3P MMP 2.5-4.0A RANGE
Manual changeover switch, front operation, mounting on DIN rail or plate, IO-II function type OT80F4C 80A
Manual changeover switch, front operation, mounting on DIN rail or plate, IO-II function type OT80F3C 80A
Manual changeover switch, front operation, mounting on DIN rail or plate, IO-II function type OT63F4C 63A
OT125F8 SWITCH-DISCONNECTOR
EH04-20N Auxiliary Contact
EH04-11N Auxiliary Contact
NF40E-11 24-60V50/60HZ 20-60VDC Contactor Relay
NF31E-11 24-60V50/60HZ 20-60VDC Contactor Relay
NF22E-11 24-60V50/60HZ 20-60VDC Contactor Relay
The TF42-5.7 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
TF42-4.2 Thermal Overload Relay 3.1 ... 4.2 A
TF42-3.1 Thermal Overload Relay 2.3 ... 3.1 A. The TF42-3.1 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure.
TF42-1.7 Thermal Overload Relay 1.3 ... 1.7 A
TF42-1.3 Thermal Overload Relay
TF42-1.0 Thermal Overload Relay 0.74 ... 1.0 A
TEF4-OFF is a frontal electronic timer used to realize the timing function and allow a compact solution in the cabinet compared to separate timers. TEF4 electronic timers are front-mounted and locked on AF, AFC contactors or NF, NFC contactor relays. A mechanical indicator allows to show the state of the contactor. TEF4 electronic timers are supplied by a direct plug-in parallel connection to the coil terminals A1 - A2 of the contactor or contactor relay. A varistor is integrated on the timer to offer a built-in protection against surges in the contactor coil. The TEF4 is available for a wide control voltage range 24...240 V AC/DC. TEF4 allow time-delayed functions up to 100 s in 3 distinct time ranges, independently of the control system. The time delay ranges are selected by a switch and the time delay can be adjusted by means of a rotary switch. The timing function of TEF4-OFF is activated by opening the device on which the timer is mounted. The OFF-delay version operates without additional control supply.
OT63ML4 SWITCH-DISCONNECTOR
Switch-disconnector
Switch-disconnector
OT125M3 SWITCH-DISCONNECTOR
ENCLOSURES 1 HOLE