Specifications
Model |
FU-78*1 |
|||
Detecting method |
Thrubeam |
|||
Optical axis diameter |
ø1 mm 0.04" |
|||
Size |
M4 |
|||
Fibre unit length |
2 m 6.56', Free-cut |
|||
Fibre unit diameter |
ø1.3 ø0.05" |
|||
Shape |
Threaded |
|||
Minimum bend radius |
R4 mm R0.16" |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 9 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
NR-FV04 *1 |
|||
Type |
Pulse measurement unit |
|||
Input method |
Insulated single-end input, channels insulated from each other, input channels insulated from other units (PC) |
|||
Number of channels |
4 ch *2 |
|||
Measurement cycle |
Maximum sampling cycle: 1 μs (1 MHz) to 60 s |
|||
A/D converting system |
Successive approximation, simultaneous sampling of all channels |
|||
A/D resolution |
14 bit |
|||
Input frequency band |
250 kHz (−3 dB or more) |
|||
Low pass filter |
PASS, 1.5 kHz, 15 kHz, 50 kHz |
|||
Pulse input |
Input type |
Pulse frequency, pulse count (Single-phase input) |
||
Maximum input voltage |
±700 V *3 |
|||
Threshold voltage |
+100 V, +50 V, +20 V, +10 V, +5 V, +2.5 V, +1 V, +500 mV, +250 mV, +100 mV, +50 mV, 0 V |
|||
Minimum pulse duration |
2 μs or more for both ON and OFF |
|||
Hysteresis |
AUTO, 100 mV, 500 mV, 5 V |
|||
Pulse divisions |
1 to 64 (Can be set to units of 1 division) |
|||
Input coupling |
DC rising edge, DC falling edge, AC rising edge, AC falling edge |
|||
Digital filter |
Pulse frequency: Averaging rate of 1 to 32768 (automatically selected), Pulse count: None |
|||
Predictive functions |
Predictive calculation, Stop prediction (OFF, ×1.5, ×3, ×5, ×8, ×16) |
|||
Sensor power output |
Dedicated connectors for OP-88003 (AUX POWER) × 2 when using OP-88003; +12 V, 50 mA or +5 V, 50 mA |
|||
Voltage input |
Input type |
±100 V, ±50 V, ±20 V, ±10 V, ±5 V, ±2 V |
||
Maximum input voltage |
±700 V *3 |
|||
Digital filter |
Averaging rate: 1 to 128 (automatically selected) |
|||
Input coupling |
DC, AC |
|||
Common mode noise reduction ratio |
80 dB or more (at up to 60 Hz DC) |
|||
Residual noise level |
0.02% of F.S., LPF: 1.5 kHz (200 μs/S, digital filter: ON); 0.05% of F.S., LPF: PASS |
|||
Measurement range |
Pulse frequency |
Measurable range: 0.05 to 16000.00 Hz, Display resolution: 0.01 to 1.00 Hz (selected automatically according to frequency) |
||
Pulse count |
Measurable range: 0 to 65,000 counts/sampling cycle, Display resolution: 1 count |
|||
±100 V |
Measurable range: −110.000 to +110.000 V, Display resolution: 5 mV |
|||
±50 V |
Measurable range: −55.000 to +55.000 V, Display resolution: 2 mV |
|||
±20 V |
Measurable range: −22.000 to +22.000 V, Display resolution: 1 mV |
|||
±10 V |
Measurable range: −11.0000 to +11.0000 V, Display resolution: 0.5 mV |
|||
±5 V |
Measurable range: −5.5000 to +5.5000 V, Display resolution: 0.2 mV |
|||
±2 V |
Measurable range: −2.2000 to +2.2000 V, Display resolution: 0.1 mV |
|||
Measurement accuracy |
Pulse frequency |
±0.07% of rdg, ±0.01 Hz (20 Hz to 15 kHz, 20 ms/S, with digital filter ON) |
||
Voltage input |
±0.1% of F.S., LPF: 500 Hz, with digital filter ON |
|||
Withstand voltage |
Input to system bus/earth |
2200 VAC (50/60 Hz) for 1 minute |
||
Connector format |
Insulated BNC connector |
|||
Input impedance |
1 MΩ ±1%, approx. 30 pF |
|||
Buffer memory |
16M data*4 |
|||
Warm up time |
30 minutes or more |
|||
Maximum allowable voltage to ground |
[When using OP-89263 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II); |
|||
Rating |
Power consumption |
4 W or less (including OP-88003 sensor power supply) |
||
Environmental resistance |
Insulation resistance |
500 VDC, 10 MΩ or more |
||
Ambient temperature |
0 to +40°C 32°F to 104°F |
|||
Relative humidity |
10 to 85% RH (no condensation) |
|||
Weight |
Approx. 270 g 9.53 oz |
|||
*1 The above specifications are the values when zero point adjustment is performed after the warm-up period in an environment with a temperature of 23°C ±3°C 73.4°F ±5.4°F. | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-40G*1 |
|||
Beam emitting direction |
Top |
|||
Aperture angle |
Approx 8° |
|||
Fibre unit length |
1 m39.37" cannot be cut |
|||
Minimum bend radius |
R10 mm0.394" , stainless |
|||
Environmental resistance |
Ambient temperature |
-40 to +50 °C -40 to 122 °F |
||
Weight |
Approx. 50 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||


