ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
ZABQEGBQ200A000000XX
8015644752705
1 piece
85362090
Dimensions
280 mm
296 mm
183 mm
16 kg
Container Information
box 1 piece
350 mm
350 mm
330 mm
18 kg
8015644752705
Additional Information
SACE Emax 2
Air Circuit Breaker
Air Circuit Breaker
F
Technical
AC
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
100 %
4P
78 W
1000 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
100 %
for 1 s 42 kA
for 3 s 24 kA
for 1 s 42 kA
for 3 s 24 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
1000 A
690 V
Ekip G Hi-Touch LSIG
EL
B
IEC
E1.2
Yes, 690V
Front
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KXT1LTC-3
3638733
4381431
8015644693763
1 piece
85362090
Dimensions
0.049 kg
Container Information
box 1 piece
150 mm
20 mm
200 mm
0.052 kg
8015644693763
Additional Information
Accessories for Tmax XT
Accessory
Accessory
XT1
SACE Tmax XT
Technical
Loose or configurable
3P
1 piece
IEC60947-2
UL489
IEC60947-2
UL489
Certificates and Declarations
External Classifications and Standards
EC002268 - Cover cap for rail terminal bar
EC002268 - Cover cap for rail terminal bar
5219 >> Switch part or accessory
Q
39122221
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27400635

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.3 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
Environmental
Ordering
Z4SVENAA000A000000XX
8015644763510
1 piece
85362090
Dimensions
425 mm
425 mm
383 mm
60 kg
Container Information
box 1 piece
515 mm
610 mm
615 mm
67 kg
8015644763510
Additional Information
Technical
AC
Ue =< 440 V 7000 cycle
Ue = 500 ... 690 V 7000 cycle
20 cycles per hour
Ue =< 440 V 7000 cycle
Ue = 500 ... 690 V 7000 cycle
20 cycles per hour
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
3P
743 W
3200 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
100 %
for 1 s 66 kA
for 3 s 66 kA
for 1 s 66 kA
for 3 s 66 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
3200 A
690 V
Ekip Dip LI
EL
S
IEC
E4.2
Yes, 690V
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

Ordering
Dimensions
76 mm
130 mm
70 mm
1 kg
Container Information
1 piece
128 mm
135 mm
143 mm
1.1 kg
8015644661533
Additional Information
SACE Tmax T
Moulded Case Circuit Breaker
CB
F
Technical
8000 cycle
120 cycles per hour
8000 cycle
120 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
3P
at Rated Operating Conditions per Pole 1,8 W
20 A
8 kV
800 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 25 kA
(230 V AC) 25 kA
(380 V AC) 16 kA
(415 V AC) 16 kA
(440 V AC) 10 kA
(500 V AC) 8 kA
(690 V AC) 3 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(380 V AC) 16 kA
(415 V AC) 16 kA
(440 V AC) 10 kA
(500 V AC) 8 kA
(690 V AC) 3 kA
(220 V AC) 2.5 kA
(230 V AC) 2.5 kA
(380 V AC) 16 kA
(415 V AC) 16 kA
(440 V AC) 10 kA
(500 V AC) 8 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 16 kA
(250 V DC) 3 Poles in Series 20 kA
(500 V DC) 3 Poles in Series 16 kA
(220 V AC) 2.5 kA
(230 V AC) 2.5 kA
(380 V AC) 16 kA
(415 V AC) 16 kA
(440 V AC) 10 kA
(500 V AC) 8 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 16 kA
(250 V DC) 3 Poles in Series 20 kA
(500 V DC) 3 Poles in Series 16 kA
160 A
TMD
TM
B
IEC 60947
T1
Fixed Circuit-Breakers
Front for Copper Cables
Fixed Circuit-Breakers
Front for Copper Cables
3000 V
Certificates and Declarations
External Classifications and Standards
Q

Environmental
Ordering
8015644138332
1 piece
85389099
Dimensions
110 mm
60 mm
0.14 m
0.128 kg
Container Information
1 piece
60 mm
110 mm
0.128 kg
8015644138332
Additional Information
Spare Parts
Accessory
S3
S4
S5
S3
S4
S5
Isomax
Technical
S3-S4-S5
Certificates and Declarations
External Classifications and Standards
Q
5. Small Equipment (No External Dimension More Than 50 cm)

