Best selling products

25001 products

Showing 1321 - 1344 of 25001 products

Showing 1321 - 1344 of 25001 products
View
Keyence New Stock Image
Keyence PZ-G101CP Keyence
Sale price €152,95
Only 10 units left

Specifications

Model

PZ-G101CP

Type

Diffuse Reflective, Narrow view reflective

Shape

Rectangular

Output

PNP

Cable connection

M8 connector *1

Detecting distance

200 mm
7.87"

Spot diameter

Approx. 5 mm
0.20" dia.
(At a detecting
distance of
100 mm 3.94")

Light source

Red LED

Sensitivity adjustment

1-turn trimmer (230°)

Response time

500 µs

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Indicators (LED)

Output: Orange LED,
Stable operation: Green LED

Control output

Open collector output, 30 V max., 100 mA max., Residual voltage: 1 V max.

Protection circuit

Reversed polarity, overcurrent protection, surge absorber

Interference suppression

Up to 2 units
(with the automatic different frequency function)

Tightening torque

Rectangular models (Mounting hole part): 0.5 N m max.

Rating

Power voltage

10 to 30 VDC, including Ripple (P-P) 10 %

Current consumption

34 mA or less

Environmental resistance

Enclosure rating

IEC: IP67/NEMA: 4A, 6, 12/DIN: IP69K

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Housing, M18 nut
(threaded models only)

Glass-fiber reinforced PBT

Lens cover

Polyarylate (PAR)

Trimmer

Glass-fiber reinforced polyamide (PA)

Case connection

Screw: Nickel-plated iron and zinc, packing: nitrile butadiene rubber (NBR)

Cable (cable models only)

Polyvinyl chloride (PVC)

Connector (connector type with cable only)

Accessories

Instruction manual

Weight

Rectangular connector models: Approx. 10 g

*1 Cable sold separately for connector models

Keyence New Stock Image
Keyence GT2-H12 Keyence
Sale price €460,95
In stock, 15 units

Specifications

Model

GT2-H12

Detection system

Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error)

Measuring range

12 mm 0.47"

Resolution

0.5 μm 0.02 Mil

Indicated accuracy

2 µm 0.08 Mil (p-p)*1

Measuring force

Downward mounting

1.0 N*2

Side mounting

0.9 N*2

Upward mounting

0.8 N*2

Sampling cycle

1 ms

Mechanical response

10 Hz*1

Operation indicator light

2-color LED (red, green)

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2 (IEC60068-2-27)

Materials

Main body

Main body cast: Zinc die-casting, Indicator: Polyarylate, Dust boot: NBR

Dust boot

NBR

Contact

TYPE304, 440C Stainless steel*3

Sensor head cable

Optional (connect to the M8 connector)

Weight

Approx. 95 g (excluding cable)

*1 Value when the ambient temperature is 20 °C 68 °F.
*2 Value at center of measuring range. Please note that the measurement force changes depending on the installation state of the dust boots.
*3 The contact is included with the sensor.

QRI2A2-B180B Siemens
Siemens QRI2A2-B180B Siemens
Sale price €2.083,95
Only 5 units left

BRAND NEW CONDITION, GUARANTEED.

3TK2827-2BB40 Siemens
Siemens 3TK2827-2BB40 Siemens
Sale price €968,95
Only 5 units left
Product
Article Number (Market Facing Number) 3TK28272BB40 | 3TK28272BB40
Product Description SIRIUS safety relay with relay enabling circuits (EC) 24 V DC, 45 mm overall width Spring-type terminal EC instantaneous: 2 NO EC delayed: 2NO, 0.5...30 s SC: 1NC monitored start Basic device Maximum achieved SIL: 3/2, PL: e/d
Product family Not available
Product Lifecycle (PLM) PM490:Start of final year of support
Additional Product Information
EAN 4011209445390
UPC 754554653594
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 5837
Group Code R711
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 0.985 lb
Package size unit of measure Inch
Packaging Quantity 1
Mitsubishi New Stock Image
Mitsubishi MR-J2S-100A-S004 Mitsubishi
Sale price €694,95
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

