Ordering
1 piece
85371091
Popular Downloads
Dimensions
435 mm
493 mm
369 mm
46.5 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 250 kW
(400 V) 450 kW
(500 V) 600 kW
(690 V) 800 kW
(230 V) 250 kW
(400 V) 450 kW
(500 V) 600 kW
(690 V) 800 kW
840 A
at 230 V 450 kW
at 400 V 800 kW
at 500 V 1000 kW
at 690 V 1400 kW
at 230 V 450 kW
at 400 V 800 kW
at 500 V 1000 kW
at 690 V 1400 kW
1455 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 45 N·m
PSTX840
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 300 Hp
(220 ... 240 V AC) Three Phase 350 Hp
(440 ... 480 V AC) Three Phase 700 Hp
(550 ... 600 V AC) Three Phase 800 Hp
(200 ... 208 V AC) Three Phase 300 Hp
(220 ... 240 V AC) Three Phase 350 Hp
(440 ... 480 V AC) Three Phase 700 Hp
(550 ... 600 V AC) Three Phase 800 Hp
Main Circuit 690 V
Main Circuit 398.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
600 mm
616 mm
800 mm
58.5 kg
7320500510414
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
435 mm
515 mm
367 mm
62.3 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 315 kW
(400 V) 560 kW
(500 V) 730 kW
(690 V) 1000 kW
(230 V) 315 kW
(400 V) 560 kW
(500 V) 730 kW
(690 V) 1000 kW
1050 A
at 230 V 500 kW
at 400 V 1000 kW
at 500 V 1250 kW
at 690 V 1700 kW
at 230 V 500 kW
at 400 V 1000 kW
at 500 V 1250 kW
at 690 V 1700 kW
1810 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 45 N·m
PSTX1050
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 450 Hp
(440 ... 480 V AC) Three Phase 900 Hp
(550 ... 600 V AC) Three Phase 1000 Hp
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 450 Hp
(440 ... 480 V AC) Three Phase 900 Hp
(550 ... 600 V AC) Three Phase 1000 Hp
Main Circuit 690 V
Main Circuit 398.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
4. Large Equipment (Any External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
600 mm
616 mm
800 mm
74.3 kg
7320500510452
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
435 mm
565 mm
367 mm
63.3 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 400 kW
(400 V) 710 kW
(500 V) 880 kW
(690 V) 1200 kW
(230 V) 400 kW
(400 V) 710 kW
(500 V) 880 kW
(690 V) 1200 kW
1250 A
at 230 V 670 kW
at 400 V 1200 kW
at 500 V 1500 kW
at 690 V 2000 kW
at 230 V 670 kW
at 400 V 1200 kW
at 500 V 1500 kW
at 690 V 2000 kW
2160 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 A
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 45 N·m
PSTX1250
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 500 Hp
(440 ... 480 V AC) Three Phase 1000 Hp
(550 ... 600 V AC) Three Phase 1200 Hp
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 500 Hp
(440 ... 480 V AC) Three Phase 1000 Hp
(550 ... 600 V AC) Three Phase 1200 Hp
Main Circuit 690 V
Main Circuit 398.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
4. Large Equipment (Any External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
600 mm
616 mm
800 mm
75.3 kg
7320500510483
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
114 mm
140 mm
45 mm
0.4 kg
Technical
208 ... 600 V AC
100 ... 240 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 0.75 kW
(400 V) 1.5 kW
(500 V) 2.2 kW
(230 V) 0.75 kW
(400 V) 1.5 kW
(500 V) 2.2 kW
3.9 A
100 %
Recommended MS116 0.63 ... 4.00
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
No
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Screw Terminals
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
PSR3
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 0.5 Hp
(220 ... 240 V AC) Three Phase 0.75 Hp
(440 ... 480 V AC) Three Phase 2 Hp
(550 ... 600 V AC) Three Phase 2 Hp