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644572525
1 piece
85362090
Dimensions
414 mm
461 mm
396.5 mm
61 kg
Container Information
1 piece
515 mm
600 mm
615 mm
73 kg
8015644572525
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
W
Technical
AC
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
4P
215 W
1600 A
12 kV
1000 V
1600 A
690 V AC
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
for 1 s 55 kA
for 3 s 42 kA
for 1 s 55 kA
for 3 s 42 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
1600 A
690 V
PR121/P-LI
EL
N
IEC
E2
Withdrawable Circuit-Breakers
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KXTASORCFPA
4384925
8015644692179
1 piece
85389099
Dimensions
0.114 kg
Container Information
box 1 piece
110 mm
60 mm
140 mm
0.12 kg
8015644692179
Additional Information
Accessories for Tmax XT
Accessory
Accessory
XT1, XT2, XT3, XT4
SACE Tmax XT
Technical
Loose or configurable
DC
1 piece
12 V DC
IEC60947-2
UL489
IEC60947-2
UL489
Certificates and Declarations
External Classifications and Standards
EC002483 - Switch spool for power circuit breaker
EC002483 - Switch spool for power circuit breaker
4879 >> Shunt release (for power circuit breaker)
Q
39121601
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370421

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
ZEAPWRS
4381725
3186271
8015644781057
1 piece
85389099
Dimensions
120 mm
155 mm
190 mm
0.05 kg
Container Information
box 1 piece
120 mm
155 mm
190 mm
0.06 kg
8015644781057
Additional Information
Accessories for Emax 2, Accessories for Tmax XT
Accessory
Accessory
XT7-XT7M, E1.2, E2.2, E4.2, E6.2
SACE Tmax XT, SACE Emax 2
Technical
Loose or configurable
1 piece
IEC
Certificates and Declarations
External Classifications and Standards
EC002498 - Accessories/spare parts for low-voltage switch technology
EC002498 - Accessories/spare parts for low-voltage switch technology
3592 >> Fieldbus, decentr. periphery - power supply module
Q
32151802
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371392

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
ZBBTEKBQ200A000000XX
8015644755102
1 piece
85362090
Dimensions
366 mm
371 mm
270 mm
53 kg
Container Information
box 1 piece
515 mm
610 mm
615 mm
58 kg
8015644755102
Additional Information
SACE Emax 2
Air Circuit Breaker
Air Circuit Breaker
F
Technical
AC
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
100 %
4P
212 W
2000 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
100 %
for 1 s 42 kA
for 3 s 42 kA
for 1 s 42 kA
for 3 s 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
2000 A
690 V
Ekip G Hi-Touch LSIG
EL
B
IEC
E2.2
Yes, 690V
Rear flat Horizontal
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KXT5R-3PC
4381041
8015644068523
1 piece
85389099
Dimensions
0.942 kg
Container Information
box 1 piece
507 mm
59 mm
311 mm
0.992 kg
8015644068523
Additional Information
Accessories for Tmax XT
Accessory
Accessory
XT5
SACE Tamx XT
Technical
Loose or configurable
3P
1 piece
IEC60947-2
UL489
IEC60947-2
UL489
Certificates and Declarations
External Classifications and Standards
EC002019 - Connection vane/phase spreader
EC002019 - Connection vane/phase spreader
4603 >> Electrical terminals
39121432
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371305

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KXTBPLLREM
4384957
8015644004989
1 piece
85389099
Dimensions
0.029 kg
Container Information
box 1 piece
145 mm
30 mm
250 mm
0.031 kg
8015644004989
Additional Information
Accessories for Tmax XT
Accessory
Accessory
XT1, XT3
SACE Tmax XT
Technical
Loose or configurable
1 piece
IEC60947-2
UL489
IEC60947-2
UL489
Certificates and Declarations
External Classifications and Standards
EC002498 - Accessories/spare parts for low-voltage switch technology
EC002498 - Accessories/spare parts for low-voltage switch technology
7344 >> Padlocks
Q
46171501
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371390

