Networkable hybrid motor starter for starting 3~�AC motors up to 500�V�AC, output current: 0.6�A, emergency stop function, adjustable overload shutdown, and Push-in connection, DIN rail connector provided.
Plug-in power solid-state relay, with LED and protective circuit in input and output circuits, input: 230 V AC, output: 12 - 60 V DC/max. 1 A, can be plugged into basic terminal blocks
Plug-in power solid-state relay, with LED and protective circuit in input and output circuits, input: 220 V DC, output: 12 - 60 V DC/max. 1 A, can be plugged into basic terminal blocks
Plug-in power solid-state relay, with LED and protective circuit in input and output circuits, input: 48 - 60 V DC, output: 12 - 60 V DC/max. 1 A, can be plugged into basic terminal blocks
Plug-in power solid-state relay, with LED and protective circuit in input and output circuits, input: 24 V DC, output: 12 - 60 V DC/max. 1 A, can be plugged into basic terminal blocks
Networkable hybrid motor starter for reversing 3~�AC motors up to 500�V�AC, output current: 3�A, adjustable overload shutdown, and Push-in connection, DIN rail connector provided.
Ex i measuring transducer repeater power supply, 2-channel, HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4...20mA signal from the Ex area to the safe area. PLd, screw connection. Replacement part: 2865382 MACX MCR-EX-SL-RPSS-2I-2I.
Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 420mA electrically isolated signals from the field to two loads. 4-way electrical isolation, PLd. Replacement part: 2924825 MACX MCR-SL-RPSSI-2I.
Ex i measuring transducer power supply and input signal conditioner, HART-transparent. Transfers supplied or active 0/4...20mA signals from the Ex area electrically isolated to two loads in the safe area. PLd, screw connection. Replacement part: 2865366 MACX MCR-EX-SL-RPSSI-2I.
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.
Safety relay for monitoring non-equivalent signal generators up to SILCL3, Cat.4, PLe, 2-channel, non-equivalent operation, manual, monitored start, 1 enabling current path, US=24VDC, fixed screw terminal block
Safety relay for monitoring non-equivalent signal generators up to SILCL3, Cat.4, PLe, 2-channel, non-equivalent operation, automatic start, 1 enabling current path, US=24VDC, fixed screw terminal block
Safety relay for emergency stop and safety doors up to SILCL3, Cat.4, PLe, 1 or 2-channel operation, manual, monitored start, 1 enabling current path, US=24VDC, fixed screw terminal block
Plug-in power solid-state relay, with LED and protective circuit in input and output circuits, input: 110 V DC, output: 12 - 60 V DC/max. 1 A, can be plugged into basic terminal blocks
Safety relay for emergency stop and safety doors up to SILCL3, Cat.4, PLe, 1 or 2-channel operation, manual, monitored start, cross-circuit detection, 1 enabling current path, US=24VDC, fixed screw terminal block
Safety relay for emergency stop and safety doors up to SILCL3, Cat.4, PLe, 1 or 2-channel operation, automatic start, cross-circuit detection, 1 enabling current path, US=24VDC, fixed screw terminal block
Safety relay for emergency stop and safety doors up to SILCL1, Cat.1, PLc, depending on the application up to SILCL 3, Cat.4, PLe, 1-channel operation, manual, monitored start, 1 enabling current path, US=24VDC, fixed screw terminal block
Safety relay for emergency stop and safety doors up to SILCL1, Cat.1, PLc, depending on the application up to SILCL3, Cat.4, PLe, 1-channel operation, automatic start, 1 enabling current path, US=24VDC, fixed screw terminal block
Patch panel, narrow design width, extended temperature range, two RJ45 sockets, 1:1 assignment, consistent shield, CAT5e, 10/100 Mbps, DIN rail mounting, IP20
Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal inputs, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, spring-cage connection, PLd. Replacement part: 2924799 MACX MCR-EX-T-UIREL-UP-SP.
Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 420mA electrically isolated signals from the field to two loads. 4-way electrical isolation, PLd. Replacement part: 2924838 MACX MCR-SL-RPSSI-2I-SP.
Freely programmable temperature transducer with analog output and 3 limit value relays, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, spring-cage connection, PLd. Replacement part: 2811828 MACX MCR-T-UIREL-UP-SP.
Freely programmable temperature transducer with analog output and 3 limit value relays, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, screw connection, PLd. Replacement part: 2811378 MACX MCR-T-UIREL-UP.
Safety relay for emergency stop, safety doors, and light grids up to SILCL3, Cat.4, PLe, 1 or 2-channel operation, automatic start, 2 enabling current paths (1-channel), US=24VDC, fixed screw terminal block