Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
d594e546-ba15-46f2-8b28-e9b4d9d7418a Italy
4fa1e1bf-0efc-4422-b42e-ba5868924cb4 France
5735a74e-d12d-404f-a66a-bf72f4e57361 Greece
62a8452f-5642-4cac-b009-ca2681dc30aa Sweden
5c9cbd43-bdf2-4425-b26d-25b935328806 Germany
39ac7ebd-f060-40ba-91b5-ff26e049d40f France
a2c75b7e-744a-4f9c-8f65-d168b29205c0 Spain
cf5ce087-69af-481c-a0f7-1c5e4b12a77c Hungary
a6a91229-61ff-4c2c-931b-6195de8436b0 Estonia
09b1f980-0fdc-40e7-8a1e-23c04a61110f Sweden
406c2eda-63bb-4b92-bb3d-f6a69a138825 Germany
dc1ee1e8-f281-4a4d-8115-7f130ae1a1ac Portugal
6075808a-424f-49c2-abec-3fa77ce001c1 Germany
f0e9175b-4233-45f4-87af-842f82f98f93 Belgium
01f6b061-6fc5-4c1d-8328-32a8d0ed4f46 Bulgaria
0db072de-e280-4e77-8de9-c90044c3b66a Poland
cb4e80d6-287b-4183-af0c-7f834da25132 Belgium
450219e2-66d4-4bca-880f-d3f83521559a Czech Republic
88b6f0fd-0e70-43cd-8d2b-d2b73a02c4ab Poland
42ea1432-21d6-4907-95ca-c49a3aefbeec Germany
729a1e42-f5a8-47c7-a5f3-956a2c87db88 Netherlands
6b155d26-d69d-4fe3-be74-b42a06f99c91 Croatia
9ae73325-a4b3-42aa-b242-36afc17db2c7 Hungary
f89fce85-57f4-4bd1-9475-9455384c19e6 Norway
35ca74ba-7133-4d97-a2a1-8a9090c750c6 Germany
586b255e-4040-40f7-a91d-9dd2d10f3268 Denmark
867c4989-be99-408e-b9bb-928784cc06c8 Poland
31b94dcd-33e3-4107-91c5-2e605c901176 Finland
4fa1e1bf-0efc-4422-b42e-ba5868924cb4 France
5735a74e-d12d-404f-a66a-bf72f4e57361 Greece
62a8452f-5642-4cac-b009-ca2681dc30aa Sweden
5c9cbd43-bdf2-4425-b26d-25b935328806 Germany
39ac7ebd-f060-40ba-91b5-ff26e049d40f France
a2c75b7e-744a-4f9c-8f65-d168b29205c0 Spain
cf5ce087-69af-481c-a0f7-1c5e4b12a77c Hungary
a6a91229-61ff-4c2c-931b-6195de8436b0 Estonia
09b1f980-0fdc-40e7-8a1e-23c04a61110f Sweden
406c2eda-63bb-4b92-bb3d-f6a69a138825 Germany
Environmental
Ordering
8015644572778
1 piece
85362090
Dimensions
324 mm
461 mm
396.5 mm
49 kg
Container Information
1 piece
515 mm
600 mm
515 mm
59 kg
8015644572778
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
W
Technical
AC
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
330 W
2000 A
12 kV
1000 V
2000 A
690 V AC
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
for 1 s 55 kA
for 3 s 42 kA
for 1 s 55 kA
for 3 s 42 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
2000 A
690 V
PR121/P-LSI
EL
N
IEC
E2
Withdrawable Circuit-Breakers
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644571047
1 piece
85362090
Dimensions
296 mm
418 mm
302 mm
40 kg
Container Information
1 piece
515 mm
600 mm
515 mm
50 kg
8015644571047
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
F
Technical
AC
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
253 W
1600 A
12 kV
1000 V
1600 A
690 V AC
(220 V AC) 50 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(380 V AC) 50 kA
(690 V AC) 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(380 V AC) 50 kA
(690 V AC) 50 kA
for 1 s 50 kA
for 3 s 36 kA
for 1 s 50 kA
for 3 s 36 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(380 V AC) 50 kA
(690 V AC) 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(380 V AC) 50 kA
(690 V AC) 50 kA
1600 A
690 V
PR122/P-LSI
EL
N
IEC
E1
Fixed Circuit-Breakers
Rear flat Horizontal
Fixed Circuit-Breakers
Rear flat Horizontal
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644573744
1 piece
85362090
Dimensions
324 mm
461 mm
396.5 mm
49 kg
Container Information
1 piece
515 mm
600 mm
515 mm
59 kg
8015644573744
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
W
Technical
AC
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
330 W
2000 A
12 kV
1000 V
2000 A
690 V AC
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
for 1 s 65 kA
for 3 s 50 kA
for 1 s 65 kA
for 3 s 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
2000 A
690 V
PR121/P-LSIG
EL
S
IEC
E2
Withdrawable Circuit-Breakers
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644572723
1 piece
85362090
Dimensions
386 mm
418 mm
302 mm
56 kg
Container Information
1 piece
515 mm
600 mm
615 mm
68 kg
8015644572723
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
F
Technical
AC
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
4P
180 W
2000 A
12 kV
1000 V
2000 A
690 V AC
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
for 1 s 55 kA
for 3 s 42 kA
for 1 s 55 kA
for 3 s 42 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
2000 A
690 V
PR122/P-LSI
EL
N
IEC
E2
Fixed Circuit-Breakers
Rear flat Horizontal
Fixed Circuit-Breakers
Rear flat Horizontal
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
Main category name:Drives - Motors - Circuits Protection Vendor:ABB