ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
B
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
6 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
2 W
at Rated Operating Conditions per Pole 2 W
2 W
at Rated Operating Conditions per Pole 2 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210106
1664817
2100400
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
D
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
8 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 / 60 Hz
1.5 W
at Rated Operating Conditions per Pole 1.5 W
1.5 W
at Rated Operating Conditions per Pole 1.5 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
1664871
2100631
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
C
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
8 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
1.5 W
at Rated Operating Conditions per Pole 1.5 W
1.5 W
at Rated Operating Conditions per Pole 1.5 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210573
1664853
2100514
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
D
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
10 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 / 60 Hz
1.6 W
at Rated Operating Conditions per Pole 1.6 W
1.6 W
at Rated Operating Conditions per Pole 1.6 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
1664873
2100632
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
B
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
10 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
2.1 W
at Rated Operating Conditions per Pole 2.1 W
2.1 W
at Rated Operating Conditions per Pole 2.1 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210110
1664800
2100402
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
D
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
13 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 / 60 Hz
2.2 W
at Rated Operating Conditions per Pole 2.2 W
2.2 W
at Rated Operating Conditions per Pole 2.2 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
1664875
2100633
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
C
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
13 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
2.3 W
at Rated Operating Conditions per Pole 2.3 W
2.3 W
at Rated Operating Conditions per Pole 2.3 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210574
1664829
2100518
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
B
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
13 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
2.3 W
at Rated Operating Conditions per Pole 2.3 W
2.3 W
at Rated Operating Conditions per Pole 2.3 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210571
1664802
2100404
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
K
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
0.5 A
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
1.1 W
at Rated Operating Conditions per Pole 1.1 W
1.1 W
at Rated Operating Conditions per Pole 1.1 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y / 277 V AC
60 V DC
480Y / 277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210679
1664897
2100688
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
Z
acc. to IEC 60898-1 230 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
0.5 A
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
2.4 W
at Rated Operating Conditions per Pole 2.4 W
2.4 W
at Rated Operating Conditions per Pole 2.4 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y / 277 V AC
60 V DC
480Y / 277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210702
1665030
2100742
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
D
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
16 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 / 60 Hz
2.5 W
at Rated Operating Conditions per Pole 2.5 W
2.5 W
at Rated Operating Conditions per Pole 2.5 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
1664877
2100634
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
D
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
20 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 / 60 Hz
2.3 W
at Rated Operating Conditions per Pole 2.3 W
2.3 W
at Rated Operating Conditions per Pole 2.3 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
1664880
2100635
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
B
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
20 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 / 60 Hz
2.5 W
at Rated Operating Conditions per Pole 2.5 W
2.5 W
at Rated Operating Conditions per Pole 2.5 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210120
1664807
2100408
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
K
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
1 A
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
1.25 W
at Rated Operating Conditions per Pole 1.25 W
1.25 W
at Rated Operating Conditions per Pole 1.25 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y / 277 V AC
60 V DC
480Y / 277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210680
1664901
2100689
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
Z
acc. to IEC 60898-1 230 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
1 A
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
2.3 W
at Rated Operating Conditions per Pole 2.3 W
2.3 W
at Rated Operating Conditions per Pole 2.3 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y / 277 V AC
60 V DC
480Y / 277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210703
1665035
2100743
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
D
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
25 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 / 60 Hz
3.1 W
at Rated Operating Conditions per Pole 3.1 W
3.1 W
at Rated Operating Conditions per Pole 3.1 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
1664883
2100636
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
B
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
25 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
3.2 W
at Rated Operating Conditions per Pole 3.2 W
3.2 W
at Rated Operating Conditions per Pole 3.2 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210125
1664809
2100410
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
K
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
2 A
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
1.65 W
at Rated Operating Conditions per Pole 1.65 W
1.65 W
at Rated Operating Conditions per Pole 1.65 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y / 277 V AC
60 V DC
480Y / 277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210682
1664924
2100691
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
Z
acc. to IEC 60898-1 230 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
2 A
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
2.5 W
at Rated Operating Conditions per Pole 2.5 W
2.5 W
at Rated Operating Conditions per Pole 2.5 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y / 277 V AC
60 V DC
480Y / 277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210705
1665055
2100745
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
K
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
3 A
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
1.2 W
at Rated Operating Conditions per Pole 1.2 W
1.2 W
at Rated Operating Conditions per Pole 1.2 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y / 277 V AC
60 V DC
480Y / 277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210683
1664938
2100692
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
Z
acc. to IEC 60898-1 230 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
3 A
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
2.4 W
at Rated Operating Conditions per Pole 2.4 W
2.4 W
at Rated Operating Conditions per Pole 2.4 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y / 277 V AC
60 V DC
480Y / 277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210706
1665070
2100746
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
10000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
D
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
32 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 / 60 Hz
3.6 W
at Rated Operating Conditions per Pole 3.6 W
3.6 W
at Rated Operating Conditions per Pole 3.6 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
1664886
2100637
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Product Durability
Technical
50 / 60 Hz - 1 min 2 kV
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 20 kA
(230 V AC) 10 kA
(24 V DC) 20 kA
(60 V DC) 10 kA
(230 V) 10 kA
(400 V) 10 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
(133 V AC) 15 kA
(230 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
10000 AC cycle
20000 cycle
1
1P
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
B
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
acc. to IEC 60898-1 230/400 V AC
acc. to IEC 60947-2 230 V AC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum (Incl. Tolerance) 72 V DC
Minimum 12 V AC
Minimum 12 V DC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC/DC
32 A
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 / 400 V AC) 6 kA
(230 V) 10 kA
(400 V) 10 kA
(230 V) 10 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
3.7 W
at Rated Operating Conditions per Pole 3.7 W
3.7 W
at Rated Operating Conditions per Pole 3.7 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
60 V DC
480Y/277 V AC
60 V DC
480Y/277 V AC
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
(277 V AC) 6 kA
(60 V DC) 10 kA
(120 V) 10 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20240821
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
30 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
1.0
17.5 mm
88 mm
69 mm
0.125 kg
0.125 kg
69 mm
Engineering
Ordering
carton 10 piece
1.295 kg
3210132
1664811
2100412
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
ABB industrial PLCs are the ultimate solution for modern businesses striving for efficiency, productivity, and unparalleled control. As a business owner, you know that every operation demands precision, consistency, and absolute reliability. That's why the brand has developed a powerful tool that will revolutionize the way you manage your industrial processes. With ABB PLCs, you'll unlock a world of limitless possibilities. Their cutting-edge technology ensures seamless integration, allowing you to effortlessly streamline your manufacturing operations. Say goodbye to the days of complicated manual controls and labor-intensive processes—these industrial PLC systems are here to simplify your operations and supercharge your business.
We at PLC Direct understand that you can’t rely on just any automation equipment to keep your facilities operating at their best. That’s why we make sure that we only feature products from top brands in our inventory. Whether you’re running a current ABB PLC model or an older one, we carry compatible replacements and parts to keep things moving smoothly. Shop with us today to find the perfect industrial PLC for your needs.
We at PLC Direct understand that you can’t rely on just any automation equipment to keep your facilities operating at their best. That’s why we make sure that we only feature products from top brands in our inventory. Whether you’re running a current ABB PLC model or an older one, we carry compatible replacements and parts to keep things moving smoothly. Shop with us today to find the perfect industrial PLC for your needs.