Machine Vision Systems

5768 products

Showing 1009 - 1032 of 5768 products

Showing 1009 - 1032 of 5768 products
View
Keyence New Stock Image
Keyence AT-005VH Keyence
Sale price 10,363.00 kr
Only 4 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence GL-R64H Keyence
Sale price 13,126.00 kr
In stock, 16 units

Specifications

Model

GL-R64H

Detection capability

ø0.98" ø25 mm

Total length

50.39" 1280mm

No. of beam

64

Detection height

49.61" 1260mm

Protection height

51.38" 1305mm

Beam axis spacing/Lens diameter

20 mm / ø5 0.79" / ø0.20"

Detecting distance

0.66 to 49.21' 0.2 to 15 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

11.3

OFF→ON

55.8*2

All blocked→ON

82.1*3

Optical synchronization system
(Channel A or B)

ON→OFF

16.4

OFF→ON

63.4*2

All blocked→ON

102.5*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

73

Receiver

83

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

1780 g

Receiver

1790 g

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

keyence Stock Image
Keyence OP-87337 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-87337

Overview

Specialised stand for securing the macro lens to the equipment.

Applicable product

CA-LM0210, CA-LML0210

Weight

Approx. 980 g

keyence Stock Image
Keyence KV-CA1W Keyence
Sale price 24,576.00 kr
Only 3 units left

Specifications

Model

KV-CA1W

General specifications

Vibration resistance

10 to 500 Hz; Power spectral density:
0.033 G2/Hz; X, Y, and Z directions

Operating ambient temperature

0 to +50°C 32 to 122°F (No freezing)

Operating ambient humidity

35 to 85% RH (No condensation)

Storage ambient temperature

−20 to +60°C -4 to +140°F (No freezing)

Storage relative humidity

35 to 85% RH (No condensation)

Enclosure rating

IP65F*1*2

Pollution degree

3

Performance specifications

Installation distance

100 mm 3.94" to ∞

Focal distance

1.05 mm 0.04" (fixed)

Field of view

Horizontal field of view: Approx. 180°
Vertical field of view: Approx. 150°

Image-receiving element

1/2.9-inch color CMOS

Resolution

1280 (H) × 960 (V)

Frame rate

10/30 fps

Internal current consumption

70 mA or less *3

Weight

Approx. 140 g 4.94 oz

*1 The enclosure rating is evaluated with the camera cable connected.
*2 “F” signifies evaluation as oilproof per JIS C 0920.
*3 Maximum current consumption inside the camera when the power supplied to the CPU unit is 24 VDC (−15%/+20%). The maximum current consumption inside the camera is 120 mA when the unit power supplied to the camera is 12 to 24 VDC (−10%/+20%).

keyence Stock Image
Keyence FD-ECH8 Keyence
Sale price 9,326.00 kr
Only 3 units left

Specifications

Model

FD-ECH8

Pipe size

Outer diameter of pipe

ø8 0.31"

Installable range

8.0 0.31"
± 0.15 mm 0.01"

Pipe materials

Polyurethane, nylon, PFA,*1 other*2

Supported gases

Air, nitrogen, argon, and other gases*3

Supported gas temperature

−10°C to +60°C 14 to 140°F

Operating pressure range

0 to 0.75 MPa (upper limit depends on pipe specifications)

Flow rate detection principle

Ultrasonic transmission time difference method

Rated flow rate

(volume flow rate)

70 L/min 2.47 CFM * Initial display

(20°C 68°F, atmospheric pressure conversion)

Gas at 20°C 68°F, 0.2 MPa

210 L/min
7.41 CFM

Gas at 20°C 68°F, 0.4 MPa

350 L/min
12.36 CFM

Gas at 20°C 68°F, 0.6 MPa

490 L/min
17.3 CFM

Repeatability

Response time 250 ms: ±2.5% of F.S.*4*5

Display resolution

Instantaneous flow

0.01/0.1/1 L/min

Accumulated flow

0.01/0.1/1/10/100 L

Display method

Output indicator

Environmental resistance

Enclosure rating

IP65 (IEC60529)

Ambient temperature

−10°C to +60°C 14 to 140°F (no freezing)

Relative humidity

35%RH to 85%RH (no condensation)

Vibration resistance

10 to 500 Hz, power spectral concentration: 0.816 G2/Hz, XYZ axes

Shock resistance

100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis

Material

Sensor unit

PBT/PAR/iron

Sensor surface

Special rubber

Weight

Approx. 105 g
3.70 oz

*1 Use PFA tubes in an environment with a temperature of 40°C 104°F or less.
*2 Resin tubes that transmit ultrasonic waves.
*3 Gases that transmit ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.
*4 Accuracy improves with longer response times. As a rule, this is by a proportion of √(250 ms/response time)x.
*5 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the condition and type of pipes as well as the temperature and type of gas.

