000BASE-T)

USB 3.1

4 ports (rear: 4)

USB 2.0 series A

4 ports (front: 2, rear: 2)

Monitor output

DVI-D

Record

Hard disk drive

500 GB

Illumination system

Transparent

Telecentric transparent illumination

Ring

Four division, multi-angle illumination (electric), Slit ring (directivity) illumination (electric)

XY stage

Moving range

200 × 100 mm 7.87" × 3.94" (electric)

Withstand load

7.5 kg

Z stage

Moving range

75 mm 2.95" (electric)

Power supply

Power voltage

100 to 240 VAC ±10%, 50/60 Hz

Power consumption

430 VA or lower

Environmental resistance

Ambient temperature

+10 to 35°C +50°F to 95°F

Relative humidity

20 to 80% RH (no condensation)

Overvoltage category

II

Pollution degree

2

Weight

Approx. 33 kg

*1 In the range of ø80 mm ø3.15", within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F at the focal point position.
*2 In the range of 280 × 180 mm 11.02" × 7.09" (4× R40 R1.57"), within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F at the focal point position, and with a load weighing 3 kg or less on the stage. L is the amount of stage movement (in mm inch).
*3 In the range of ø20 mm 0.79", within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F at the focal point position.
*4 In the range of 220 × 120 mm 8.66" × 4.72", within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F at the focal point position, and with a load weighing 3 kg or less on the stage. L is the amount of stage movement (in mm inch).
*5 Within the range of L218 mm × ø60 mm L8.58" × ø2.36". At the focal point position, with the part positioned in the center of the lens field of view, and with the shaft direction of the part facing the horizontal direction of the lens field of view. Within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F. D is the Y direction distance (in mm inch).
*6 Within the range of L206 mm × ø20 mm L8.11" × ø0.79". At the focal point position, with the part positioned in the center of the lens field of view, and with the shaft direction of the part facing the horizontal direction of the lens field of view. Within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F. D is the Y direction distance (in mm inch).
*7 When the detection system is standard. If the detection system is at a deep position, ±3 μm.
*8 When the detection system is standard, within the operating ambient temperature range of +23 ±1°C +73.4°F ±1.8°F, and with a load weighing 3 kg or less on the stage. If the detection system is at a deep position, ±(10 + 0.02 L) μm with L as the measurement length (in mm inch).

keyence Stock Image
Keyence IM-G23 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence IM-PH4 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence IM-X1220 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

IM-X1220

Type

Stage unit

Head used

IM Head, LM Head

Measurement range (X × Y)

Image measurement

Wide-field mode [mm inch]

IM Head: 200 × 200 7.87" × 7.87", LM Head: 125 × 125 4.92" × 4.92"

High-precision mode [mm inch]

IM Head: 125 × 125 4.92" × 4.92", LM Head: 106 × 106 4.17" × 4.17"

AF height [mm inch]

IM Head: —, LM Head: 100 × 100 3.94" × 3.94"

Laser height [mm inch]

Touch probe [mm inch]

Z stage

Moving range [mm inch]

150 5.91"

Measurement accuracy

X/Y axis (EUX, MPE EUY, MPE)

1.8 + 0.02 L µm*1 *2

X/Y plane (EUXY, MPE)

2.8 + 0.02 L µm*1 *2

Z axis (EUZ, MPE)

IM Head: —, LM Head: 3.8 + 0.04 L µm*3 *4

Load capacity

15 kg*5 33.07 lb

Ratings

Power voltage

24 VDC

Current consumption

7.5 A

Environmental resistance

Ambient temperature

+10 to 35°C*6 +50°F to 95°F

Weight

29 kg 63.93 lb

*1 In accordance with ISO10360-7, L is the amount of X/Y stage movement (in mm) when within the operating ambient temperature range of +23±1°C +73.4±1.8°F and with a load weighing 2 kg 4.41 lb or less on the stage.
*2 In accordance with ISO10360-2 when measuring with touch probe; X/Y axis 2.8 + 0.02 L µm; XY plane 3.8 + 0.02 L µm.
*3 In accordance with ISO10360-7; in accordance with ISO10360-2 when measuring with touch probe; L is the amount of Z stage movement (in mm) when within the operating ambient temperature range of +23±1°C +73.4±1.8°F; with KEYENCE reference workpiece; with maximum measurement target height setting of 62 mm 2.44" or less.
*4 At 3.8 + 0.08 L µm if the maximum measurement target height exceeds 62 mm 2.44".
*5 5 kg 11.02lb at XY stage travel speed of 120 mm/s 4.72"/s.
*6 +15 to 35°C +59°F to 95°F at XY stage travel speed of 120 mm/s 4.72"/s.

keyence Stock Image
Keyence IM-DXW12NT Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence IM-XC100 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

IM-XC100

Type

Head

Image measurement

Field of view

Wide-field mode [mm inch]

ø100 ø3.94"

High-precision mode [mm inch]

25 0.98" × 25 0.98"

Minimum display unit

0.1 μm

Repeatability

Within field of view (2σ)

Wide-field mode

1 µm

High-precision mode

0.5 μm

Measurement accuracy

Wide-field mode

3.5 µm*1

High-precision mode

1.8 µm*2

Laser height

Reference distance

Repeatability

Spot diameter

Linearity

Laser class

Touch probe

Repeatability

Measuring force

AF height

Repeatability

Illumination system

Transparent

Green LED, telecentric transparent illumination

Coaxial

Color LED, white LED, four-division multi-angle illumination (electric)

Green LED, slit ring (directivity) lateral illumination (electric)

White LED coaxial illumination (optional)

Environmental resistance

Ambient temperature

+10 to 35°C +50°F to 95°F

Weight

10 kg 22.05 lb

*1 In the range of ø80 mm ø3.15", within the operating ambient temperature range of +23±1°C +73.4±1.8°F at the focal point position.
*2 In the range of 20 × 20 mm 0.79" × 0.79", within the operating ambient temperature range of +23±1°C +73.4±1.8°F at the focal point position.

keyence Stock Image
Keyence IM-H1T Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

IM-H1T

Operating System

Windows 11, Windows 10 (64bit)

CPU

2 GHz or more (Corei3 or more)

Display

1024 x 768 pixels or greater

Memory capacity

4GB or more

Connection interface

Serial port or USB port

Available hard disk space

2GB or more

Software

.NET FrameWork 4.6.2 or later must be installed.
Microsoft Excel 2016 or later, and language pack with the same language as the OS must be installed.

Note

-