6EP4134-3AB00-1AY0 Siemens
Siemens 6EP4134-3AB00-1AY0 Siemens
Sale price €363,95
In stock, 11 units
Product
Article Number (Market Facing Number) 6EP41343AB001AY0 | 6EP41343AB001AY0
Product Description SITOP UPS1600 10 A USB uninterruptible power supply with USB interface input: 24 V DC output: 24 V DC/10 A
Product family SITOP UPS1600 DC UPS modules
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4025515154198
UPC 887621705565
Commodity Code 85044060
LKZ_FDB/ CatalogID KT10-PD
Product Group 4215
Group Code R315
Country of origin Austria
SCIP number Not available
Delivery information
Net Weight (lb) 0.882 lb
Package size unit of measure Inch
Packaging Quantity 1
6SL3210-1KE27-0UF1 Siemens
Siemens 6SL3210-1KE27-0UF1 Siemens
Sale price €1.666,95
Only 7 units left
Product
Article Number (Market Facing Number) 6SL32101KE270UF1 | 6SL32101KE270UF1
Product Description SINAMICS G120C rated power: 37.0 kW with 150% overload for 3 s. 380-480 V 3AC +10/-20% 47-63 Hz unfiltered I/O interface: 6 DI, 2 DO, 1 AI, 1 AO Safe Torque Off integrated fieldbus integrated: PROFINET-PN degree of protection IP20/UL open type size: FSD 472x 200x 237 (HxWxD) external 24 V
Product family Ordering Data Overview
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4042948673232
UPC 804766375439
Commodity Code 85044086
LKZ_FDB/ CatalogID D11.1SD
Product Group 5820
Group Code R220
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 39.683 lb
Package size unit of measure Inch
Packaging Quantity 1
3TG1001-0BB4 Siemens
Siemens 3TG1001-0BB4 Siemens
Sale price €106,95
Only 5 units left
Product
Article Number (Market Facing Number) 3TG10010BB4 | 3TG10010BB4
Product Description power relay, AC-3, 8.4 A, 4 kW / 400 V, 3-pole, 24 V DC, auxiliary contacts: 1 NC, screw terminal
Product family 3TG10 power relays/miniature contactors
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4011209044975
UPC 754554730400
Commodity Code 85364190
LKZ_FDB/ CatalogID CC-IC10
Product Group 5810
Group Code R711
Country of origin Turkiye
SCIP number Not available
Delivery information
Net Weight (lb) 0.353 lb
Package size unit of measure in
Packaging Quantity 1
Proface New Stock Image
Proface GP-4301TW Proface
Sale price €560,95
Only 9 units left
  • OPERATOR INTERFACE
  • 5.7" TFT COLOR TOUCH (ANALOG)
  • QVGA
  • 2X SERIAL
  • ETHERNET
  • 2X USB
  • 24VDC
  • UL/CE
  • (PFXGP4301TADW)
1SFL511001R8011 ABB - A210-30-11-80
ABB 1SFL511001R8011 ABB - A210-30-11-80
Sale price €494,95
Only 7 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900
Replacement Product ID (NEW):

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals:
Dimension Diagram:

