TM3DQ8U Schneider
Schneider TM3DQ8U Schneider
Sale price 1 108 kr
Only 8 units left

This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262. The discrete output module provides 8 transistor outputs with sink (negative)logic. It is an output module with an output voltage of 24V DC and a current consumption of 20mA at 24V DC via bus connector. This product is capable of controlling variable speed drives or any device equipped with a current or voltage input. There is an insulation between output and internal logic at 2300V AC, outputs at 750V AC, output groups at 1500V AC. It is furnished with removable screw terminal for electrical connection with 5.08mm pitch adjustment for outputs. It is an IP20 rated product. Its dimensions are 27.4mm (Width) x 84.6mm (Depth) x 90mm (Height). It weighs 0.76kg. This product is certified by CE, CULus and C-Tick. It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards. This module is compatible with Modicon M241, Modicon M251 and Modicon M221 logic controller. It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount. Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism. A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers. Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.

Main

Characteristic Value(s)
Range of Product Modicon TM3
Product or Component Type Discrete output module
Range Compatibility Modicon M241
Modicon M251
Modicon M221
Modicon M262
Discrete output type Transistor
Discrete output number 8
Discrete output logic Negative logic (sink)
Discrete output voltage 24 V DC transistor output
Discrete output current 50 mA transistor output

Complementary

Characteristic Value(s)
Discrete I/O number 8
Current consumption 5 mA 5 V DC via bus connector at state off)
0 mA 24 V DC via bus connector at state off)
20 mA 24 V DC via bus connector at state on)
10 mA 5 V DC via bus connector at state on)
Response time 450 µs (turn-on)
450 µs (turn-off)
Maximum leakage current 0.1 mA transistor output
Maximum voltage drop <0.4 V
Local signalling 1 LED per channel (green) for output status
Electrical connection 11 x 2.5 mm² removable screw terminal block pitch 5.08 mm for outputs
Maximum cable distance between devices Unshielded cable <98.4 ft (30 m) transistor output
Insulation Between output and internal logic 500 V AC
Non-insulated between outputs
Marking CE
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Height 3.5 in (90 mm)
Depth 3.3 in (84.6 mm)
Width 1.08 in (27.4 mm)
Product Weight 1.68 lb(US) (0.76 kg)
TM3DQ8UG Schneider
Schneider TM3DQ8UG Schneider
Sale price0 kr
Sold Out

Main

Characteristic Value(s)
Range of Product Modicon TM3
Product or Component Type Discrete output module
Range Compatibility Modicon M241
Modicon M251
Modicon M221
Modicon M262
Discrete output type Transistor
Discrete output number 8
Discrete output logic Negative logic (sink)
Discrete output voltage 24 V DC transistor output
Discrete output current 50 mA transistor output

Complementary

Characteristic Value(s)
Discrete I/O number 8
Current consumption 5 mA 5 V DC via bus connector at state off)
0 mA 24 V DC via bus connector at state off)
20 mA 24 V DC via bus connector at state on)
10 mA 5 V DC via bus connector at state on)
Response time 450 µs (turn-on)
450 µs (turn-off)
Maximum leakage current 0.1 mA transistor output
Maximum voltage drop <0.4 V
Local signalling 1 LED per channel (green) for output status
Electrical connection 11 x 2.5 mm² removable spring terminal block pitch 5.08 mm for outputs
Maximum cable distance between devices Unshielded cable <98.4 ft (30 m) transistor output
Insulation Between output and internal logic 500 V AC
Non-insulated between outputs
Marking CE
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Height 3.5 in (90 mm)
Depth 3.3 in (84.6 mm)
Width 1.08 in (27.4 mm)
Product Weight 1.68 lb(US) (0.76 kg)
TM3SAC5R Schneider
Schneider TM3SAC5R Schneider
Sale price 3 422 kr
Only 1 unit left

This TM3 safety expansion module monitors emergency shutdown pushbuttons and limit switches to conform to PLd / Category 3. It meets the requirements of PL d/Category 3 conforming to EN/ISO 13849-1 and SILCL 2 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability.

Main

Characteristic Value(s)
Range of Product Modicon TM3 Safety
Product or Component Type Safety module
Device short name TM3SAC
Safety module application For emergency stop and switch monitoring
Function of module Emergency stop monitoring 1-channel wiring
Emergency stop monitoring 2-channel wiring
Monitoring of a movable guard with 2 switches and automatic start
Safety level Can reach PL d/category 3 ISO 13849-1 2008
Can reach PL d/category 3 ISO 13849-2 2012
Can reach SILCL 2 IEC 62061 2005
Can reach SIL 2 IEC 61508 2010

Complementary

Characteristic Value(s)
Safety reliability data DC = 95 % ISO 13849-1
PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A
PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A
MTTFd = 500 years ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A
MTTFd = 85 years ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A
SFF = 95 % IEC 61508-1
HFT = 1 IEC 61508-1
Type = A IEC 61508-1
Synchronisation time between inputs Unlimited
Connections - terminals Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.5 mm² flexible without cable end other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.75 mm² solid without cable end other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 0.34 mm² flexible with cable end, without bezel other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.5 mm² flexible with cable end, with double bezel other terminals
Output type Relay instantaneous opening, 3 NO, potential free
Number of safety circuits 3 NO relay instantaneous opening
Maximum switching voltage 230 V AC-15 50 Hz relay instantaneous opening)
24 V DC-13 relay instantaneous opening)
[Us] rated supply voltage 24 V - 15...20 % DC
Power consumption in W 0.2 W 5 V DC
3.6 W 24 V DC
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V DC
Maximum cable distance between devices 98.4 ft (30 m)
Breaking capacity 360 VA holding AC-15 B300 relay output
3600 VA inrush AC-15 B300 relay output
Breaking capacity 4 A 24 V 50 ms DC-13 relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 18 A
Associated fuse rating 4 A gG or gL relay output IEC 60947-5-1
6 A fast blow relay output IEC 60947-5-1
Minimum output current 10 mA relay output
Output voltage 10 V relay output
Maximum response time on input open 40 ms
[Ui] rated insulation voltage 300 V 2)IEC 60647-5-1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60647-5-1
Current consumption 100 mA 24 V DC external supply at state on)
Local signalling 6 LEDs (green/red) for user
Electrical Connection Screw terminal
Standards ISO 13849-1:2008
ISO 13849-2:2012
IEC 62061:2005
IEC 61508:2010
IEC 60947-5-1:2010
IEC 61131-2:2007
IEC 60204-1:2005
IEC 60204-1:2009/A1
IEC 61010-1:2010
EN 50581:2012
Product Certifications TÜV
CSA 61010-2-201 (pending)
CSA Haz Loc Class 1 Division 2 (pending)
RCM
ANSI Haz Loc Class 1 Division 2 (pending)
EAC
UL 61010-2-201
Marking EFUP 10
RCM
CSA
UL
TÜV
CE
EAC
Electromagnetic compatibility Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2
Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3
Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8
Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5
Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6
Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to IEC 55011
Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to IEC 55011
Mounting support Top hat type TH35-7.5 rail IEC 60715
Top hat type TH35-15 rail IEC 60715
wall mount using attached fasteners
Height 3.7 in (94 mm)
Depth 2.9 in (73 mm)
Width 1.7 in (43.7 mm)
Product Weight 0.42 lb(US) (0.19 kg)
TM3SAC5RG Schneider
Schneider TM3SAC5RG Schneider
Sale price 7 329 kr
Only 2 units left

