CAN bus connection Integrated terminating resistor The interface module can be used to expand the X20 CPU for specific applications. It is equipped with a CAN bus interface.
Hub expansion module 2x hub 100 BASE-TX The POWERLINK bus controller X20BC8083 and the stand-alone hubs X20HB8880 and X20HB8815 are equipped with a modular hub expansion. An additional 1 or 2 slots are available, depending on the bus base used. The X20HB2880 hub expansion module can be operated in these slots. The status of the module and network are indicated by LEDs
16 digital outputs Source connection 1-wire connections Integrated output protection The module is equipped with 16 outputs for 1-wire connections. The module is designed for source output wiring.
8 digital outputs Source connection 1-wire connections Integrated output protection The module is equipped with 8 outputs for 1-wire connections and designed for source output wiring.
6 digital outputs Relay module for 115 VAC 6 normally open contacts Single-channel isolated outputs The module is equipped with 6 relay outputs with normally open contacts for 115 VAC. The outputs are single-channel isolated.
6 digital outputs Source connection 2-wire connections GND for signal supply Integrated output protection 1-wire connection type with 6-pin terminal block OSP mode The module is equipped with 6 outputs for 1 or 2-wire connections. The X20 6-pin terminal block can be used for universal 1-line wiring. 2-line wiring can be implemented using the 12-pin terminal block. The module is designed for source output wiring.
12 digital inputs Sink connection 1-wire connections Software input filter can be configured for entire module The module is equipped with 12 inputs for 1-wire connections. The module is designed for sink input wiring.
RS485/RS422 interface for serial, remote connection of complex devices to the X20 system Integrated terminating resistor In addition to the standard I/O, complex devices often need to be connected. The X20CS communication modules are intended precisely for cases like this. As normal X20 electronics modules, they can be placed anywhere on the remote backplane.
Intel Atom 1.0 GHz processor with an additional I/O processor Onboard Ethernet, POWERLINK with poll response chaining and USB 3 slots for modular interface expansion CompactFlash as removable application memory 256 MB DDR2-SDRAM Controller redundancy possible Fanless The X20CP3585 controller is based on an Atom processor clocked at 1 GHz and equipped with 256 MB DDR2 SDRAM. USB, Ethernet, POWERLINK and removable CompactFlash are all included as standard features. A Gigabit Ethernet interface is a standard feature. For even more real-time network performance, the onboard POWERLINK interface supports poll response chaining mode (PRC). The controller is equipped with 3 slots available for X20 communication modules. Various bus and network systems can easily be integrated into the X20 system through the use of communication modules.
Intel Celeron 650 Performance with additional I/O processor Ethernet, POWERLINK and USB onboard 1 slot for modular interface expansion CompactFlash as removable application memory Fan can be exchanged from the outside, tool-free Extremely compact The X20CP1486 is a high-performance CPU for the X20 System. This CPU can be used anywhere from high-end applications in machine manufacturing to demanding tasks in process control. Ethernet and USB are onboard. In addition, the CPU has a POWERLINK connection for real-time communication. The only differences from the X20CP3486 are that the X20CP1486 only has one slot for interface modules and a smaller width.
Intel x86-based, 100 MHz-compatible CPU with integrated I/O processor Onboard Ethernet, POWERLINK and USB 1 slot for modular interface expansion CompactFlash as removable application memory Fanless The Intel x86-based, 100 MHz-compatible X20CP1483 represents the entry-level X20 controllers. With an optimum price/performance ratio, it has the same basic features as all of the larger controllers. Onboard Ethernet and USB are standard. In addition, the controller has a POWERLINK connection for hard real-time communication. Another slot is available for an additional interface module to increase flexibility. The only difference between the two variants X20CP1483 and X20CP1483-1 is the size of the SDRAM.
Intel x86 400 MHz compatible with integrated I/O processor Ethernet, POWERLINK with poll-response chaining and onboard USB 1 slot for modular interface expansion 30 digital inputs/outputs and 2 analog inputs integrated in the device 2 GB onboard flash drive 256 MB DDR3 SDRAM Fanless No battery Backed-up real-time clock The X20 Compact controller series is characterized by 3 integrated I/O modules. The device is equipped with 30 different digital inputs/outputs and 2 analog inputs. 1 analog input can be used for Pt1000 resistance temperature measurement. The X20CP1382 is equipped with an Intel x86 400 MHz compatible processor, 256 MB RAM and 2 GB built-in flash drive. The FRAM for storing remanent variables has 32 kB available. A fanless and battery-free design ensures maintenance-free operation. The controller is equipped with Ethernet, 2x USB and an RS232 interface. In addition, POWERLINK and CAN bus are available as integrated interfaces. For additional fieldbus connections, each controller can be expanded with an interface module from the X20 standard portfolio.
Basis for all power supply modules For creating potential groups The internal I/O power supply is interrupted to the left. The bus module is the base for all power supply modules.
POWERLINK I/O configuration and firmware update via the fieldbus Integrated hub for economical wiring The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.
6 inputs for thermocouples For sensor types J, K, N, S, B, R Additional direct raw value measurement Integrated terminal temperature compensation Configurable filter time The module is equipped with 6 inputs for J, K, N, S, B and R thermocouple sensors. The module has an integrated terminal temperature compensation.
4 inputs for resistance temperature measurement For PT100 and PT1000 Configurable sensor type per channel Direct resistance measurement Configurable 2- or 3- wire connections per module Configurable filter time The module is equipped with 4 inputs for PT100/PT1000 resistance temperature measurement.
2 analog outputs Either current or voltage signal possible 13-bit digital converter resolution The module is equipped with 2 outputs with 13-bit (including sign) digital converter resolution. It is possible to select between the current and voltage signal using different terminals. This module is designed for X20 6-pin terminal blocks. If needed (e.g. for logistical reasons), the 12-pin terminal block can also be used.
4 analog inputs Either current or voltage signal possible 16-bit digital converter resolution Simultaneous input conversion Very fast conversion time The module is equipped with 4 inputs with 16-bit digital converter resolution. It is possible to select between the current and voltage signal using different terminals.
X20 analog input module, 4 inputs, ±10 V or 0 to 20 mA / 4 to 20 mA, 13-bit converter resolution, configurable input filte
Tool-free wiring with push-in technology Simple wire release using a screwdriver Ability to label each terminal Plain text labeling also possible Test access for standard probes Can be customer-coded X20 24 VDC modules with 16 connections are wired using the X20TB1F terminal block.
Tool-free wiring with push-in technology Simple wire release using lever Ability to label each terminal Plain text labeling also possible Test access for standard probes Can be customer-coded The X20 24 VDC modules are wired using the X20TB06 and X20TB12 terminal blocks.
Description: DC551-CS31:S500,Bus Module 8DI/16DC DI:24VDC,DC:24VDC/0.5A,1-wire CS31