Dimensions

Product Net Width:
140 mm
Product Net Depth / Length:
180.5 mm
Product Net Height:
227 mm
Product Net Weight:
5.4 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Number of Poles:
3P
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 350 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 350 A
(690 V) 55 °C 300 A
(690 V) 70 °C 240 A
(690 V) 40 °C 350 A
(690 V) 55 °C 300 A
(690 V) 70 °C 240 A
Rated Operational Current AC-3 (Ie):
(415 V) 55 °C 210 A
(440 V) 55 °C 210 A
(500 V) 55 °C 210 A
(690 V) 55 °C 210 A
(380 / 400 V) 55 °C 210 A
(220 / 230 / 240 V) 55 °C 210
(415 V) 55 °C 210 A
(440 V) 55 °C 210 A
(500 V) 55 °C 210 A
(690 V) 55 °C 210 A
(380 / 400 V) 55 °C 210 A
(220 / 230 / 240 V) 55 °C 210
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Power AC-3 (Pe):
(415 V) 110 kW
(440 V) 110 kW
(500 V) 132 kW
(690 V) 160 kW
(380 / 400 V) 110 kW
(220 / 230 / 240 V) 59 kW
(415 V) 110 kW
(440 V) 110 kW
(500 V) 132 kW
(690 V) 160 kW
(380 / 400 V) 110 kW
(220 / 230 / 240 V) 59 kW
Rated Breaking Capacity AC-3:
8 x Ie AC-3
Rated Making Capacity AC-3:
10 x Ie AC-3
Short-Circuit Protective Devices:
gG Type Fuses 400 A
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1200 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2200 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2200 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2000 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 8 kV
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
Mechanical Durability:
5 million
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc):
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 50 Hz 60 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 65 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1350 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1550 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 60 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 65 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1350 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1550 V·A
Power Loss:
at Rated Operating Conditions per Pole 9 W
Operate Time:
Between Coil De-energization and NC Contact Closing 7 ... 13 ms
Between Coil De-energization and NO Contact Opening 10 ... 16 ms
Between Coil Energization and NC Contact Opening 12 ... 30 ms
Between Coil Energization and NO Contact Closing 17 ... 35 ms
Between Coil De-energization and NC Contact Closing 7 ... 13 ms
Between Coil De-energization and NO Contact Opening 10 ... 16 ms
Between Coil Energization and NC Contact Opening 12 ... 30 ms
Between Coil Energization and NO Contact Closing 17 ... 35 ms
Connecting Capacity Main Circuit:
Bar 32 mm²
Rigid Al-Cable 2 x 95 ... 120 mm²
Rigid Cu-Cable 16 ... 240 mm²
Bar 32 mm²
Rigid Al-Cable 2 x 95 ... 120 mm²
Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Connecting Capacity:
Bar 32 mm²
Rigid Al-Cable 2 x 95 ... 120 mm²
Rigid Cu-Cable 16 ... 240 mm²
Bar 32 mm²
Rigid Al-Cable 2 x 95 ... 120 mm²
Rigid Cu-Cable 16 ... 240 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main Poles:
Flat type c/w screws and bolts
Tightening Torque:
Main Circuit 18 N·m
Terminal Type:
Main Circuit: Bars
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 300 A
Horsepower Rating UL/CSA:
(200 V AC) Three Phase 60 hp
(208 V AC) Three Phase 60 hp
(220 ... 240 V AC) Three Phase 75 hp
(440 ... 480 V AC) Three Phase 150 hp
(550 ... 600 V AC) Three Phase 200 hp
(200 V AC) Three Phase 60 hp
(208 V AC) Three Phase 60 hp
(220 ... 240 V AC) Three Phase 75 hp
(440 ... 480 V AC) Three Phase 150 hp
(550 ... 600 V AC) Three Phase 200 hp
Full Load Amps Motor Use:
(440 ... 480 V AC) Three Phase 180 A
(550 ... 600 V AC) Three Phase 192 A
(440 ... 480 V AC) Three Phase 180 A
(550 ... 600 V AC) Three Phase 192 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Shock Direction: A 5 g
Shock Direction: B1 5 g
Shock Direction: B2 5 g
Shock Direction: C1 5 g
Shock Direction: C2 5 g
Shock Direction: A 5 g
Shock Direction: B1 5 g
Shock Direction: B2 5 g
Shock Direction: C1 5 g
Shock Direction: C2 5 g

Certificates and Declarations

BV Certificate:
Declaration of Conformity - UKCA:
DNV Certificate:
GL Certificate:
LOVAG Certificate:
LR Certificate:
RINA Certificate:
RMRS Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
203 mm
Package Level 1 Depth / Length:
245 mm
Package Level 1 Height:
188 mm
Package Level 1 Gross Weight:
6.1 kg
Package Level 1 EAN:
7320500203323

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4755 >> Contactors
E-Number (Finland):
3709329
E-Number (Norway):
4115176
ACH550-UH-078A-4 ABB
ABB ACH550-UH-078A-4 ABB
Sale price €4.970,95
Only 6 units left

AC DRIVE, 550 SERIES, 3 PHASE, 380-480 V AC, 50/60 HZ, 77 A, 60 HP

XPSAK361144 Schneider
Schneider XPSAK361144 Schneider
Sale price €658,95
Only 3 units left

This XPSAK safety module monitors emergency shutdown pushbuttons, limit switches, light curtains and safety mats/edges. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It can also be used for electrical monitoring of switches activated by protection devices, with optional selection of synchronisation time between signals, monitoring of 4-wire sensing mats or edges. And monitoring of type 4 light curtains conforming to EN/IEC 61496-1 which have solid-state safety outputs with test function (light curtains XUSL). It is compatible with emergency push buttons, limit switches, safety light curtains and safety mats/edges, the 4 most common safety sensors in the industry. It has additional solid-state output for communication with PLCs about safety status of your process.

