Filters
Siemens PLCs
52107 products
That’s why we at PLC Direct always set out to keep a diverse set of Siemens PLC hardware in stock. We especially stand by the brand’s PLC Siemens Simatic models for their commitment to customizability and constant improvability. Even if you require obsolete Siemens PLC parts or need a new PLC altogether, our selection of Siemens PLCs is exactly what you should seek out. Browse our collection below to assess this product’s availability and find something that works for your equipment. Once you find the right match, we can even get it to you without the unnecessary lead times. Shop here to learn more.
circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor starter protection ETU310M, I, In=200A short circuit protection Ii=3...12 x In busbar connection
circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor protection ETU350M, LSI, In=200A overload protection Ir=64A ... 200A short circuit protection Isd=3...12xIr, Ii=12xIn busbar connection
CIRCUIT BREAKER 3VA2 IEC FRAME 250 BREAKING CAPACITY CLASS C ICU=110KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=160A OVERLOAD PROTECTION IR=64A ...160A SHORT CIRCUIT PROTECTION ISD=1,2... 15X IN,II=3...15X IN BUSBAR CONNECTION
circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU350, LSI, In=250A overload protection Ir=100A ... 250A short circuit protection Isd=1,5...10xIr, Ii=10xIn neutral protection adjustable(OFF 50% 100%) busbar connection
circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor starter protection ETU310M, I, In=160A short circuit protection Ii=3...15 x In busbar connection
circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor protection ETU860M, LSIG, In=200A overload protection Ir=64A ... 200A short circuit protection Isd=1,2...12xIn, Ii=3...12xIn busbar connection
circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor protection ETU350M, LSI, In=160A overload protection Ir=64A ... 160A short circuit protection Isd=3...15xIr, Ii=15xIn busbar connection
CIRCUIT BREAKER 3VA2 IEC FRAME 250 BREAKING CAPACITY CLASS M ICU=55KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=160A OVERLOAD PROTECTION IR=64A ...160A SHORT CIRCUIT PROTECTION ISD=1,2... 15X IN,II=3...15X IN BUSBAR CONNECTION
CIRCUIT BREAKER 3VA2 IEC FRAME 160 BREAKING CAPACITY CLASS C ICU=110KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=63A OVERLOAD PROTECTION IR=25,2A ...63A SHORT CIRCUIT PROTECTION ISD=1,2... 15X IN,II=3...15X IN CABLE CONNECTION
CIRCUIT BREAKER 3VA2 IEC FRAME 160 BREAKING CAPACITY CLASS M ICU=55KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=63A OVERLOAD PROTECTION IR=25,2A ...63A SHORT CIRCUIT PROTECTION ISD=1,2... 15X IN,II=3...15X IN CABLE CONNECTION
CIRCUIT BREAKER 3VA2 IEC FRAME 160 BREAKING CAPACITY CLASS M ICU=55KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=63A OVERLOAD PROTECTION IR=25,2A ...63A SHORT CIRCUIT PROTECTION ISD=1,2... 15X IN,II=3...15X IN BUSBAR CONNECTION
circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor starter protection ETU310M, I, In=63A short circuit protection Ii=3...15 x In cable connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor starter protection ETU310M, I, In=63A short circuit protection Ii=3...15 x In busbar connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor protection ETU860M, LSIG, In=63A overload protection Ir=25A ... 63A short circuit protection Isd=1,2...15xIn, Ii=3...15xIn cable connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor protection ETU860M, LSIG, In=63A overload protection Ir=25A ... 63A short circuit protection Isd=1,2...15xIn, Ii=3...15xIn busbar connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor protection ETU350M, LSI, In=63A overload protection Ir=25A ... 63A short circuit protection Isd=3...15xIr, Ii=15xIn cable connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor protection ETU350M, LSI, In=63A overload protection Ir=25A ... 63A short circuit protection Isd=3...15xIr, Ii=15xIn busbar connection
circuit breaker 3VA2 IEC frame 250 breaking capacity class E Icu=200 kA @ 415 V 3-pole motor protection ETU860M, LSIG, In=160A overload protection Ir=64A ... 160A short circuit protection Isd=1,2...15xIn, Ii=3...15xIn busbar connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU860, LSIG, In=63A overload protection Ir=25A ... 63A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn neutral protection adjustable(OFF up to 160%) cable connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU860, LSIG, In=63A overload protection Ir=25A ... 63A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn neutral protection adjustable(OFF up to 160%) busbar connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU860, LSIG, In=63A overload protection Ir=25A ... 63A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn cable connection
CIRCUIT BREAKER 3VA2 IEC FRAME 160 BREAKING CAPACITY CLASS C ICU=110KA @ 415 V 3-POLE, MOTOR PROTECTION ETU550M, LSI, In=63A OVERLOAD PROTECTION IR=25,2A ...63A SHORT CIRCUIT PROTECTION ISD=1,2... 15X IN,II=3...15X IN BUSBAR CONNECTION
circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU860, LSIG, In=63A overload protection Ir=25A ... 63A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn busbar connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU850, LSI, In=63A overload protection Ir=25A ... 63A short circuit protection Isd=0,6...10xIn, Ii=1,5...12xIn neutral protection adjustable(OFF up to 160%) cable connection
Filters