Safety Module FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

TM3SAF5R Schneider
Schneider TM3SAF5R Schneider
Sale price 5 727 kr
Only 2 units left

This TM3 safety expansion module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of PL e/Category 4 conforming to EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability.

Main

Characteristic Value(s)
Range of Product Modicon TM3 Safety
Product or Component Type Safety module
Device short name TM3SAF
Safety module application For emergency stop and switch monitoring
Function of module Emergency stop monitoring 1-channel wiring
Emergency stop monitoring 2-channel wiring
Monitoring of a movable guard with 2 switches and automatic start
Safety level Can reach PL e/category 4 ISO 13849-1 2008
Can reach PL e/category 4 ISO 13849-2 2012
Can reach SILCL 3 IEC 62061 2005
Can reach SIL 3 IEC 61508 2010

Complementary

Characteristic Value(s)
Safety reliability data DC = 95 % ISO 13849-1
PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A
PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A
MTTFd = 500 years ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A
MTTFd = 85 years ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A
SFF = 95 % IEC 61508-1
HFT = 1 IEC 61508-1
Type = A IEC 61508-1
Synchronisation time between inputs Unlimited
Connections - terminals Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.5 mm² flexible without cable end other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.75 mm² solid without cable end other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 0.34 mm² flexible with cable end, without bezel other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.5 mm² flexible with cable end, with double bezel other terminals
Output type Relay instantaneous opening, 3 NO, potential free
Number of safety circuits 3 NO relay instantaneous opening
Maximum switching voltage 230 V AC-15 50 Hz relay instantaneous opening)
24 V DC-13 relay instantaneous opening)
[Us] rated supply voltage 24 V - 15...20 % DC
Power consumption in W 0.2 W 5 V DC
3.6 W 24 V DC
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V DC
Maximum cable distance between devices 98.4 ft (30 m)
Breaking capacity 360 VA holding AC-15 B300 relay output
3600 VA inrush AC-15 B300 relay output
Breaking capacity 4 A 24 V 50 ms DC-13 relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 18 A
Associated fuse rating 4 A gG or gL relay output IEC 60947-5-1
6 A fast blow relay output IEC 60947-5-1
Minimum output current 10 mA relay output
Output voltage 10 V relay output
Maximum response time on input open 40 ms
[Ui] rated insulation voltage 300 V 2)IEC 60647-5-1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60647-5-1
Current consumption 100 mA 24 V DC external supply
Local signalling 8 LEDs (green/red) for user
Electrical Connection Screw terminal
Standards ISO 13849-1:2008
ISO 13849-2:2012
IEC 62061:2005
IEC 61508:2010
IEC 60947-5-1:2010
IEC 61131-2:2007
IEC 60204-1:2005
IEC 60204-1:2009/A1
IEC 61010-1:2010
EN 50581:2012
Product Certifications EAC
CSA Haz Loc Class 1 Division 2 (pending)
RCM
TÜV
UL 61010-2-201
CSA 61010-2-201 (pending)
ANSI Haz Loc Class 1 Division 2 (pending)
Marking CE
UL
EFUP 10
EAC
RCM
TÜV
CSA
Electromagnetic compatibility Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2
Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3
Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8
Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5
Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6
Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to IEC 55011
Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to IEC 55011
Mounting support Top hat type TH35-7.5 rail IEC 60715
Top hat type TH35-15 rail IEC 60715
wall mount using attached fasteners
Height 3.7 in (94 mm)
Depth 2.9 in (73 mm)
Width 1.7 in (43.7 mm)
Product Weight 0.42 lb(US) (0.19 kg)
TM3SAF5RG Schneider
Schneider TM3SAF5RG Schneider
Sale price0 kr
Sold Out

Safety Module FOR PLC TM2xx, 1 FUNCTION, CAT4, SPRING TERMINALS

TM3SAFL5R Schneider
Schneider TM3SAFL5R Schneider
Sale price 4 823 kr
Only 1 unit left

This TM3 safety expansion module monitors emergency shutdown pushbuttons, limit switches and light curtains to conform to PLd / Category 3. It meets the requirements of PL d/Category 3 conforming to EN/ISO 13849-1 and SILCL 2 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It is compatible with emergency push buttons, limit switches and safety light curtains, the 3 most common safety sensors in the industry.

Main

Characteristic Value(s)
Range of Product Modicon TM3 Safety
Product or Component Type Safety module
Device short name TM3SAFL
Safety module application For emergency stop, switch and safety light curtain monitoring
Function of module Emergency stop monitoring 2-channel wiring
Monitoring of a movable guard with 2 switches and automatic start
Monitoring of a movable guard
Multiple emergency stop monitoring 2-channel wiring
Proximity sensor monitoring PNP/PNP
Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP
Safety level Can reach PL d/category 3 ISO 13849-1 2008
Can reach PL d/category 3 ISO 13849-2 2012
Can reach SILCL 2 IEC 62061 2005
Can reach SIL 2 IEC 61508 2010

