










Ordering
1 piece
85364110
Pluto
Programmable safety controller
Popular Downloads
Dimensions
120 mm
84 mm
45 mm
0.39 kg
Safety Information
Up to e
1
2
3
1
2
3
Technical
High
Failsafe 22
Failsafe (Transistor) 0
Failsafe (Relay) 0
Non-Failsafe 8
Failsafe (Transistor) 0
Failsafe (Relay) 0
Non-Failsafe 8
MODBUS ASCII, Pluto Safety Bus, StatusBus
24 V DC
24 V DC
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
90 mm
130 mm
57 mm
0.42 kg
7320500410561
External Classifications and Standards
V11.0 : 27242207
EC000236 - PLC CPU-module
EC000236 - PLC CPU-module
EC000236 - PLC CPU-module
3561 >> Programmable Logic Controller Module
32151705
K
2712235
3860081


Ordering
1 piece
85369095
Tina
DYNlink adapter
Yes
Popular Downloads
Dimensions
13 mm
46 mm
62 mm
0.035 kg
Technical
Black
24 V DC
24 V DC
Pluto AS-i v2
Pluto A20 v2
Pluto B20 v2
Pluto B22
Pluto B42 AS-i
Pluto B46 v2
Pluto D20
Pluto D45
Pluto D45 (Harsh Env)
Pluto O2
Pluto S20 v2
Pluto S46 v2
Vital 1
B&R X20
Pluto AS-i v2
Pluto A20 v2
Pluto B20 v2
Pluto B22
Pluto B42 AS-i
Pluto B46 v2
Pluto D20
Pluto D45
Pluto D45 (Harsh Env)
Pluto O2
24 V DC
Environmental
Operation -10 ... 55 °C
IP67
Plastic
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
bag 1 piece
100 mm
170 mm
0.015 m
0.037 kg
7350024451894
External Classifications and Standards
V11.0 : 27060313
EC001584 - I/O device for bus system
EC001584 - I/O device for bus system
EC003558 - Passive sensor-actuator interface (without cable)
5219 >> Switch part or accessory
39122221
T
2307387
3861360


ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 90.63 %
Recycled Paper - 00 %
Recycled Cardboard - 79 %
Recycled Paper - 00 %
Recycled Cardboard - 79 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
4 kV
(230 V) 6 kA
(230 V AC) 4.5 kA
Arbitrary
ON / OFF
3
10000 cycle
20000 cycle
1
1P+N
1
Right
1.2 N·m
Toggle
Cage Terminal
Yes
Flexible 1 … 10 mm²
Rigid 1 … 16 mm²
Flexible 1 … 10 mm²
Rigid 1 … 16 mm²
11 mm
Screw Terminals
Electrical
B
230 V AC
acc. to IEC 60898-1 230 V
acc. to IEC/EN 60664-1 500 V
4 kV
AC
16 A
(230 V) 4.5 kA
50 / 60 Hz
3.6 W
III
Design
Insulation group II, RAL 7035
Material Compliance
Following EU Directive 2011/65/EU
20190722
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Consumer
Environmental
Operation -25 ... +55 °C
30 °C
IP20
2
28 cycles
;with 55 °C / 90-96 %
;and 25 °C / 95-100 %
28 cycles
;with 55 °C / 90-96 %
;and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g or 0.35mm 5 … 150 … 5 Hz
30g 2 shocks 13 ms
Dimensions
1
18 mm
85 mm
69 mm
110 g
69 mm
Ordering
box 6 piece
0.684 kg
Certificates and Declarations
Installation
Any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
V11.0 : 27141901
F
IEC/EN 60898-1

Ordering
1 piece
85444290
JSTD25 Accessory
Cable
Popular Downloads
Dimensions
60 mm
28 mm
5000 mm
0.6 kg
Technical
JSTD25P-1
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
carton 1 piece
175 mm
275 mm
80 mm
0.7 kg
7350024460391
External Classifications and Standards
V11.0 : 27060102
EC000247 - Spiralized cable
EC000247 - Spiralized cable
EC000247 - Spiralized cable
W