(200 ... 208 V AC) Three Phase 0.5 Hp
(220 ... 240 V AC) Three Phase 0.75 Hp
(440 ... 480 V AC) Three Phase 2 Hp
(550 ... 600 V AC) Three Phase 2 Hp
Main Circuit 600 V
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
121 mm
50 mm
156 mm
0.5 kg
7320500338186
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
114 mm
140 mm
45 mm
0.4 kg
Technical
208 ... 600 V AC
100 ... 240 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 1.5 kW
(400 V) 3 kW
(500 V) 4 kW
(230 V) 1.5 kW
(400 V) 3 kW
(500 V) 4 kW
6.8 A
100 %
Recommended MS116 4.00 ... 10.00
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
No
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Screw Terminals
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
PSR6
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 1 Hp
(220 ... 240 V AC) Three Phase 1.5 Hp
(440 ... 480 V AC) Three Phase 3 Hp
(550 ... 600 V AC) Three Phase 5 Hp
(200 ... 208 V AC) Three Phase 1 Hp
(220 ... 240 V AC) Three Phase 1.5 Hp
(440 ... 480 V AC) Three Phase 3 Hp
(550 ... 600 V AC) Three Phase 5 Hp
Main Circuit 600 V
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
121 mm
50 mm
156 mm
0.5 kg
7320500338209
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
114 mm
140 mm
45 mm
0.4 kg
Technical
208 ... 600 V AC
100 ... 240 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 2.2 kW
(400 V) 4 kW
(500 V) 4 kW
(230 V) 2.2 kW
(400 V) 4 kW
(500 V) 4 kW
9 A
100 %
Recommended MS116 6.30 ... 10.00
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
No
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Screw Terminals
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
PSR9
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 2 Hp
(220 ... 240 V AC) Three Phase 2 Hp
(440 ... 480 V AC) Three Phase 5 Hp
(550 ... 600 V AC) Three Phase 7.5 Hp
(200 ... 208 V AC) Three Phase 2 Hp
(220 ... 240 V AC) Three Phase 2 Hp
(440 ... 480 V AC) Three Phase 5 Hp
(550 ... 600 V AC) Three Phase 7.5 Hp
Main Circuit 600 V
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
121 mm
50 mm
156 mm
0.5 kg
7320500338223
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
114 mm
140 mm
45 mm
0.4 kg
Technical
208 ... 600 V AC
100 ... 240 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 3 kW
(400 V) 5.5 kW
(500 V) 5.5 kW
(230 V) 3 kW
(400 V) 5.5 kW
(500 V) 5.5 kW
12 A
100 %
Recommended MS132 10.00 ... 16.00
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
No
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Screw Terminals
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
PSR12
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 3 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 7.5 Hp
(550 ... 600 V AC) Three Phase 10 Hp
(200 ... 208 V AC) Three Phase 3 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 7.5 Hp
(550 ... 600 V AC) Three Phase 10 Hp
Main Circuit 600 V
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
121 mm
50 mm
156 mm
0.5 kg
7320500338247
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
114 mm
140 mm
45 mm
0.4 kg
Technical
208 ... 600 V AC
100 ... 240 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 4 kW
(400 V) 7.5 kW
(500 V) 7.5 kW
(230 V) 4 kW
(400 V) 7.5 kW
(500 V) 7.5 kW
16 A
100 %
Recommended MS132 10.00 ... 16.00
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
No
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Screw Terminals
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
PSR16
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 3 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
