Main
| Characteristic | Value(s) |
|---|---|
| Range | EVlink |
| product name | EVlink parking |
| Product or component type | Enclosure |
| Device short name | EVP2 |
| Range compatibility | EVlink EVlink parking EVF2 charging station EVlink EVlink parking EVW2 charging station |
| Poles description | 1P + N for control circuit 1P + N for power circuit |
| Mounting mode | Wall-mounted Floor-standing |
| Offer type | Standard |
| rated supply voltage | 230 V AC 50/60 Hz power circuit 220...240 V AC 50/60 Hz control circuit |
| Earthing system | TT TN IT |
| socket-outlet number | 1 |
| socket-outlet type | Right side: T2 with shutter / silver plated contacts |
| Maximum supply current | 32 A for T2 with shutter |
| Max power | 7 kW for T2 with shutter |
| Access control system | Badge RFID conforming to ISO/IEC 14443 Badge RFID conforming to ISO/IEC 15693 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Control type | 1 red push-button, function: stop 1 green illuminated push-button, function: start/unlock flap |
| Local signalling | On charge: 1 LED (green) (flashing) on side Available: 1 LED (green) on front Reserved: 1 LED (orange) on front Not operational: 1 LED (red) on front |
| Web server | Embedded |
| Ethernet service | Configuration via web server |
| Height | 625 mm |
| Width | 400 mm |
| Depth | 206 mm |
| Product weight | 20 kg |
| Colour | Grey (RAL 7016) |

Main
| Characteristic | Value(s) |
|---|---|
| Range | EVlink |
| product name | EVlink parking |
| Product or component type | Charging station |
| Device short name | EVF2 |
| Poles description | 1P + N for control circuit 1P + N for power circuit |
| Mounting mode | Floor-standing |
| Offer type | Standard |
| rated supply voltage | 230 V AC 50/60 Hz power circuit 220...240 V AC 50/60 Hz control circuit |
| Earthing system | TN TT IT |
| socket-outlet number | 1 |
| socket-outlet type | Right: T2 with shutter / silver plated contacts |
| Maximum supply current | 32 A for T2 with shutter |
| Max power | 7 kW for T2 with shutter |
Complementary
| Characteristic | Value(s) |
|---|---|
| Control type | 1 red push-button, function: stop 1 green illuminated push-button, function: start/unlock flap |
| Local signalling | On charge: 1 LED (green) (flashing) on side Available: 1 LED (green) on front Reserved: 1 LED (orange) on front Not operational: 1 LED (red) on front |
| Communication port protocol | OCPP 1.6 |
| Configuration /Architecture | Clustered architecture Standalone |
| Operation and maintenance | Postponed charge Circuit breaker status User privilege configuration Load management Charge detail records Diagnosis capabilities |
| Web server | Embedded |
| Ethernet service | Configuration via web server |
| Standards | IEC 61851-1 IEC 61851-22 |
| Product certifications | CB ZE Ready CE EV Ready |
| Height | 1146 mm |
| Width | 413 mm |
| Depth | 220 mm |
| Product weight | 50 kg |
| Colour | Front: white (RAL 9003) Side: grey (RAL 7016) |

Main
| Characteristic | Value(s) |
|---|---|
| Range | EVlink |
| product name | EVlink Wallbox |
| Product or component type | Charging station |
| Device short name | EVH2 |
| Poles description | 1P + N |
| Mounting mode | Wall-mounted |
| Offer type | Standard |
| Max power | 3.7 kW 16 A |
| Number of charge point | 1 |
| Connection to the vehicle | Attached cable T2 4 m |
| Access control system | Key |
Complementary
| Characteristic | Value(s) |
|---|---|
| rated supply voltage | 220...240 V AC 50/60 Hz |
| Earthing system | TT TN |
| Number of inputs | 1 |
| Input type | Contact for power limitation Contact for delayed charging |
| Control type | 1 white button, function: stop/restart Green button, function: cable unlocking |
| Local signalling | 1 multi-colour LED, function: status indication |
| Height | 480 mm |
| Width | 330 mm |
| Depth | 170 mm |
| Product weight | 7.5 kg |
| Colour | White (RAL 9003) Grey (RAL 7016) |
| Standards | IEC 62196-2 IEC 61851-1 IEC 61851-22 IEC 62196-1 |
| Product certifications | CE CB |