Main

Characteristic Value(s)
Range of product Preventa Safety automation
Product or component type Preventa safety module
Safety module name XPSAK
Safety module application For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
Function of module Monitoring of electro-sensitive protection equipment (ESPE)
Monitoring of a movable guard associated with 2 switches and automatic start
Monitoring of a movable guard
Multiple emergency stop monitoring 2-channel wiring
Emergency stop with 2 NC contacts monitoring 2-channel wiring
Sensing mat and edges monitoring
Proximity sensor monitoring
Emergency stop monitoring 1-channel wiring
Safety level Can reach PL e/category 4 conforming to EN/ISO 13849-1
Can reach SILCL 3 conforming to EN/IEC 62061
Safety reliability data DC > 99 % conforming to EN/ISO 13849-1
MTTFd = 154.5 years conforming to EN/ISO 13849-1
PFHd = 7.39E-9 1/h conforming to EN/IEC 62061
Type of start Configurable
Connections - terminals Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type Relay instantaneous opening, 3 NO circuit(s), volt-free
Number of additional circuits 1 NC + 4 solid state outputs
[Us] rated supply voltage 110 V AC - 15...10 %
24 V DC - 15...10 %

Complementary

Characteristic Value(s)
Synchronisation time between inputs Unlimited (manual start)
2 or 4 s depending of wiring (automatic start)
Supply frequency 50/60 Hz
Maximum power consumption in VA 6 VA AC
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V DC
Maximum line resistance 28 Ohm
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
Output thermal current 6 A per relay for relay output
[Ith] conventional free air thermal current 18 A
Associated fuse rating 4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA for relay output
Minimum output voltage 17 V for relay output
Maximum response time on input open 40 ms
[Ui] rated insulation voltage 300 V (pollution degree 2) conforming to IEC 60947-5-1
300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to IEC 60947-5-1
4 kV overvoltage category III conforming to DIN VDE 0110 part 1
Local signalling 4 LEDs
Current consumption 30 mA at 24 V AC on power supply
Mounting support 35 mm symmetrical DIN rail
Product weight 0.4 kg
Yaskawa New Stock Image
Yaskawa SGM-01V312 Yaskawa
Sale price €452,95
Only 6 units left

The AC servo motor model SGM01V312 stands out for its efficiency and precision in control systems, characterized by its 100 W power capacity and 200 V operating voltage. This unit generates a torque of 0.318 NM and achieves a top speed of 3000 revolutions per minute, ensuring optimal performance for complex machinery requirements. Designed to meet the rigorous demands of servo applications, this motor exemplifies versatility and consistent performance.

GV3P73 Schneider Electric
Schneider GV3P73 Schneider Electric
Sale price €175,95
Only 5 units left

Motor circuit breaker, TeSys GV3, 3P, 62-73 A, thermal magnetic, EverLink terminals

2938811 Phoenix Contact - QUINT-PS-100-240AC/12DC/10

DIN rail power supply unit, primary-switched mode, 1-phase, output: 12 V DC / 10 A

6SE6440-2UC17-5AA1 Siemens
Siemens 6SE6440-2UC17-5AA1 Siemens
Sale price €300,95
Only 5 units left
Product
Article Number (Market Facing Number) 6SE64402UC175AA1 | 6SE64402UC175AA1
Product Description
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
Additional Product Information
EAN 4019169450089
UPC 783087635265
Commodity Code 85044085
LKZ_FDB/ CatalogID DA51-D
Product Group 9848
Group Code R2S3
Country of origin Great Britain
SCIP number 43c43a6f-4cee-496c-9c3c-28bd229c4a9b
Delivery information
Net Weight (lb) 2.866 lb
Package size unit of measure Inch
Packaging Quantity 1
2982090 Phoenix Contact - Reversing load relay - ELR W1/ 6-24DC

Electronic reversing load relay, for controlling DC motors, with LED display and protective circuit, output: 10 - 30 V�DC/6�A with a switch-over time of 80�ms

Schneider New Stock Image
Schneider XKBA11330 Schneider
Sale price €702,95
In stock, 11 units

Main

Characteristic Value(s)
Range of product Harmony XK
Product or component type Complete joystick controller
Product specific application Light hoisting applications