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 90.63 %
Recycled Paper - 00 %
Recycled Cardboard - 79 %
Recycled Paper - 00 %
Recycled Cardboard - 79 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
4 kV
(230 V) 6 kA
(230 V AC) 4.5 kA
Arbitrary
ON / OFF
3
10000 cycle
20000 cycle
1
1P+N
1
Right
1.2 N·m
Toggle
Cage Terminal
Yes
Flexible 1 … 10 mm²
Rigid 1 … 16 mm²
Flexible 1 … 10 mm²
Rigid 1 … 16 mm²
11 mm
Screw Terminals
Electrical
B
230 V AC
acc. to IEC 60898-1 230 V
acc. to IEC/EN 60664-1 500 V
4 kV
AC
10 A
(230 V) 4.5 kA
50 / 60 Hz
1.9 W
III
Design
Insulation group II, RAL 7035
Material Compliance
Following EU Directive 2011/65/EU
20190722
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Consumer
Environmental
Operation -25 ... +55 °C
30 °C
IP20
2
28 cycles
;with 55 °C / 90-96 %
;and 25 °C / 95-100 %
28 cycles
;with 55 °C / 90-96 %
;and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g or 0.35mm 5 … 150 … 5 Hz
30g 2 shocks 13 ms
Dimensions
1
18 mm
85 mm
69 mm
110 g
69 mm
Ordering
box 6 piece
0.684 kg
Certificates and Declarations
Installation
Any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
V11.0 : 27141901
F
IEC/EN 60898-1

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 90.63 %
Recycled Paper - 00 %
Recycled Cardboard - 79 %
Recycled Paper - 00 %
Recycled Cardboard - 79 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
4 kV
(230 V) 6 kA
(230 V AC) 4.5 kA
Arbitrary
ON / OFF
3
10000 cycle
20000 cycle
1
1P+N
1
Right
1.2 N·m
Toggle
Cage Terminal
Yes
Flexible 1 … 10 mm²
Rigid 1 … 16 mm²
Flexible 1 … 10 mm²
Rigid 1 … 16 mm²
11 mm
Screw Terminals
Electrical
B
230 V AC
acc. to IEC 60898-1 230 V
acc. to IEC/EN 60664-1 500 V
4 kV
AC
6 A
(230 V) 4.5 kA
50 / 60 Hz
2.3 W
III
Design
Insulation group II, RAL 7035
Material Compliance
Following EU Directive 2011/65/EU
20190722
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Consumer
Environmental
Operation -25 ... +55 °C
30 °C
IP20
2
28 cycles
;with 55 °C / 90-96 %
;and 25 °C / 95-100 %
28 cycles
;with 55 °C / 90-96 %
;and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g or 0.35mm 5 … 150 … 5 Hz
30g 2 shocks 13 ms
Dimensions
1
18 mm
85 mm
69 mm
110 g
69 mm
Ordering
box 6 piece
0.684 kg
Certificates and Declarations
Installation
Any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
V11.0 : 27141901
F
IEC/EN 60898-1

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 75.20 %
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Recycled Cardboard - 98 %
Recycled Paper - 00 %
Chemically Recycled Polymer - 00 %
Recycled Cardboard - 98 %
Recycled Paper - 00 %
Chemically Recycled Polymer - 00 %
Product Durability
Technical
Type A
110 ... 264 V
2 kV
15 kA
EN 61009-1 6000 A
IEC 61009-1 6000 A
EN 61009-1 6000 A
IEC 61009-1 6000 A
11.2 kA
10 kA
Arbitrary
Red ON / Green OFF
3
10000 cycle
20000 cycle
1
1P+N
2
Blue Flag on Toggle
Instantaneous
Right
2.8 N·m
Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device
Toggle - Insulation group II, Black RAL 9005,
sealable in ON-OFF positions
Undelayed
Insulation group I - II, RAL 7035
Failsafe Bi-directional Cylinder-lift Terminal
Yes
0
Busbar 10 ... 10 mm²
Stranded 0.75 ... 25 mm²
Flexible with Ferrule 0.75 ... 16 mm²
Flexible 0.75 ... 16 mm²
Busbar 10 ... 10 mm²
Stranded 0.75 ... 25 mm²
Flexible with Ferrule 0.75 ... 16 mm²
Flexible 0.75 ... 16 mm²
1 - Solid-Core 0.75-25 mm²
4 - Multi-Wired 0.75-16 mm²
1 - Solid-Core 0.75-25 mm²
4 - Multi-Wired 0.75-16 mm²
12 mm
Screw Terminals
Electrical
C
acc. to IEC 60898-1 240 V
acc. to IEC/EN 60664-1 500 V
4 kV
AC
20 A
300 mA
10 kA
15 kA
50 … 60 Hz
Average per Pole 2.8 W
Phase Pole 3.8 W
Neutral Pole 1.8 W
Total 5.7 W
Average per Pole 2.8 W
Phase Pole 3.8 W
Neutral Pole 1.8 W
Total 5.7 W
III
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20211115
True - contains substances > 0.1 mass percentage
20240429
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Consumer
Environmental
Operation -25 … 55 °C
30 °C
IP20
IP40
IP20
IP40
2
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
25g 2 shocks 13 ms
Dimensions
2
35 mm
85 mm
69 mm
200 g
69 mm
Engineering
Ordering
box 1 piece
225 g
3211231
1683108
2100739
Certificates and Declarations
Installation
Popular Downloads
External Classifications and Standards
EC000905 - Earth leakage circuit breaker
EC000905 - Earth leakage circuit breaker
39121601
V11.0 : 27142207
4875 >> Residual current circuit breaker (RCCB)
F
IEC/EN 61009-1, IEC/EN 61009-2-1