Complementary

Characteristic Value(s)
Safety reliability data DC = 95 % ISO 13849-1
PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A
PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A
MTTFd = 500 years ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A
MTTFd = 85 years ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A
SFF = 95 % IEC 61508-1
HFT = 1 IEC 61508-1
Type = A IEC 61508-1
Synchronisation time between inputs Unlimited
Connections - terminals Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.5 mm² flexible without cable end other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.75 mm² solid without cable end other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 0.34 mm² flexible with cable end, without bezel other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.5 mm² flexible with cable end, with double bezel other terminals
Output type Relay instantaneous opening, 3 NO, potential free
Number of safety circuits 3 NO relay instantaneous opening
Maximum switching voltage 230 V AC-15 50 Hz relay instantaneous opening)
24 V DC-13 relay instantaneous opening)
[Us] rated supply voltage 24 V - 15...20 % DC
Power consumption in W 0.2 W 5 V DC
3.6 W 24 V DC
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V DC
Maximum cable distance between devices 98.4 ft (30 m)
Breaking capacity 360 VA holding AC-15 B300 relay output
3600 VA inrush AC-15 B300 relay output
Breaking capacity 4 A 24 V 50 ms DC-13 relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 18 A
Associated fuse rating 4 A gG or gL relay output IEC 60947-5-1
6 A fast blow relay output IEC 60947-5-1
Minimum output current 10 mA relay output
Output voltage 10 V relay output
Maximum response time on input open 40 ms
[Ui] rated insulation voltage 300 V 2)IEC 60647-5-1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60647-5-1
Current consumption 100 mA 24 V DC external supply
Local signalling 8 LEDs (green/red) for user
Electrical Connection Screw terminal
Product compatibility Safety light curtains EN/IEC 61496-1 (type 4)
Standards ISO 13849-1:2008
ISO 13849-2:2012
IEC 62061:2005
IEC 61508:2010
IEC 60947-5-1:2010
IEC 61131-2:2007
IEC 60204-1:2005
IEC 60204-1:2009/A1
IEC 61010-1:2010
EN 50581:2012
Product Certifications TÜV
RCM
ANSI Haz Loc Class 1 Division 2 (pending)
CSA Haz Loc Class 1 Division 2 (pending)
EAC
CSA 61010-2-201 (pending)
UL 61010-2-201
Marking CE
EFUP 10
UL
CSA
EAC
RCM
TÜV
Electromagnetic compatibility Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2
Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3
Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8
Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5
Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6
Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to IEC 55011
Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to IEC 55011
Mounting support Top hat type TH35-7.5 rail IEC 60715
Top hat type TH35-15 rail IEC 60715
wall mount using attached fasteners
Height 3.7 in (94 mm)
Depth 2.9 in (73 mm)
Width 1.7 in (43.7 mm)
Product Weight 0.42 lb(US) (0.19 kg)
TM3SAFL5RG Schneider
Schneider TM3SAFL5RG Schneider
Sale price 8 584 kr
Only 1 unit left

This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262. The safety module provides 3 normally opened contacts and unlimited synchronisation time between inputs. It is a safety module with a rated supply voltage of 24V DC, an external supply current consumption of 100mA at 24V DC on power supply and a power consumption 0.2W at 5V DC, 3.6W at 24V DC. The main functions of this module are emergency stop, movable guard, multiple emergency stop, proximity sensor and electro-sensitive protection equipment (ESPE) monitoring. It is furnished with spring terminal for electrical connection. It is an IP20 rated product. Its dimensions are 43.7mm (Width) x 73mm (Depth) x 94mm (Height). It weighs 0.19kg. It is suitable for emergency stop, switch and safety light curtain monitoring applications. This product is certified by RCM, CSA, UL, TÜV, ANSI Haz Loc Class 1 Division 2, EAC. It supports wall mount using attached fasteners. Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism. A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers. Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.

Main

Characteristic Value(s)
Range of Product Modicon TM3 Safety
Product or Component Type Safety module
Device short name TM3SAFL
Safety module application For emergency stop, switch and safety light curtain monitoring
Function of module Emergency stop monitoring 2-channel wiring
Monitoring of a movable guard with 2 switches and automatic start
Monitoring of a movable guard
Multiple emergency stop monitoring 2-channel wiring
Proximity sensor monitoring PNP/PNP
Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP
Safety level Can reach PL d/category 3 ISO 13849-1 2008
Can reach PL d/category 3 ISO 13849-2 2012
Can reach SILCL 2 IEC 62061 2005
Can reach SIL 2 IEC 61508 2010

Complementary

Characteristic Value(s)
Safety reliability data DC = 95 % ISO 13849-1
PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A
PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A
MTTFd = 500 years ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A
MTTFd = 85 years ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A
SFF = 95 % IEC 61508-1
HFT = 1 IEC 61508-1
Type = A IEC 61508-1
Synchronisation time between inputs Unlimited
Connections - terminals Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals
Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals
Captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals
Captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
Output type Relay instantaneous opening, 3 NO, potential free
Number of safety circuits 3 NO relay instantaneous opening
Maximum switching voltage 230 V AC-15 50 Hz relay instantaneous opening)
24 V DC-13 relay instantaneous opening)
[Us] rated supply voltage 24 V - 15...20 % DC
Power consumption in W 0.2 W 5 V DC
3.6 W 24 V DC
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V DC
Maximum cable distance between devices 98.4 ft (30 m)
Breaking capacity 360 VA holding AC-15 B300 relay output
3600 VA inrush AC-15 B300 relay output
Breaking capacity 4 A 24 V 50 ms DC-13 relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 18 A
Associated fuse rating 4 A gG or gL relay output IEC 60947-5-1
6 A fast blow relay output IEC 60947-5-1
Minimum output current 10 mA relay output
Output voltage 10 V relay output
Maximum response time on input open 40 ms
[Ui] rated insulation voltage 300 V 2)IEC 60647-5-1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60647-5-1
Current consumption 100 mA 24 V DC external supply
Local signalling 8 LEDs (green/red) for user
Electrical Connection Spring terminal
Product compatibility Safety light curtains EN/IEC 61496-1 (type 4)
Standards ISO 13849-1:2008
ISO 13849-2:2012
IEC 62061:2005
IEC 61508:2010
IEC 60947-5-1:2010
IEC 61131-2:2007
IEC 60204-1:2005
IEC 60204-1:2009/A1
IEC 61010-1:2010
EN 50581:2012
Product Certifications CSA 61010-2-201 (pending)
RCM
UL 61010-2-201
EAC
ANSI Haz Loc Class 1 Division 2 (pending)
CSA Haz Loc Class 1 Division 2 (pending)
TÜV
Marking RCM
UL
CSA
EAC
CE
TÜV
EFUP 10
Electromagnetic compatibility Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2
Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3
Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8
Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5
Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6
Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to IEC 55011
Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to IEC 55011
Mounting support Top hat type TH35-7.5 rail IEC 60715
Top hat type TH35-15 rail IEC 60715
wall mount using attached fasteners
Height 3.7 in (94 mm)
Depth 2.9 in (73 mm)
Width 1.7 in (43.7 mm)
Product Weight 0.42 lb(US) (0.19 kg)
TM3SAK6R Schneider
Schneider TM3SAK6R Schneider
Sale price 4 530 kr
Only 1 unit left

Safety module, Modicon TM3 Safety, 3 Function, Cat 4 PL e/SIL CL3 (screw) 24 VDC

TM3SAK6RG Schneider
Schneider TM3SAK6RG Schneider
Sale price0 kr
Sold Out

This TM3 safety expansion module monitors emergency shutdown pushbuttons, limit switches, light curtains and safety mats/edges. It meets the requirements of PL e/Category 4 conforming to EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It is compatible with emergency push buttons, limit switches, safety light curtains and safety mats/edges, the 4 most common safety sensors in the industry. It has spring terminals for fast and reliable wiring of safety circuits.

