Schneider
Schneider

Schneider

25001 products

Showing 12961 - 12984 of 25001 products

Showing 12961 - 12984 of 25001 products
View
LV429051 Schneider Electric
Schneider LV429051 Schneider Electric
Sale price0.00 kr
Sold Out

trip unit TM80D for Compact NSX 100/160/250 circuit breakers, thermal magnetic, rating 80 A, 4 poles 4d

LV429052 Schneider Electric
Schneider LV429052 Schneider Electric
Sale price0.00 kr
Sold Out

This TM63D is a 4 poles 4d thermal-magnetic trip unit used on Compact NSX 100/160/250 circuit breakers. This 63A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.

Main

Characteristic Value(s)
Range ComPact
Range of Product ComPact NSX100...250 DC
ComPact NSX100...250
Product or Component Type Trip unit
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Range Compatibility ComPact NSX100
ComPact NSX160
ComPact NSX250
ComPact NSX100 DC
Device Application Distribution
Number of poles 4P
Protected poles description 4t
Neutral position Left
Trip unit protection functions LI
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rated current 63 A 104 °F (40 °C)
[Ue] rated operational voltage 690 V AC 50/60 Hz
750 V DC
Network type AC
DC
Network Frequency 50/60 Hz

Complementary

Characteristic Value(s)
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s 1.5 x In
15 s 6 x Ir
Short-time protection pick-up adjustment type Isd Fixed
[Isd] Short-time protection pick-up adjustment range 500 A
Short-time protection delay adjustment type tsd Fixed
Earth-leakage protection Without
Neutral protection settings 1 x Ir 4t)
LV429053 Schneider Electric
Schneider LV429053 Schneider Electric
Sale price 4,925.00 kr
Only 1 unit left

This TM50D is a 4 poles 4d thermal-magnetic trip unit used on Compact NSX 100/160 circuit breakers. This 50A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.

Main

Characteristic Value(s)
Range ComPact
Range of Product ComPact NSX100...250
ComPact NSX100...250 DC
Product or Component Type Trip unit
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Range Compatibility ComPact NSX100
ComPact NSX160
ComPact NSX100 DC
Device Application Distribution
Number of poles 4P
Protected poles description 4t
Neutral position Left
Trip unit protection functions LI
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rated current 50 A 104 °F (40 °C)
[Ue] rated operational voltage 690 V AC 50/60 Hz
750 V DC
Network type AC
DC
Network Frequency 50/60 Hz

Complementary

Characteristic Value(s)
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s 1.5 x In
15 s 6 x Ir
Short-time protection pick-up adjustment type Isd Fixed
[Isd] Short-time protection pick-up adjustment range 500 A
Short-time protection delay adjustment type tsd Fixed
Earth-leakage protection Without
Neutral protection settings 1 x Ir 4t)
LV429054 Schneider Electric
Schneider LV429054 Schneider Electric
Sale price 3,860.00 kr
Only 4 units left

This TM40D is a 4 poles 4d thermal-magnetic trip unit used on Compact NSX 100/160 circuit breakers. This 40A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.

Main

Characteristic Value(s)
Range ComPact
Range of Product ComPact NSX100...250
ComPact NSX100...250 DC
Product or Component Type Trip unit
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Range Compatibility ComPact NSX100
ComPact NSX160
ComPact NSX100 DC
Device Application Distribution
Number of poles 4P
Protected poles description 4t
Neutral position Left
Trip unit protection functions LI
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rated current 40 A 104 °F (40 °C)
[Ue] rated operational voltage 690 V AC 50/60 Hz
750 V DC
Network type AC
DC
Network Frequency 50/60 Hz

Complementary

Characteristic Value(s)
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s 1.5 x In
15 s 6 x Ir
Short-time protection pick-up adjustment type Isd Fixed
[Isd] Short-time protection pick-up adjustment range 500 A
Short-time protection delay adjustment type tsd Fixed
Earth-leakage protection Without
Neutral protection settings 1 x Ir 4t)
LV429055 Schneider Electric
Schneider LV429055 Schneider Electric
Sale price0.00 kr
Sold Out

This TM32D is a 4 poles 4d thermal-magnetic trip unit used on Compact NSX 100/160 circuit breakers. This 32A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.