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 90.63 %
Recycled Paper - 00 %
Recycled Cardboard - 79 %
Recycled Paper - 00 %
Recycled Cardboard - 79 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
4 kV
(230 V) 6 kA
(230 V AC) 4.5 kA
Arbitrary
ON / OFF
3
10000 cycle
20000 cycle
1
1P+N
1
Right
1.2 N·m
Toggle
Cage Terminal
Yes
Flexible 1 … 10 mm²
Rigid 1 … 16 mm²
Flexible 1 … 10 mm²
Rigid 1 … 16 mm²
11 mm
Screw Terminals
Electrical
C
230 V AC
acc. to IEC 60898-1 230 V
acc. to IEC/EN 60664-1 500 V
4 kV
AC
6 A
(230 V) 4.5 kA
50 / 60 Hz
2.3 W
III
Design
Insulation group II, RAL 7035
Material Compliance
Following EU Directive 2011/65/EU
20190722
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Consumer
Environmental
Operation -25 ... +55 °C
30 °C
IP20
2
28 cycles
;with 55 °C / 90-96 %
;and 25 °C / 95-100 %
28 cycles
;with 55 °C / 90-96 %
;and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g or 0.35mm 5 … 150 … 5 Hz
30g 2 shocks 13 ms
Dimensions
1
18 mm
85 mm
69 mm
110 g
69 mm
Ordering
box 6 piece
0.684 kg
3217709
Certificates and Declarations
Installation
Any
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
V11.0 : 27141901
F
IEC/EN 60898-1

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 75.20 %
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Recycled Cardboard - 98 %
Recycled Paper - 00 %
Chemically Recycled Polymer - 00 %
Recycled Cardboard - 98 %
Recycled Paper - 00 %
Chemically Recycled Polymer - 00 %
Product Durability
Technical
Type A
110 ... 264 V
2 kV
15 kA
EN 61009-1 6000 A
IEC 61009-1 6000 A
EN 61009-1 6000 A
IEC 61009-1 6000 A
11.2 kA
10 kA
Arbitrary
Red ON / Green OFF
3
10000 cycle
20000 cycle
1
1P+N
2
Blue Flag on Toggle
Instantaneous
Right
2.8 N·m
Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device
Toggle - Insulation group II, Black RAL 9005,
sealable in ON-OFF positions
Undelayed
Insulation group I - II, RAL 7035
Failsafe Bi-directional Cylinder-lift Terminal
Yes
0
Busbar 10 ... 10 mm²
Stranded 0.75 ... 25 mm²
Flexible with Ferrule 0.75 ... 16 mm²
Flexible 0.75 ... 16 mm²
Busbar 10 ... 10 mm²
Stranded 0.75 ... 25 mm²
Flexible with Ferrule 0.75 ... 16 mm²
Flexible 0.75 ... 16 mm²
1 - Solid-Core 0.75 … 25 mm²
4 - Multi-Wired 0.75 … 16 mm²
1 - Solid-Core 0.75 … 25 mm²
4 - Multi-Wired 0.75 … 16 mm²
12 mm
Screw Terminals
Electrical
C
acc. to IEC 60898-1 240 V
acc. to IEC/EN 60664-1 500 V
4 kV
AC
16 A
300 mA
10 kA
15 kA
50 … 60 Hz
Average per Pole 2.3 W
Phase Pole 3.4 W
Neutral Pole 1.2 W
Total 4.5 W
Average per Pole 2.3 W
Phase Pole 3.4 W
Neutral Pole 1.2 W
Total 4.5 W
III
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20211115
True - contains substances > 0.1 mass percentage
20240429
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Consumer
Environmental
Operation -25 … 55 °C
30 °C
IP20
IP40
IP20
IP40
2
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
25g 2 shocks 13 ms
Dimensions
2
35 mm
85 mm
69 mm
200 g
69 mm
Engineering
Ordering
box 1 piece
225 g
3211230
1683107
2100687
Certificates and Declarations
Installation
Popular Downloads
External Classifications and Standards
EC000905 - Earth leakage circuit breaker
EC000905 - Earth leakage circuit breaker
39121601
V11.0 : 27142207
4875 >> Residual current circuit breaker (RCCB)
F
IEC/EN 61009-1, IEC/EN 61009-2-1

