Drives - Motors - Circuits Protection

1561 products

Showing 1081 - 1104 of 1561 products

Showing 1081 - 1104 of 1561 products
View
ACS850-04-08A0-5 ABB
ABB ACS850-04-08A0-5 ABB
Sale price0.00 kr
Sold Out

AC DRIVE, ACS850 SERIES, 3 PHASE, 5 HP, 7.6 AMP, 500 VAC, 500 HZ, DIRECT TORQUE CONTROL, PANEL MOUNTING, FRAME: A, IP20

ACS850-04-08A0-5+J400 ABB
ABB ACS850-04-08A0-5+J400 ABB
Sale price0.00 kr
Sold Out

AC Drive, Input Range VAC : 380 to 500 Volts AC, Input Phase : 3, HP : 5 Horsepower, Amps : 7.6 Amps, Max. Frequency : 500 Hertz, Braking Type : Flux Braking;Dynamic Braking Transistor Included, Operator Controls : Keypad Included, Mounting : PANEL

ACS850-04-290A-5 ABB
ABB ACS850-04-290A-5 ABB
Sale price0.00 kr
Sold Out

Cabinet Drive, 200 HP, 480 VAC, -04 - DRIVE MODULE W/OPTIONS, IP 20

ACS850-04-094A-5 ABB
ABB ACS850-04-094A-5 ABB
Sale price 73,397.00 kr
Only 2 units left

AC DRIVE, ACS850 SERIES, 60 HP, 480 VAC

ACS850-04-225A-5+J414 ABB
ABB ACS850-04-225A-5+J414 ABB
Sale price0.00 kr
Sold Out

Frequency inverter, ACS850 SERIES, 3 PHASE, 380-500 VAC, 225 AMP, 48/63 HZ, 110 KW, 150 HP

ACS880-01-017A-3 ABB
ABB ACS880-01-017A-3 ABB
Sale price 13,073.00 kr
Only 6 units left

AC Drive, 10HP 400V

ACS880-01-019A-7 ABB
ABB ACS880-01-019A-7 ABB
Sale price 46,605.00 kr
Only 2 units left

AC drive, Input Range VAC : 525 to 690 Volts AC; Input Phase : 3; HP : 15 Horsepower; Amps : 18 Amps; Max.

ACS880-01-027A-7 ABB
ABB ACS880-01-027A-7 ABB
Sale price 68,475.00 kr
Only 2 units left

AC DRIVE ACS880 SERIES, 3-PHASE, WALL MOUNTED, 27 AMP, 22 KW, 525-690 VAC, 50/60 HZ, FRAME SIZE R3

ACS880-01-025A-3 ABB
ABB ACS880-01-025A-3 ABB
Sale price 14,826.00 kr
Only 8 units left

AC Drive, 15HP 400V

ACS880-01-032A-3 ABB
ABB ACS880-01-032A-3 ABB
Sale price 17,224.00 kr
Only 10 units left

AC Drive, 20HP 400V

ACS880-01-02A1-5 ABB
ABB ACS880-01-02A1-5 ABB
Sale price 10,932.00 kr
In stock, 13 units