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644654597
1 piece
85362090
Dimensions
280 mm
268 mm
154 mm
12.5 kg
Container Information
1 piece
360 mm
350 mm
360 mm
14 kg
8015644654597
Additional Information
SACE Tmax T
Moulded Case Circuit Breaker
Automatic Circuit Breaker
T7
Moulded Case Circuit Breakers
F
Technical
2000 cycle
60 cycles per hour
2000 cycle
60 cycles per hour
10000 cycle
60 cycles per hour
10000 cycle
60 cycles per hour
4P
at Rated Operating Conditions per Pole 47 W
1250 A
8 kV
1000 V
690 V AC
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 70 kA
(400 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(690 V AC) 31.5 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 70 kA
(400 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(690 V AC) 31.5 kA
for 1 s 20 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 70 kA
(400 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(690 V AC) 42 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 70 kA
(400 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(690 V AC) 42 kA
1250 A
PR332/P LSI
EL
H
IEC
T7
Fixed Circuit-Breakers
Front
Fixed Circuit-Breakers
Front
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39121100
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644632120
1 piece
85389099
Dimensions
2.45 kg
Container Information
1 piece
145 mm
155 mm
295 mm
2.45 kg
8015644632120
Additional Information
Accessories for Tmax T
Accessory
Accessory
T6
SACE Tmax T
Technical
Loose or configurable
3P
IEC
Certificates and Declarations
External Classifications and Standards
EC002019 - Connection vane/phase spreader
EC002019 - Connection vane/phase spreader
Q
39121100
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371305

Environmental
Ordering
8015644135751
1 piece
85389099
Dimensions
105 mm
55 mm
0.135 m
0.097 kg
Container Information
1 piece
55 mm
105 mm
0.097 kg
8015644135751
Additional Information
Spare Parts
Accessory
S3
S4
S5
S3
S4
S5
Isomax
Technical
S3-S4-S5
Certificates and Declarations
External Classifications and Standards
Q
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
Z1NREHAN200A000000XX
8015644760472
1 piece
85362090
Dimensions
278 mm
363.5 mm
271 mm
18 kg
Container Information
box 1 piece
270 mm
350 mm
330 mm
20 kg
8015644760472
Additional Information
SACE Emax 2
Air Circuit Breaker
Air Circuit Breaker
W
Technical
AC
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 6500 cycle
30 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 6500 cycle
30 cycles per hour
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
3P
244 W
1250 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
100 %
for 1 s 50 kA
for 3 s 30 kA
for 1 s 50 kA
for 3 s 30 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
1250 A
690 V
Ekip G Touch LSIG
EL
N
IEC
E1.2
Yes, 690V
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644576523
1 piece
85362090
Dimensions
530 mm
418 mm
302 mm
76 kg
Container Information
1 piece
515 mm
600 mm
785 mm
90 kg
8015644576523
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
F
Technical
AC
Ue =< 440 V 6000 cycle
Ue = 500 ... 690 V 5000 cycle
20 cycles per hour
Ue =< 440 V 6000 cycle
Ue = 500 ... 690 V 5000 cycle
20 cycles per hour
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
4P
330 W
3200 A
12 kV
1000 V
3200 A
690 V AC
(220 V AC) 75 kA
(230 V AC) 75 kA
(380 V AC) 75 kA
(400 V AC) 75 kA
(415 V AC) 75 kA
(440 V AC) 75 kA
(500 V AC) 75 kA
(660 V AC) 75 kA
(690 V AC) 75 kA
(220 V AC) 75 kA
(230 V AC) 75 kA
(380 V AC) 75 kA
(400 V AC) 75 kA
(415 V AC) 75 kA
(440 V AC) 75 kA
(500 V AC) 75 kA
(660 V AC) 75 kA
(690 V AC) 75 kA
for 1 s 75 kA
for 3 s 65 kA
for 1 s 75 kA
for 3 s 65 kA
(220 V AC) 75 kA
(230 V AC) 75 kA
(380 V AC) 75 kA
(400 V AC) 75 kA
(415 V AC) 75 kA
(440 V AC) 75 kA
(500 V AC) 75 kA
(660 V AC) 75 kA
(690 V AC) 75 kA
(220 V AC) 75 kA
(230 V AC) 75 kA
(380 V AC) 75 kA
(400 V AC) 75 kA
(415 V AC) 75 kA
(440 V AC) 75 kA
(500 V AC) 75 kA
(660 V AC) 75 kA
(690 V AC) 75 kA
3200 A
690 V
PR121/P-LI
EL
S
IEC
E3
Fixed Circuit-Breakers
Rear flat Horizontal
Fixed Circuit-Breakers
Rear flat Horizontal
Certificates and Declarations
External Classifications and Standards
Q
4. Large Equipment (Any External Dimension More Than 50 cm)

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
Environmental
Ordering
Z2HTEKAD000A000000XX
8015644762544
1 piece
85362090
Dimensions
317 mm
425 mm
383 mm
48 kg
Container Information
box 1 piece
515 mm
610 mm
515 mm
53 kg
8015644762544
Additional Information
Technical
AC
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
450 W
2000 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
100 %
for 1 s 85 kA
for 3 s 66 kA
for 1 s 85 kA
for 3 s 66 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(525 V AC) 85 kA
(690 V AC) 85 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(525 V AC) 85 kA
(690 V AC) 85 kA
2000 A
690 V
Ekip Touch LI
EL
H
IEC
E2.2
Yes, 690V
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