(200 ... 208 V AC) Three Phase 3 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
Main Circuit 600 V
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
121 mm
50 mm
156 mm
0.5 kg
7320500338261
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
128 mm
160 mm
45 mm
0.6 kg
Technical
208 ... 600 V AC
100 ... 240 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 5.5 kW
(400 V) 11 kW
(500 V) 15 kW
(230 V) 5.5 kW
(400 V) 11 kW
(500 V) 15 kW
25 A
100 %
Recommended MS132 20 ... 25
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
Yes
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Screw Terminals
Rigid 1/2 x 2.5 ... 10 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
Rigid 1 x 0.75 ... 2.5
Control Circuit 0.6 N·m
Main Circuit 2.3 N·m
Supply Circuit 0.6 N·m
Control Circuit 0.6 N·m
Main Circuit 2.3 N·m
Supply Circuit 0.6 N·m
PSR25
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 7.5 Hp
(440 ... 480 V AC) Three Phase 15 Hp
(550 ... 600 V AC) Three Phase 20 Hp
(200 ... 208 V AC) Three Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 7.5 Hp
(440 ... 480 V AC) Three Phase 15 Hp
(550 ... 600 V AC) Three Phase 20 Hp
Main Circuit 600 V
Control Circuit 5.3 in·lb
Main Circuit 20.4
Supply Circuit 5.3 in·lb
Control Circuit 5.3 in·lb
Main Circuit 20.4
Supply Circuit 5.3 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
137 mm
50 mm
176 mm
0.7 kg
7320500338285
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
128 mm
160 mm
45 mm
0.6 kg
Technical
208 ... 600 V AC
100 ... 240 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 7.5 kW
(400 V) 15 kW
(500 V) 18.5 kW
(230 V) 7.5 kW
(400 V) 15 kW
(500 V) 18.5 kW
30 A
100 %
Recommended MS132 25 ... 32
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
Yes
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Screw Terminals
Rigid 1/2 x 2.5 ... 10 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
Rigid 1 x 0.75 ... 2.5
Control Circuit 0.6 N·m
Main Circuit 2.3 N·m
Supply Circuit 0.6 N·m
Control Circuit 0.6 N·m
Main Circuit 2.3 N·m
Supply Circuit 0.6 N·m
PSR30
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 25 Hp
(200 ... 208 V AC) Three Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 25 Hp
Main Circuit 600 V
Control Circuit 5.3 in·lb
Main Circuit 20.4
Supply Circuit 5.3 in·lb
Control Circuit 5.3 in·lb
Main Circuit 20.4
Supply Circuit 5.3 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
137 mm
50 mm
176 mm
0.7 kg
7320500338308
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
153 mm
187 mm
54 mm
1 kg
Technical
208 ... 600 V AC
100 ... 240 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 7.5 kW
(400 V) 18.5 kW
(500 V) 22 kW
(230 V) 7.5 kW
(400 V) 18.5 kW
(500 V) 22 kW
37 A
100 %
Recommended MS450 28 ... 40
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
Yes
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Screw Terminals
Rigid 1x 6 ... 35 mm²
Rigid 2 x 6 ... 16 mm²
Rigid 1x 6 ... 35 mm²
Rigid 2 x 6 ... 16 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
Rigid 1 x 0.75 ... 2.5
Control Circuit 0.6 N·m
Main Circuit 4 N·m
Supply Circuit 0.6 N·m
Control Circuit 0.6 N·m
Main Circuit 4 N·m
Supply Circuit 0.6 N·m
PSR37
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 25 Hp
(550 ... 600 V AC) Three Phase 30 Hp
(200 ... 208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 25 Hp
(550 ... 600 V AC) Three Phase 30 Hp
Main Circuit 600 V
Control Circuit 5.3 in·lb
Main Circuit 35.4
Supply Circuit 5.3 in·lb
Control Circuit 5.3 in·lb
Main Circuit 35.4
Supply Circuit 5.3 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
