Specifications
Model |
PX-H61G*1 |
|||
Type |
M12 Reflective Armored |
|||
Light source LED |
Red 4-element LED |
|||
Detecting distance |
TURBO |
400 mm 15.7" |
||
SUPER |
600 mm 23.6" |
|||
ULTRA |
1200 mm 47.2" |
|||
MEGA |
2000 mm 78.7" |
|||
Detectable object |
― |
|||
Spot diameter |
Approx. 15 x 15 mm 0.59" |
|||
Environmental resistance |
Enclosure rating |
IEC: IP68/JEM: IP68g/NEMA: 4X, 6P, 13/DIN: IP69K |
||
Ambient light |
Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max. |
|||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Case material |
Housing :SUS303 (Plastic parts:PMP, POM) Lens :BK7 |
|||
Accessories |
Screw nut x 2, |
|||
Weight |
Approx. 220 g*2 (Including cable) |
|||
*1 Contact KEYENCE for cable length variations of spiral types. | ||||


Specifications
Model |
CA-DXB5 |
|||
Type |
Coaxial Light (On-Axis) |
|||
LED color |
Blue |
|||
Power consumption |
4.9 W |
|||
Input voltage |
12 VDC |
|||
Weight |
Approx. 230 g |
|||

Specifications
Model |
EX-V01E |
|||
Type |
Controller |
|||
Shape |
ø5.4 x 18 mm ø0.21" x 0.71" Cylindrical |
|||
Measuring range |
0 to 1 mm 0.04" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
0.4 µm 0.016 Mil |
|||
Sampling rate |
40,000 samplings max./sec. *1 |
|||
Display speed |
20 times/sec. (2-color, 7-segment LED) |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
Timing input |
NPN open-collector or non-voltage contact signal |
||
Reset input | ||||
Auto-zero input | ||||
Judgment output: Inhibit input | ||||
Synchronization/external settings input | ||||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms (ON/OFF selectable) |
|||
Strobe output |
NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *2 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
240 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 235 g |
|||
*1 When the digital filter function is used, the sampling rate is 20,000 sampling/sec. | ||||

Specifications
Model |
PG-610 |
|||
Type |
Amplifier |
|||
Detecting area |
21 x 21 mm 0.83" x 0.83" |
|||
Minimum detectable object |
0.5 mm 0.02" dia. min. opaque materials |
|||
Light source |
Infrared LED |
|||
Sensitivity adjustment |
1-turn trimmer |
|||
Indicator lamp |
Output: Red LED, Stable operation: Green LED |
|||
Output |
Control output |
NPN: 100 mA max. (40 V max.) Residual voltage: 1 V max.*1 |
||
Self-diagnostic output |
NPN: 100 mA max. (40 V max.) Residual voltage: 1 V max.*2 |
|||
Response time |
0.2 ms*2 |
|||
Off-delay time |
0.5 / 70 ms (selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
40 mA or less |
|||
Environmental resistance |
Ambient light |
Fluorescent lamp: 10,000 lux max., Sunlight: 1,500 lux max. |
||
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Amplifier (including 3-m 9.8' cable): Approx. 100 g |
|||
*1 NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP Output Converter. One-shot output (ON when target passes through sensor) | ||||

Specifications
Model |
OP-87583 |
|||
Cable end |
M12 straight - Loose wire |
|||
Length |
5 m 16.40' |
|||
Material |
Covering: PUR, Nut: Nickel plating over zinc die-cast |
|||