Complementary

Characteristic Value(s)
Device short name XKB
Bezel material Metal
Fixing collar material Metal
Sale per indivisible quantity 1
Protective treatment TC
Ambient air temperature for storage -40…70 °C
Ambient air temperature for operation -20…70 °C
Overvoltage category Class I conforming to IEC 61140
IP degree of protection IP54 conforming to IEC 60529
Standards UL 508
EN/IEC 60947-5-1
CSA C22.2 No 14
Product certifications CCC
CSA
UL
RRS
Contact code designation A300
Q300
Operator position information All positions
Operator profile Standard handle
Notch per direction 1…3 notches at 12°-20°-28° for each direction
Mechanical durability 1000000 cycles
Vibration resistance 6 gn (f= 1…70 Hz) conforming to IEC 60068-2-6
Shock resistance 20 gn (duration = 11 ms) conforming to IEC 60068-2-6
Connections - terminals Captive screw clamp terminals, <= 2 x 1.5 mm² with cable end
Captive screw clamp terminals, <= 1 x 2.5 mm² without cable end
Captive screw clamp terminals, >= 1 x 0.5 mm²
Short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal current 10 A conforming to EN/IEC 60947-5-1
10 A conforming to CSA C22.2 No 14
10 A conforming to UL 508
[Ui] rated insulation voltage 500 V (pollution degree 3) conforming to IEC 60947-1
Compatibility code XKB
Keyence New Stock Image
Keyence LV-N11CP Keyence
Sale price €237,95
In stock, 11 units

Specifications

Model

LV-N11CP

Type

1 output

Output

PNP

Cable/connector

M8 connector

Main/Expansion unit

Main unit

I/O

Control outputs

1 output

External input

1 input

Monitor output

None

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Timer function

Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,
Timer duration selectable: 1 ms to 9,999 ms,
Maximum error against the setting value: ±10% max.

Control outputs

PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA)
(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
(Multiple connections) 1 output max: 20 mA or less

Response time

80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1

Monitor output

-

External input

Input time 2 ms (ON)/20 ms (OFF) or more*2

Number of interference
prevention units

Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,
Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3

Case size

H 32.6 mm 1.28" × W 9.8 mm 0.39" × L 78.7 mm 3.1"

Unit expansion

Up to 17 units can be connected in total (two-output type is treated as two units)

Protection circuit

Reverse polarity protection, Over-current protection, Surge absorber

Rating

Power voltage

24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS*4*5

Power
consumption

Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*6
Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*6
Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V)
*7

Environmental resistance

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)*8

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Cable

PVC

Case

Main unit and cover material: Polycarbonate

Weight

Approx. 20 g

*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected
*2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected.
*3 These numbers double when "DOUBLE" is selected.
*4 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
*5 To connect more than 9 units, the power voltage must be 20 V or more.
*6 Increases 30 mW (1 mA) for HIGH SPEED mode.
*7 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load.
Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.
(1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.
*8 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.
One or two more units connected: -20 to +55 °C -4 to 131 °F; 3 to 10 more units connected: -20 to +50 °C -4 to 122 °F; 11 to 16 more units connected: -20 to +45 °C -4 to 113 °F. When using 2-outputs, one unit is counted as two units.

Keyence New Stock Image
Keyence IG-028 Keyence
Sale price €852,95
In stock, 17 units

Specifications

Model

IG-028

Operation principle

CCD method

Light source

Wavelength

660 nm (Visible light semiconductor laser)

FDA

Class 1*1

IEC/JIS

Class 1

Mounting distance

0 to 1500 mm 59.06"

Measurement range

28 mm 1.10"

Sampling cycle

980 µs (When the number of times for averaging is set to [hsp]: 490 µs)

Minimum detectable object

High sensitivity mode

ø0.1 mm ø0.003" (Setting distance: 100 mm 3.94")*2

Standard mode

ø0.2 mm ø0.007" (Setting distance: 50 mm 1.97" or less),
ø0.5 mm ø0.02" (Setting distance: 500 mm 19.68")*2

Repeatability

5 µm 0.20 Mil (Setting distance: 100 mm 3.94")
10 µm 0.39 Mil (Setting distance: 500 mm 19.68")
80 µm 3.15 Mil (Setting distance: 1,000 mm 39.37")
140 µm 5.51 Mil (Setting distance: 1,500 mm 59.06")*3

Linearity

±0.1 % of F.S. (±28 µm ±1.10 Mil)*4

Temperature characteristics

±0.01 % of F.S./°C (±3 µm ±0.12 Mil/°C)*5

Operation indicator

Transmitter

Optical axis alignment indicator: Green LED, Power indicator: Green LED

Receiver

Optical axis alignment indicator: Green LED, Position monitor: Dual bar LED (Red, Green)

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp: 5,000 lux, Sunlight: 5,000 lux*6

Ambient temperature

-10 to +45 °C 14 to 113 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Case

