SAFETY EXPANSION RELAY, E1T 3S, TIME DELAY 3 SEC, RELAY OUTPUTS 4NO, 24VDC
SAFETY RELAY, SINGLE CHANNEL, START/TEST, 24 VDC, 3NO/1 NC OUTPUT, SENTRY
Sentry BSR11 Safety relay and expansion relay with relay outputs 4NO, +24 VDC supply voltage and screw terminals. For monitoring of safety devices, such as emergency stops, directly in the voltage supply circuit of the relay.
Sentry SSR10M Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 2 equivalent channels.
SAFETY RELAY SENTRY, SSR20 24VDC, 24 VOLT DC, 3 NO + 1 NC, NO TIME DELAY
Sentry SSR42 Safety relay. Sentry SSR42 Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs.
Sentry SSR32 Safety relay. Sentry SSR32 Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels, and safety devices with OSSD outputs.
Sentry TSR20 Safety relay with delayed relay outputs 3NO+1NC, +24VDC power supply and screw terminals.
Sentry USR10 24VDC. Sentry USR10 Universal safety relay with delayable relay outputs 3NO+1NC, +24 VDC power supply and screw terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent or antivalent channels, safety devices with OSSD outputs, two-hand devices, safety mats and safety edges/bumpers. Timer function 0-999 seconds with a better accuracy than 1%: OFF-delay, ON-delay, Time bypass and Time reset.
Sentry TSR20M 85-265 VAC / 120-275 VDC
SAFETY RELAY, SENRTY, JOKAB SAFETY, TSR10 SERIES, TIME MONITORING, 24 VDC
Programmable Logic Controller PLC 128kB, 6DI/6DO-R/2AI/1AO, 24VDC, 1 x RS485, 2 x Option Slot
CONTROLLER, 128 KB, 8 DIGITAL INPUTS /6 DIGITAL OUTPUTS, ETH, 24 VDC, 1XRS485,2X OPTION SLOT
AC500, Programmable Logic Controller , 128kB, 8DI/6DO-R, 115-230VAC, 1xRS485, 2xOption Slot
AE/S4.1.1.3 Analogue Input, 4-fold, MDRC
Tina 12A DYNlink connection accessory. Tina 12A is a connection block for serie connection of two DYNlink devices with M12-8 connectors, e.g. Magne with Eden DYN. Two M12-8 female connectors for the devices and one M12-8 male connector towards the DYNlink loop.The Tina devices adapt the DYNlink safety circuit in Vital, Pluto and B&R X20 to safety components with mechanical contacts, such as E-stops, switches and light beams/curtains with dual outputs.Tina is available in several versions depending on the type of safety component that is connected to the Vital, Pluto or B&R X20 circuit.
PM583-ETH: AC500 Processor module. Memory 1MB. Interfaces: Ethernet, 2x RS232/485, FBP. Display.
PM 902F CPU Module
BC810K02 CEX-bus Interconnection Unit, 2 PCS BC810, INTERCONNECTION UNIT, 2 PCS TP857, BASEPLATE, TK851, INTERCONNECTION CABLE, 2 PCS TB850, CEX-BUS TERMINATOR
MOTION CONTROLLER, 24VDC, 50W, NEXTMOVE ESB2, 7AXIS, RS232
Electronic safety relay, Vital 3 24V DC dynamic safety module
BRIDGE CONTROLLER, HARMONY RACK / SYMPHONY PLUS, W/ MODBUS TCP INTERFACE, INFI90 / BRC410 / SPBRC41000000
LOGIC CONTROLLER, 32 CHANNELS, 18-30 VDC, 2 VDC, OUTPUT RATING: 0.01 A MINIMUM, AT 24 VDC 1.0 A MAXIMUM, 24 VDC CONTINUOUS, SURGE: 2.5 A PER CHANNEL, ISOLATION: 1K VDC, 10 MA PER CHANNEL, 4.7K OHM, 1.2K OHM, 4 W