Main

Characteristic Value(s)
Range of Product Modicon TM3 Safety
Product or Component Type Safety module
Device short name TM3SAK
Safety module application For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
Function of module Emergency stop monitoring 1-channel wiring
Emergency stop monitoring 2-channel wiring
Monitoring of a movable guard with 2 switches and automatic start
Monitoring of a movable guard
Multiple emergency stop monitoring 2-channel wiring
Proximity sensor monitoring PNP/PNP
Proximity sensor monitoring PNP/NPN
Sensing mat and edges monitoring
Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP
Monitoring of electro-sensitive protection equipment (ESPE) PNP/NPN
Safety level Can reach PL e/category 4 ISO 13849-1 2008
Can reach PL e/category 4 ISO 13849-2 2012
Can reach SILCL 3 IEC 62061 2005
Can reach SIL 3 IEC 61508 2010

Complementary

Characteristic Value(s)
Safety reliability data DC = 95 % ISO 13849-1
PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A
PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A
MTTFd = 500 years ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A
MTTFd = 85 years ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A
SFF = 95 % IEC 61508-1
HFT = 1 IEC 61508-1
Type = A IEC 61508-1
Synchronisation time between inputs Unlimited
2 or 4 s depending of wiring configurable by software
Connections - terminals Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34
Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals
Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals
Captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals
Captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
Output type Relay instantaneous opening, 3 NO, potential free
Number of safety circuits 3 NO relay instantaneous opening
Maximum switching voltage 230 V AC-15 50 Hz relay instantaneous opening)
24 V DC-13 relay instantaneous opening)
[Us] rated supply voltage 24 V - 15...20 % DC
Power consumption in W 0.2 W 5 V DC
3.6 W 24 V DC
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V DC
Maximum cable distance between devices 98.4 ft (30 m)
Breaking capacity 360 VA holding AC-15 B300 relay output
3600 VA inrush AC-15 B300 relay output
Breaking capacity 4 A 24 V 50 ms DC-13 relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 18 A
Associated fuse rating 4 A gG or gL relay output IEC 60947-5-1
6 A fast blow relay output IEC 60947-5-1
Minimum output current 10 mA relay output
Output voltage 10 V relay output
Maximum response time on input open 40 ms
[Ui] rated insulation voltage 300 V 2)IEC 60647-5-1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60647-5-1
Current consumption 100 mA 24 V DC external supply
Local signalling 8 LEDs (green/red) for user
Electrical Connection Spring terminal
Product compatibility Safety light curtains EN/IEC 61496-1 (type 4)
Sensing mat/edges EN 1760-1
Standards ISO 13849-1:2008
ISO 13849-2:2012
IEC 62061:2005
IEC 61508:2010
IEC 60947-5-1:2010
IEC 61131-2:2007
IEC 60204-1:2005
IEC 60204-1:2009/A1
IEC 61010-1:2010
EN 50581:2012
Product Certifications CSA 61010-2-201 (pending)
TÜV
CSA Haz Loc Class 1 Division 2 (pending)
EAC
RCM
UL 61010-2-201
ANSI Haz Loc Class 1 Division 2 (pending)
Marking CSA
RCM
UL
EFUP 10
CE
TÜV
EAC
Electromagnetic compatibility Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2
Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3
Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8
Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5
Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6
Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to IEC 55011
Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to IEC 55011
Mounting support Top hat type TH35-7.5 rail IEC 60715
Top hat type TH35-15 rail IEC 60715
wall mount using attached fasteners
Height 3.7 in (94 mm)
Depth 2.9 in (73 mm)
Width 1.7 in (43.7 mm)
Product Weight 0.42 lb(US) (0.19 kg)
TM3TI4 Schneider
Schneider TM3TI4 Schneider
Sale price 1 617 kr
Only 10 units left

Analog input module, Modicon TM3, 4 / temperature inputs (screw) 24 VDC

TM3TI4D Schneider
Schneider TM3TI4D Schneider
Sale price 2 165 kr
Only 10 units left

Main

Characteristic Value(s)
Range of Product Modicon TM3
Product or Component Type Analog input module
Range Compatibility Modicon M221
Modicon M241
Modicon M251
Modicon M262
Analogue input number 4
Analogue input type thermocouple - 200...1000 °C thermocouple J
thermocouple - 200...1300 °C thermocouple K
thermocouple 0...1760 °C thermocouple R
thermocouple 0...1760 °C thermocouple S
thermocouple 0...1820 °C thermocouple B
thermocouple - 200...400 °C thermocouple T
thermocouple - 200...1300 °C thermocouple N
thermocouple - 200...800 °C thermocouple E
thermocouple 0...2315 °C thermocouple C

Complementary

Characteristic Value(s)
Analogue input resolution 16 bits
15 bits + sign
Permissible continuous overload 13 V voltage
40 mA current
Input impedance >= 1 MOhm thermocouple
LSB value 0.1 °C thermocouple
Conversion time 100 ms + 100 ms per channel + 1 controller cycle time thermocouple
Sampling duration 100 ms thermocouple
Absolute accuracy error +/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple C 0...2315 °C
+/- 6 °C at 77 °F (25 °C) for thermocouple R, S 0...200 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple R, S 200...1760 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple B 300...1820 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple K - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple K 0...1300 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple J - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple J 0...1000 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple E - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple E 0...800 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple T - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple T 0...400 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple N - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple N 0...1300 °C
Temperature Drift +/- 0.01 %FS/°C
Repeat accuracy +/-0.5 %FS
Non-linearity +/- 0.2 %FS
Cross talk <= 1 LSB
[Us] rated supply voltage 24 V DC
Supply voltage limits 20.4…28.8 V
Type of cable Twisted shielded pairs cable <98.4 ft (30 m) input
Current consumption 45 mA 5 V DC via bus connector
50 mA 5 V DC via bus connector
35 mA 24 V DC via external supply
40 mA 24 V DC via external supply
Local signalling 1 LED (green) for PWR
Electrical connection 10 x 1.5 mm² removable screw terminal block pitch 3.81 mm for inputs and supply
10 x 1.5 mm² removable screw terminal block pitch 3.81 mm for inputs
Insulation Between input and supply 1500 V AC
Between input and internal logic 500 V AC
Marking CE
Surge withstand 1 kV power supply common mode IEC 61000-4-5
0.5 kV power supply differential mode IEC 61000-4-5
1 kV input common mode IEC 61000-4-5
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Height 3.5 in (90 mm)
Depth 2.8 in (70 mm)
Width 0.9 in (23.6 mm)
Product Weight 0.24 lb(US) (0.11 kg)
TM3TI4DG Schneider
Schneider TM3TI4DG Schneider
Sale price 3 182 kr
Only 1 unit left

