Fuse kit 15A for SIPLUS PSU (20 units/set)
Connector set for VIB320/VIB321 -10 four-pole connectors for signal connection -2 ten-pole connectors for buffer outputs/DC-in -5 plug-in jumpers for redundant measurements -1 connector 2-pole for 5 V DC
10 terminal plates for signal cable VIB3000 -Strain relief -Shield support
CAN communication cable for redundant use of VIB316
Heating for explosion protection surface casing 6DL2804 consisting of heating, thermostat, connection terminals and the installation in the enclosure
ADDFEM (front end module) PROFIBUS device with high-speed I/O functions, redundant, FEF (front end function)
Connector set for VIB310 -24 connectors 3-pole for maximum signal assignment
Fuse kit 8A for SIPLUS PSU (20 units/set)
Mounting structure for stay mounting from the front, installation height approx. 470 mm, Overall depth approx. 245 mm
ADDFEM front end module PROFIBUS module with fast I/O functions, redundancy with FEF POCO plus (front-end function positioner plus)
VIB340B backplane for VIB3000 for accommodating up to -2 VIB310 -6 VIB320/VIB321 -1 VIB330 Power supply 2x24 V DC (connector enclosed), Cable inlet on the front
Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 95x M20 (6-13 mm) for signals in 5 rows, version in plastic blue. Ambient operating temperature min. -20 °C
Ex-device made of stainless steel, max. IP with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 60x M20 (6-13 mm) for signals in 5 rows, version brass nickel-plated. Ambient operating temperature min. -30 °C (heating must be ordered separately)
Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 36x M20 (6-13 mm) for signals in 3 rows, version in plastic blue. Ambient operating temperature min. -20 °C
Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 95x M20 (6-13 mm) for signals in 5 rows, plastic version. Ambient operating temperature min. -20 °C
SIMATIC TDC Round cable SC66 10-pole shielded, length 2m
Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 95x M20 (6-13 mm) for signals in 5 rows, plastic version. Ambient operating temperature min. -20 °C
Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 65x M16 (4-9 mm) for signals in 5 rows, version in plastic blue. Ambient operating temperature min. -20 °C
Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 57x M20 (6-13 mm) for signals in 3 rows, Version in metal. Ambient operating temperature min. -30 °C (heating must be ordered separately)
Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 65x M16 (4-9 mm) for signals in 5 rows, Version in metal. Ambient operating temperature min. -30 °C (heating must be ordered separately)
Ex-device made of stainless steel, IP65. With installation of the ET 200iSP and AirLineEx pneumatic components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 57x M20 (6-13 mm) for signals in 3 rows, version in plastic blue.
Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 60x M20 (6-13 mm) for signals in 5 rows, version in plastic blue. Ambient operating temperature min. -20 °C
Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 110x M16 (4-9 mm) for signals in 5 rows, version in plastic blue. Ambient operating temperature min. -20 °C
Ex-device made of stainless steel, IP65. Empty enclosure prepared for installation of the ET 200iSP. Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 95x M20 (6-13 mm) for signals in 5 rows, version in plastic blue. Ambient operating temperature -20 °C...+70 °C