Specifications
Model |
FU-A05D*1 |
|||
Type |
Array reflective model |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø2.2 |
|||
Minimum bend radius |
R4 mm0.157"*2 |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *3 |
|||
Tightening torque |
0.3 Nm |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-40 to +70 °C -40 to 158 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Main unit case : polybutylene terephthalate, case tips : liquid-crystal polymer, core fiber : acrylic, fiber sheath : polyethylene |
|||
Accessories |
Mounting screws (M3 × ℓ8), fiber cutter |
|||
Weight |
Approx. 20 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
GL-RC20S |
|||
Type |
Extension Cable |
|||
Applicable product |
GL-R Series |
|||
Number included |
1 cable |
|||
Cable end |
M12 connector (8-pin female) - Loose wires |
|||
Length |
20 m 65.62' |
|||
Material |
Connector for extension: PVC/nickel-plated brass, Cable: PVC |
|||
Note |
Extension cable for the GL-R Series. Use this together with the main unit connection cable (for extension). |
|||
Weight |
Approx. 830 g |
|||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-R7F*1 |
|||
Type |
Threaded and Hex-Shaped Active Receiver Fibers |
|||
Optical axis diameter |
Transmitter: ø 1ø 0.04" Receiver: ø 3.2ø 0.13" |
|||
Size |
M4 |
|||
Fibre unit length |
2 m6.6'Free-cut |
|||
Fibre unit diameter |
ø 2.2ø 0.09" |
|||
Shape |
Threaded |
|||
Minimum bend radius |
R25 mmR0.98" |
|||
Environmental resistance |
Ambient temperature |
−40 to +60 ˚C -40 to +140 °F |
||
Weight |
Approx. 21 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FD-XC20M2 |
|||
Supported diameter |
Attachable range: ø 10.8 to 14 mm 0.43 " to 0.55 " |
|||
Weight |
Approx. 250 g |
|||


Specifications
Model |
KV-B8XTD |
|||
Type |
I/O unit |
|||
External connection method |
Removable terminal block |
|||
Input |
Number of inputs |
8 points |
||
Input mode |
24 VDC mode, 5 VDC mode |
|||
Maximum input voltage |
26.4 VDC |
|||
Rated input voltage |
24 VDC mode:24 VDC, 5.3 mA , 5 VDC mode: 5 VDC, 1 mA |
|||
Minimum ON voltage |
24 VDC mode:19 V , 5 VDC mode: 3.5 V |
|||
Maximum OFF current |
24 VDC mode: 1.5 mA |
|||
Maximum OFF voltage |
5 VDC mode: 1.5 V |
|||
Common method |
8 points/1 common (1 terminal) |
|||
Input time constant |
25 μs/300 μs*1/1 ms/10 ms |
|||
Input impedance |
4.3 kΩ |
|||
Output |
Number of outputs |
8 points |
||
Output mode |
MOSFET (sink) (with overcurrent protection function) |
|||
Rated load |
30 VDC, 0.3 A |
|||
Leakage current at OFF |
100 μA or less |
|||
Residual voltage at ON |
0.5 VDC or less |
|||
Common method |
8 points/1 common (1 terminal) |
|||
Operation time |
OFF to ON:100 μs or less ,ON to OFF: 300 μs or less |
|||
Internal current consumption |
30 mA or less |
|||
Weight |
Approx. 130 g |
|||
*1 Configurable only when KV-8000A/7500/7300/5500/5000/3000 is connected. Cannot be selected when connected to KV-1000/700. | ||||


Specifications
Model |
CA-LM2*1 |
|||
Type |
Standard |
|||
Optical magnification (reference magnification) |
x2 |
|||
Magnification range |
Approx. ±3 % relative to reference axis |
|||
WD (at reference magnification) |
66.9 mm 2.63" *2 |
|||
Compatible image sensor size |
1/2" |
|||
Field of view (at reference magnification) |
1/3" |
1.8 x 2.4 mm 0.071" x 0.094" |
||
1/2" |
2.4 x 3.2 mm 0.094" x 0.126" |
|||
2/3" |
- |
|||
F-stop range (aperture) |
15.4 |
|||
Depth-of-field |
400 µm 15.75 Mil*3 |
|||
Max. TV distortion |
-0.04 % |
|||
Resolution |
5.1 µm 0.20 Mil*4 |
|||
Mount |
C-mount |
|||
Ambient temperature/humidity range |
0 to +50 °C 32 to 122 °F, 80 % RH (No condensation) |
|||
Weight |
Approx. 57 g |
|||
*1 The above values are all calculated according to optical design values. Actual values for individual lenses will differ according to precision of assembly. | ||||

Specifications
Model |
OP-26501 |
|||
Type |
Adapter B for f1 Fiber Unit |
|||
Applicable product |
ø1.0 fiber unit |
|||
Number included |
1 pcs. |
|||
Note |
Necessary when small diameter fiber unit is used with FS-N/V/T/M Series. |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.