Main

Characteristic Value(s)
Range ComPact
Range of Product ComPact NSX100...250
ComPact NSX100...250 DC
Product or Component Type Trip unit
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Range Compatibility ComPact NSX100
ComPact NSX160
ComPact NSX100 DC
Device Application Distribution
Number of poles 4P
Protected poles description 4t
Neutral position Left
Trip unit protection functions LI
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rated current 32 A 104 °F (40 °C)
[Ue] rated operational voltage 690 V AC 50/60 Hz
750 V DC
Network type AC
DC
Network Frequency 50/60 Hz

Complementary

Characteristic Value(s)
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s 1.5 x In
15 s 6 x Ir
Short-time protection pick-up adjustment type Isd Fixed
[Isd] Short-time protection pick-up adjustment range 400 A
Short-time protection delay adjustment type tsd Fixed
Earth-leakage protection Without
Neutral protection settings 1 x Ir 4t)
LV429056 Schneider Electric
Schneider LV429056 Schneider Electric
Sale price 3,150.00 kr
Only 1 unit left

trip unit TM25D for Compact NSX 100 circuit breakers, thermal magnetic, rating 25 A, 4 poles 4d

LV429057 Schneider Electric
Schneider LV429057 Schneider Electric
Sale price0.00 kr
Sold Out

This TM16D is a 4 poles 4d thermal-magnetic trip unit used on Compact NSX 100 circuit breakers. This 16A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.

Main

Characteristic Value(s)
Range ComPact
Range of Product ComPact NSX100...250 DC
ComPact NSX100...250
Product or Component Type Trip unit
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Range Compatibility ComPact NSX100
ComPact NSX100 DC
Device Application Distribution
Number of poles 4P
Protected poles description 4t
Neutral position Left
Trip unit protection functions LI
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rated current 16 A 104 °F (40 °C)
[Ue] rated operational voltage 690 V AC 50/60 Hz
750 V DC
Network type AC
DC
Network Frequency 50/60 Hz

Complementary

Characteristic Value(s)
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s 1.5 x In
15 s 6 x Ir
Short-time protection pick-up adjustment type Isd Fixed
[Isd] Short-time protection pick-up adjustment range 190 A
Short-time protection delay adjustment type tsd Fixed
Earth-leakage protection Without
Neutral protection settings 1 x Ir 4t)
LV429070 Schneider Electric
Schneider LV429070 Schneider Electric
Sale price 5,778.00 kr
Only 4 units left

This Micrologic 2.2 is a 3 poles 3d electronic trip unit used on Compact NSX 100/160/250 circuit breakers. This 100A rating electronic trip unit is an optimum choice for all standard and specific applications. It embeds an adjustable long time protection against overloads. It provides also an adjustable short-time protection and a fixed instantaneous protection against short-circuits. Micrologic 2.2 indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.

Main

Characteristic Value(s)
Range ComPact
Range of Product ComPact NSX100...250
Product or Component Type Trip unit
Trip unit name MicroLogic 2.2
Trip unit technology Electronic
Range Compatibility ComPact NSX100
ComPact NSX160
ComPact NSX250
Device Application Distribution
Number of poles 3P
Protected poles description 3t
Trip unit protection functions LSoI
Protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rated current 100 A 104 °F (40 °C)
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network Frequency 50/60 Hz

Complementary

Characteristic Value(s)
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 40...100 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 11 s 7.2 x Ir
16 s 6 x Ir
400 s 1.5 x Ir
Thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Fixed
[tsd] Short-time protection delay adjustment range 0.02 s
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 1500 A
Earth-leakage protection Without
Zone selective interlocking ZSI Without
Local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
LV429072 Schneider Electric
Schneider LV429072 Schneider Electric
Sale price 4,674.00 kr
Only 2 units left

trip unit Micrologic 2.2 for Compact NSX 100/160/250 circuit breakers, electronic, rating 40A, 3 poles 3d

LV429075 Schneider Electric
Schneider LV429075 Schneider Electric
Sale price0.00 kr
Sold Out

trip unit Micrologic 2.2 G for Compact NSX 100/160/250 circuit breakers, electronic, rating 100 A, 3 poles 3d

LV429076 Schneider Electric
Schneider LV429076 Schneider Electric
Sale price0.00 kr
Sold Out

This Micrologic 2.2 G is a 3 poles 3d electronic trip unit used on Compact NSX 100/160/250 circuit breakers. This 40A rating electronic trip unit is an optimum choice for generator protection applications. It embeds an adjustable long time protection against overloads. It provides also an adjustable short-time protection and a fixed instantaneous protection against short-circuits. Micrologic 2.2 G indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.

