PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


Specifications
Model |
OP-84225 |
|||
Type |
M18 Nut |
|||
Applicable product |
Threaded PZ-G |
|||
Number included |
2 pcs. |
|||
Material |
Glass reinforced polybutylene terephthalate |
|||
Weight |
Approx. 5 g |
|||


Specifications
Model |
SV-C20F |
|||
Type |
Motor power cable, Standard |
|||
Length |
20 m 65.6' |
|||
Note |
for 3 kW / 5 kW motor |
|||

Specifications
Model |
BC-1000 |
|||
Camera |
High resolution |
5472 × 3648 |
||
CMOS |
20 megapixels |
|||
Counting |
Measurement area |
ø105 mm ø4.13" |
||
Supported samples |
Petri dishes, well plates, and culture film |
|||
Observation |
Front camera |
Included (with variable tilting and support for 2D codes) |
||
Lighting type |
Automatic variable illumination |
|||
Lens |
Proprietary high-resolution lens |
|||
Image format |
JPEG, TIFF |
|||
Recording |
Output format |
Excel, PDF, CSV |
||
Operation |
Center console |
Included |
||
Dimensions |
Outer dimensions |
364 × 518 × 615 mm 14.33"×20.39"×24.21" |
||
Software |
Supported OS |
Windows 11, Windows 10 |
||
Power supply |
Power voltage |
100 to 240 VAC ±10%, 50/60 Hz |
||
Power consumption |
240 VA |
|||
Environmental resistance |
Ambient temperature |
+15°C to 35°C +59°F to 95°F |
||
Relative humidity |
35% to 80% RH (no condensation) |
|||
Weight |
23 kg 50.71 lb (Main unit) |
|||

Specifications
Model |
SJ-U1 |
|||
Rating |
Rating input |
100 to 240 VAC (50/60Hz) 96VA*1 |
||
Rated output |
24 VDC 1.67A |
|||
*1 The included AC cable has power rating of 125 V for use in Japan. | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
GL-SA20F |
|||
Type |
Protection cover Flat type for 20 beam axes |
|||
Overview |
This protective case protects the main unit from impacts. |
|||
Applicable product |
GL-S20FH |
|||
Number included |
1 |
|||
Length |
422.6 mm 16.64" |
|||
Material |
aluminum |
|||
Note |
2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm). |
|||
Weight |
140 g |
|||

Specifications
Model |
KV-XCM02 |
|||
General specifications |
Power voltage |
System configuration using a KV-5000/3000 Series expansion unit: 24 VDC (±10%) |
||
Operating ambient temperature |
System configuration using a KV-5000/3000 Series expansion unit: 0 to +50°C 32 to 122°F (No freezing) |
|||
Operating ambient humidity |
System configuration using a KV-5000/3000 Series expansion unit: 10 to 95% RH (No condensation) |
|||
Storage ambient temperature |
System configuration using a KV-5000/3000 Series expansion unit: −20 to +70°C -4 to +158°F |
|||
Storage relative humidity |
System configuration using a KV-5000/3000 Series expansion unit: 10 to 95% RH (No condensation) |
|||
Operating environment |
No dust or corrosive gas |
|||
Operating altitude |
2000 m 6561.7' or less |
|||
Noise immunity |
1500 Vp-p or more; Pulse duration: 1 μs, 50 ns (based on noise simulator); IEC standard-compliant (IEC 61000-4-2/3/4/6) |
|||
Withstand voltage |
1500 VAC for one minute (between the power terminals and the I/O terminals, and between the external terminals and the case) |
|||
Insulation resistance |
50 MΩ or more (between the power terminals and the I/O terminals and between the external terminals and the case, with 500 VDC megohmmeter) |
|||
Vibration resistance |
Intermittent vibration |
Frequency 5 to 9 Hz |
Half amplitude 3.5 mm 0.14"*4 |
|
Frequency 9 to 150 Hz |
Acceleration 9.8 m/s2 32.2'/s2*4 |
|||
Continuous vibration |
Frequency 5 to 9 Hz |
Half amplitude 1.75 mm 0.07"*4 |
||
Frequency 9 to 150 Hz |
Acceleration 4.9 m/s2 16.1'/s2*4 |
|||
Shock resistance |
Acceleration: 150 m/s2 492.1'/s2, Application time: 11 ms, 2 times in each of the X, Y, and Z directions |
|||
Pollution degree |
2 |
|||
Common specifications |
Connectable CPU unit |
KV-X Series/KV-8000A |
||
Max. number of connectable units |
14 |
|||
Connection interface |
RJ-45 8-position modular connector × 2 ports |
|||
Transmission rate |
10BASE-T: 10 Mbps |
|||
Transmission media |
10BASE-T: Category 3 or higher UTP or STP (STP is recommended) |
|||
Maximum cable length |
100 m 328.1'*7 |
|||
Maximum number of connectable hubs |
10BASE-T: 4 |
|||
Ethernet functions |
Socket communication, FTP server, FTP client, upper link communication, etc. |
|||
Internal current consumption |
200 mA or less |
|||
Weight |
Approx. 190 g 6.71 oz |
|||
Compatibility specifications |
Supported databases |
Microsoft SQL Server, PostgreSQL, MariaDB, MySQL, Oracle Database*9 |
||
Maximum number of connections |
4 |
|||
Supported SQL |
INSERT*10, UPDATE, SELECT*10, DELETE, TRUNCATE, Stored procedure/Stored function execution |
|||
Maximum number of supported columns |
1024 (Microsoft SQL Server); 1000 (PostgreSQL, MariaDB, MySQL, Oracle Database) |
|||
Maximum record storage size |
200000 bytes*11 |
|||
Buffer retransmission function |
Function that buffers SQL statements if communication fails to enable retransmission when communication is restored Maximum buffer capacity: 1 GB per connection (SD card required) |
|||
*1 Supplied via the CPU unit or expansion unit. | ||||