Moulded / Molded Case Circuit Breaker (MCCB) - ABB / SACE (Tmax T (IEC) series) - T2N 160 MA20 Im=120...240 3p F F - 3-poles (3P3d) - Rated current 20A (160 oversized frame) - Short circuit breaking capacity (Icu) 36kA (415Vac) - Magnetic only (MA (adjustable)) trip unit

ABB
1SDA068070R1 ABB - XT3N 250 TMD 250-2500 4p F F InN100%
Sale price
4,253.00 kr
In stock, 12 unitsABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 56.6 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
4bf096d9-e0fb-41ce-9dab-01143bc6aed0 Italy
f122247f-3237-4c76-972d-808b882f9788 Germany
1f6795c1-9452-48f9-9d9a-f30ef9077f03 Spain
b2452708-7dc6-4407-9cd2-85d23e158939 Netherlands
cd120aec-54c5-4212-b458-6ac579d978f8 Netherlands
2010a811-d716-409f-8aa2-8c7dbaa7435e Germany
1df91a01-99c8-4fd4-9dd0-fd8633acf4dc Sweden
90e4f520-59d4-4837-b216-33abd64db25b Denmark
36f60159-a0f7-43ae-82ce-c05caa318767 Germany
3622c1af-6fb2-4105-a42f-ff7cf0cdd098 Poland
17df639b-1ddf-4990-b85a-b611ac0056b8 Norway
5c33c800-07e4-4dc9-a45b-a654c38bdcca Finland
578c2271-385e-47d4-96c2-78f0b62cd407 Netherlands
42f5d41d-9472-4bcb-af56-b4f5f0adb9f9 Croatia
17225d7a-362a-4551-ba19-a94719ff5cbc Czech Republic
ed0f2646-c591-4aa9-83ed-0341adcfcb9c Poland
0e3da230-1e90-44e5-810f-5ae4d4a053d7 Netherlands
91d082ac-941d-45ed-8bfd-30f694256596 Estonia
2b0f6517-2b81-4d17-9235-052143f7e69d Greece
230cead5-c984-438e-833a-fa9f9a190913 Portugal
734c1740-92a6-476b-8ab4-471386ae21a4 Bulgaria
9de1a02e-815c-4e49-b0ce-16ab721c88e0 Sweden
fdc9bfb7-1a5d-4026-8b82-a30c8c268ca7 Poland
86a701a4-5c49-4380-8b8a-1b53639cfd80 France
07da6dbe-40d9-4768-8eae-6b1fc5ae9a5a Germany
cb0986c3-7523-4eab-bacc-2d2b0ce88e8d Germany
ccbae2bd-88cc-42e1-a604-4b09aaa05639 France
f463799e-670e-49d3-8d9d-9d5d23697f1b Netherlands
f122247f-3237-4c76-972d-808b882f9788 Germany
1f6795c1-9452-48f9-9d9a-f30ef9077f03 Spain
b2452708-7dc6-4407-9cd2-85d23e158939 Netherlands
cd120aec-54c5-4212-b458-6ac579d978f8 Netherlands
2010a811-d716-409f-8aa2-8c7dbaa7435e Germany
1df91a01-99c8-4fd4-9dd0-fd8633acf4dc Sweden
90e4f520-59d4-4837-b216-33abd64db25b Denmark
36f60159-a0f7-43ae-82ce-c05caa318767 Germany
3622c1af-6fb2-4105-a42f-ff7cf0cdd098 Poland
17df639b-1ddf-4990-b85a-b611ac0056b8 Norway
Environmental
Ordering
XT3NE4250AFF000XXX
4309763
3182424
8015644019716
1 piece
85362090
Dimensions
140 mm
150 mm
70 mm
2.1 kg
Container Information
box 1 piece
155 mm
190 mm
155 mm
2.214 kg
8015644019716
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
Busbar 85..192 mm²
AC/DC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
4P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
at Rated Operating Conditions per Pole 17.8 W
250 A
50 / 60 Hz
8 kV
2500 A
800 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 2 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
250 A
690 V
Main Circuit M8
TMD
TM
175...250 A
N
IEC60947-2
XT3
Front
Bolt
8 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409