SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 1,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4
Sinamics S120 CONVERTER POWER Module PM340 INPUT: 1AC 200-240V, 50/60HZ OUTPUT: 3AC 2,3A (0,37KW) FRAME SIZE: BLOCKSIZE SIZE FSA INTERNAL AIR COOLING
SINAMICS S120 POWER CONNECTOR WITH SCREW TERMINALS FOR MOTOR MODULES 3-30 A FRAME SIZE: BOOKSIZE
SINAMICS G120 POWER MODULE PM240P-2 WITH BUILT IN CL. A FILTER 3AC500-690V+10/-20% 47-63Hz OUTPUT HIGH OVERLOAD: 90KW FOR 150% 60S, 100% 240S; AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 110kW FOR 135% 3S, 110% 57S, 100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 708x 305x 357 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 SP6 HF1
SINAMICS Power Module PM240-2 with integrated Class A filter with integrated braking chopper 380-480 V 3 AC +10/-10% 47-63 Hz Power high overload: 0.75kW at 200% 3s, 150% 57s, 100% 240 s; Ambient temperature -10 to +50 °C; power low overload: 1.1kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature -10 to +40 °C 196x 73x 165 (HxWxD), FSA Degree of protection IP20 without Control Unit and operating unit Released as of CU firmware version V4.6
SINAMICS S120 DOUBLE MOTOR MODULE INPUT: DC 600V OUTPUT: 3AC 400V, 3A/3A FRAME SIZE: BOOKSIZE INTERNAL AIR COOLING OPTIMIZED PULSE SAMPLE AND SUPPORT OF THE EXTENDED SAFETY INTEGRATED FUNCTIONS INCL. DRIVE-CLIQ CABLE
SINAMICS Power Module PM240-2 unfiltered with integrated braking chopper 380-480 V 3 AC +10/-10% 47-63 Hz Power high overload: 2.2kW at 200% 3s, 150% 57s, 100% 240 s; Ambient temperature -10 to +50 °C; power low overload: 3kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature -10 to +40 °C 196x 73x 165 (HxWxD), FSA Degree of protection IP20 without Control Unit and operating unit Released as of CU firmware version V4.6
SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 2,2KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4
Sinamics G120C RATED POWER 2,2KW with 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF Integrated FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V Notes For this product a successor is available: 6SL3210-1KE15-8UP2
Sinamics S120 CONVERTER POWER Module PM340 INPUT: 1AC 200-240V, 50/60HZ OUTPUT: 3AC 0,9A (0,12KW) FRAME SIZE: BLOCKSIZE SIZE FSA with Integrated LINE FILTER INTERNAL AIR COOLING
SINAMICS POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 3KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 4KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.6
Sinamics G120 POWER Module PM230 with BUILT IN CL. A FILTER Protection IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 1,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT Control Unit and Panel APPROVED FOR CU240B/E-2 and CU230P-2 FIRMWARE-Version V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY Notes For this product a successor is available: 6SL3210-1NE14-1AG1
Sinamics S120 CONVERTER POWER Module PM340 INPUT 3AC 380-480V, 50 60HZ OUTPUT 3AC 5,9A (2,2KW) FRAME SIZE BLOCKSIZE SIZE FSB INTERNAL AIR COOLING
Sinamics G120 POWER Module PM230 with BUILT IN CL. A FILTER Protection IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 1,1KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT Control Unit and Panel APPROVED FOR CU240B/E-2 and CU230P-2 FIRMWARE-Version V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY Notes For this product a successor is available: 6SL3210-1NE13-1AG1
Sinamics G120C RATED POWER 2,2KW with 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF Integrated FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X225,4(HXWXD) EXTERNAL 24V Notes For this product a successor is available: 6SL3210-1KE15-8UF2
Sinamics S120 CONVERTER POWER Module PM340 INPUT: 1AC 200-240V, 50/60HZ OUTPUT: 3AC 2,3A (0,37KW) FRAME SIZE: BLOCKSIZE SIZE FSA with Integrated LINE FILTER INTERNAL AIR COOLING
Sinamics G120 POWER Module PM230 with BUILT IN CL. A FILTER Protection IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 4KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT Control Unit and Panel APPROVED FOR CU240B/E-2 and CU230P-2 FIRMWARE-Version V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY Notes Product is no longer available. Successor: 6SL3210-1NE21-0AG1
Sinamics S120 CONVERTER POWER Module PM340 INPUT: 1AC 200-240V, 50/60HZ OUTPUT: 3AC 0,9A (0,12KW) FRAME SIZE: BLOCKSIZE SIZE FSA INTERNAL AIR COOLING
Sinamics ZK-BUSBAR SET REINFORCED, FOR 50 MM Module BOOKSIZE FOR THE EXCHANGE FOR ZK 1 PACKAGE with 10 PCS FOR 5 Modules
Sinamics S120 POWER CONNECTOR C-/D-TYPE with PUSH-IN TERMINALS FOR MOTOR Modules 3-30 A FRAME SIZE: BOOKSIZE
SINAMICS S120 SINGLE MOTOR MODULE INPUT: DC 600V OUTPUT: 3AC 400V, 200A OUTPUT: at 8 kHz / 140A FRAME SIZE: BOOKSIZE INTERNAL AIR COOLING OPTIMIZED PULSE SAMPLE AND SUPPORT OF THE EXTENDED SAFETY INTEGRATED FUNCTIONS INCL. DRIVE-CLIQ CABLE
Sinamics SHIELD CONNECTION SHEET FOR 150 MM LINE MOTOR Modules INTERNAL AIR COOLING
Sinamics S120 CONVERTER POWER Module PM340 INPUT: 1AC 200-240V, 50/60HZ OUTPUT: 3AC 3,9A (0,75KW) FRAME SIZE: BLOCKSIZE SIZE FSA with Integrated LINE FILTER INTERNAL AIR COOLING
Sinamics G120 POWER Module PM230 with BUILT IN CL. A FILTER Protection IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 2,2KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT Control Unit and Panel APPROVED FOR CU240B/E-2 and CU230P-2 FIRMWARE-Version V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY Notes For this product a successor is available: 6SL3210-1NE15-8AG1