Main

Characteristic Value(s)
Range of Product Modicon TM3
Product or Component Type Analog input module
Range Compatibility Modicon M221
Modicon M241
Modicon M251
Modicon M262
Analogue input number 4
Analogue input type thermocouple - 200...1000 °C thermocouple J
thermocouple - 200...1300 °C thermocouple K
thermocouple 0...1760 °C thermocouple R
thermocouple 0...1760 °C thermocouple S
thermocouple 0...1820 °C thermocouple B
thermocouple - 200...400 °C thermocouple T
thermocouple - 200...1300 °C thermocouple N
thermocouple - 200...800 °C thermocouple E
thermocouple 0...2315 °C thermocouple C

Complementary

Characteristic Value(s)
Analogue input resolution 16 bits
15 bits + sign
Permissible continuous overload 13 V voltage
40 mA current
Input impedance >= 1 MOhm thermocouple
LSB value 0.1 °C thermocouple
Conversion time 100 ms + 100 ms per channel + 1 controller cycle time thermocouple
Sampling duration 100 ms thermocouple
Absolute accuracy error +/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple C 0...2315 °C
+/- 6 °C at 77 °F (25 °C) for thermocouple R, S 0...200 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple R, S 200...1760 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple B 300...1820 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple K - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple K 0...1300 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple J - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple J 0...1000 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple E - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple E 0...800 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple T - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple T 0...400 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple N - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple N 0...1300 °C
Temperature Drift +/- 0.01 %FS/°C
Repeat accuracy +/-0.5 %FS
Non-linearity +/- 0.2 %FS
Cross talk <= 1 LSB
[Us] rated supply voltage 24 V DC
Supply voltage limits 20.4…28.8 V
Type of cable Twisted shielded pairs cable <98.4 ft (30 m) input
Current consumption 45 mA 5 V DC via bus connector
50 mA 5 V DC via bus connector
35 mA 24 V DC via external supply
40 mA 24 V DC via external supply
Local signalling 1 LED (green) for PWR
Electrical connection 10 x 1.5 mm² removable spring terminal block pitch 3.81 mm for inputs and supply
10 x 1.5 mm² removable spring terminal block pitch 3.81 mm for inputs
Insulation Between input and supply 1500 V AC
Between input and internal logic 500 V AC
Marking CE
Surge withstand 1 kV power supply common mode IEC 61000-4-5
0.5 kV power supply differential mode IEC 61000-4-5
1 kV input common mode IEC 61000-4-5
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Height 3.5 in (90 mm)
Depth 2.8 in (70 mm)
Width 0.9 in (23.6 mm)
Product Weight 0.24 lb(US) (0.11 kg)
TM3TI4G Schneider
Schneider TM3TI4G Schneider
Sale price 2 101 kr
In stock, 11 units

Analog input module, Modicon TM3, 4 / temperature inputs (spring) 24 VDC

TM3TI8T Schneider Electric
Schneider TM3TI8T Schneider Electric
Sale price 2 553 kr
Only 7 units left

This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262. The analogue input module provides 8 inputs with 16bit and 15bit + sign resolution. It is an input module with a rated supply voltage of 24V DC and a current consumption of 30mA at 24V DC via external supply, 45mA/40mA at 5V DC via bus connector. This product is capable of controlling variable speed drives or any device equipped with a current or voltage input. There is an insulation between input and supply at 1500V AC, input and internal logic at 500V AC. It is furnished with removable screw terminal for electrical connection with pitch 3.81mm adjustment for inputs and supply. It is an IP20 rated product. Its dimensions are 23.6mm (Width) x 70mm (Depth) x 90mm (Height). It weighs 0.11kg. This product is certified by CE. It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards. This module is compatible with Modicon M262, Modicon M241, Modicon M251 and Modicon M221 logic controller. It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount. Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism. A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers. Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.

Main

Characteristic Value(s)
Range of Product Modicon TM3
Product or Component Type Analog input module
Range Compatibility Modicon M221
Modicon M241
Modicon M251
Modicon M262
Analogue input number 8
Analogue input type thermocouple - 200...1000 °C thermocouple J
thermocouple - 200...1300 °C thermocouple K
thermocouple 0...1760 °C thermocouple R
thermocouple 0...1760 °C thermocouple S
thermocouple 0...1820 °C thermocouple B
thermocouple - 200...400 °C thermocouple T
thermocouple - 200...1300 °C thermocouple N
thermocouple - 200...800 °C thermocouple E
thermocouple 0...2315 °C thermocouple C
NTC 10k thermistor -90...150 °C
PTC thermistor 100...10000 Ohm
thermocouple - 200...1000 °C

Complementary

Characteristic Value(s)
Analogue input resolution 16 bits
15 bits + sign
Input impedance >= 1 MOhm thermocouple
>= 1 MOhm temperature probe
>= 1 MOhm thermistor
LSB value 0.1 °C thermocouple
0.1 °C NTC
1 Ohm PTC/NTC
Conversion time 100 ms + 100 ms per channel + 1 controller cycle time
Sampling duration 100 ms
Absolute accuracy error +/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple C 0...2315 °C
+/- 6 °C at 77 °F (25 °C) for thermocouple R, S 0...200 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple R, S 200...1760 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple B 300...1820 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple K - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple K 0...1300 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple J - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple J 0...1000 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple E - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple E 0...800 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple T - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple T 0...400 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple N - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple N 0...1300 °C
Temperature Drift +/- 0.01 %FS/°C
Repeat accuracy +/-0.5 %FS
Non-linearity +/- 0.2 %FS
Cross talk <= 1 LSB
[Us] rated supply voltage 24 V DC
Supply voltage limits 20.4…28.8 V
Type of cable Twisted shielded pairs cable <98.4 ft (30 m) input
Current consumption 30 mA 24 V DC via external supply
45 mA 5 V DC via bus connector
40 mA 5 V DC via bus connector
Local signalling 1 LED (green) for PWR
Electrical connection 10 x 1.5 mm² removable screw terminal block pitch 3.81 mm for inputs and supply
10 x 1.5 mm² removable screw terminal block pitch 3.81 mm for inputs
Insulation Between input and supply 1500 V AC
Between input and internal logic 500 V AC
Marking CE
Surge withstand 1 kV power supply common mode IEC 61000-4-5
0.5 kV power supply differential mode IEC 61000-4-5
1 kV input common mode IEC 61000-4-5
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Height 3.5 in (90 mm)
Depth 2.8 in (70 mm)
Width 0.9 in (23.6 mm)
Product Weight 0.24 lb(US) (0.11 kg)
TM3TI8TG Schneider Electric
Schneider TM3TI8TG Schneider Electric
Sale price 3 319 kr
Only 7 units left