163 mm
56 mm
217 mm
1.1 kg
7320500338322
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
153 mm
187 mm
54 mm
1 kg
Technical
208 ... 600 V AC
100 ... 240 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 11 kW
(400 V) 22 kW
(500 V) 30 kW
(230 V) 11 kW
(400 V) 22 kW
(500 V) 30 kW
45 A
100 %
Recommended MS450 36 ... 45
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
Yes
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Screw Terminals
Rigid 1x 6 ... 35 mm²
Rigid 2 x 6 ... 16 mm²
Rigid 1x 6 ... 35 mm²
Rigid 2 x 6 ... 16 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
Rigid 1 x 0.75 ... 2.5
Control Circuit 0.6 N·m
Main Circuit 4 N·m
Supply Circuit 0.6 N·m
Control Circuit 0.6 N·m
Main Circuit 4 N·m
Supply Circuit 0.6 N·m
PSR45
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 15 Hp
(220 ... 240 V AC) Three Phase 15 Hp
(440 ... 480 V AC) Three Phase 30 Hp
(550 ... 600 V AC) Three Phase 40 Hp
(200 ... 208 V AC) Three Phase 15 Hp
(220 ... 240 V AC) Three Phase 15 Hp
(440 ... 480 V AC) Three Phase 30 Hp
(550 ... 600 V AC) Three Phase 40 Hp
Main Circuit 600 V
Control Circuit 5.3 in·lb
Main Circuit 35.4
Supply Circuit 5.3 in·lb
Control Circuit 5.3 in·lb
Main Circuit 35.4
Supply Circuit 5.3 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
163 mm
56 mm
217 mm
1.1 kg
7320500338346
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
180 mm
220 mm
70 mm
2.1 kg
Technical
208 ... 600 V AC
100 ... 240 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 15 kW
(400 V) 30 kW
(500 V) 37 kW
(230 V) 15 kW
(400 V) 30 kW
(500 V) 37 kW
60 A
100 %
Recommended MS495 45 ... 63
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
Yes
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Main Circuit: Bars
Rigid 1x 10 ... 95 mm²
Rigid 2 x 6 ... 35 mm²
Rigid 1x 10 ... 95 mm²
Rigid 2 x 6 ... 35 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
Rigid 1 x 0.75 ... 2.5
Control Circuit 0.6 N·m
Main Circuit 8 N·m
Supply Circuit 0.6 N·m
Control Circuit 0.6 N·m
Main Circuit 8 N·m
Supply Circuit 0.6 N·m
PSR60
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp
(200 ... 208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp
Main Circuit 600 V
Control Circuit 5.3 in·lb
Main Circuit 70.8
Supply Circuit 5.3 in·lb
Control Circuit 5.3 in·lb
Main Circuit 70.8
Supply Circuit 5.3 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
195 mm
86 mm
230 mm
2.3 kg
7320500362594
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
180 mm
220 mm
70 mm
2.1 kg
Technical
208 ... 600 V AC
100 ... 240 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 22 kW
(400 V) 37 kW
(500 V) 45 kW
(230 V) 22 kW
(400 V) 37 kW
(500 V) 45 kW
72 A
100 %
Recommended MS495 57 ... 75
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
Yes
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Main Circuit: Bars
Rigid 1x 10 ... 95 mm²
Rigid 2 x 6 ... 35 mm²
Rigid 1x 10 ... 95 mm²
Rigid 2 x 6 ... 35 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
Rigid 1 x 0.75 ... 2.5
Control Circuit 0.6 N·m
Main Circuit 8 N·m
Supply Circuit 0.6 N·m
Control Circuit 0.6 N·m
Main Circuit 8 N·m
Supply Circuit 0.6 N·m
PSR72
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 25 Hp
(440 ... 480 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 60 Hp
(200 ... 208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 25 Hp
(440 ... 480 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 60 Hp
Main Circuit 600 V
Control Circuit 5.3 in·lb
Main Circuit 70.8
Supply Circuit 5.3 in·lb
Control Circuit 5.3 in·lb
Main Circuit 70.8
