red Ø40 Emergency swtiching off push-button Ø22 non trigger - turn release 1NC
Communications interface module - ATEX compliant - ABB / B&R / BR / BandR (X20 series) - with 2 x RJ45 connectors - with Ethernet POWERLINK communication capability - Plug-in mounting - Rated for -25...+60°C ambient - order id #0xC3B3 / #50099 - equivalent to X20IF21812
X20 CPU, CELERON 400, 64 MB DRAM, 1 MB SRAM, EXCHANGEABLE APPLICATION MEMORY: COMPACTFLASH, 3 INSERT SLOTS FOR X20 INTERFACE MODULES, 2 USB INTERFACES, 1 RS232 INTERFACE, 1 ETHERNET INTERFACE 10/100 BASE-T, 1 POWERLINK INTERFACE, INCL. POWER SUPPLY MODULE, TB12 TERMINAL BLOCK AND SLOT COVERS, X20AC0SR1 X20 END PLATE RIGHT INCLUDED, ORDER PROGRAM MEMORY SEPARATELY.
X20CP1585 X20 CPU, ATOM 1.0 GHZ, 256 MB DDR2 RAM, 1 MB SRAM,
X20BM15
BUS MODULE
10AMP
24VDC
FOR X20 I/O MODULES
FACTORY WARRANTY MAY NOT APPLY. RADWELL 2-YEAR WARRANTY INCLUDED
4 inputs for resistance temperature measurement For PT100 and PT1000 Configurable sensor type per channel Direct resistance measurement Configurable 2- or 3- wire connections per module Configurable filter time The module is equipped with 4 inputs for PT100/PT1000 resistance temperature measurement.
6 digital outputs Relay module for 115 VAC 6 normally open contacts Single-channel isolated outputs The module is equipped with 6 relay outputs with normally open contacts for 115 VAC. The outputs are single-channel isolated.
2 digital outputs Relay module for 240 VAC / 30 VDC 2 change over contacts Single-channel isolated outputs The module is equipped with 2 relay outputs with changeover contacts for 240 VAC / 30 VDC. The outputs are single-channel isolated.
POWERLINK I/O configuration and firmware update via the fieldbus Integrated hub for economical wiring The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.
12 digital inputs Sink connection 1-wire connections Software input filter can be configured for entire module The module is equipped with 12 inputs for 1-wire connections. The module is designed for sink input wiring.
CAN bus connection Integrated terminating resistor The interface module can be used to expand the X20 CPU for specific applications. It is equipped with a CAN bus interface.
Resolver interface for installation in ACOPOS servo drives Monitors encoder input signals Resolver type BRX ACOPOS plug-in module, resolver interface 10 kH
2 safe digital inputs, sink circuit 2 pulse outputs Software input filter configurable for each channel 2 safe relay outputs Output type "Relay" Relay module for 48 VAC / 24 VDC Switching current 6 A Normally open contact Single-channel isolated outputs The module is equipped with 2 safe digital inputs and 2 safe relay outputs. It is designed for a nominal voltage of 24 VDC. The module can be used to read digital signals and for floating control of actuators in safety-related applications up to PL e or SIL 3. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. Safety relays are installed in the module. The positively driven feedback contacts are evaluated internally by the module. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.
Modular mechanical design using plug-in modules Integrated line filter Integrated braking resistor All connections are made using plug-in connectors Integrated electronic restart inhibit ACOPOS servo drive, 3x 400-480 V, 8.8 A, 4 kW, integrated line filter, braking resistor and electronic safe restart interlock
POWERLINK interface for installation in ACOPOS servo drives Integrated 2-port hub for easy wiring For communication and configuration of ACOPOS servo drives in complex and time-critical applications Node number configurable using switch ACOPOS plug-in module, POWERLINK V2 interface
EnDat 2.2 encoder interface for installation in ACOPOSmulti modules Encoder monitoring Embedded parameter chip when used with B&R motors ACOPOSmulti plug-in module, EnDat 2.2 interfac
Resolver interface for installation in ACOPOSmulti modules Encoder monitoring High resolution ACOPOSmulti plug-in module, resolver interface 10 kH
20 safe digital inputs 4 pulse outputs Sink circuit Software input filter configurable for each channel This module is equipped with 20 safe digital inputs. It is designed for a nominal voltage of 24 VDC. The module can be used to read various digital signals in safety-related applications up to PL e or SIL 3. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. This module is designed for X20 12-pin terminal blocks.
2 analog outputs Either current or voltage signal possible 13-bit digital converter resolution The module is equipped with 2 outputs with 13-bit (including sign) digital converter resolution. It is possible to select between the current and voltage signal using different terminals. This module is designed for X20 6-pin terminal blocks. If needed (e.g. for logistical reasons), the 12-pin terminal block can also be used.
2003 analog input module, 4 inputs, 0 to 20 mA, 12-bit, screw-in module, order 1x terminal block TB712 separately!
16 digital outputs Source connection 1-wire connections Integrated output protection The module is equipped with 16 outputs for 1-wire connections. The module is designed for source output wiring.
Tool-free wiring with push-in technology Simple wire release using a screwdriver Ability to label each terminal Plain text labeling also possible Test access for standard probes Can be customer-coded X20 24 VDC modules with 16 connections are wired using the X20TB1F terminal block.
Tool-free wiring with push-in technology Simple wire release using lever Ability to label each terminal Plain text labeling also possible Test access for standard probes Can be customer-coded The X20 24 VDC modules are wired using the X20TB06 and X20TB12 terminal blocks.