PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


Specifications
Model |
OP-88895 |
|||
Female |
M12 8-pin Straight |
|||
Male |
Strand wire |
|||
Length |
10 m 32.8' |
|||
Material |
cable: PVC |
|||

Specifications
Model |
LV-H37 |
|||
Type |
Ultra-small beam spot |
|||
FDA (CDRH) Part 1040.10 |
Class II |
|||
Light source |
Visible red semiconductor laser |
|||
Wavelength |
660 nm |
|||
Detecting distance |
FINE |
70 ±15 mm 2.76" ±0.59" |
||
TURBO | ||||
SUPER | ||||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Case |
Glass reinforced plastic *1 |
||
Lens cover |
Glass *2 |
|||
Weight |
Approx. 45 g |
|||
*1 Norbornene plastic or acrylic | ||||

Specifications
Model |
GL-RS3 |
|||
Type |
Joint Cable |
|||
Number included |
1 cable |
|||
Cable end |
Both ends of the connector (Black) are the same shape. The connector can be connected in either direction. |
|||
Length |
3 m 9.84' |
|||
Material |
Main unit connection connector: PBT, Cable: PVC |
|||
Note |
Use this when using the product in a one-line system or when connecting the product in series. |
|||
Weight |
Approx. 165 g |
|||

Specifications
Model |
AP-13SK |
|||
Type |
Positive Sensor Head |
|||
Rated pressure |
0 to 145 PSI |
|||
Fluid type |
Gases and liquids compatible with 304 and 630 stainless steel |
|||
Type of pressure |
Gauge pressure |
|||
Repeatability |
0.5 % of F.S. max. |
|||
Connection port |
1/8 NPT |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Pressure resistance |
290 PSI |
|||
Ambient temperature |
-10 to 70°C(14 to 158°F), No condensation |
|||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 3 hours respectively |
|||
Shock resistance |
500 m/s2 in X, Y, and Z directions 10 times respectively (60 times in total) |
|||
Material |
Diaphragm pressure port: TYPE S17400 stainless steel, Pressure port: 304 stainless steel, Throttle: 304 stainless steel (AP-14SK/15SK/16SK only) |
|||
Accessories |
Sensor head connector: 1 |
|||
Weight |
Approx. 120 g |
|||

Specifications
Model |
GL-RP30P |
|||
Type |
Unit connection cable |
|||
Number included |
1 cable |
|||
Cable end |
Main unit plug (Black) - Loose wires |
|||
Length |
30 m 98.42' |
|||
Material |
Main unit connection connector: PBT, Cable: PVC |
|||
Note |
Brown and blue: 22 AWG (nominal cross section: 0.34 mm2), other: 26 AWG (nominal cross section: 0.14 mm2) |
|||
Weight |
Approx. 1200 g |
|||