This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262. The analogue input module provides 8 inputs with 16bit and 15bit + sign resolution. It is an input module with a rated supply voltage of 24V DC and a current consumption of 30mA at 24V DC via external supply, 45mA/40mA at 5V DC via bus connector. This product is capable of controlling variable speed drives or any device equipped with a current or voltage input. There is an insulation between input and supply at 1500V AC, input and internal logic at 500V AC. It is furnished with removable spring terminal for electrical connection with pitch 3.81mm adjustment for inputs and supply. It is an IP20 rated product. Its dimensions are 23.6mm (Width) x 70mm (Depth) x 90mm (Height). It weighs 0.1kg. This product is certified by CE. It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards. This module is compatible with Modicon M241, Modicon M251 and Modicon M221 logic controller. It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount. Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism. A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers. Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.

Main

Characteristic Value(s)
Range of Product Modicon TM3
Product or Component Type Analog input module
Range Compatibility Modicon M221
Modicon M241
Modicon M251
Modicon M262
Analogue input number 8
Analogue input type thermocouple - 200...1000 °C thermocouple J
thermocouple - 200...1300 °C thermocouple K
thermocouple 0...1760 °C thermocouple R
thermocouple 0...1760 °C thermocouple S
thermocouple 0...1820 °C thermocouple B
thermocouple - 200...400 °C thermocouple T
thermocouple - 200...1300 °C thermocouple N
thermocouple - 200...800 °C thermocouple E
NTC 10k thermistor -90...150 °C
PTC thermistor 100...10000 Ohm

Complementary

Characteristic Value(s)
Analogue input resolution 16 bits
15 bits + sign
Input impedance >= 1 MOhm thermocouple
>= 1 MOhm temperature probe
>= 1 MOhm thermistor
LSB value 0.1 °C thermocouple
0.1 °C NTC
1 Ohm PTC/NTC
Conversion time 100 ms + 100 ms per channel + 1 controller cycle time
Sampling duration 100 ms
Absolute accuracy error +/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple C 0...2315 °C
+/- 6 °C at 77 °F (25 °C) for thermocouple R, S 0...200 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple R, S 200...1760 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple B 300...1820 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple K - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple K 0...1300 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple J - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple J 0...1000 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple E - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple E 0...800 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple T - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple T 0...400 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple N - 200...0 °C
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple N 0...1300 °C
Temperature Drift +/- 0.01 %FS/°C
Repeat accuracy +/-0.5 %FS
Non-linearity +/- 0.2 %FS
Cross talk <= 1 LSB
[Us] rated supply voltage 24 V DC
Supply voltage limits 20.4…28.8 V
Type of cable Twisted shielded pairs cable <98.4 ft (30 m) input
Current consumption 30 mA 24 V DC via external supply
45 mA 5 V DC via bus connector
40 mA 5 V DC via bus connector
Local signalling 1 LED (green) for PWR
Electrical connection 10 x 1.5 mm² removable screw terminal block pitch 3.81 mm for inputs and supply
10 x 1.5 mm² removable screw terminal block pitch 3.81 mm for inputs
Insulation Between input and supply 1500 V AC
Between input and internal logic 500 V AC
Marking CE
Surge withstand 1 kV power supply common mode IEC 61000-4-5
0.5 kV power supply differential mode IEC 61000-4-5
1 kV input common mode IEC 61000-4-5
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Height 3.5 in (90 mm)
Depth 2.8 in (70 mm)
Width 0.9 in (23.6 mm)
Product Weight 0.2 lb(US) (0.1 kg)
TM3TM3 Schneider Electric
Schneider TM3TM3 Schneider Electric
Sale price 1 860 kr
In stock, 37 units

Input/output analog module, Modicon TM3, 2 or temperature inputs, 1 output (screw) 24 VDC

TM3TM3G Schneider Electric
Schneider TM3TM3G Schneider Electric
Sale price 4 136 kr
Only 8 units left

This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262. The analogue I/O module provides 2 inputs, 1 output with 16bit, 15bit + sign input resolution. It is an I/O module with a rated supply voltage of 24V DC, a current consumption of 60mA, 55mA at 5V DC via bus connector, 55mA, 80mA at 24V DC via external supply. This product is capable of controlling variable speed drives or any device equipped with a current or voltage input. There is an insulation between input and supply at 1500V AC, input and internal logic at 500V AC, output and supply at 1500V AC and output and internal logic at 500V AC. It is furnished with removable spring terminal for electrical connection with 5.08mm pitch adjustment for inputs, outputs and supply. It is an IP20 rated product. Its dimensions are 23.6mm (Width) x 70mm (Depth) x 90mm (Height). It weighs 0.1kg. This product is certified by CE. It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards. This module is compatible with Modicon M241, Modicon M251 and Modicon M221 logic controller. It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount. Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism. A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers. Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.

Main

Characteristic Value(s)
Range of Product Modicon TM3
Product or Component Type Input/output analog module
Range Compatibility Modicon M221
Modicon M241
Modicon M251
Modicon M262
Analogue input number 2
Analogue input type current 4...20 mA
current 0...20 mA
voltage 0...10 V
voltage - 10...10 V
thermocouple - 200...1000 °C thermocouple J
thermocouple - 200...1300 °C thermocouple K
thermocouple 0...1760 °C thermocouple R
thermocouple 0...1760 °C thermocouple S
thermocouple 0...1820 °C thermocouple B
thermocouple - 200...400 °C thermocouple T
thermocouple - 200...1300 °C thermocouple N
thermocouple - 200...800 °C thermocouple E
thermocouple 0...2315 °C thermocouple C
Ni 100/Ni 1000 temperature probe - 60...180 °C
Pt 100 temperature probe - 200...850 °C
Pt 1000 temperature probe - 200...600 °C
Analogue output number 1
Analogue output type Current 4...20 mA
Current 0...20 mA
Voltage 0...10 V
Voltage - 10...10 V