Main
| Characteristic | Value(s) |
|---|---|
| Range | EVlink |
| Product or component type | Front panel |
Complementary
| Characteristic | Value(s) |
|---|---|
| Range compatibility | EVlink EVlink Smart Wallbox charging station EVlink EVlink Wallbox charging station |

Main
| Characteristic | Value(s) |
|---|---|
| Range | EVlink |
| product name | EVlink Wallbox |
| Product or component type | Charging station |
| Device short name | EVH2 |
| Poles description | 1P + N |
| Mounting mode | Wall-mounted |
| Offer type | Standard |
| Max power | 7.4 kW 32 A |
| Number of charge point | 1 |
| Connection to the vehicle | Socket-outlet T2 with shutter |
| Access control system | Key |
Complementary
| Characteristic | Value(s) |
|---|---|
| rated supply voltage | 220...240 V AC 50/60 Hz |
| Earthing system | TT TN |
| Number of inputs | 1 |
| Input type | Contact for power limitation Contact for delayed charging |
| Control type | 1 white button, function: stop/restart Green button, function: cable unlocking |
| Local signalling | 1 multi-colour LED, function: status indication |
| Height | 480 mm |
| Width | 331.5 mm |
| Depth | 170 mm |
| Product weight | 5.6 kg |
| Colour | White (RAL 9003) Grey (RAL 7016) |
| Standards | IEC 62196-2 IEC 61851-1 IEC 61851-22 IEC 62196-1 |
| Product certifications | CE CB |

Main
| Characteristic | Value(s) |
|---|---|
| Range | EVlink |
| product name | EVlink parking |
| Product or component type | Enclosure |
| Device short name | EVP2 |
| Range compatibility | EVlink EVlink parking EVF2 charging station EVlink EVlink parking EVW2 charging station |
| Poles description | 3P + N for power circuit 1P + N for control circuit |
| Mounting mode | Floor-standing Wall-mounted |
| Offer type | Standard |
| rated supply voltage | 230 V AC 50/60 Hz control circuit 380...415 V AC 50/60 Hz power circuit |
| Earthing system | TT TN IT |
| socket-outlet number | 1 |
| socket-outlet type | Right side: T2 with shutter / silver plated contacts |
| Maximum supply current | 32 A for T2 with shutter |
| Max power | 22 kW for T2 with shutter |
Complementary
| Characteristic | Value(s) |
|---|---|
| Control type | 1 red push-button, function: stop 1 green illuminated push-button, function: start/unlock flap |
| Local signalling | On charge: 1 LED (green) (flashing) on side Available: 1 LED (green) on front Reserved: 1 LED (orange) on front Not operational: 1 LED (red) on front |
| Web server | Embedded |
| Ethernet service | Configuration via web server |
| Height | 625 mm |
| Width | 400 mm |
| Depth | 206 mm |
| Product weight | 20 kg |
| Colour | Grey (RAL 7016) |

This Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 13A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 3kA at 415VAC conforming to EN/IEC 60947-2 standard and 3kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 81mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Multi9 |
| product name | Multi9 C60 |
| Product or Component Type | Miniature circuit-breaker |
| Device short name | C60SP |
| Device Application | Distribution |
| Poles description | 1P |
| Number of protected poles | 1 |
| Line Rated Current | 13 A 77 °F (25 °C) EN/IEC 60947-2 |
| Network type | DC AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | D |
| Breaking capacity | 10 kA AIR 277 V AC UL 1077 14 kA AIR 240 V AC UL 1077 14 kA AIR 120 V AC UL 1077 10 kA AIR 65 V DC UL 1077 10 kA AIR 277 V AC CSA C22.2 No 235 14 kA AIR 240 V AC CSA C22.2 No 235 14 kA AIR 120 V AC CSA C22.2 No 235 10 kA AIR 65 V DC CSA C22.2 No 235 3 kA Icu 415 V AC EN/IEC 60947-2 10 kA Icu 240 V AC EN/IEC 60947-2 20 kA Icu 60 V DC EN/IEC 60947-2 3 kA Icu 415 V AC GB 14048.2 10 kA Icu 240 V AC GB 14048.2 20 kA Icu 60 V DC GB 14048.2 |
| Standards | EN/IEC 60947-2 GB 14048.2 UL 1077 CSA C22.2 No 235 |
| Product certifications | IEC CCC UR CSA |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ue] rated operational voltage | 240 V AC 50/60 Hz 415 V AC 50/60 Hz 60 V DC |
| Magnetic tripping limit | 12 x In +/- 20 % AC 17 x In +/- 20 % DC |
| [Ics] rated service breaking capacity | 2.25 kA 75 % EN/IEC 60947-2 - 415 V AC 7.5 kA 75 % EN/IEC 60947-2 - 240 V AC 20 kA 100 % EN/IEC 60947-2 - 60 V DC 2.25 kA 75 % GB 14048.2 - 415 V AC 7.5 kA 75 % GB 14048.2 - 240 V AC 20 kA 100 % GB 14048.2 - 60 V DC |
| [Ui] rated insulation voltage | 500 V AC EN/IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kVEN/IEC 60947-2 |
| Suitability for isolation | Yes EN/IEC 60947-2 |
| Contact position indicator | Yes |
| Control Type | Toggle |
| Local signalling | ON/OFF indication |
| Mounting Mode | Clip-on |
| Mounting Support | DIN rail |
| 9 mm pitches | 2 |
| Height | 3.2 in (81 mm) |
| Width | 0.7 in (18 mm) |
| Depth | 2.8 in (72 mm) |
| color | Gray |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Provision for padlocking | Padlockable |
| Connections - terminals | Tunnel type terminal top or bottom) 0.002â¦0.04 in² (1â¦25 mm²) AWG 18...AWG 8) - rigid Tunnel type terminal top or bottom) 0.002â¦0.02 in² (1â¦16 mm²) AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal top or bottom) 0.002â¦0.02 in² (1â¦16 mm²) AWG 18...AWG 8) - flexible |
| Wire stripping length | 0.6 in (14 mm) for top or bottom connection |
| Tightening torque | 22.1 lbf.in (2.5 N.m) top or bottom |
| Earth-leakage protection | Without |

Main
| Characteristic | Value(s) |
|---|---|
| Range | EVlink |
| product name | EVlink Wallbox |
| Product or component type | Charging station |
| Device short name | EVH2 |
| Poles description | 3P + N |
| Mounting mode | Wall-mounted |
| Offer type | Standard |
| Max power | 22 kW 32 A |
| Number of charge point | 1 |
| Connection to the vehicle | Attached cable T2 4 m |
| Access control system | Key |
Complementary
| Characteristic | Value(s) |
|---|---|
| rated supply voltage | 380...415 V AC 50/60 Hz |
| Earthing system | TT TN |
| Number of inputs | 1 |
| Input type | Contact for power limitation Contact for delayed charging |
| Control type | 1 white button, function: stop/restart Green button, function: cable unlocking |
| Local signalling | 1 multi-colour LED, function: status indication |
| Height | 480 mm |
| Width | 330 mm |
| Depth | 170 mm |
| Product weight | 7.5 kg |
| Colour | White (RAL 9003) Grey (RAL 7016) |
| Standards | IEC 62196-1 IEC 62196-2 IEC 61851-22 IEC 61851-1 |
| Product certifications | CB CE |

Main
| Characteristic | Value(s) |
|---|---|
| Range | EVlink |
| Product or component type | Cap |
| Mounting mode | Floor-standing |
| Socket number | 2 1 |
| Material | Steel with anti-corrosive coating |
Complementary
| Characteristic | Value(s) |
|---|---|
| Range compatibility | EVlink EVlink parking EVF2 charging station |
| Height | 1127 mm |
| Width | 413 mm |
| Depth | 109 mm |

This Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 4P circuit breaker with 4 protected poles, 45A rated current and B tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. The electrical endurance is up to 10000 cycles. The mechanical endurance is up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 8 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 72mm x (H) 81mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Multi9 |
| product name | Multi9 C60 |
| Product or Component Type | Miniature circuit-breaker |
| Device short name | C60SP |
| Device Application | Distribution |
| Poles description | 4P |
| Number of protected poles | 4 |
| Line Rated Current | 45 A 77 °F (25 °C) EN/IEC 60947-2 |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | B |
| Breaking capacity | 10 kA AIR 240 V AC UL 1077 10 kA AIR 240 V AC CSA C22.2 No 235 6 kA Icu 440 V AC EN/IEC 60947-2 10 kA Icu 415 V AC EN/IEC 60947-2 20 kA Icu 240 V AC EN/IEC 60947-2 6 kA Icu 440 V AC GB 14048.2 10 kA Icu 415 V AC GB 14048.2 20 kA Icu 240 V AC GB 14048.2 5 kA AIR 480Y/277 V AC UL 1077 5 kA AIR 480Y/277 V AC CSA C22.2 No 235 |
| Standards | EN/IEC 60947-2 GB 14048.2 UL 1077 CSA C22.2 No 235 |
| Product certifications | IEC CCC UR CSA |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ue] rated operational voltage | 240 V AC 50/60 Hz 415 V AC 50/60 Hz 440 V AC 50/60 Hz |
| Magnetic tripping limit | 4 x In +/- 20 % AC |
| [Ics] rated service breaking capacity | 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC 15 kA 75 % EN/IEC 60947-2 - 240 V AC 4.5 kA 75 % GB 14048.2 - 440 V AC 7.5 kA 75 % GB 14048.2 - 415 V AC 15 kA 75 % GB 14048.2 - 240 V AC |
| [Ui] rated insulation voltage | 500 V AC EN/IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kVEN/IEC 60947-2 |
| Suitability for isolation | Yes EN/IEC 60947-2 |
| Contact position indicator | Yes |
| Control Type | Toggle |
| Local signalling | ON/OFF indication |
| Mounting Mode | Clip-on |
| Mounting Support | DIN rail |
| 9 mm pitches | 8 |
| Height | 3.2 in (81 mm) |
| Width | 2.8 in (72 mm) |
| Depth | 2.8 in (72 mm) |
| color | Gray |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Provision for padlocking | Padlockable |
| Connections - terminals | Tunnel type terminal top or bottom) 0.002â¦0.05 in² (1â¦35 mm²) AWG 18...AWG 2) - rigid Tunnel type terminal top or bottom) 0.002â¦0.04 in² (1â¦25 mm²) AWG 18...AWG 3) - flexible with ferrule Tunnel type terminal top or bottom) 0.002â¦0.04 in² (1â¦25 mm²) AWG 18...AWG 3) - flexible |
| Wire stripping length | 0.6 in (14 mm) for top or bottom connection |
| Tightening torque | 31.0 lbf.in (3.5 N.m) top or bottom |
| Earth-leakage protection | Without |

Main
| Characteristic | Value(s) |
|---|---|
| Range | EVlink |
| product name | EVlink parking |
| Product or component type | Charging station |
| Device short name | EVW2 |
| Poles description | 1P + N for control circuit 1P + N for power circuit |
| Mounting mode | Wall-mounted |
| Offer type | Standard |
| rated supply voltage | 230 V AC 50/60 Hz power circuit 220...240 V AC 50/60 Hz control circuit |
| Earthing system | TN IT TT |
| socket-outlet number | 1 |
| socket-outlet type | Right: T2 with shutter / silver plated contacts |
| Maximum supply current | 32 A for T2 with shutter |
| Max power | 7 kW for T2 with shutter |
Complementary
| Characteristic | Value(s) |
|---|---|
| Control type | 1 red push-button, function: stop 1 green illuminated push-button, function: start/unlock flap |
| Local signalling | On charge: 1 LED (green) (flashing) on side Available: 1 LED (green) on front Reserved: 1 LED (orange) on front Not operational: 1 LED (red) on front |
| Communication port protocol | OCPP 1.6 |
| Configuration /Architecture | Standalone Clustered architecture |
| Operation and maintenance | User privilege configuration Diagnosis capabilities Load management Postponed charge Circuit breaker status Charge detail records |
| Web server | Embedded |
| Ethernet service | Configuration via web server |
| Standards | IEC 61851-22 IEC 61851-1 |
| Product certifications | ZE Ready CE CB EV Ready |
| Height | 620 mm |
| Width | 413 mm |
| Depth | 256 mm |
| Product weight | 33 kg |
| Colour | Front: white (RAL 9003) Side: grey (RAL 7016) |