Specifications
Model |
MP-FG10R |
|||
Type |
Standard model |
|||
Connection bore diameter |
G3/8" (10 A) |
|||
Supported gases |
Air and non-corrosive gases |
|||
Supported gas temperature |
-5 to +50°C, 23 to 122°F |
|||
Operating pressure range |
0.2 to 1 MPa, 2 to 10 bar, 29 to 145 psi *1 |
|||
Pressure resistance |
1.5 MPa, 15 bar, 217.5 psi |
|||
Flow rate |
Detection principle |
Heat based (mass flow rate) |
||
Rated flow range (normal) |
2.0 to 1000.0 L/min |
|||
Zero cut flow rate |
2.0 L/min, 0.12 m3/h 4.24 ft3/h, 0.07 CFM |
|||
Measurement accuracy |
±(1.5% of RD + 0.5% of F.S.) *2 *3 |
|||
Repeatability |
±1.0% of F.S. (with an averaging time of 1.0 s) |
|||
Display resolution |
0.1 L/min, 0.01 m3/h 0.35 ft3/h, 0.01 CFM |
|||
Response time |
150 ms (63% response) *4 |
|||
Averaging time |
OFF/100 ms/200 ms/500 ms/1.0 s/3.0 s/5.0 s/10 s/30 s (selectable) |
|||
Pressure (Digital value, gauge pressure) |
Rated pressure range |
0.000 to 1.000 MPa, 0.00 to 10.00bar, 0.0 to 145.0 psi |
||
Measurement accuracy |
±2.0% of F.S. |
|||
Repeatability |
±0.2% of F.S. (with a response time of 50 ms) |
|||
Display resolution |
0.001 MPa, 0.01 bar, 0.1 psi |
|||
Response time |
Selectable from 10 ms, 50 ms, 100 ms, 500 ms, 1.0 s, and 5.0 s *4 |
|||
Humidity (Dew point) |
Rated relative humidity range/ dew point range |
15 to 100%RH (no condensation)/Corresponds to the relative humidity range *5 *6 |
||
Measurement accuracy |
±4°C, ±7°F *5 *6 |
|||
Display resolution |
5%RH/1°C, 1°F *5 *6 |
|||
Temperature |
Measurement accuracy |
±2.0°C, ±3.6°F *7 |
||
Display resolution |
0.1°C, 0.1°F *7 |
|||
Shut-off valve |
Response time |
1 s or less (closed → open) |
||
Leakage amount |
50 mL/min 0.002 CFM (N) or less |
|||
Filter/regulator (Standard model only) |
Pressure adjustment range |
0.15 to 0.90 MPa |
||
Filtration degree |
5 μm 0.196850 Mil |
|||
Drainage cup capacity |
60 cc |
|||
Check valve |
Available |
|||
Display |
Color LCD, status indicator |
|||
Data accumulation |
Accumulation period |
Accumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks |
||
Data reading |
USB 2.0/Ethernet |
|||
I/O |
Control output (Ch.1/2/3/4/5) |
NPN/PNP setting switchable, open collector output 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA/Ch., residual voltage: 2.5 V or less |
||
Analog output (Ch.1/2) |
4 to 20 mA, load resistance: 260 Ω or less *4 |
|||
External input (Ch.2/3/6) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, reverse connection protection for each I/O, surge protection for each I/O, overcurrent protection for each output |
|||
Power supply |
Power voltage |
24 VDC +25%/-20% (including ripple), Class 2 or LPS |
||
Power consumption |
1.2 A (300 ms) when opening/closing valve, 100 mA at all other times *8 (standalone usage; excluding load current) |
|||
Communication interface |
USB2.0 |
|||
Network compatibility |
When using only this unit: IO-Link (Specification v1.1/COM3) *9 |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) *10 |
||
Ambient temperature |
−5°C to +50°C 23°F to 122°F (no freezing) *11 |
|||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; power spectral density: 0.204 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
300 m/s2, XYZ axes, 10 times for each axis |
|||
Material |
Sensor part : PET/PPS/PBT/POM/aluminum/SPHC |
|||
Weight |
Approx. 1050 g 37.04 oz (excluding drainage cup) |
|||
*1 An upstream side pressure of 0.2 MPa or less (a filter/regulator adjustment pressure of 0.2 MPa or less for the standard model) worsens the flow rate characteristic of the shut-off valve. | ||||


Specifications
Model |
VS-S320CX |
|||
Storage |
Internal storage |
7 GB |
||
microSD card (external) |
Max. 64 GB *1 |
|||
Image sensor |
Frame rate |
83 fps |
||
Lens |
Mount |
Lens-integrated type |
||
Max. optical magnification |
× 2.4 |
|||
Installation distance |
50 mm to 500 mm 1.97" to 19.69" *2 |
|||
Field of view |
22 mm to 417 mm 0.87" to 16.42" |
|||
I/O connection |
Number of inputs |
1 (insulated) |
||
Number of outputs |
3 (insulated) |
|||
Number of inputs/outputs |
2 (insulated) (input and output switched via settings) |
|||
I/F |
Ethernet |
PoE IEEE 802.3at, M12 X cable × 1 |
||
I/O |
1 In/3 Out/2 In, Out M12 A cable × 1 |
|||
Lighting interface |
Dedicated lighting connection interface × 1 |
|||
External media |
microSD card slot × 1 (UHS-1) |
|||
Functions |
Imaging mode |
1.6 M |
||
Output image pixels |
(3.2 M mode) |
|||
Exposure time |
0.028 msec to 1000 msec |
|||
Image correction functions |
Gain, Offset, Gamma correction, White balance, Fine HDR |
|||
Indicators |
OLED display, Status LED, Ethernet LED (LINK/ACT), SD card access indicator |
|||
Buttons |
Operation buttons × 3 |
|||
Installation support functions |
Pointer (Class 1 laser product *3), Angle monitor |
|||
Power supply |
Power voltage |
24 V +25%/−20% or PoE (IEEE802.3at Power Class 4) |
||
Current consumption (camera only) |
0.97 A, 18.7 W (for 19.2 V)/0.78 A, 18.7 W (for 24 V) |
|||
Current consumption (including lighting) |
4.7 A, 89.7 W (for 19.2 V)/3.8 A, 89.7 W (for 24 V) |
|||
Current consumption (With CA-DEx10X connected) |
11.3 A, 216.7 W (for 19.2 V)/9.1 A, 216.7 W (for 24 V) *4 |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Relative humidity |
85% RH or below (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.05 G2/Hz; X, Y, and Z directions, 0.5 hours (IEC60068-2-64) |
|||
Shock resistance |
50 G, 3 times in each of the 6 directions (IEC60068-2-27) |
|||
Size (H×W×D) |
122.3 mm × 52.6 mm × 69.2 mm 4.81" × 2.07" × 2.72" |
|||
Case temperature |
0°C to 65°C 32 to 149°F *5 |
|||
Standard certifications |
CE, FCC, NRTL, KC, UKCA |
|||
Material |
Case: Aluminum die-casting, Front cover: Glass *6 |
|||
Weight |
Approx. 570 g 20.12 oz |
|||
*1 Using the configuration software, format the media before use. | ||||