Supply Circuit 5.3 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
195 mm
86 mm
230 mm
2.3 kg
7320500362617
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
180 mm
220 mm
70 mm
2.1 kg
Technical
208 ... 600 V AC
100 ... 240 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 22 kW
(400 V) 45 kW
(500 V) 55 kW
(230 V) 22 kW
(400 V) 45 kW
(500 V) 55 kW
85 A
100 %
Recommended MS495 70 ... 90
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
Yes
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Main Circuit: Bars
Rigid 1x 10 ... 95 mm²
Rigid 2 x 6 ... 35 mm²
Rigid 1x 10 ... 95 mm²
Rigid 2 x 6 ... 35 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
Rigid 1 x 0.75 ... 2.5
Control Circuit 0.6 N·m
Main Circuit 8 N·m
Supply Circuit 0.6 N·m
Control Circuit 0.6 N·m
Main Circuit 8 N·m
Supply Circuit 0.6 N·m
PSR85
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 25 Hp
(220 ... 240 V AC) Three Phase 30 Hp
(440 ... 480 V AC) Three Phase 60 Hp
(550 ... 600 V AC) Three Phase 75 Hp
(200 ... 208 V AC) Three Phase 25 Hp
(220 ... 240 V AC) Three Phase 30 Hp
(440 ... 480 V AC) Three Phase 60 Hp
(550 ... 600 V AC) Three Phase 75 Hp
Main Circuit 600 V
Control Circuit 5.3 in·lb
Main Circuit 70.8
Supply Circuit 5.3 in·lb
Control Circuit 5.3 in·lb
Main Circuit 70.8
Supply Circuit 5.3 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
195 mm
86 mm
230 mm
2.3 kg
7320500362631
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
180 mm
220 mm
70 mm
2.1 kg
Technical
208 ... 600 V AC
100 ... 240 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 30 kW
(400 V) 55 kW
(500 V) 55 kW
(230 V) 30 kW
(400 V) 55 kW
(500 V) 55 kW
105 A
100 %
Recommended MS495 80 ... 100
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
Yes
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Main Circuit: Bars
Rigid 1x 10 ... 95 mm²
Rigid 2 x 6 ... 35 mm²
Rigid 1x 10 ... 95 mm²
Rigid 2 x 6 ... 35 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5 mm²
Rigid 2 x 0.75 ... 1.5 mm²
Rigid 1 x 0.75 ... 2.5
Control Circuit 0.6 N·m
Main Circuit 8 N·m
Supply Circuit 0.6 N·m
Control Circuit 0.6 N·m
Main Circuit 8 N·m
Supply Circuit 0.6 N·m
PSR105
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 30 Hp
(220 ... 240 V AC) Three Phase 40 Hp
(440 ... 480 V AC) Three Phase 75 Hp
(550 ... 600 V AC) Three Phase 100 Hp
(200 ... 208 V AC) Three Phase 30 Hp
(220 ... 240 V AC) Three Phase 40 Hp
(440 ... 480 V AC) Three Phase 75 Hp
(550 ... 600 V AC) Three Phase 100 Hp
Main Circuit 600 V
Control Circuit 5.3 in·lb
Main Circuit 70.8
Supply Circuit 5.3 in·lb
Control Circuit 5.3 in·lb
Main Circuit 70.8
Supply Circuit 5.3 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
1caf577d-084a-43ed-a6ea-ef420754c09b China
a8f395b5-1127-4638-8024-38a783c152c8 Belgium
7d0a9760-9ea1-42b3-98f7-4e724ef78911 Poland
ed1fc283-6b27-44d8-8725-2b46b433421a Denmark
0bdb76ec-7ca1-4b70-b302-7ce5f5411d23 Portugal
413c893f-1b83-46db-a180-b4c6ddd8ed02 Netherlands
3bd6648c-29e3-41bc-bc3a-93d519ff0fd7 Bulgaria
1bc9c8fd-2c4f-455a-9977-4887c7bdc5e9 Poland
e31abd8d-ff59-41c7-937b-62844b638e0d Germany
5ca5841d-38cb-43f9-95d0-d547b5cc1c12 Germany
c00b7270-a71e-4bd4-bc1e-dd67592b7405 Germany
63b14012-9a30-4e55-b03e-0bedb8a4a173 Germany
d699c2c1-358f-4a8a-81f0-e5b622e834a7 Norway
02646bbe-118b-4dfb-a731-db51161ae5c9 Germany
5c35b4cf-0c63-4b15-a6fb-ab83ad47108a Estonia
395938c2-85aa-422f-b15e-48fb826e6f29 Spain
68262a02-2979-4a6e-ba6f-e25ba3ce04cc Greece
9f2eebb8-e7dc-4bc8-ab03-92e142d9f09e Sweden
d38c2dfb-b3d2-4f38-99f9-f4de1358db63 Czech Republic
2dfb37a8-a9ee-4079-93a7-1f9a4e28beb3 Hungary