Drive, AC, 0.75HP, 480V, 1.7A, CT,N1 480Vin 3PH 1.0HP 2.1A VT W/DB Trans

1SBL297001R1200 ABB
ABB 1SBL297001R1200 ABB
Sale price0.00 kr
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
45 mm
Product Net Depth / Length:
86 mm
Product Net Height:
86 mm
Product Net Weight:
0.31 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 50 A
(690 V) 60 °C 42 A
(690 V) 70 °C 37 A
(690 V) 40 °C 50 A
(690 V) 60 °C 42 A
(690 V) 70 °C 37 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 38 A
(440 V) 60 °C 38 A
(500 V) 60 °C 33 A
(690 V) 60 °C 24 A
(380 / 400 V) 60 °C 38 A
(220 / 230 / 240 V) 60 °C 40 A
(415 V) 60 °C 38 A
(440 V) 60 °C 38 A
(500 V) 60 °C 33 A
(690 V) 60 °C 24 A
(380 / 400 V) 60 °C 38 A
(220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 38 A
(440 V) 60 °C 38 A
(500 V) 60 °C 33 A
(690 V) 60 °C 24 A
(380 / 400 V) 60 °C 38 A
(220 / 230 / 240 V) 60 °C 40 A
(415 V) 60 °C 38 A
(440 V) 60 °C 38 A
(500 V) 60 °C 33 A
(690 V) 60 °C 24 A
(380 / 400 V) 60 °C 38 A
(220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 50 A
(110 V) 2 Poles in Series, 60 °C 42 A
(110 V) 2 Poles in Series, 70 °C 37 A
(110 V) 3 Poles in Series, 40 °C 50 A
(110 V) 3 Poles in Series, 60 °C 42 A
(110 V) 3 Poles in Series, 70 °C 37 A
(220 V) 3 Poles in Series, 40 °C 50 A
(220 V) 3 Poles in Series, 60 °C 42 A
(220 V) 3 Poles in Series, 70 °C 37 A
(72 V) 1-Pole, 40 °C 50 A
(72 V) 1-Pole, 60 °C 42 A
(72 V) 1-Pole, 70 °C 37 A
(72 V) 2 Poles in Series, 40 °C 50 A
(72 V) 2 Poles in Series, 60 °C 42 A
(72 V) 2 Poles in Series, 70 °C 37 A
(72 V) 3 Poles in Series, 40 °C 50 A
(72 V) 3 Poles in Series, 60 °C 42 A
(72 V) 3 Poles in Series, 70 °C 37 A
(110 V) 2 Poles in Series, 40 °C 50 A
(110 V) 2 Poles in Series, 60 °C 42 A
(110 V) 2 Poles in Series, 70 °C 37 A
(110 V) 3 Poles in Series, 40 °C 50 A
(110 V) 3 Poles in Series, 60 °C 42 A
(110 V) 3 Poles in Series, 70 °C 37 A
(220 V) 3 Poles in Series, 40 °C 50 A
(220 V) 3 Poles in Series, 60 °C 42 A
(220 V) 3 Poles in Series, 70 °C 37 A
(72 V) 1-Pole, 40 °C 50 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 50 A
(110 V) 2 Poles in Series, 60 °C 42 A
(110 V) 2 Poles in Series, 70 °C 37 A
(110 V) 3 Poles in Series, 40 °C 50 A
(110 V) 3 Poles in Series, 60 °C 42 A
(110 V) 3 Poles in Series, 70 °C 37 A
(220 V) 3 Poles in Series, 40 °C 50 A
(220 V) 3 Poles in Series, 60 °C 42 A
(220 V) 3 Poles in Series, 70 °C 37 A
(72 V) 1-Pole, 40 °C 50 A
(72 V) 1-Pole, 60 °C 42 A
(72 V) 1-Pole, 70 °C 37 A
(72 V) 2 Poles in Series, 40 °C 50 A
(72 V) 2 Poles in Series, 60 °C 42 A
(72 V) 2 Poles in Series, 70 °C 37 A
(72 V) 3 Poles in Series, 40 °C 50 A
(72 V) 3 Poles in Series, 60 °C 42 A
(72 V) 3 Poles in Series, 70 °C 37 A
(110 V) 2 Poles in Series, 40 °C 50 A
(110 V) 2 Poles in Series, 60 °C 42 A
(110 V) 2 Poles in Series, 70 °C 37 A
(110 V) 3 Poles in Series, 40 °C 50 A
(110 V) 3 Poles in Series, 60 °C 42 A
