That’s why we at PLC Direct always set out to keep a diverse set of Siemens PLC hardware in stock. We especially stand by the brand’s PLC Siemens Simatic models for their commitment to customizability and constant improvability. Even if you require obsolete Siemens PLC parts or need a new PLC altogether, our selection of Siemens PLCs is exactly what you should seek out. Browse our collection below to assess this product’s availability and find something that works for your equipment. Once you find the right match, we can even get it to you without the unnecessary lead times. Shop here to learn more.
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU330, LIG, In=60A overload protection Ir=24A ...60A short circuit protection Ii=1,5...12 x In ground fault protection Ig=0,4... 1 x In, tg=0,1/0,3s w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU320, LI, In=60A overload protection Ir=24A ...60A short circuit protection Ii=1,5...12 x In w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU860, LSIG, In=150A overload protection Ir=60A ... 150A short circuit protection Isd=0,6..10x In, Ii=1,5..12x In neutral protection optional with ext. CT;up to160% ground fault protection Ig=0,2... 1 x In, tg=0,05-0,8s w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU350, LSI, In=150A overload protection Ir=60A ... 150A short circuit protection Isd=1,5... 10 x Ir, Ii=12 x In neutral protection adjustable(OFF; 50%; 100%) w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU330, LIG, In=150A overload protection Ir=60A ... 150A short circuit protection Ii=1,5...12 x In ground fault protection Ig=0,2... 1 x In, tg=0,1/0,3s w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU856, LSI, In=150A overload protection Ir=60A ... 150A short circuit protection Isd=0,6..10x In, Ii=1,5..12x In neutral protection adjustable(OFF; up to 100%) ground fault alarm alarm via EFB300 or COM w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU320, LI, In=150A overload protection Ir=60A ... 150A short circuit protection Ii=1,5...12 x In w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU856, LSI, In=150A overload protection Ir=60A ... 150A short circuit protection Isd=0,6..10x In, Ii=1,5..12x In neutral protection optional with ext. CT;up to160% ground fault alarm alarm via EFB300 or COM w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class M 35kA @ 480V 4-pole, line protection ETU550, LSI, In=100A overload protection Ir=40A...100A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) without connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU860, LSIG, In=150A overload protection Ir=60A ... 150A short circuit protection Isd=0,6..10x In, Ii=1,5..12x In neutral protection adjustable(OFF; up to 100%) ground fault protection Ig=0,2... 1 x In, tg=0,05-0,8s w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU860, LSIG, In=100A overload protection Ir=40A ... 100A short circuit protection Isd=0,6..10x In, Ii=1,5..12x In neutral protection adjustable(OFF; up to 150%) ground fault protection Ig=0,2... 1 x In, tg=0,05-0,8s w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU350, LSI, In=150A overload protection Ir=60A ... 150A short circuit protection Isd=1,5... 10 x Ir, Ii=12 x In w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU330, LIG, In=150A overload protection Ir=60A ... 150A short circuit protection Ii=1,5...12 x In neutral protection adjustable(OFF; 50%; 100%) ground fault protection Ig=0,2... 1 x In, tg=0,1/0,3s w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU350, LSI, In=100A overload protection Ir=40A ... 100A short circuit protection Isd=1,5... 10 x Ir, Ii=12 x In neutral protection adjustable(OFF; 50%; 100%) w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU320, LI, In=150A overload protection Ir=60A ... 150A short circuit protection Ii=1,5...12 x In neutral protection adjustable(OFF; 50%; 100%) w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU330, LIG, In=100A overload protection Ir=40A ... 100A short circuit protection Ii=1,5...12 x In neutral protection adjustable(OFF; 50%; 100%) ground fault protection Ig=0,2... 1 x In, tg=0,1/0,3s w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU856, LSI, In=100A overload protection Ir=40A ... 100A short circuit protection Isd=0,6..10x In, Ii=1,5..12x In neutral protection adjustable(OFF; up to 150%) ground fault alarm alarm via EFB300 or COM w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU856, LSI, In=100A overload protection Ir=40A ... 100A short circuit protection Isd=0,6..10x In, Ii=1,5..12x In neutral protection optional with ext. CT;up to160% ground fault alarm alarm via EFB300 or COM w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU860, LSIG, In=100A overload protection Ir=40A ... 100A short circuit protection Isd=0,6..10x In, Ii=1,5..12x In neutral protection optional with ext. CT;up to160% ground fault protection Ig=0,2... 1 x In, tg=0,05-0,8s w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU350, LSI, In=100A overload protection Ir=40A ... 100A short circuit protection Isd=1,5... 10 x Ir, Ii=12 x In w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU330, LIG, In=100A overload protection Ir=40A ... 100A short circuit protection Ii=1,5...12 x In ground fault protection Ig=0,2... 1 x In, tg=0,1/0,3s w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 4-pole, line protection ETU320, LI, In=100A overload protection Ir=40A ... 100A short circuit protection Ii=1,5...12 x In neutral protection adjustable(OFF; 50%; 100%) w/o connection
circuit breaker 3VA6 UL frame 150 breaking capacity class E 200 kA @ 480 V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A ... 100A short circuit protection Ii=1,5...12 x In w/o connection
circuit breaker 3VA5 UL frame 800 breaking capacity class C 100kA @ 480 V 4-pole, line protection TM230, FTAM, In=800A overload protection Ir=800A fixed short circuit protection Ii=5...10 x In