1d4c812f-b182-4699-bfd3-7a1f1090f717 Belgium
8aebbb82-2d49-4924-9fc9-cac09a75134d Croatia
530e9cc9-4151-4420-bf5c-123d46350c74 Sweden
3aae3b40-98ac-4f01-9190-644b0b615b15 Hungary
90b967be-3424-47ac-b669-e9ac5daae122 Poland
94dad42b-f290-40eb-93c8-2f48e8aaf1a1 France
a61bf1ca-7d1f-4cca-943f-fa33880a9424 Finland
ea2dd0ce-0a6b-47c6-a85d-244d66f62874 France
a8f395b5-1127-4638-8024-38a783c152c8 Belgium
7d0a9760-9ea1-42b3-98f7-4e724ef78911 Poland
ed1fc283-6b27-44d8-8725-2b46b433421a Denmark
0bdb76ec-7ca1-4b70-b302-7ce5f5411d23 Portugal
413c893f-1b83-46db-a180-b4c6ddd8ed02 Netherlands
3bd6648c-29e3-41bc-bc3a-93d519ff0fd7 Bulgaria
1bc9c8fd-2c4f-455a-9977-4887c7bdc5e9 Poland
e31abd8d-ff59-41c7-937b-62844b638e0d Germany
5ca5841d-38cb-43f9-95d0-d547b5cc1c12 Germany
c00b7270-a71e-4bd4-bc1e-dd67592b7405 Germany
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
195 mm
86 mm
230 mm
2.3 kg
7320500362655
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
114 mm
140 mm
45 mm
0.4 kg
Technical
208 ... 600 V AC
24 V AC/DC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 0.75 kW
(400 V) 1.5 kW
(500 V) 2.2 kW
(230 V) 0.75 kW
(400 V) 1.5 kW
(500 V) 2.2 kW
3.9 A
100 %
Recommended MS116 0.63 ... 4.00
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
No
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Screw Terminals
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
PSR3
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 0.5 Hp
(220 ... 240 V AC) Three Phase 0.75 Hp
(440 ... 480 V AC) Three Phase 2 Hp
(550 ... 600 V AC) Three Phase 2 Hp
(200 ... 208 V AC) Three Phase 0.5 Hp
(220 ... 240 V AC) Three Phase 0.75 Hp
(440 ... 480 V AC) Three Phase 2 Hp
(550 ... 600 V AC) Three Phase 2 Hp
Main Circuit 600 V
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
121 mm
50 mm
156 mm
0.5 kg
7320500477144
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
114 mm
140 mm
45 mm
0.4 kg
Technical
208 ... 600 V AC
24 V AC/DC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 1.5 kW
(400 V) 3 kW
(500 V) 4 kW
(230 V) 1.5 kW
(400 V) 3 kW
(500 V) 4 kW
6.8 A
100 %
Recommended MS116 4.00 ... 10.00
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
No
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Screw Terminals
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
PSR6
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 1 Hp
(220 ... 240 V AC) Three Phase 1.5 Hp
(440 ... 480 V AC) Three Phase 3 Hp
(550 ... 600 V AC) Three Phase 5 Hp
(200 ... 208 V AC) Three Phase 1 Hp
(220 ... 240 V AC) Three Phase 1.5 Hp
(440 ... 480 V AC) Three Phase 3 Hp
(550 ... 600 V AC) Three Phase 5 Hp
Main Circuit 600 V
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
121 mm
50 mm
156 mm
0.5 kg
7320500477151
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
114 mm
140 mm
45 mm
0.4 kg
Technical
208 ... 600 V AC
24 V AC/DC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 2.2 kW
(400 V) 4 kW
(500 V) 4 kW
(230 V) 2.2 kW
(400 V) 4 kW
(500 V) 4 kW
9 A
100 %
Recommended MS116 6.30 ... 10.00
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
No
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Screw Terminals
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
PSR9
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 2 Hp
(220 ... 240 V AC) Three Phase 2 Hp
(440 ... 480 V AC) Three Phase 5 Hp
(550 ... 600 V AC) Three Phase 7.5 Hp
(200 ... 208 V AC) Three Phase 2 Hp
(220 ... 240 V AC) Three Phase 2 Hp
(440 ... 480 V AC) Three Phase 5 Hp
(550 ... 600 V AC) Three Phase 7.5 Hp
Main Circuit 600 V