Keyence Stock Image
Keyence OP-87773 Keyence
Sale price 1,421.00 kr
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence FD-GD150U Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

FD-GD150U

Pipe size/Outer diameter

6" (150 A) ø163 to ø171 mm ø6.42" to ø6.73"

Weight

Approx. 0.77 kg

keyence Stock Image
Keyence OP-89072 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence FD-H47F Keyence
Sale price 15,751.00 kr
Only 2 units left

Specifications

Model

FD-H47F

Type

Hose model

Supported pipe diameter

ø33–47.9 ø1.299"-1.886"

Supported pipe materials

Soft plastic piping, all hoses (braided hoses, pressure-resistant rubber hoses, etc.)*1

Supported fluids

All fluids (water, oil, chemicals, etc.)*1

Supported fluid temperature

0–100°C 32–212°F (no freezing on pipe surface)*2

Maximum rated flow

300 L/min
79.3 gal/min

Zero cut flow rate

2.0 L/min
0.5 gal/min (variable, initial value)

Detection principle

Delta TOF

Function for automatic correction for speed of sound in liquid

Display

QVGA 2.0 model: color LCD, status indicator light

Display update cycle

Approx. 10 times/second

Display resolution

Instantaneous flow

0.01/0.1/1 (L/min) (default value: 1)

Integrated flow

0.01/0.1/1 (L) (default value: 1; up to 8 digits)

Response time

0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s

Measurement accuracy

Repeatability

0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*4

Hysteresis

Variable

Flow units

L/min m3/h G/min

Pulse output increments (L)

0.02–999.99

Pipe temperature measurement accuracy

Network support

IO-Link*5

Heat calculation function

Unit

MJ/h kW kBTU/h*6

Display resolution

Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*6

Pulse output increments (MJ)

0.02–999.99*6

Data accumulation

Accumulation period

Approx. 1 year

Data reading

USB2.0

Power I/O connector

M12 8-pin connector (male)

I/O (switchable)

Output (Ch1/2/3/4)

Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output
NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less

Analog output (Ch1/2)

4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less

External input (Ch2/3)

Integrated reset input / flow-rate zero input / zero-point adjustment input / bank input
Short circuit current: 1.5 mA or less; input time: 20 ms or more

Power supply

Power voltage

20–30 VDC, ripple (P-P) 10% included, Class 2/LPS

Current consumption

240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*7

Protection circuit

Protection against reverse power connection, power supply surges, output short circuits, and output surges

Environmental resistance

Enclosure rating

IP65/67 (IEC 60529)*8

Ambient temperature

Sensor head: −20 to +60°C –4 to +140°F (no freezing); Display unit: −20 to +50°C –4 to +122°F (no freezing)*2

Relative humidity

35–85% RH (no condensation)

Vibration resistance

10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes

Material

Display unit

Body: PPS/PET/POM; Display window: PAR

Sensor head

Body: PPS/PET/PAR/SUS304; Cable: PVC
Sensor element: special rubber; Mounting bracket: PPS/PBT/POM/SUS304/SUSXM7

Weight

approx. 1130 g 39.86 oz

*1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe.
*2 When the display unit is mounted directly on the sensor head, there is a de-rating according to the ambient temperature and fluid temperature.
*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes, the type of fluid, the fluid temperature and other factors.
*4 In a state where flow velocity distribution is stable. Does not include pulsation and fluctuations in flow velocity distribution due to equipment factors. Please also convert the given F.S. (full scale) using the rated flow range.
*5 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*6 Can be used when two temperature sensors (sold separately) are connected.
*7 640 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (up to a maximum of 830 mA or less).
*8 When a USB connection is in use, IP65/67 compliance is impaired.

Keyence Stock Image
Keyence CA-DBW34H Keyence
Sale price 21,541.00 kr
Only 3 units left

Specifications

Model

CA-DBW34H

Type

High-Intensity, Large Bar Light

LED color

White

Diffusion plate

A diffusion plate is included with the CA-DBWxxH. The thickness of the diffusion plate is approximately 2 mm 0.08".