Main
| Characteristic | Value(s) |
|---|---|
| Range | EVlink |
| product name | EVlink parking |
| Product or component type | Enclosure |
| Device short name | EVP2 |
| Range compatibility | EVlink EVlink parking EVF2 charging station EVlink EVlink parking EVW2 charging station |
| Poles description | 1P + N for control circuit 1P + N for power circuit |
| Mounting mode | Floor-standing Wall-mounted |
| Offer type | Standard |
| rated supply voltage | 230 V AC 50/60 Hz power circuit 220...240 V AC 50/60 Hz control circuit |
| Earthing system | TN IT TT |
| socket-outlet number | 2 |
| socket-outlet type | Right side: T2 with shutter / silver plated contacts Left side: T2 with shutter / silver plated contacts |
| Maximum supply current | 32 A for T2 with shutter |
| Max power | 7 kW for T2 with shutter |
Complementary
| Characteristic | Value(s) |
|---|---|
| Control type | 2 red push-button, function: stop 2 green illuminated push-button, function: start/unlock flap |
| Local signalling | On charge: 2 LED (green) (flashing) on side Available: 2 LED (green) on front Reserved: 2 LED (orange) on front Not operational: 2 LED (red) on front |
| Web server | Embedded |
| Ethernet service | Configuration via web server |
| Height | 625 mm |
| Width | 400 mm |
| Depth | 206 mm |
| Product weight | 20 kg |
| Colour | Grey (RAL 7016) |

Main
| Characteristic | Value(s) |
|---|---|
| Range | EVlink |
| Product or component type | Base |
| Mounting mode | Floor-standing |
| Material | Steel with anti-corrosive coating |
Complementary
| Characteristic | Value(s) |
|---|---|
| Range compatibility | EVlink EVlink parking EVF2 charging station |
| Product weight | 13 kg |
| Colour | Grey (RAL 7016) |