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
121 mm
50 mm
156 mm
0.5 kg
7320500477168
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
114 mm
140 mm
45 mm
0.4 kg
Technical
208 ... 600 V AC
24 V AC/DC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 3 kW
(400 V) 5.5 kW
(500 V) 5.5 kW
(230 V) 3 kW
(400 V) 5.5 kW
(500 V) 5.5 kW
12 A
100 %
Recommended MS132 10.00 ... 16.00
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
No
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Screw Terminals
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
PSR12
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 3 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 7.5 Hp
(550 ... 600 V AC) Three Phase 10 Hp
(200 ... 208 V AC) Three Phase 3 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 7.5 Hp
(550 ... 600 V AC) Three Phase 10 Hp
Main Circuit 600 V
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
121 mm
50 mm
156 mm
0.5 kg
7320500477175
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
114 mm
140 mm
45 mm
0.4 kg
Technical
208 ... 600 V AC
24 V AC/DC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 4 kW
(400 V) 7.5 kW
(500 V) 7.5 kW
(230 V) 4 kW
(400 V) 7.5 kW
(500 V) 7.5 kW
16 A
100 %
Recommended MS132 10.00 ... 16.00
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
No
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Screw Terminals
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 1 N·m
Supply Circuit 1 N·m
PSR16
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 3 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
(200 ... 208 V AC) Three Phase 3 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
Main Circuit 600 V
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Control Circuit 8.9 in·lb
Main Circuit 8.9
Supply Circuit 8.9 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
121 mm
50 mm
156 mm
0.5 kg
7320500477182
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
128 mm
160 mm
45 mm
0.6 kg
Technical
208 ... 600 V AC
24 V AC/DC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 5.5 kW
(400 V) 11 kW
(500 V) 15 kW
(230 V) 5.5 kW
(400 V) 11 kW
(500 V) 15 kW
25 A
100 %
Recommended MS132 20 ... 25
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
Yes
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Screw Terminals
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5
Control Circuit 0.6 N·m
Main Circuit 2.3 N·m
Supply Circuit 0.6 N·m
Control Circuit 0.6 N·m
Main Circuit 2.3 N·m
Supply Circuit 0.6 N·m
PSR25
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 7.5 Hp
(440 ... 480 V AC) Three Phase 15 Hp
(550 ... 600 V AC) Three Phase 20 Hp
(200 ... 208 V AC) Three Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 7.5 Hp
(440 ... 480 V AC) Three Phase 15 Hp
(550 ... 600 V AC) Three Phase 20 Hp
Main Circuit 600 V
Control Circuit 5.3 in·lb
Main Circuit 20.4
Supply Circuit 5.3 in·lb
Control Circuit 5.3 in·lb
Main Circuit 20.4
Supply Circuit 5.3 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
137 mm
50 mm
176 mm
0.7 kg
7320500477199
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
128 mm
160 mm
45 mm
0.6 kg
Technical
208 ... 600 V AC
24 V AC/DC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 7.5 kW
(400 V) 15 kW
(500 V) 18.5 kW
(230 V) 7.5 kW
(400 V) 15 kW
(500 V) 18.5 kW
30 A
100 %
Recommended MS132 25 ... 32
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
Yes
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Screw Terminals
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5
Control Circuit 0.6 N·m
Main Circuit 2.3 N·m
