Filters
Siemens PLCs
52107 products
That’s why we at PLC Direct always set out to keep a diverse set of Siemens PLC hardware in stock. We especially stand by the brand’s PLC Siemens Simatic models for their commitment to customizability and constant improvability. Even if you require obsolete Siemens PLC parts or need a new PLC altogether, our selection of Siemens PLCs is exactly what you should seek out. Browse our collection below to assess this product’s availability and find something that works for your equipment. Once you find the right match, we can even get it to you without the unnecessary lead times. Shop here to learn more.
CIRCUIT BREAKER 3VA5 UL FRAME 400 BREAKING CAPACITY CLASS C 100kA @ 480 V 3POLE, LINE PROTECTION TM230, FTAM, In=225A OVERLOAD PROTECTION IR=225A FIXED SHORT CIRCUIT PROTECTION II=5...10 X IN UL489 SB (NAVAL), 50 DEG CEL. W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL FRAME 400 BREAKING CAPACITY CLASS C 100kA @ 480 V 3POLE, LINE PROTECTION TM230, FTAM, In=225A OVERLOAD PROTECTION IR=225A FIXED SHORT CIRCUIT PROTECTION II=5...10 X IN W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS M 35kA @ 480 V 2POLE, LINE PROTECTION TM230, FTAM, In=225A WITHOUT OVERLOAD PROTECTION IR=225A FIXED SHORT CIRCUIT PROTECTION Ii=5...10 x In W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS M 35kA @ 480 V 4POLE, LINE PROTECTION TM230, FTAM, In=225A WITHOUT OVERLOAD PROTECTION IR=225A FIXED SHORT CIRCUIT PROTECTION Ii=5...10 x In NEUTRAL UNPROTECTED W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS H 65kA @ 480 V 2POLE, LINE PROTECTION TM230, FTAM, In=225A WITHOUT OVERLOAD PROTECTION IR=225A FIXED SHORT CIRCUIT PROTECTION Ii=5...10 x In W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS M 35kA @ 480 V 4POLE, LINE PROTECTION TM230, FTAM, In=225A WITHOUT OVERLOAD PROTECTION IR=225A FIXED SHORT CIRCUIT PROTECTION Ii=5...10 x In NEUTRAL PROTECTION 100% W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS M 35kA @ 480 V 4POLE, LINE PROTECTION TM240, ATAM, In=225A WITHOUT OVERLOAD PROTECTION IR=157,5A ...225A SHORT CIRCUIT PROTECTION Ii=5...10 x In NEUTRAL UNPROTECTED W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS M 35kA @ 480 V 3POLE, LINE PROTECTION TM240, ATAM, In=225A WITHOUT OVERLOAD PROTECTION IR=157,5A ...225A SHORT CIRCUIT PROTECTION Ii=5...10 x In W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL FRAME 400 BREAKING CAPACITY CLASS C 100kA @ 480 V 4POLE, LINE PROTECTION TM240, ATAM, In=200A OVERLOAD PROTECTION IR=140A ...200A SHORT CIRCUIT PROTECTION II=5...10 X IN NEUTRAL UNPROTECTED W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS M 35kA @ 480 V 3POLE, LINE PROTECTION TM230, FTAM, In=225A WITHOUT OVERLOAD PROTECTION IR=225A FIXED SHORT CIRCUIT PROTECTION Ii=5...10 x In UL489 SB (NAVAL), 50 DEG CEL. W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL FRAME 400 BREAKING CAPACITY CLASS C 100kA @ 480 V 3POLE, LINE PROTECTION TM240, ATAM, In=200A OVERLOAD PROTECTION IR=140A ...200A SHORT CIRCUIT PROTECTION II=5...10 X IN W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL FRAME 400 BREAKING CAPACITY CLASS C 100kA @ 480 V 2POLE, LINE PROTECTION TM230, FTAM, In=200A OVERLOAD PROTECTION IR=200A FIXED SHORT CIRCUIT PROTECTION II=5...10 X IN W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL FRAME 400 BREAKING CAPACITY CLASS C 100kA @ 480 V 4POLE, LINE PROTECTION TM230, FTAM, In=200A OVERLOAD PROTECTION IR=200A FIXED SHORT CIRCUIT PROTECTION II=5...10 X IN NEUTRAL UNPROTECTED W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL FRAME 400 BREAKING CAPACITY CLASS C 100kA @ 480 V 3POLE, LINE PROTECTION TM230, FTAM, In=200A OVERLOAD PROTECTION IR=200A FIXED SHORT CIRCUIT PROTECTION II=5...10 X IN UL489 SB (NAVAL), 50 DEG CEL. W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL FRAME 400 BREAKING CAPACITY CLASS C 100kA @ 480 V 3POLE, LINE PROTECTION TM230, FTAM, In=200A OVERLOAD PROTECTION IR=200A FIXED SHORT CIRCUIT PROTECTION II=5...10 X IN W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS H 65kA @ 480 V 4POLE, LINE PROTECTION TM240, ATAM, In=200A WITHOUT OVERLOAD PROTECTION IR=140A ...200A SHORT CIRCUIT PROTECTION Ii=5...10 x In NEUTRAL PROTECTION 100% W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS H 65kA @ 480 V 4POLE, LINE PROTECTION TM230, FTAM, In=200A WITHOUT OVERLOAD PROTECTION IR=200A FIXED SHORT CIRCUIT PROTECTION Ii=5...10 x In NEUTRAL PROTECTION 100% W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS M 35kA @ 480 V 3POLE, LINE PROTECTION TM230, FTAM, In=225A WITHOUT OVERLOAD PROTECTION IR=225A FIXED SHORT CIRCUIT PROTECTION Ii=5...10 x In W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS H 65kA @ 480 V 3POLE, LINE PROTECTION TM240, ATAM, In=200A WITHOUT OVERLOAD PROTECTION IR=140A ...200A SHORT CIRCUIT PROTECTION Ii=5...10 x In W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL FRAME 400 BREAKING CAPACITY CLASS C 100kA @ 480 V 4POLE, LINE PROTECTION TM240, ATAM, In=200A OVERLOAD PROTECTION IR=140A ...200A SHORT CIRCUIT PROTECTION II=5...10 X IN NEUTRAL PROTECTION 100% W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL FRAME 400 BREAKING CAPACITY CLASS C 100kA @ 480 V 4POLE, LINE PROTECTION TM230, FTAM, In=200A OVERLOAD PROTECTION IR=200A FIXED SHORT CIRCUIT PROTECTION II=5...10 X IN NEUTRAL PROTECTION 100% W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS H 65kA @ 480 V 3POLE, LINE PROTECTION TM230, FTAM, In=200A WITHOUT OVERLOAD PROTECTION IR=200A FIXED SHORT CIRCUIT PROTECTION Ii=5...10 x In UL489 SB (NAVAL), 50 DEG CEL. W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS H 65kA @ 480 V 3POLE, LINE PROTECTION TM230, FTAM, In=200A WITHOUT OVERLOAD PROTECTION IR=200A FIXED SHORT CIRCUIT PROTECTION Ii=5...10 x In W/O CONNECTION
CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS M 35kA @ 480 V 4POLE, LINE PROTECTION TM240, ATAM, In=200A WITHOUT OVERLOAD PROTECTION IR=140A ...200A SHORT CIRCUIT PROTECTION Ii=5...10 x In NEUTRAL PROTECTION 100% W/O CONNECTION
Filters