Specifications
Model |
OP-87669 |
|||
Type |
Spacer for flat |
|||
Applicable product |
PR-F Series |
|||
Number included |
2 sets |
|||
Material |
SUS303 |
|||
Weight |
Approx. 1 g |
|||


Specifications
Model |
ER-U08TPC *1 *2 |
|||
Type |
Ultra-long distance unshielded type Screw type M8 Connector (M8 3-pin) PNP output |
|||
Power supply cable length |
― *3 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
Available |
|||
Button |
Function |
Distance switching |
||
Detecting distance |
With default settings (Mode 1) |
9 mm 0.35" ±10% *4 |
||
With distance switching (Mode 2) |
6 mm 0.24" ±10% *4 |
|||
Response frequency |
With default settings (Mode 1) |
15 Hz *5 *6 |
||
With distance switching (Mode 2) |
45 Hz *5 *6 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *7 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
27 × 27 mm 1.06" × 1.06" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
PNP output: 2.2 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
750 mW or less |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *10 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 (50 G), |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 20 g 0.71 oz |
|||
*1 Supports IO-Link specification v1.1/COM2 (38.4 kbps). | ||||



Specifications
Model |
CA-DBW12W |
|||
Type |
Bar Light |
|||
LED color |
White |
|||
Diffusion plate |
A diffusion plate is included with the CA-DBWxxW. The thickness of the diffusion plate is approximately 2 mm 0.08". |
|||
Power consumption |
13.8 W |
|||
Input voltage |
12 VDC |
|||
Polarizing diffusion plate |
OP-87975*1 |
|||
Weight |
Approx. 195 g |
|||
*1 The included diffusion plate and polarizing diffusion plate cannot be used with the product at the same time. There may be air bubbles or foreign substances on the surface of the polarizing diffusion plate, but these have no effect on the image quality. Even if such substances are present, the product is still within the inspection standards, and these substances do not indicate that the product is defective. | ||||

Specifications
Model |
EX-V02P*1 |
|||
Type |
Amplifier Unit PNP |
|||
Shape |
M10 x 18 mm 0.71" Threaded |
|||
Measuring range |
0 to 2 mm 0.08" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
0.4 μm |
|||
Sampling rate |
40,000 samplings max./sec. *2 |
|||
Display speed |
20 times/sec. |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
PNP: Applied voltage; 10 to 30 V |
|||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms |
|||
Strobe output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *3 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10%, Ripple (P-P): 10% max. |
||
Current consumption |
240 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to 50°C 32 to 122 °F |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 235 g |
|||
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials. | ||||

Specifications
Model |
ER-GL12N |
|||
Type |
General-purpose all-metal shielded type Screw type M12 Cable NPN output Long-Range |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
7 mm 0.28" ±10% *2 |
|||
Response frequency |
100 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
21 × 21 mm 0.83" × 0.83" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs |
|||
Control output |
Residual voltage |
NPN output: 0.9 V or less (Output current: 10 mA or less) / 1.4 V or less (Output current: 10 to 50 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
1000 mW or less |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), IP67G (JIS C 0920) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: SUS303, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 75 g |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections. | ||||