Single-channel contact extension with TBUS interface, 4 N/O contacts, 1 N/C contact, 1 confirmation current path, undelayed, Cat. 4, PL e according to EN ISO 13849, pluggable screw terminal blocks, width: 22.5 mm
Single-channel contact extension with TBUS interface, 4 N/O contacts, 1 N/C contact, 1 confirmation current path, the contacts have a release delay (0.3 s - 3 s), Cat. 3, PL e according to EN ISO 13849, plug-in spring-cage terminal block, width: 22.5 mm
Single-channel contact extension with TBUS interface, 4 N/O contacts, 1 N/C contact, 1 confirmation current path, the contacts have a release delay (0.3 s - 3 s), Cat. 3 , PL e according to EN ISO 13849, plug-in terminal blocks with screw connection, width: 22.5 mm
Single-channel contact extension with TBUS interface, 4 N/O contacts, 1 N/C contact, 1 confirmation current path, can be set with drop out delay of 0.5 - 30 sec., Cat. 3, PL e according to EN ISO 13849, pluggable screw terminal blocks, width: 22.5 mm
Single-channel contact extension with TBUS interface, 4 N/O contacts, 1 N/C contact, 1 confirmation current path, adjustable dropout delay of 0.5 - 30 s, Cat. 3, PL e according to EN ISO 13849, plug-in spring-cage terminal block, width: 22.5 mm
Single or two-channel contact extension, 5 N/O contacts, 1 N/C contact, 1 confirmation current path, plug-in spring-cage terminal block, width: 22.5 mm
Single or two-channel contact extension, 5 n/o contacts, 1 n/c contact, 1 confirmation current path, plug-in screw terminal blocks, width: 22.5 mm
Single or two-channel contact extension for OSSD signals (e.g., light grid), 3 N/O contacts, 1 N/C contact, up to Cat. 4 PL e according to EN ISO 13849, SIL 3 according to EN 62061, plug-in spring-cage terminal block, width: 22.5 mm
Short-circuit-proof hybrid motor starter for reversing 3~�AC motors up to 550�V�AC, with 24�V�DC input, 9�A output current, emergency stop function, and adjustable overload shutdown. Can only be used with EM-RD adapter, EM-RI adapter or power distribution board.
Short-circuit-proof hybrid motor starter for reversing 3~�AC motors up to 550�V�AC, with 24�V�DC input, 2.4�A output current, emergency stop function, and adjustable overload shutdown. Can only be used with EM-RD and EM-RI adapters or power distribution board.
Short-circuit-proof hybrid motor starter for reversing 3~�AC motors up to 550�V�AC, with 24�V�DC input, 0.6�A output current, emergency stop function, and adjustable overload shutdown. Can only be used with EM-RD and EM-RI adapters or power distribution board.
Set consisting of one 1�A measuring transducer and one UV-resistant Rogowski coil with signal line. Length of Rogowski coil: 600�mm, diameter: 190�mm. Length of signal line: 3�m. The Rogowski coil measures the AC current of busbars and power lines.
Set consisting of one 1�A measuring transducer and one Rogowski coil with signal line. Length of Rogowski coil: 450�mm, diameter: 140�mm. Length of signal line: 3�m. The Rogowski coil measures the AC current of busbars and power lines.
Set consisting of one 1�A measuring transducer and one Rogowski coil with signal line. Length of Rogowski coil: 450�mm, diameter: 140�mm. Length of signal line: 10�m. The Rogowski coil measures the AC current of busbars and power lines.
Set consisting of a 4-way signal conditioner with screw connection technology and a Rogowski coil 300 mm in length/95 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on the output side and has one switching output.
Set consisting of a 4-way signal conditioner with push-in connection technology and a Rogowski coil 600 mm in length/190 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on the output side and has one switching output.
Set consisting of a 4-way signal conditioner with push-in connection technology and a Rogowski coil 450 mm in length/140 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on the output side and has one switching output.
Set consisting of a 4-way signal conditioner with push-in connection technology and a Rogowski coil 300 mm in length/95 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on the output side and has one switching output.
Set consisting of a 1�A measuring transducer and a Rogowski coil with signal line. Length of Rogowski coil: 600�mm, diameter: 190�mm. Length of signal line: 3�m. The Rogowski coil measures the AC current of busbars and power lines.
Set consisting of a 1�A measuring transducer and a Rogowski coil with signal line. Length of Rogowski coil: 600�mm, diameter: 190�mm. Length of signal line: 10�m. The Rogowski coil measures the AC current of busbars and power lines.
Set consisting of a 1�A measuring transducer and a Rogowski coil with signal line. Length of Rogowski coil: 300�mm, diameter: 95�mm. Length of signal line: 5�m. The Rogowski coil measures the AC current of busbars and power lines.
Set consisting of a 1�A measuring transducer and a Rogowski coil with signal line. Length of Rogowski coil: 300�mm, diameter: 95�mm. Length of signal line: 3�m. The Rogowski coil measures the AC current of busbars and power lines.
Set consisting of a 1�A measuring transducer and a Rogowski coil with signal line. Length of Rogowski coil: 300�mm, diameter: 95�mm. Length of signal line: 10�m. The Rogowski coil measures the AC current of busbars and power lines.
Servo amplifier for DC motors with brushgear and EC motors (without brushgear)