Zinc die-cast (Lower case), PBT (Upper case), Polyarylate (PAR) (Display part), SUS304 (Metallic part)

Lens cover

Glass

Cable

PVC

Accessories

Transmitter × 1, Receiver × 1, Sensor head cables (2 m 6.56') × 2

Weight

Approx. 500 g (including supplied items)

*1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 When the measurement target object is measured at the center position of the setting distance. When the measurement mode is set to the glass edge mode, a glass edge of C0.1 mm 0.003" or more can be detected (Setting distance: 500 mm 19.69").
*3 When the light is shielded by half at the center position of the setting distance. Vibration width when the average number of times is set to 16 and sampling is performed for 30 seconds. (When the analog output is used, the margin of error of analog output is added.)
*4 When the setting distance is 100 mm 3.94" and light is shielded at 50 mm 1.96"position from the receiver. Margin of error to the ideal line.
*5 When the setting distance is 100 mm 3.94" and light is shielded by half at 50 mm 1.96" position from the receiver.
*6 Excluding when the average number of times is set to [hsp].

Keyence New Stock Image
Keyence FD-Q10C Keyence
Sale price €479,95
In stock, 11 units

Specifications

Model

FD-Q10C

Supported pipe diameter

1/4" (8 A), ø13 to ø16 (mm)
3/8" (10 A), ø16 to ø18 (mm)

Supported pipe materials

Metal pipe/Resin pipe*1

Supported fluids

Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1

Supported fluid temperature

0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2

Maximum rated flow

1/4" (8 A): 20 L/min, 5.2 G/min
3/8" (10 A): 30 L/min, 7.9 G/min

Zero cut flow rate

1.0 L/min (Default)*3

Display method

Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator

Display update cycle

Approx. 3 Hz

Display resolution

0.01/0.1/1 (Default : 0.1) (L/min)

Response time

0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s

Protection circuit

Power supply reverse connection protection, power supply surge protection,
each output short-circuit protection, each output surge protection

Repeatability

0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time))

Hysteresis

Variable

Integrated flow unit display

0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L)

Integrated flow data storage cycle

Save to memory every 10 seconds

Memory backup

EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)

Power I/O connector

M12 4-pin connector

Input/Output (Selectable)

Output (ch.1/ch.2)

Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used),
NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5

Analog output (ch.2)

4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5

External input (ch.2)

Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used),
short-circuit current 1.5 mA or less, input time 20 ms or more*5

Power supply

Power voltage

20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS

Current consumption

100 mA or less (Load current excluded)*6

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Sensor main unit

PPS/PES/PBT/SUS303/SUS304/SUSXM7

Sensor surface

Rubber

Mounting bracket

SUS304/PA/SUSXM7

Weight

Approx. 340 g (including mounting bracket)

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes)
*2 Contact KEYENCE when the temperature of the pipe is greater than 85°C 185°F
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range.
*5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO)
*6 When including the loads, please add 200 mA to this value.

Keyence New Stock Image
Keyence SL-T11R Keyence
Sale price €297,95
Only 5 units left

Specifications

Model

SL-T11R

Combined light curtain

SL-V Series

Output

FSD1、2

230 VAC/4 A, 30 VDC/2 A (Resistance load)
230 VAC/2 A (COSø = 0.3) (Inductive load)
30 VDC/1 A (COSø = 0.3) (Inductive load)*1

Life-span

Mechanical life: 10 million cycles or more/Electrical life: 0.1 million cycle or more*1

Response time (ms)

ON→OFF

+6 ms

OFF→ON

+15 ms

Approved standards

EMC

EMS

UL61496-1, IEC61496-1, EN61496-1

EMI

FCC Part15B Class A, ICES-003 Class A, EN55011 Class A

Safety

UL61496-1, IEC61496-1, EN61496-1 (Type 4 ESPE), ISO 13849-1: 2015 (Cat 4 PLe), UL508, EN50178

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

100 mA or less (at 24 VDC, SL-T11R alone)

Environmental resistance

Enclosure rating

IP20 (IEC60529), Set inside control panel with IP54 or more

Pollution degree

2

Overvoltage category

III

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Polycarbonate

Weight

Approx. 330 g

*1 For the specifications for the outputs other than FSD and for each input, refer to the SL-V Instruction Manual.

Keyence New Stock Image
Keyence SL-R11 Keyence
Sale price €493,95
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LCIDO9 Schneider
Sale price €85,95
In stock, 11 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed