Drives - Motors - Circuits Protection

973 products

Showing 49 - 72 of 973 products

Showing 49 - 72 of 973 products
View
9007C54B2M11 Schneider
Schneider 9007C54B2M11 Schneider
Sale price0 kr
Sold Out

LIMIT SWITCH 600V 10AMP C +OPTIONS

9007BA5 Schneider
Schneider 9007BA5 Schneider
Sale price0 kr
Sold Out

LIMIT SWITCH LEVER ARM C +OPTIONS

9007C52KC Schneider Electric
Schneider 9007C52KC Schneider Electric
Sale price0 kr
Sold Out

LIMIT SWITCH 600V 10AMP C +OPTIONS

9007C54A2M11 Schneider
Schneider 9007C54A2M11 Schneider
Sale price0 kr
Sold Out

9007C limit switch - 1 NO/NC - rotary head - CW+CCW - low differential

9007C52B2M11 Schneider
Schneider 9007C52B2M11 Schneider
Sale price0 kr
Sold Out

9007C compact limit switch - 1 NO/NC - rotary head - CW+CCW - standard

9007C52B2 Schneider
Schneider 9007C52B2 Schneider
Sale price0 kr
Sold Out

LIMIT SWITCH 600V 10AMP C +OPTIONS

9007C52EM11 Schneider
Schneider 9007C52EM11 Schneider
Sale price0 kr
Sold Out

9007C compact limit switch - 1 NO/NC - top push rod plunger

9007C52F Schneider
Schneider 9007C52F Schneider
Sale price0 kr
Sold Out

LIMIT SWITCH 600V 10AMP C +OPTIONS

9007C54A2 Schneider
Schneider 9007C54A2 Schneider
Sale price0 kr
Sold Out

LIMIT SWITCH 600V 10AMP C +OPTIONS

9007C52J Schneider
Schneider 9007C52J Schneider
Sale price0 kr
Sold Out

LIMIT SWITCH 600V 10AMP C +OPTIONS

9007C52C Schneider
Schneider 9007C52C Schneider
Sale price0 kr
Sold Out

LIMIT SWITCH 600V 10AMP C +OPTIONS

9007BA4 Schneider
Schneider 9007BA4 Schneider
Sale price0 kr
Sold Out

9007C limit switch lever - zinc - fixed length - outside nylon roller

9007AP221 Schneider
Schneider 9007AP221 Schneider
Sale price0 kr
Sold Out

SNAP SWITCH 600VAC 15AMP AP +OPTIONS

A9D97410 Schneider Electric
Schneider A9D97410 Schneider Electric
Sale price0 kr
Sold Out

Acti9 iC60 RCBO - 4P - 10 A - B Curve - 6000A/6kA - 30 mA - SI type

A9D77432 Schneider Electric
Schneider A9D77432 Schneider Electric
Sale price0 kr
Sold Out

Acti9 iC60 RCBO - 4P - 32 A - C Curve - 6000A/6kA - 30 mA - SI type

A9D57420 Schneider Electric
Schneider A9D57420 Schneider Electric
Sale price0 kr
Sold Out

Acti9 iC60 RCBO - 4P - 20 A - C Curve - 6000A/6kA - 30 mA - AC type

A9D97416 Schneider Electric
Schneider A9D97416 Schneider Electric
Sale price0 kr
Sold Out

Acti9 iC60 RCBO - 4P - 16 A - B Curve - 6000A/6kA - 30 mA - SI type

A9D57432 Schneider Electric
Schneider A9D57432 Schneider Electric
Sale price0 kr
Sold Out

Acti9 iC60 RCBO - 4P - 32 A - C Curve - 6000A/6kA - 30 mA - AC type

A9E18320 Schneider Electric
Schneider A9E18320 Schneider Electric
Sale price0 kr
Sold Out

Acti9 iIL single indicator light - Red - 110-230 Vac

A9E15535 Schneider Electric
Schneider A9E15535 Schneider Electric
Sale price0 kr
Sold Out

This Acti9 iRLI product is a changeover relay. It has a changeover contact (C/O) and a normally open contact (NO). The Uc control circuit voltage is 230VAV to 240VAC with a 50/60Hz frequency.

Main

Characteristic Value(s)
range of product Acti9
product name Acti9 iRLI
Product or component type Relay
Device short name iRLI
Device application Changeover relay
Signal contacts composition 1 C/O + 1 NO
[Uc] control circuit voltage 230...240 V AC 50/60 Hz

Complementary

Characteristic Value(s)
[Ie] rated operational current 10 A at 230 V AC (cos Phi = 1)
[Ui] rated insulation voltage 250 V AC
Supply holding power 4 VA
Supply inrush power 4 VA
Mounting mode Fixed
Mounting support 35 mm symmetrical DIN rail
9 mm pitches 2
Height 88 mm
Width 18 mm
Depth 70 mm
Product weight 0.112 kg
Colour White
Electrical durability AC-21: 100000 cycles
Connections - terminals Tunnel type terminals 0.5…6 mm²
A9E18330 Schneider Electric
Schneider A9E18330 Schneider Electric
Sale price0 kr
Sold Out

Acti9 iIL single indicator light - Red - 12-48 Vac/dc

A9DE3625 Schneider Electric
Schneider A9DE3625 Schneider Electric
Sale price0 kr
Sold Out

This Acti9 iCV40 is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 25A In rated current and C tripping curve. The earth leakage protection class is AC type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 6000A according EN/IEC 61009-2-1 standard. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. Its 2 unique Visitrip indicators reduce intervention time by showing the faulty circuit and identifying quickly the type of default. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. This product is compliant with EN/IEC 61009-2-1 standard. It has an electrical endurance going up to 20000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50/60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 73mm. The weight is 210g. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.

Main

Characteristic Value(s)
Range Acti9
product name Acti9 iCV40
Product or component type Residual current breaker with overcurrent protection (RCBO)
Device short name iCV40N
Device application Distribution
Poles description 1P + N
Number of protected poles 1
Neutral position Left
[In] rated current 25 A
Network type AC
Network frequency 50/60 Hz
Trip unit technology Thermal-magnetic
Curve code C
Earth-leakage sensitivity 30 mA
Suitability for isolation Yes conforming to EN/IEC 60947-2
Quality labels VDE
EAC
IMQ

Complementary

Characteristic Value(s)
Device location in system Outgoer
[Ue] rated operational voltage 230 V AC 50/60 Hz
Magnetic tripping limit 5...10 x In
Residual current tripping technology Voltage independent
Earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type AC
Breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
[Ics] rated service breaking capacity 6000 A 100 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacity Idm 6000 A at 230 V AC 50/60 Hz conforming to EN 61009-2-1
Idm 500 A at 230 V AC 50/60 Hz conforming to IEC 61009-2-1
Limitation class 3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage 400 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 4 kV
Contact position indicator Yes
control type Toggle
Local signalling ON/OFF indication
Fault indication
Mounting mode Clip-on
Mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: tooth
Connection pitch 9 mm between phase and neutral
9 mm pitches 4
Height 85 mm
Width 36 mm
Depth 73 mm
Product weight 210 g
Colour White
Mechanical durability 20000 cycles
Electrical durability 20000 cycles
Locking options description Sealable
Padlocking device
Connections - terminals Tunnel type terminals top or bottom 1…16 mm² rigid
Tunnel type terminals top or bottom 1…10 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
Earth-leakage protection Integrated
A9D67416 Schneider Electric
Schneider A9D67416 Schneider Electric
Sale price 6 337 kr
Only 3 units left

This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 4P RCBO with 4 protected poles, rated current is 16A, and operating voltage is 380VAC to 415VAC. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. Breaking capacity at 280VAC to 415VAC is 6000A according to EN/IEC 61009-2-1 and 6kA according to EN/IEC 60947-2. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with EN/IEC 60947-2 and EN/IEC 61009-2-1 standards. Electrical endurance goes up to 10000 cycles, and mechanical endurance goes up to 20000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product color is white (RAL9003). The dimensions are (W) 72mm x (H) 86mm x (D) 78mm. The weight is 423g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -25°C to 40°C. The storage temperature is from -40°C to 70°C.

Main

Characteristic Value(s)
Range Acti9
product name Acti9 iC60 RCBO
Product or component type Residual current breaker with overcurrent protection (RCBO)
Device short name iC60 RCBO
Device application Distribution
Poles description 4P
Number of protected poles 4
[In] rated current 16 A
Network type AC
Network frequency 50 Hz
Trip unit technology Thermal-magnetic
Curve code C
Earth-leakage sensitivity 30 mA
Suitability for isolation No conforming to IEC 60947-1
Quality labels VDE
NF
IMQ
KEMA-KEUR

Complementary

Characteristic Value(s)
Device location in system Outgoer
[Ue] rated operational voltage 380...415 V AC 50 Hz
Magnetic tripping limit 5...10 x In
Residual current tripping technology Voltage independent
Earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type A
Breaking capacity 6000 A Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1
6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2
[Ics] rated service breaking capacity 6000 A 100 % x Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1
6 kA 100 % x Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2
Rated breaking and making capacity Idm 6000 A at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class 1 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage 500 V AC 50 Hz
[Uimp] rated impulse withstand voltage 4 kV
Surge current 250 A
Contact position indicator No
control type Toggle
Local signalling ON, OFF, fault trip
Mounting mode Clip-on
Mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
Bottom: biconnect
Connection pitch 9 mm between poles
9 mm pitches 8
Height 86 mm
Width 72 mm
Depth 78 mm
Product weight 423 g
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Tunnel type terminal top or bottom 1…35 mm² rigid
Tunnel type terminal top or bottom 1…25 mm² flexible
Tunnel type terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length 12 mm for top or bottom connection
Tightening torque 2 N.m
Earth-leakage protection Integrated
A9F90276 Schneider Electric
Schneider A9F90276 Schneider Electric
Sale price0 kr
Sold Out

This Acti9 iC60L is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 6.3A rated current and MA tripping curve. The rated short circuit breaking capacity goes up to 40kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuit against short circuit and overload current. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit. Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 78.5mm. The weight is 0.25kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C.

Main

Characteristic Value(s)
Device application Motor
Range Acti9
product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name iC60L
Poles description 2P
Number of protected poles 2
[In] rated current 6.3 A
Network type AC
Trip unit technology Magnetic
Curve code MA
Breaking capacity 15 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
40 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
Standards IEC 60947-2
EN 60947-2

Complementary

Characteristic Value(s)
Network frequency 50/60 Hz
Magnetic tripping limit 12 x In +/- 20 %
[Ics] rated service breaking capacity 10 kA 50 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
7.5 kA 50 % conforming to EN 60947-2 - 440 V AC 50/60 Hz
10 kA 50 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
7.5 kA 50 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz
20 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
20 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
Limitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator Yes
control type Toggle
Local signalling Trip indicator
Mounting mode Fixed
Mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 4
Height 85 mm
Width 36 mm
Depth 78.5 mm
Product weight 0.25 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
Earth-leakage protection Separate block

Recently viewed