Specifications
Model |
RC2-22K |
|||
Operation method |
Addition, subtraction, addition and subtraction |
|||
Operation mode |
Overcount, auto reset, rotary, range distinction |
|||
Return method |
Manual reset, external reset, automatic reset (in auto reset mode) |
|||
Display power |
7-segment LED (character height: 14 mm) |
|||
Number of digits |
5-digit display (zero suppression method), -9,999 to 99,999*1 |
|||
Prescale function |
A |
1 to 99 is counted per pulse input |
||
B |
1 is counted per 1 to 99,999 pulse inputs |
|||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Input |
System |
Separate, instruction, phase difference |
||
Mounting method |
Panel mount (embedding) |
|||
External calibration input signal |
Signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
||
Highest counting speed |
With contacts: 50 Hz, without contacts: 500 Hz, 5 kHz, 50 kHz (switchable; 1:1 ON:OFF ratio) |
|||
Control output |
One-shot output time |
0.01 s to 9.99 s (variable) |
||
Relay |
Open-collector output: 10 ms (when set to 50 Hz), 1 ms (when set to 500 Hz), 100 µs (when set to 5 kHz), 15 µs (when set to 50 kHz) |
|||
DC output |
12 VDC ± 10%, 100 mA maximum |
|||
Rating |
Power voltage |
100 to 240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
12VA or less |
|||
Environmental resistance |
Insulation resistance |
100 MΩ or more (tested with a 500 VDC megger) between all the AC external terminals and the case |
||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 1 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Withstand voltage |
500 VAC for 1 minute (between all the external terminals and the case) |
|||
Weight |
Approx. 320 g |
|||
*1 Display uses the zero suppression method. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FD-HCB10G |
|||
Cable end |
M12, 8-pin female - 6-core cable |
|||
Length |
10 m 32.8' |
|||
Material |
PVC |
|||
Weight |
Approx. 420 g |
|||




Specifications
Model |
SZ-VP30 |
|||
Type |
18-core Power cable |
|||
Applicable product |
SZ-V Series |
|||
Cable end |
Connector (connected to the SZ-V) - Loose wires |
|||
Length |
30 m 98.42' |
|||
Material |
PVC |
|||
Weight |
Approx. 2,200 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SV2-B005AS |
|||
General specifications |
Applicable servo amplifier |
SV2-005L2 |
||
Rated output |
50 W |
|||
Rated torque |
0.159 N·m *1 |
|||
Instant maximum torque |
0.557 N·m |
|||
Rated current |
0.55 Arms |
|||
Instant maximum current |
2.0 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.316 N·m/Arms |
|||
Rotor moment of inertia |
0.0475 ×10-4kg·m2 |
|||
Rated power rating |
6.40 kW/s |
|||
Rated angle acceleration |
40200 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
35 × |
|||
Approx. weight |
0.6 kg |
|||
Electromagnetic brake specifications |
Capacity |
5.5 W |
||
Rated voltage |
24 VDC ±10% |
|||
Rated current (@20°C 68°F) |
0.23 A |
|||
Holding torque |
0.159 N·m |
|||
Release time |
60 ms *2 |
|||
Operating time |
100 ms *2 |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
CL-H100 |
|||
Type |
Expansion Unit |
|||
Number of optical unit connections |
Supports two CL-H200 expansion units |
|||
Environmental resistance |
Ambient temperature |
0 to 50°C 32 to 122°F |
||
Relative humidity |
20% RH to 85% RH (no condensation) |
|||
Weight |
Approx. 300 g |
|||

Specifications
Model |
AI-F10H |
|||
Type |
Polarized Light Filter Attachment for Separate amplifier models, Long range |
|||
Applicable product |
AI-H160 |
|||
Note |
Included in sensor head package |
|||

Specifications
Model |
EV-108UC |
|||
Type |
DC , Non-shielded |
|||
Shape |
M8 |
|||
Detecting distance |
4 mm 0.16" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target |
20 x 20 mm 0.79" x 0.79" |
|||
Hysteresis |
20% max. of detecting distance, within -10 to +70°C 14 to 158°F |
|||
Response frequency |
800 Hz |
|||
Operation mode |
N.C. |
|||
Temperature characteristics |
±10% max. of detecting distance, |
|||
Control output |
5 to 80 mA |
|||
Protection circuit |
Reversed polarity,surge voltage |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 20 % or less |
||
Current consumption (leakage |
Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Residual voltage |
Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Stainless steel (SUS304) |
|||
Accessories |
Nut × 2, toothed washer × 1, instruction manual |
|||
Weight |
Approx. 42 g |
|||


Specifications
Model |
ER-U30N |
|||
Type |
Ultra-long distance unshielded type Screw type M30 Cable NPN output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
Available |
|||
Button |
Function |
Distance switching |
||
Detecting distance |
With default settings (Mode 1) |
52 mm 2.05" ±10% *2 |
||
With distance switching (Mode 2) |
32 mm 1.26" ±10% *2 |
|||
Response frequency |
With default settings (Mode 1) |
10 Hz *3 *4 |
||
With distance switching (Mode 2) |
20 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
156 × 156 mm 6.14" × 6.14" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
NPN output: 0.9 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
NPN output: 1040 mW or less (44 mA or less at 24 V, 65 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 190 g 6.71 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
CA-HX200M |
|||
Image element |
Monochrome CMOS image receiving element, 16× high-speed reading using square-pixel, |
|||
Valid pixel count |
1.92 M pixels, 1600 (H) × 1200 (V) |
|||
Image size |
Equivalent to 2/3 " |
|||
Scanning system |
Progressive |
|||
Pixel transfer frequency |
195 MHz (×16 speed) *1 |
|||
Electronic shutter |
Can be set to 0.01 to 100 msec by specifying the following numerical inputs: |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (no condensation) |
|||
Camera cable |
High-speed camera cable CA-CHxx |
|||
Weight |
Approx. 280 g (not including lens) |
|||
*1 When using the CV-X400 or CV-X200 Series with the CA-EC80HX/EC80L | ||||