Specifications
Model |
OP-88906 |
|||
Female |
M12 4-pin straight |
|||
Male | ||||
Length |
5 m 16.4' |
|||
Material |
cable: PVC |
|||

Specifications
Model |
FD-EPH8 |
|||
Pipe size |
Outer diameter of pipe |
ø8 0.31" *1 |
||
Compatible outer diameter range |
Polyurethane |
8.0 ±0.1 mm |
||
Nylon |
8.0 ±0.08 mm |
|||
Pipe materials |
Resin pipe connectible to a one-touch coupling |
|||
Supported gases |
Air, nitrogen, argon, and non-corrosive gases*2 |
|||
Supported gas temperature |
−10°C to +60°C 14 to 140°F |
|||
Pressure resistance |
1 MPa |
|||
Flow rate detection principle |
Ultrasonic transmission time difference method |
|||
Flow rate specifications |
Rated flow rate |
(volume flow rate) |
100 L/min 3.53 CFM |
|
(20°C 68°F, atmospheric pressure conversion) * Initial display |
Gas at 20°C 68°F, 0.0 MPa |
|||
Gas at 20°C 68°F, 0.2 MPa |
300 L/min 10.59 CFM |
|||
Gas at 20°C 68°F, 0.4 MPa |
500 L/min 17.7 CFM |
|||
Gas at 20°C 68°F, 0.6 MPa |
700 L/min 24.7 CFM |
|||
Measurement accuracy |
±(2.0% of RD+1.0% of F.S.)*3*4 |
|||
Repeatability |
Response time of 250 ms: ±2.5% of F.S.*3*5 |
|||
Pressure specifications |
Rated pressure |
−100 kPa to +0.75 MPa * However, the flow rate cannot be measured in the range of −100 to −50 kPa. |
||
Overall accuracy |
±2.0% of F.S.*3 |
|||
Repeatability |
Response time of 2.5 ms: ±0.4% of F.S. |
|||
Display resolution |
Instantaneous flow |
0.01/0.1 L/min |
||
Accumulated flow |
0.01/0.1/1/10/100 L |
|||
Pressure |
0.1/1 kPa |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529) |
||
Ambient temperature |
−10°C to +60°C 14 to 140°F (no freezing) |
|||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral concentration: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Sensor unit (parts that do not contact the gas) |
PBT/PAR/iron/Brass electroless nickel plating/POM/NBR/stainless steel/aluminum |
||
Flow channel (parts that contact the gas) |
PBT/Brass electroless nickel plating/NBR/nylon |
|||
Weight |
Approx. 145 g 5.11 oz |
|||
*1 To ensure stable detection, it is recommended to use a pipe inner diameter that is at least equivalent to the inner diameter of this product. | ||||

Specifications
Model |
MU-CB6 |
|||
Type |
Power cable |
|||
Applicable product |
MU-N Series |
|||
Cable end |
Cable end: 6-core loose wires, Controller side: Connector |
|||
Length |
2 m 6.56' |
|||
Material |
PVC (Polyvinyl chloride) |
|||
Note |
Expansion unit |
|||
Weight |
Approx. 130 g |
|||

Specifications
Model |
GL-SP2N1 |
|||
Type |
One-line systemdedicated cable |
|||
Applicable product |
GL-S Series main unit |
|||
Number included |
1 |
|||
Cable end |
Main unit connection connector - Loose wires |
|||
Output |
NPN |
|||
Number of core |
6 |
|||
Length |
2 m 6.56' |
|||
Weight |
60 g |
|||

Specifications
Model |
ER-NH035F |
|||
Cable |
Standard |
|||
Stable detection range |
0 to 1 mm |
|||
Maximum operating distance |
3 mm 0.12" *1 *3 |
|||
Hysteresis distance |
Adjustable |
|||
Repeatability |
1 μm 0.04 Mil *1 *4 |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
5 × 5 mm |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F) |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-10 to +60°C 14°F to 140°F (no freezing) |
|||
Relative humidity |
Up to 85% RH (No condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Detection surface |
Epoxy resin |
||
Case |
SUS304 |
|||
Cable |
PVC |
|||
Sensor head connector |
PA66, polycarbonate |
|||
Accessories |
M2 screw/nut/spring washer/ |
|||
Accessories |
M2 screw/nut/ |
|||
Weight |
Approx. 40 g |
|||
*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object. | ||||

Specifications
Model |
SJ-E084H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
900 mm 35.43"*3 |
|||
Total length |
800 mm 31.50" |
|||
No. ofelectrodes |
25 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1100 g 38.80oz |
|||
*1 Measured under the following conditions. | ||||