This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 10A rated current and Z tripping curve. The rated short circuit breaking capacity goes up to 3kA at 415VAC conforming to EN/IEC 60947-2 standard and 3kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 103mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Multi9 |
| product name | Multi9 C60 |
| Product or Component Type | Miniature circuit-breaker |
| Device short name | C60BP |
| Device Application | Distribution |
| Poles description | 1P |
| Number of protected poles | 1 |
| Line Rated Current | 10 A 77 °F (25 °C) EN/IEC 60947-2 |
| Network type | DC AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | Z |
| Breaking capacity | 3 kA Icu 415 V AC EN/IEC 60947-2 10 kA Icu 240 V AC EN/IEC 60947-2 20 kA Icu 60 V DC EN/IEC 60947-2 3 kA Icu 415 V AC GB 14048.2 10 kA Icu 240 V AC GB 14048.2 20 kA Icu 60 V DC GB 14048.2 10 kA AIR 277 V AC UL 489 14 kA AIR 240 V AC UL 489 14 kA AIR 120 V AC UL 489 10 kA AIR 60 V DC UL 489 10 kA AIR 277 V AC CSA C22.2 No 5 14 kA AIR 240 V AC CSA C22.2 No 5 14 kA AIR 120 V AC CSA C22.2 No 5 10 kA AIR 60 V DC CSA C22.2 No 5 |
| Standards | EN/IEC 60947-2 GB 14048.2 UL 489 CSA C22.2 No 5 |
| Product certifications | IEC CCC CSA UL |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ue] rated operational voltage | 240 V AC 50/60 Hz 415 V AC 50/60 Hz 60 V DC |
| Magnetic tripping limit | 3 x In +/- 20 % AC 4.2 x In +/- 20 % DC |
| [Ics] rated service breaking capacity | 2.25 kA 75 % EN/IEC 60947-2 - 415 V AC 7.5 kA 75 % EN/IEC 60947-2 - 240 V AC 2.25 kA 75 % GB 14048.2 - 415 V AC 7.5 kA 75 % GB 14048.2 - 240 V AC 15 kA 75 % GB 14048.2 - 60 V DC 15 kA 75 % EN/IEC 60947-2 - 60 V DC |
| [Ui] rated insulation voltage | 500 V AC EN/IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kVEN/IEC 60947-2 |
| Suitability for isolation | Yes EN/IEC 60947-2 |
| Contact position indicator | Yes |
| Control Type | Toggle |
| Local signalling | ON/OFF indication |
| Mounting Mode | Clip-on |
| Mounting Support | DIN rail |
| 9 mm pitches | 2 |
| Height | 4.06 in (103 mm) |
| Width | 0.7 in (18 mm) |
| Depth | 2.8 in (72 mm) |
| color | Gray |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Provision for padlocking | Padlockable |
| Connections - terminals | Tunnel type terminal top or bottom) 0.002â¦0.04 in² (1â¦25 mm²) AWG 18...AWG 8) - rigid Tunnel type terminal top or bottom) 0.002â¦0.02 in² (1â¦16 mm²) AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal top or bottom) 0.002â¦0.02 in² (1â¦16 mm²) AWG 18...AWG 8) - flexible |
| Wire stripping length | 0.6 in (14 mm) for top or bottom connection |
| Tightening torque | 22.1 lbf.in (2.5 N.m) top or bottom |
| Earth-leakage protection | Without |

This Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 50A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 3kA at 415VAC conforming to EN/IEC 60947-2 standard and 3kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 81mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Multi9 |
| product name | Multi9 C60 |
| Product or Component Type | Miniature circuit-breaker |
| Device short name | C60SP |
| Device Application | Distribution |
| Poles description | 1P |
| Number of protected poles | 1 |
| Line Rated Current | 50 A 77 °F (25 °C) EN/IEC 60947-2 |
| Network type | AC DC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 10 kA AIR 65 V DC UL 1077 10 kA AIR 65 V DC CSA C22.2 No 235 3 kA Icu 415 V AC EN/IEC 60947-2 10 kA Icu 240 V AC EN/IEC 60947-2 20 kA Icu 60 V DC EN/IEC 60947-2 3 kA Icu 415 V AC GB 14048.2 10 kA Icu 240 V AC GB 14048.2 20 kA Icu 60 V DC GB 14048.2 5 kA AIR 277 V AC UL 1077 10 kA AIR 240 V AC UL 1077 10 kA AIR 120 V AC UL 1077 5 kA AIR 277 V AC CSA C22.2 No 235 10 kA AIR 240 V AC CSA C22.2 No 235 10 kA AIR 120 V AC CSA C22.2 No 235 |
| Standards | EN/IEC 60947-2 GB 14048.2 UL 1077 CSA C22.2 No 235 |
| Product certifications | IEC CCC UR CSA |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ue] rated operational voltage | 240 V AC 50/60 Hz 415 V AC 50/60 Hz 60 V DC |
| Magnetic tripping limit | 8.5 x In +/- 20 % AC 12 x In +/- 20 % DC |
| [Ics] rated service breaking capacity | 2.25 kA 75 % EN/IEC 60947-2 - 415 V AC 7.5 kA 75 % EN/IEC 60947-2 - 240 V AC 20 kA 100 % EN/IEC 60947-2 - 60 V DC 2.25 kA 75 % GB 14048.2 - 415 V AC 7.5 kA 75 % GB 14048.2 - 240 V AC 20 kA 100 % GB 14048.2 - 60 V DC |
| [Ui] rated insulation voltage | 500 V AC EN/IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kVEN/IEC 60947-2 |
| Suitability for isolation | Yes EN/IEC 60947-2 |
| Contact position indicator | Yes |
| Control Type | Toggle |
| Local signalling | ON/OFF indication |
| Mounting Mode | Clip-on |
| Mounting Support | DIN rail |
| 9 mm pitches | 2 |
| Height | 3.2 in (81 mm) |
| Width | 0.7 in (18 mm) |
| Depth | 2.8 in (72 mm) |
| color | Gray |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Provision for padlocking | Padlockable |
| Connections - terminals | Tunnel type terminal top or bottom) 0.002â¦0.05 in² (1â¦35 mm²) AWG 18...AWG 2) - rigid Tunnel type terminal top or bottom) 0.002â¦0.04 in² (1â¦25 mm²) AWG 18...AWG 3) - flexible with ferrule Tunnel type terminal top or bottom) 0.002â¦0.04 in² (1â¦25 mm²) AWG 18...AWG 8) - flexible |
| Wire stripping length | 0.6 in (14 mm) for top or bottom connection |
| Tightening torque | 31.0 lbf.in (3.5 N.m) top or bottom |
| Earth-leakage protection | Without |