Main

Characteristic Value(s)
Range ComPact
Range of Product ComPact NSX100...250
Product or Component Type Trip unit
Trip unit name MicroLogic 2.2 G
Trip unit technology Electronic
Range Compatibility ComPact NSX100
ComPact NSX160
ComPact NSX250
Device Application Generator
Number of poles 3P
Protected poles description 3t
Trip unit protection functions LSoI
Protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rated current 40 A 104 °F (40 °C)
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network Frequency 50/60 Hz

Complementary

Characteristic Value(s)
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 18...40 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 15 s 1.5 x Ir
0.35 s 7.2 x Ir
0.5 s 6 x Ir
Thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable
[Isd] Short-time protection pick-up adjustment range 1.5...9 x Ir
Short-time protection delay adjustment type tsd Fixed
[tsd] Short-time protection delay adjustment range 0.14 s
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 600 A
Earth-leakage protection Without
Zone selective interlocking ZSI Without
Local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
LV429080 Schneider Electric
Schneider LV429080 Schneider Electric
Sale price 6,363.00 kr
Only 3 units left

trip unit Micrologic 2.2 for Compact NSX 100/160/250 circuit breakers, electronic, rating 100A, 4 poles 4d

LV429082 Schneider Electric
Schneider LV429082 Schneider Electric
Sale price0.00 kr
Sold Out

This Micrologic 2.2 is a 4 poles 4d electronic trip unit used on Compact NSX 100/160/250 circuit breakers. This 40A rating electronic trip unit is an optimum choice for all standard and specific applications. It embeds an adjustable long time protection against overloads. It provides also an adjustable short-time protection and a fixed instantaneous protection against short-circuits. Micrologic 2.2 indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.

Main

Characteristic Value(s)
Range ComPact
Range of Product ComPact NSX100...250
Product or Component Type Trip unit
Trip unit name MicroLogic 2.2
Trip unit technology Electronic
Range Compatibility ComPact NSX100
ComPact NSX160
ComPact NSX250
Device Application Distribution
Number of poles 4P
Protected poles description 3t
3t + N/2
4t
Neutral position Left
Trip unit protection functions LSoI
Protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rated current 40 A 104 °F (40 °C)
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network Frequency 50/60 Hz

Complementary

Characteristic Value(s)
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 18...40 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 11 s 7.2 x Ir
16 s 6 x Ir
400 s 1.5 x Ir
Thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Fixed
[tsd] Short-time protection delay adjustment range 0.02 s
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 600 A
Earth-leakage protection Without
Neutral protection settings 0.5 x Ir 3t + N/2)
1 x Ir 4t)
No protection 3t)
Zone selective interlocking ZSI Without
Local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
LV429085 Schneider Electric
Schneider LV429085 Schneider Electric
Sale price0.00 kr
Sold Out

trip unit Micrologic 2.2 G for Compact NSX 100/160/250 circuit breakers, electronic, rating 100 A, 4 poles 4d

LV429086 Schneider Electric
Schneider LV429086 Schneider Electric
Sale price0.00 kr
Sold Out

trip unit Micrologic 2.2 G for Compact NSX 100/160/250 circuit breakers, electronic, rating 40 A, 4 poles 4d

LV429089 Schneider Electric
Schneider LV429089 Schneider Electric
Sale price0.00 kr
Sold Out

trip unit Micrologic 5.2 A-Z for Compact NSX 100/160/250 circuit breakers, electronic, rating 100 A, 3 poles 3d

LV429090 Schneider Electric
Schneider LV429090 Schneider Electric
Sale price 4,132.00 kr
Only 3 units left

trip unit Micrologic 5.2 A for Compact NSX 100/160/250 circuit breakers, electronic, rating 100A, 3 poles 3d

LV429091 Schneider Electric
Schneider LV429091 Schneider Electric
Sale price 6,298.00 kr
Only 2 units left

This Micrologic 5.2 A (Ammeter) is a 3 poles 3d electronic trip unit used on Compact NSX 100/160/250 circuit breakers. This 40A rating electronic trip unit is an optimum choice for all standard and specific applications. It embeds adjustable long time protection against overloads. It provides also adjustable short-time protection and instantaneous protection against short-circuits. Micrologic 5.2 A indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. Micrologic 5.2 A is equipped with a display module that gives current measurement and allows fine adjustment settings. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.

