Filters
Siemens PLCs
52107 products
That’s why we at PLC Direct always set out to keep a diverse set of Siemens PLC hardware in stock. We especially stand by the brand’s PLC Siemens Simatic models for their commitment to customizability and constant improvability. Even if you require obsolete Siemens PLC parts or need a new PLC altogether, our selection of Siemens PLCs is exactly what you should seek out. Browse our collection below to assess this product’s availability and find something that works for your equipment. Once you find the right match, we can even get it to you without the unnecessary lead times. Shop here to learn more.
circuit breaker 3VA5 UL frame 125 3-pole, starter protection TM120M, AM, In=2A without overload protection short-circuit protection Ii=3...7 x In without connection
circuit breaker 3VA2 IEC frame 1250 breaking capacity class C Icu=110kA @ 415 V 4-pole, line protection ETU860, LSIG, In=1250A overload protection Ir=500A ...1250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0,2... 1 x In, tg=0,05-0,8s nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class C Icu=110kA @ 415 V 3-pole, line protection ETU860, LSIG, In=1250A overload protection Ir=500A ...1250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In N conductor protection optional with ext. CT;up to160% gr.-fault prot., can be sw. off Ig=0,2... 1 x In, tg=0,05-0,8s nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class C Icu=110kA @ 415 V 4-pole, line protection ETU550, LSI, In=1250A overload protection Ir=500A ...1250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class C Icu=110kA @ 415 V 3-pole, line protection ETU550, LSI, In=1250A overload protection Ir=500A ...1250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In N conductor protection optional with ext. CT;up to160% nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class C Icu=110kA @ 415 V 4-pole, line protection ETU330, LIG, In=1250A overload protection Ir=500A ...1250A short circuit protection Ii=1,5...10 x In N conductor protection adjustable (OFF, up to 100%) ground-fault protection Ig=0,2... 1 x In, tg=0,1/0,3s nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class C Icu=110kA @ 415 V 4-pole, line protection ETU320, LI, In=1250A overload protection Ir=500A ...1250A short circuit protection Ii=1,5...10 x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class C Icu=110kA @ 415 V 3-pole, line protection ETU350, LSI, In=1250A overload protection Ir=500A ...1250A short circuit protection Isd=1,5... 10 xIr, Ii=10 x In nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class C Icu=110kA @ 415 V 4-pole, line protection ETU340, ELISA LI, In=1250A overload protection Ir=500A ...1250A short circuit protection Ii=10 x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class C Icu=110kA @ 415 V 3-pole, line protection ETU340, ELISA LI, In=1250A overload protection Ir=500A ...1250A short circuit protection Ii=10 x In nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class H Icu=85kA @ 415 V 4-pole, line protection ETU860, LSIG, In=1250A overload protection Ir=500A ...1250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0,2... 1 x In, tg=0,05-0,8s nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class H Icu=85kA @ 415 V 3-pole, line protection ETU860, LSIG, In=1250A overload protection Ir=500A ...1250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In N conductor protection optional with ext. CT;up to160% gr.-fault prot., can be sw. off Ig=0,2... 1 x In, tg=0,05-0,8s nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class H Icu=85kA @ 415 V 3-pole, line protection ETU550, LSI, In=1250A overload protection Ir=500A ...1250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In N conductor protection optional with ext. CT;up to160% nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class H Icu=85kA @ 415 V 3-pole, line protection ETU350, LSI, In=1250A overload protection Ir=500A ...1250A short circuit protection Isd=1,5... 10 X Ir, Ii=10 x In nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class H Icu=85kA @ 415 V 4-pole, line protection ETU330, LIG, In=1250A overload protection Ir=500A ...1250A short circuit protection Ii=1,5...10 x In N conductor protection adjustable (OFF, up to 100%) ground-fault protection Ig=0,2... 1 x In, tg=0,1/0,3s nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class C Icu=110kA @ 415 V 3-pole, line protection ETU330, LIG, In=1250A overload protection Ir=500A ...1250A short circuit protection Ii=1,5...10 x In ground-fault protection Ig=0,2... 1 x In, tg=0,1/0,3s nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class C Icu=110kA @ 415 V 3-pole, line protection ETU320, LI, In=1250A overload protection Ir=500A ...1250A short circuit protection Ii=1,5...10 x In nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class H Icu=85kA @ 415 V 3-pole, line protection ETU320, LI, In=1250A overload protection Ir=500A ...1250A short circuit protection Ii=1,5...10 x In nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class H Icu=85kA @ 415 V 4-pole, line protection ETU340, ELISA LI, In=1250A overload protection Ir=500A ...1250A short circuit protection Ii=10 x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class H Icu=85kA @ 415 V 3-pole, line protection ETU340, ELISA LI, In=1250A overload protection Ir=500A ...1250A short circuit protection Ii=10 x In nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class M Icu=55kA @ 415 V 4-pole, line protection ETU860, LSIG, In=1250A overload protection Ir=500A ...1250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In N conductor protection adjustable (OFF, up to 100%) gr.-fault prot., can be sw. off Ig=0,2... 1 x In, tg=0,05-0,8s nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class M Icu=55kA @ 415 V 3-pole, line protection ETU860, LSIG, In=1250A overload protection Ir=500A ...1250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In N conductor protection optional with ext. CT;up to160% gr.-fault prot., can be sw. off Ig=0,2... 1 x In, tg=0,05-0,8s nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class H Icu=85kA @ 415 V 4-pole, line protection ETU550, LSI, In=1250A overload protection Ir=500A ...1250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit
circuit breaker 3VA2 IEC frame 1250 breaking capacity class M Icu=55kA @ 415 V 4-pole, line protection ETU550, LSI, In=1250A overload protection Ir=500A ...1250A short circuit protection Isd=0,6..10x In, Ii=1,5..10x In N conductor protection adjustable (OFF, up to 100%) nut keeper kit
Filters