Main
| Characteristic | Value(s) |
|---|---|
| Accessory / separate part category | Connection accessories |
| Accessory / Separate Part Type | Connector |
| Accessory / separate part designation | Male connector |
Complementary
| Characteristic | Value(s) |
|---|---|
| Product Compatibility | CANopen bus |
| Connector Type | M12 |
| Pin number | 5 |
| Encoding type | A encoding |
| Product Weight | 0.11 lb(US) (0.05 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range | EVlink |
| product name | EVlink Wallbox |
| Product or component type | Charging station |
| Device short name | EVH2 |
| Poles description | 1P + N |
| Mounting mode | Wall-mounted |
| Offer type | Standard |
| Max power | 7.4 kW 32 A |
| Number of charge point | 1 |
| Connection to the vehicle | Attached cable T1 4 m |
| Access control system | Key |
Complementary
| Characteristic | Value(s) |
|---|---|
| rated supply voltage | 220...240 V AC 50/60 Hz |
| Earthing system | TT TN |
| Number of inputs | 1 |
| Input type | Contact for power limitation Contact for delayed charging |
| Control type | 1 white button, function: stop/restart Green button, function: cable unlocking |
| Local signalling | 1 multi-colour LED, function: status indication |
| Height | 480 mm |
| Width | 330 mm |
| Depth | 170 mm |
| Product weight | 7.5 kg |
| Colour | White (RAL 9003) Grey (RAL 7016) |
| Standards | IEC 61851-1 IEC 61851-22 IEC 62196-2 IEC 62196-1 |
| Product certifications | CB CE |

Main
| Characteristic | Value(s) |
|---|---|
| Accessory / separate part category | Connection accessories |
| Accessory / Separate Part Type | Connector |
| Accessory / separate part designation | Female connector |
Complementary
| Characteristic | Value(s) |
|---|---|
| Product Compatibility | CANopen bus |
| Connector Type | M12 |
| Pin number | 5 |
| Encoding type | A encoding |
| Product Weight | 0.11 lb(US) (0.05 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range | EVlink |
| Product or component type | Thin pole |
| Device short name | EVP1 |
| Mounting mode | Floor-standing |
| Material | Aluminium and plastic |
Complementary
| Characteristic | Value(s) |
|---|---|
| Range compatibility | EVlink EVlink Smart Wallbox EVB1 EVlink EVlink Wallbox EVH2 |
| Product weight | 17 kg |
| Colour | Grey (RAL 7016) White (RAL 9003) |

Main
| Characteristic | Value(s) |
|---|---|
| Accessory / separate part category | Connection accessories |
| Accessory / Separate Part Type | Connecting cable |
| Accessory / separate part designation | Bus connection cable |
| Cable length | 1.0 ft (0.3 m) |
Complementary
| Characteristic | Value(s) |
|---|---|
| Product Compatibility | CANopen bus DeviceNet bus |
| Electrical connection | 2 connectors M12, 5 pins A encoding), elbowed |
| Product Weight | 0.9 lb(US) (0.4 kg) |