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 75.20 %
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Recycled Cardboard - 98 %
Recycled Paper - 00 %
Chemically Recycled Polymer - 00 %
Recycled Cardboard - 98 %
Recycled Paper - 00 %
Chemically Recycled Polymer - 00 %
Product Durability
Technical
Type A
110 ... 264 V
2 kV
15 kA
EN 61009-1 6000 A
IEC 61009-1 6000 A
EN 61009-1 6000 A
IEC 61009-1 6000 A
11.2 kA
Arbitrary
Red ON / Green OFF
3
10000 cycle
20000 cycle
1
1P+N
2
Blue Flag on Toggle
Instantaneous
Right
2.8 N·m
Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device
Toggle - Insulation group II, Black RAL 9005,
sealable in ON-OFF positions
Insulation group I - II, RAL 7035
Failsafe Bi-directional Cylinder-lift Terminal
Yes
0
Busbar 10 ... 10 mm²
Stranded 0.75 ... 25 mm²
Flexible with Ferrule 0.75 ... 16 mm²
Flexible 0.75 ... 16 mm²
Busbar 10 ... 10 mm²
Stranded 0.75 ... 25 mm²
Flexible with Ferrule 0.75 ... 16 mm²
Flexible 0.75 ... 16 mm²
12 mm
Screw Terminals
Electrical
C
acc. to IEC 60898-1 240 V
acc. to IEC/EN 60664-1 500 V
4 kV
AC
10 A
300 mA
10 kA
15 kA
50 … 60 Hz
Average per Pole 1.2 W
Phase Pole 1.8 W
Neutral Pole 0.5 W
Total 2.3 W
Average per Pole 1.2 W
Phase Pole 1.8 W
Neutral Pole 0.5 W
Total 2.3 W
III
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20211115
True - contains substances > 0.1 mass percentage
20240429
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Consumer
Environmental
Operation -25 … 55 °C
30 °C
IP20
IP40
IP20
IP40
2
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
25g 2 shocks 13 ms
Dimensions
2
35 mm
85 mm
69 mm
200 g
69 mm
Engineering
Ordering
box 1 piece
225 g
3211229
1683105
2100685
Certificates and Declarations
Installation
Popular Downloads
External Classifications and Standards
EC000905 - Earth leakage circuit breaker
EC000905 - Earth leakage circuit breaker
39121601
V11.0 : 27142207
4875 >> Residual current circuit breaker (RCCB)
F
IEC/EN 61009-1, IEC/EN 61009-2-1

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 75.20 %
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Recycled Cardboard - 98 %
Recycled Paper - 00 %
Chemically Recycled Polymer - 00 %
Recycled Cardboard - 98 %
Recycled Paper - 00 %
Chemically Recycled Polymer - 00 %
Product Durability
Technical
Type A
110 ... 264 V
2 kV
15 kA
EN 61009-1 6000 A
IEC 61009-1 6000 A
EN 61009-1 6000 A
IEC 61009-1 6000 A
11.2 kA
Arbitrary
Red ON / Green OFF
3
10000 cycle
20000 cycle
1
1P+N
2
Blue Flag on Toggle
Instantaneous
Right
2.8 N·m
Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device
Toggle - Insulation group II, Black RAL 9005,
sealable in ON-OFF positions
Insulation group I - II, RAL 7035
Failsafe Bi-directional Cylinder-lift Terminal
Yes
0
Busbar 10 ... 10 mm²
Stranded 0.75 ... 25 mm²
Flexible with Ferrule 0.75 ... 16 mm²
Flexible 0.75 ... 16 mm²
Busbar 10 ... 10 mm²
Stranded 0.75 ... 25 mm²
Flexible with Ferrule 0.75 ... 16 mm²
Flexible 0.75 ... 16 mm²
12 mm
Screw Terminals
Electrical
C
acc. to IEC 60898-1 240 V
acc. to IEC/EN 60664-1 500 V
4 kV
AC
6 A
300 mA
10 kA
15 kA
50 … 60 Hz
Average per Pole 1.3 W
Phase Pole 2.4 W
Neutral Pole 0.2 W
Total 2.6 W
Average per Pole 1.3 W
Phase Pole 2.4 W
Neutral Pole 0.2 W
Total 2.6 W
III
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20211115
True - contains substances > 0.1 mass percentage
20240429
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Consumer
Environmental
Operation -25 … 55 °C
30 °C
IP20
IP40
IP20
IP40
2
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
25g 2 shocks 13 ms
Dimensions
2
35 mm
85 mm
69 mm
200 g
69 mm
Engineering
Ordering
box 1 piece
225 g
3211228
1683104
2100684
Certificates and Declarations
Installation
Popular Downloads
External Classifications and Standards
EC000905 - Earth leakage circuit breaker
EC000905 - Earth leakage circuit breaker
39121601
V11.0 : 27142207
4875 >> Residual current circuit breaker (RCCB)
F
IEC/EN 61009-1, IEC/EN 61009-2-1