(110 V) 3 Poles in Series, 70 °C 37 A
(220 V) 3 Poles in Series, 40 °C 50 A
(220 V) 3 Poles in Series, 60 °C 42 A
(220 V) 3 Poles in Series, 70 °C 37 A
(72 V) 1-Pole, 40 °C 50 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 50 A
(110 V) 2 Poles in Series, 60 °C 42 A
(110 V) 2 Poles in Series, 70 °C 37 A
(110 V) 3 Poles in Series, 40 °C 50 A
(110 V) 3 Poles in Series, 60 °C 42 A
(110 V) 3 Poles in Series, 70 °C 37 A
(220 V) 3 Poles in Series, 40 °C 25 A
(220 V) 3 Poles in Series, 60 °C 25 A
(220 V) 3 Poles in Series, 70 °C 25 A
(72 V) 1-Pole, 40 °C 25 A
(72 V) 1-Pole, 60 °C 25 A
(72 V) 1-Pole, 70 °C 25 A
(72 V) 2 Poles in Series, 40 °C 50 A
(72 V) 2 Poles in Series, 60 °C 42 A
(72 V) 2 Poles in Series, 70 °C 37 A
(72 V) 3 Poles in Series, 40 °C 50 A
(72 V) 3 Poles in Series, 60 °C 42 A
(72 V) 3 Poles in Series, 70 °C 37 A
(110 V) 2 Poles in Series, 40 °C 50 A
(110 V) 2 Poles in Series, 60 °C 42 A
(110 V) 2 Poles in Series, 70 °C 37 A
(110 V) 3 Poles in Series, 40 °C 50 A
(110 V) 3 Poles in Series, 60 °C 42 A
(110 V) 3 Poles in Series, 70 °C 37 A
(220 V) 3 Poles in Series, 40 °C 25 A
(220 V) 3 Poles in Series, 60 °C 25 A
(220 V) 3 Poles in Series, 70 °C 25 A
(72 V) 1-Pole, 40 °C 25 A
Rated Operational Power AC-3 (Pe):
(400 V) 18.5 kW
(415 V) 18.5 kW
(440 V) 22 kW
(500 V) 22 kW
(690 V) 22 kW
(380 / 400 V) 18.5 kW
(220 / 230 / 240 V) 11 kW
(400 V) 18.5 kW
(415 V) 18.5 kW
(440 V) 22 kW
(500 V) 22 kW
(690 V) 22 kW
(380 / 400 V) 18.5 kW
(220 / 230 / 240 V) 11 kW
Rated Operational Power AC-3e (Pe):
(415 V) 18.5 kW
(440 V) 22 kW
(500 V) 22 kW
(690 V) 22 kW
(380 / 400 V) 18.5 kW
(220 / 230 / 240 V) 11 kW
(415 V) 18.5 kW
(440 V) 22 kW
(500 V) 22 kW
(690 V) 22 kW
(380 / 400 V) 18.5 kW
(220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 48 ... 130 V
60 Hz 48 ... 130 V
DC Operation 48 ... 130 V
50 Hz 48 ... 130 V
60 Hz 48 ... 130 V
DC Operation 48 ... 130 V
Power Loss:
at Rated Operating Conditions AC-1 per Pole 2.4 W
at Rated Operating Conditions AC-3 per Pole 1.3 W
at Rated Operating Conditions AC-1 per Pole 2.4 W
at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time:
Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 4 mm²
Rigid Solid 1/2x 2.5 ... 4 mm²
Rigid Stranded 1/2x 2.5 ... 10 mm²
Flexible with Ferrule 1/2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 4 mm²
Rigid Solid 1/2x 2.5 ... 4 mm²
Rigid Stranded 1/2x 2.5 ... 10 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Main Circuit 14 mm
Control Circuit 10 mm
Main Circuit 14 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque:
Control Circuit 1.2 N·m
Main Circuit 2.5 N·m
Control Circuit 1.2 N·m
Main Circuit 2.5 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 50 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 2 hp
(200 ... 208 V AC) Three Phase 10 hp
(220 ... 240 V AC) Three Phase 10 hp
(240 V AC) Single Phase 5 hp
(440 ... 480 V AC) Three Phase 25 hp