Complementary

Characteristic Value(s)
Analogue input resolution 16 bits
15 bits + sign
Permissible continuous overload 13 V voltage
40 mA current
Input impedance <= 50 Ohm current
>= 1 MOhm voltage
>= 1 MOhm thermocouple
>= 1 MOhm temperature probe
Analogue output resolution 12 bits
LSB value 0.15 mV 0...10 V voltage
0.30 mV - 10...10 V voltage
0.30 µA 0...20 mA current
0.244 µA 4...20 mA current
0.1 °C temperature probe
0.1 °C thermocouple
2.44 mV 0...10 V voltage
4.88 mV - 10...10 V voltage
4.88 µA 0...20 mA current
3.91 µA 4...20 mA current
Load type Resistive
Load impedance ohmic 1 kOhm voltage
300 Ohm current
Stabilisation time 1 ms
Conversion time 100 ms + 100 ms per channel + 1 controller cycle time thermocouple
100 ms + 100 ms per channel + 1 controller cycle time temperature probe
10 ms + 10 ms per channel + 1 controller cycle time voltage/current
Sampling duration 10 ms voltage/current
100 ms voltage/current
100 ms thermocouple
100 ms temperature probe
Absolute accuracy error +/- 6 °C at 77 °F (25 °C) for thermocouple R, S 0...200 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple K - 200...0 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple J - 200...0 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple E - 200...0 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple T - 200...0 °C
+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple N - 200...0 °C
+/- 0.1 % of full scale at 77 °F (25 °C) for analogue input voltage/current
+/- 0.1 % of full scale at 77 °F (25 °C) for thermocouple C 0...2315 °C
+/- 0.1 % of full scale at 77 °F (25 °C) for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe
+/- 0.1 % of full scale at 77 °F (25 °C) for thermocouple R, S 200...1760 °C
+/- 0.1 % of full scale at 77 °F (25 °C) for thermocouple B 300...1820 °C
+/- 0.1 % of full scale at 77 °F (25 °C) for thermocouple K 0...1300 °C
+/- 0.1 % of full scale at 77 °F (25 °C) for thermocouple J 0...1000 °C
+/- 0.1 % of full scale at 77 °F (25 °C) for thermocouple E 0...800 °C
+/- 0.1 % of full scale at 77 °F (25 °C) for thermocouple T 0...400 °C
+/- 0.1 % of full scale at 77 °F (25 °C) for thermocouple N 0...1300 °C
+/- 0.1 % of full scale at 77 °F (25 °C) for analogue output voltage/current
Temperature Drift +/- 0.006 %FS/°C
Repeat accuracy +/-0.5 %FS input
+/- 0.4 %FS output
Non-linearity +/- 0.01 %FS analog output
+/- 0.1 %FS analog input
Output ripple 20 mV
Cross talk <= 1 LSB
[Us] rated supply voltage 24 V DC
Supply voltage limits 20.4…28.8 V
Type of cable Twisted shielded pairs cable <98.4 ft (30 m) input/output
Current consumption 55 mA 24 V DC via external supply no load
55 mA 5 V DC via bus connector no load
60 mA 5 V DC via bus connector full load
80 mA 24 V DC via external supply full load
Local signalling 1 LED (green) for PWR
Electrical connection 11 x 2.5 mm² removable spring terminal block pitch 5.08 mm for inputs, outputs and supply
Insulation Between input and supply 1500 V AC
Between input and internal logic 500 V AC
Between output and supply 1500 V AC
Between output and internal logic 500 V AC
Marking CE
Surge withstand 1 kV power supply common mode IEC 61000-4-5
0.5 kV power supply differential mode IEC 61000-4-5
1 kV I/O common mode IEC 61000-4-5
0.5 kV I/O differential mode IEC 61000-4-5
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Height 3.5 in (90 mm)
Depth 2.8 in (70 mm)
Width 0.9 in (23.6 mm)
Product Weight 0.2 lb(US) (0.1 kg)
TM3XFHSC202 Schneider Electric
Schneider TM3XFHSC202 Schneider Electric
Sale price 7 699 kr
In stock, 20 units

Main

Characteristic Value(s)
Range of Product Modicon TM3
Product or Component Type Module hight speed counting
Range Compatibility Modicon M262
[Us] rated supply voltage 24 V DC external supply - 15...20 %)
Number of input channels 10
Number of output channels 8
Discrete I/O number 18

Complementary

Characteristic Value(s)
Current consumption 100 mA 5 V DC
50 mA 24 V DC
Counting frequency 200 kHz
Discrete input voltage 24 V DC
Electrical circuit type Standard input
Latch input
Discrete input logic Sink or source
Output voltage 24 V DC transistor output
Output voltage limits 30 V DC
Discrete output current 300 mA fast output Q0...Q7)
Discrete output logic Source
Output protection type Against overload and short-circuits
Reset Automatic reset
Local signalling 1 LED I/O
1 LED RUN
1 LED ERR
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Services HSC simple One shot/Modulo
HSC main single phase One shot/Modulo/Event counting
HSC main dual phase Modulo/Free-large
Period meter Edge to Edge, Edge to Opposite
Counting mode 2 main expert function (main counting function, frequency meter, period meter)
Max 8 simple counting function
Event management 8 maximum per PLC <= 100 µs
Thresholds < 10 µs
Height 3.5 in (90 mm)
Depth 3.3 in (85 mm)
Width 1.5 in (39 mm)
Product Weight 5.3 oz (150 g)
TM3XFHSC202G Schneider Electric
Schneider TM3XFHSC202G Schneider Electric
Sale price 13 767 kr
Only 3 units left

Main

Characteristic Value(s)
Range of Product Modicon TM3
Product or Component Type Module hight speed counting
Range Compatibility Modicon M262
[Us] rated supply voltage 24 V DC external supply - 15...20 %)
Number of input channels 10
Number of output channels 8
Discrete I/O number 18

Complementary

Characteristic Value(s)
Current consumption 100 mA 5 V DC
50 mA 24 V DC
Counting frequency 200 kHz
Discrete input voltage 24 V DC
Electrical circuit type Standard input
Latch input
Discrete input logic Sink or source
Output voltage 24 V DC transistor output
Output voltage limits 30 V DC
Discrete output current 300 mA fast output Q0...Q7)
Discrete output logic Source
Output protection type Against overload and short-circuits
Reset Automatic reset
Local signalling 1 LED I/O
1 LED RUN
1 LED ERR
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Services HSC simple One shot/Modulo
HSC main single phase One shot/Modulo/Event counting
HSC main dual phase Modulo/Free-large
Period meter Edge to Edge, Edge to Opposite
Counting mode 2 main expert function (main counting function, frequency meter, period meter)
Max 8 simple counting function
Event management 8 maximum per PLC <= 100 µs
Thresholds < 10 µs
Height 3.5 in (90 mm)
Depth 3.3 in (85 mm)
Width 1.5 in (39 mm)
Product Weight 5.3 oz (150 g)
TM3XHSC202 Schneider Electric
Schneider TM3XHSC202 Schneider Electric
Sale price 6 350 kr
Only 1 unit left