Supply Circuit 0.6 N·m
Control Circuit 0.6 N·m
Main Circuit 2.3 N·m
Supply Circuit 0.6 N·m
PSR30
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 25 Hp
(200 ... 208 V AC) Three Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 25 Hp
Main Circuit 600 V
Control Circuit 5.3 in·lb
Main Circuit 20.4
Supply Circuit 5.3 in·lb
Control Circuit 5.3 in·lb
Main Circuit 20.4
Supply Circuit 5.3 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
137 mm
50 mm
176 mm
0.7 kg
7320500477205
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
153 mm
187 mm
54 mm
1 kg
Technical
208 ... 600 V AC
24 V AC/DC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 7.5 kW
(400 V) 18.5 kW
(500 V) 22 kW
(230 V) 7.5 kW
(400 V) 18.5 kW
(500 V) 22 kW
37 A
100 %
Recommended MS450 28 ... 40
No
4xIe for 6s
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
40 ... 70 %
100 ... 60 %
No
No
Yes
Yes
No
No
Green
Green
Green
Green
10
FiledBusPlug(Optional)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Screw Terminals
Rigid 1x 6 ... 35 mm²
Rigid 2 x 6 ... 16 mm²
Rigid 1x 6 ... 35 mm²
Rigid 2 x 6 ... 16 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
1 x 0.75 ... 2.5 mm²
2 x 0.75 ... 2.5 mm²
Rigid 1/2 x 0.75 ... 2.5 mm²
Rigid 1 x 0.75 ... 2.5
Control Circuit 0.6 N·m
Main Circuit 4 N·m
Supply Circuit 0.6 N·m
Control Circuit 0.6 N·m
Main Circuit 4 N·m
Supply Circuit 0.6 N·m
PSR37
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
(200 ... 208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 25 Hp
(550 ... 600 V AC) Three Phase 30 Hp
(200 ... 208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 25 Hp
(550 ... 600 V AC) Three Phase 30 Hp
Main Circuit 600 V
Control Circuit 5.3 in·lb
Main Circuit 35.4
Supply Circuit 5.3 in·lb
Control Circuit 5.3 in·lb
Main Circuit 35.4
Supply Circuit 5.3 in·lb
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
163 mm
56 mm
217 mm
1.1 kg
7320500477212
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter
ABB industrial PLCs are the ultimate solution for modern businesses striving for efficiency, productivity, and unparalleled control. As a business owner, you know that every operation demands precision, consistency, and absolute reliability. That's why the brand has developed a powerful tool that will revolutionize the way you manage your industrial processes. With ABB PLCs, you'll unlock a world of limitless possibilities. Their cutting-edge technology ensures seamless integration, allowing you to effortlessly streamline your manufacturing operations. Say goodbye to the days of complicated manual controls and labor-intensive processes—these industrial PLC systems are here to simplify your operations and supercharge your business.
We at PLC Direct understand that you can’t rely on just any automation equipment to keep your facilities operating at their best. That’s why we make sure that we only feature products from top brands in our inventory. Whether you’re running a current ABB PLC model or an older one, we carry compatible replacements and parts to keep things moving smoothly. Shop with us today to find the perfect industrial PLC for your needs.
We at PLC Direct understand that you can’t rely on just any automation equipment to keep your facilities operating at their best. That’s why we make sure that we only feature products from top brands in our inventory. Whether you’re running a current ABB PLC model or an older one, we carry compatible replacements and parts to keep things moving smoothly. Shop with us today to find the perfect industrial PLC for your needs.