Power consumption

18.4 W × 2 ch*1*2

Input voltage

12 VDC

Polarizing diffusion plate

OP-87977*3

Weight

Approx. 1,050 g

*1 Connect these models to both channels.
*2 A diffusion plate is included with the CA-DBWxxH. The thickness of the diffusion plate is approximately 2 mm 0.08".
*3 The included diffusion plate and polarizing diffusion plate cannot be used with the product at the same time.
There may be air bubbles or foreign substances on the surface of the polarizing diffusion plate, but these have no effect on the image quality. Even if such substances are present, the product is still within the inspection standards, and these substances do not indicate that the product is defective.

keyence Stock Image
Keyence CL-AC2 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-AC2

Length

2 m 6.6'

Weight

400 g

Keyence Stock Image
Keyence CV-X300E Keyence
Sale price 24,075.00 kr
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence OP-87528 Keyence
Sale price 2,060.00 kr
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88900 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-88900

Female

M12 8pin L-shape

Male

Strand wire

Length

2 m 6.6'

Material

cable: Chemicalresistant PVC
connector: PBT

keyence Stock Image
Keyence OP-89087 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence LX2-11WT Keyence
Sale price 8,046.00 kr
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence FL-P20 Keyence
Sale price 4,376.00 kr
Only 5 units left

Specifications

Model

FL-P20

Probe length

200*1

Measurement range (dead zone excluded)

165 (120)*2

Weight

Approx. 75 g

*1 Total length including the projected areas of the sensor refer to External Dimension Diagrams for details. Can be shortened up to 100 mm 3.93".
*2 If the probe is shortened

keyence Stock Image
Keyence BT-GN6 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

BT-GN6

Type

Gun Grip Attachment

Weight

Approx. 600 g 21.18 oz
(With Main Unit + Battery)

Keyence Stock Image
Keyence LV-21 Keyence
Sale price 4,989.00 kr
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence GL-VB32 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GL-VB32

Number included

2

Material

SUS304, NBR

Weight

160 g 5.64 oz *1

*1 GL-V Mounting includes two mounting brackets. The weight stated is for both items.

keyence Stock Image
Keyence CA-DZW45D Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CA-DZW45D*1

Type

Diffuse Line Lights

LED color

White

Power consumption

19.8 W × 2 ch*2

Input voltage

12 VDC

Weight

620 g

*1 The diffusion plate is integrated into the light and is not removable.
When using a line scan camera, use DC Mode on the CA-DC21E/DC40E.
*2 Connect this model to both channels.

keyence Stock Image
Keyence FR-LEXB43 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

FR-LEXB43

Type

Zener barrier with explosion-proof box

Input/Output

2-wire system

Explosion-Proof Specifications

AEx db [ia Ga]
IIB T4 Gb
AEx tb [ia Da]
IIIC T135°C Db

keyence Stock Image
Keyence OP-84338 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-84338

Overview

Connection connector to a display unit. Needed when cutting the cable.

Applicable product

GT2

Number included

2 pcs.

Note

Adjustable cable diameter: 1.15 to 1.35mm (Cable external diameter)

Keyence Stock Image
Keyence CA-DRM5X Keyence
Sale price 7,137.00 kr
In stock, 12 units

Specifications

Model

CA-DRM5X

Type

Multi-Spectrum Lighting

Illumination method

Ring illumination (with support for optional CA-DRM (DA) Series dome attachment and CA-DRM (PA) Series polarization attachment*1)
Multi-Spectrum lighting / LumiTrax lighting / Normal lighting (single-color lighting in all directions)*2
Constant current control mode (1,024-step digital gradation: With CA-DC60E connected / Adjustable per wavelength*3)

Response speed

1 ms or less

LED

Peak wavelength

Ultraviolet: 405 nm / Blue: 457 nm / Green: 527 nm / Orange: 600 nm / Red: 660 nm
Far red: 730 nm / Infrared: 860 nm / White: 600 nm (All values approximate)

Controller connection

Dedicated cable (3 m 9.8' / 5 m 16.4' / 10 m 32.8'), Max. 30 m 98.4' (with extension cables*4)

I/F input

12-pole connector (dedicated cable)

Power consumption

51.4 W (during normal light emission)

Environmental resistance

Ambient temperature

0 to 40 °C 32 to 104 °F

Relative humidity

65%RH or less (No condensation)

Weight

Approx. 560 g (With dome attachment: Approx. 680 g/With polarization attachment: Approx. 690 g)

*1 The UV and IR wavelengths cannot be used when the polarization attachment is attached.
*2 Continuous lighting can only be set during normal lighting when brightness value control is set to ON.
*3 Simultaneous lighting of multiple colors is not supported.
*4 Connection of up to two dedicated extension cables is allowed.

Recently viewed