Main

Characteristic Value(s)
Range of Product Modicon TM3
Product or Component Type Module hight speed counting
Range Compatibility Modicon M262
[Us] rated supply voltage 24 V DC external supply - 15...20 %)
Number of input channels 10
Number of output channels 8
Discrete I/O number 18

Complementary

Characteristic Value(s)
Current consumption 100 mA 5 V DC
50 mA 24 V DC
Counting frequency 200 kHz
Discrete input voltage 24 V DC
Electrical circuit type Standard input
Latch input
Discrete input logic Sink or source
Output voltage 24 V DC transistor output
Output voltage limits 30 V DC
Discrete output current 300 mA fast output Q0...Q7)
Discrete output logic Source
Output protection type Against overload and short-circuits
Reset Automatic reset
Local signalling 1 LED I/O
1 LED RUN
1 LED ERR
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Services HSC simple One shot/Modulo
HSC main single phase One shot/Modulo/Event counting
HSC main dual phase Modulo/Free-large
Period meter Edge to Edge, Edge to Opposite
Counting mode 2 main expert function (main counting function, frequency meter, period meter)
Max 8 simple counting function
Event management No event
Thresholds < 10 µs
Height 3.5 in (90 mm)
Depth 3.3 in (85 mm)
Width 1.5 in (39 mm)
Product Weight 5.3 oz (150 g)
TM3XHSC202G Schneider Electric
Schneider TM3XHSC202G Schneider Electric
Sale price 6 044 kr
Only 7 units left

Main

Characteristic Value(s)
Range of Product Modicon TM3
Product or Component Type Module hight speed counting
Range Compatibility Modicon M262
[Us] rated supply voltage 24 V DC external supply - 15...20 %)
Number of input channels 10
Number of output channels 8
Discrete I/O number 18

Complementary

Characteristic Value(s)
Current consumption 100 mA 5 V DC
50 mA 24 V DC
Counting frequency 200 kHz
Discrete input voltage 24 V DC
Electrical circuit type Standard input
Latch input
Discrete input logic Sink or source
Output voltage 24 V DC transistor output
Output voltage limits 30 V DC
Discrete output current 300 mA fast output Q0...Q7)
Discrete output logic Source
Output protection type Against overload and short-circuits
Reset Automatic reset
Local signalling 1 LED I/O
1 LED RUN
1 LED ERR
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Services HSC simple One shot/Modulo
HSC main single phase One shot/Modulo/Event counting
HSC main dual phase Modulo/Free-large
Period meter Edge to Edge, Edge to Opposite
Counting mode 2 main expert function (main counting function, frequency meter, period meter)
Max 8 simple counting function
Event management No event
Thresholds < 10 µs
Height 3.5 in (90 mm)
Depth 3.3 in (85 mm)
Width 1.5 in (39 mm)
Product Weight 5.3 oz (150 g)
TM3XREC1 Schneider
Schneider TM3XREC1 Schneider
Sale price 1 523 kr
In stock, 38 units

This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262. The remote receiver module is physically connected by a bus expansion cable, provides 7 I/O channels. It is remote receiver module with a rated supply voltage of 24V DC, a current consumption of 40mA at 24V DC via bus connector and a maximum power dissipation of 1W. The cable distance between devices is 0.5mm to 5mm extension cable with 2 RJ45 conductor between receiver and transmitter. It is furnished with RJ45 connector for connecting the bus transmitter, removable screw terminal block, 3 terminals for electrical connection. It is an IP20 rated product. Its dimensions are 23.65mm (Width) x 73.3mm (Depth) x 90mm (Height). It weighs 0.075kg. This product is certified by CE, Merchant Navy, GOST, CSA HazLoc, C-Tick. It meets Class I Division 2 Groups A/B/C/D CSA C22.2 No 213, Class I Division 2 Groups A/B/C UL 1604, CSA C22.2 No 142, IEC 61131-2 and UL 508 standards. This module is compatible with Modicon M262, Modicon M241, Modicon M251 and Modicon M221 logic controller. It supports top hat type TH35-15 rail conforming to IEC 60715, top hat type TH35-7.5 rail conforming to IEC 60715, plate or panel with fixing kit mount. Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism. A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers. Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.

Main

Characteristic Value(s)
Range of Product Modicon TM3
Product or Component Type Remote receiver module
Range Compatibility Modicon M221
Modicon M251
Modicon M241
Modicon M262
[Us] rated supply voltage 24 V DC external supply - 15...20 %)

Complementary

Characteristic Value(s)
Maximum Number of I/O Expansion Module 7
Power supply output current 560 mA 5 V expansion bus
560 mA 24 V expansion bus
Current consumption 40 mA 24 V DC via bus connector
Maximum power dissipation in W 1 W
Cable distance between devices 0.02…0.2 in (0.5…5 mm) extension cable 2 RJ45 between receiver and transmitter
Local signalling 1 LED (green) for power supply
1 LED (green) for link status
Electrical connection RJ45 connector for connecting the bus transmitter
removable screw terminal block, 3 for connecting the 24 V DC power supply
Marking CE
Resistance to electrostatic discharge 8 kV in air IEC 61000-4-2
6 kV on contact IEC 61000-4-2
Resistance to electromagnetic fields 9.1 V/m (10 V/m) 80 MHz...1 GHz IEC 61000-4-3
2.7 V/m (3 V/m) 1.4 GHz...2 GHz IEC 61000-4-3
0.9 V/m (1 V/m) 2...2.7 GHz IEC 61000-4-3
Resistance to conducted disturbances 10 V 0.15...80 MHz IEC 61000-4-6
3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
Electromagnetic emission Radiated emissions 40 dBμV/m QP class A 10 m)30…230 MHz IEC 55011
Radiated emissions 47 dBμV/m QP class A 10 m)230…1000 MHz IEC 55011
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Height 3.5 in (90 mm)
Depth 2.9 in (73.3 mm)
Width 0.93 in (23.65 mm)
Product Weight 0.165 lb(US) (0.075 kg)
TM3XTRA1 Schneider
Schneider TM3XTRA1 Schneider
Sale price 1 323 kr
Only 5 units left

remote transmitter module TM3 - bus