(550 ... 600 V AC) Three Phase 30 hp
(120 V AC) Single Phase 2 hp
(200 ... 208 V AC) Three Phase 10 hp
(220 ... 240 V AC) Three Phase 10 hp
(240 V AC) Single Phase 5 hp
(440 ... 480 V AC) Three Phase 25 hp
(550 ... 600 V AC) Three Phase 30 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Solid 1/2x 14-10 AWG
Rigid Stranded 1/2x 14-8 AWG
Rigid Solid 1/2x 14-10 AWG
Rigid Stranded 1/2x 14-8 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Control Circuit 11 in·lb
Main Circuit 22 in·lb
Control Circuit 11 in·lb
Main Circuit 22 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 24 A
(200 ... 208 V AC) Three Phase 32.2 A
(220 ... 240 V AC) Three Phase 28 A
(240 V AC) Single Phase 28 A
(440 ... 480 V AC) Three Phase 34 A
(550 ... 600 V AC) Three Phase 32 A
(120 V AC) Single Phase 24 A
(200 ... 208 V AC) Three Phase 32.2 A
(220 ... 240 V AC) Three Phase 28 A
(240 V AC) Single Phase 28 A
(440 ... 480 V AC) Three Phase 34 A
(550 ... 600 V AC) Three Phase 32 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
Resistance to Vibrations:
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
16df62b9-0201-496a-ba58-9adaeae20846 China
Simplified SCIP:
cecf7012-0ac4-4b60-af61-a3dcc80839b9 Poland
fce21b3a-07c3-4a5e-84b6-fde5d347b7b5 Germany
f0255685-a8fb-4f82-8498-375b96592dde Germany
6c1893bb-e0cb-41c3-a220-29d1a4031fda Denmark
0ac191a4-9e57-4fb0-aeb1-7a2b003ea8d0 Croatia
2847c5ff-af67-40af-9e55-1768717f8f98 France
bbcb43e3-0814-492d-952e-88ffa78bd7c5 Germany
840788d9-c094-4025-9571-a7665f56f1ff Poland
bdc18c69-15e0-4586-81b1-1baa4a0378bc Portugal
ebd75545-9f7c-4111-a848-f9f3e36d606f Bulgaria
75aca07f-2282-4e30-8b45-102333c83b75 Sweden
3e956430-86a9-4370-ab51-94ebf9cb6e00 Belgium
a5137911-0f01-4df8-bfed-01ee75eb6a61 Hungary
e0f757dc-97fc-475b-8f7a-6dee741f35c0 Sweden
67f9fc7f-1224-41ae-97f6-17178ec024f3 Germany
bbd89bc0-f060-4f93-be77-6be9d35c5a98 France
16e3d0b6-948b-42db-a036-c189a36ef586 Spain
9e6e47f5-de8a-4816-8836-9cd3abb04b65 Finland
882b519d-5119-4528-8e9e-9c15aa5698e4 Norway
029c91ef-bec9-40a2-bae1-d4d72b91769d Czech Republic
f7037b18-4dce-4107-9384-8f6157119137 Estonia
a789f496-7543-4ad2-9a61-92095c99ebe0 Greece
4432a17e-12a5-404c-a6b4-b68e062ccb43 Netherlands
1a0a052b-3e20-4f32-9c10-5f625f95fad1 Hungary
579d9c4f-a080-4368-b893-f031ddcf6df4 Poland
497e0744-64d7-47a1-87d7-44e7803e6a57 Germany
29e5898e-b0a5-4d13-9492-3330b156fe29 Belgium
cecf7012-0ac4-4b60-af61-a3dcc80839b9 Poland
fce21b3a-07c3-4a5e-84b6-fde5d347b7b5 Germany
f0255685-a8fb-4f82-8498-375b96592dde Germany
6c1893bb-e0cb-41c3-a220-29d1a4031fda Denmark
0ac191a4-9e57-4fb0-aeb1-7a2b003ea8d0 Croatia
2847c5ff-af67-40af-9e55-1768717f8f98 France
bbcb43e3-0814-492d-952e-88ffa78bd7c5 Germany
840788d9-c094-4025-9571-a7665f56f1ff Poland
bdc18c69-15e0-4586-81b1-1baa4a0378bc Portugal
ebd75545-9f7c-4111-a848-f9f3e36d606f Bulgaria
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

Certificates and Declarations

A2L Certificate – UL:
GOST Certificate:
UL Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
87 mm
Package Level 1 Depth / Length:
87 mm
Package Level 1 Height:
47 mm
Package Level 1 Gross Weight:
0.31 kg
Package Level 1 EAN:
3471523111523
Package Level 2 Units:
box 21 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
315 mm
Package Level 2 Gross Weight:
13.95 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3706308
E-Number (Sweden):
3211385
ACS880-01-03A3-3 ABB
ABB ACS880-01-03A3-3 ABB
Sale price 9,025.00 kr
Only 10 units left

AC Drive, 1.5HP 400V

ACS880-01-03A4-5 ABB
ABB ACS880-01-03A4-5 ABB
Sale price 12,039.00 kr
Only 5 units left

Drive, AC, 1.5HP, 480V, 3.0A, CT, N1 480Vin 3PH 2.0HP 3.4A VT W/DB Trans

ACS880-01-04A0-3 ABB
ABB ACS880-01-04A0-3 ABB
Sale price 9,149.00 kr
Only 10 units left

AC Drive, 2HP 400V

ACS880-01-045A-3 ABB
ABB ACS880-01-045A-3 ABB
Sale price 21,034.00 kr
In stock, 16 units

AC DRIVE, ACS880 SERIES, 3-PHASE, WALL MOUNTED, 45 AMP, 22 KW, 380-415 VAC, 50/60 HZ, FRAME SIZE R4

ACS880-01-05A2-5 ABB
ABB ACS880-01-05A2-5 ABB
Sale price 13,672.00 kr
In stock, 15 units

AC Drive, 4HP 500V

ACS880-01-05A6-3 ABB
ABB ACS880-01-05A6-3 ABB
Sale price 9,589.00 kr
In stock, 11 units

AC Drive, 3HP 400V

ACS880-01-061A-2 ABB
ABB ACS880-01-061A-2 ABB
Sale price0.00 kr
Sold Out

AC Inverter for 11kW (15HP) 230V 3 Ph motor to 45A at high overload, or 15kW (2HP) to 58A when Fan/Pump rated. Operates in VxF, Sensorless Vector Direct Torque Control (DTC) as standard, or Closed-loop Speed Control when an optional Encoder Feedback card is fitted. Converts fixed frequency Three Phase 230V input to variable frequency 230V to control the speed of a standard AC induction motor, permanent magnet synchronous motor, servo motor or synchronous reluctance motor.

ACS880-01-05A6-3+E200 ABB
ABB ACS880-01-05A6-3+E200 ABB
Sale price0.00 kr
Sold Out

AC Inverter Drive, DBr, STO, C3 EMC, IP21 1.5kW/2.2kW 400V 3ph

1SBL241001R8032 ABB
ABB 1SBL241001R8032 ABB
Sale price0.00 kr
Sold Out

CONTACTOR, A SERIES, 220-230/230-240 VAC, 50/60 HZ, (A26-30-32 220-230V 50HZ / 230-240V 60HZ)

ACS880-01-07A2-3 ABB
ABB ACS880-01-07A2-3 ABB
Sale price 10,081.00 kr
Only 1 unit left

AC Drive, 4HP 400V

ACS880-01-07A4-7 ABB
ABB ACS880-01-07A4-7 ABB
Sale price 33,501.00 kr
Only 6 units left

Drive, AC, 3.0HP, 575V, 5.6A, CT, N1 575Vin 3PH 5.0HP 7.0A VT W/DB Trans

ACS143-4K1-1 ABB
ABB ACS143-4K1-1 ABB
Sale price0.00 kr
Sold Out

AC DRIVE, TYPE ACS140 FREQUENCY CONVERTER, FRAME SIZE D, 3 PHASE, 200-240 VAC INPUT, 50/60 HZ, 12.0 AMP, 0-300 HZ OUTPUT, 9.0 AMP, 2.2 KW / 3 HP

Recently viewed