Main

Characteristic Value(s)
Range ComPact
Range of Product ComPact NSX100...250
Product or Component Type Trip unit
Trip unit name MicroLogic 5.2 A
Trip unit technology Electronic
Range Compatibility ComPact NSX100
ComPact NSX160
ComPact NSX250
Device Application Distribution
Number of poles 3P
Protected poles description 3t
Trip unit protection functions LSI
Protection type L : for overload protection (long time)
S : for short time short-circuit protection
I : for instantaneous short-circuit protection
Trip unit rated current 40 A 104 °F (40 °C)
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network Frequency 50/60 Hz

Complementary

Characteristic Value(s)
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 18...40 A
Long-time protection delay adjustment type tr Adjustable
[tr] long-time protection delay adjustment range 15…400 s 1.5 x Ir
0.35…11 s 7.2 x Ir
0.5…16 s 6 x Ir
Thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Adjustable
[tsd] Short-time protection delay adjustment range 0…0.4 s I²t=off
0.1…0.4 s I²t=on
Instantaneous protection pick-up adjustment type Ii Adjustable
[Ii] instantaneous protection pick-up adjustment range 1.5...15 x In
Earth-leakage protection Without
Zone selective interlocking ZSI With
Local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Display Type LCD display
Type of Measurement Ammeter
Communication of data Maximeters/minimeters
Demand current and power
Maintenance indicators
Energy metering
Instantaneous and demand values
Protection and alarm settings
Power quality
Time-stamped histories and event tables
Electrical data recording Maintenance indicators
LV429095 Schneider Electric
Schneider LV429095 Schneider Electric
Sale price 13,511.00 kr
Only 2 units left

trip unit Micrologic 5.2 E for Compact NSX 100/160/250 circuit breakers, electronic, rating 100A, 3 poles 3d

LV429096 Schneider Electric
Schneider LV429096 Schneider Electric
Sale price 15,619.00 kr
Only 2 units left

trip unit Micrologic 5.2 E for Compact NSX 100/160/250 circuit breakers, electronic, rating 40A, 3 poles 3d

LV429100 Schneider Electric
Schneider LV429100 Schneider Electric
Sale price 3,729.00 kr
Only 1 unit left

This Micrologic 5.2 A (Ammeter) is a 4 poles 4d electronic trip unit used on Compact NSX 100/160/250 circuit breakers. This 100A rating electronic trip unit is an optimum choice for all standard and specific applications. It embeds adjustable long time protection against overloads. It provides also adjustable short-time protection and instantaneous protection against short-circuits. Micrologic 5.2 A indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. Micrologic 5.2 A is equipped with a display module that gives current measurement and allows fine adjustment settings. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.

Main

Characteristic Value(s)
Range ComPact
Range of Product ComPact NSX100...250
Product or Component Type Trip unit
Trip unit name MicroLogic 5.2 A
Trip unit technology Electronic
Range Compatibility ComPact NSX100
ComPact NSX160
ComPact NSX250
Device Application Distribution
Number of poles 4P
Protected poles description 3t + OSN
4t
3t + N/2
3t
Neutral position Left
Trip unit protection functions LSI
Protection type L : for overload protection (long time)
S : for short time short-circuit protection
I : for instantaneous short-circuit protection
Trip unit rated current 100 A 104 °F (40 °C)
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network Frequency 50/60 Hz

Complementary

Characteristic Value(s)
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 40...100 A
Long-time protection delay adjustment type tr Adjustable
[tr] long-time protection delay adjustment range 15…400 s 1.5 x Ir
0.35…11 s 7.2 x Ir
0.5…16 s 6 x Ir
Thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Adjustable
[tsd] Short-time protection delay adjustment range 0…0.4 s I²t=off
0.1…0.4 s I²t=on
Instantaneous protection pick-up adjustment type Ii Adjustable
[Ii] instantaneous protection pick-up adjustment range 1.5...15 x In
Earth-leakage protection Without
Neutral protection settings 0.5 x Ir 3t + N/2)
1 x Ir 4t)
1.6 x Ir 3t + OSN)
No protection 3t)
Zone selective interlocking ZSI With
Local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Display Type LCD display
Type of Measurement Ammeter
Communication of data Protection and alarm settings
Maximeters/minimeters
Instantaneous and demand values
Demand current and power
Maintenance indicators
Power quality
Energy metering
Time-stamped histories and event tables
Electrical data recording Maintenance indicators
LV429101 Schneider Electric
Schneider LV429101 Schneider Electric
Sale price 6,947.00 kr
Only 1 unit left

This Micrologic 5.2 A (Ammeter) is a 4 poles 4d electronic trip unit used on Compact NSX 100/160/250 circuit breakers. This 40A rating electronic trip unit is an optimum choice for all standard and specific applications. It embeds adjustable long time protection against overloads. It provides also adjustable short-time protection and instantaneous protection against short-circuits. Micrologic 5.2 A indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. Micrologic 5.2 A is equipped with a display module that gives current measurement and allows fine adjustment settings. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.

Main

Characteristic Value(s)
Range ComPact
Range of Product ComPact NSX100...250
Product or Component Type Trip unit
Trip unit name MicroLogic 5.2 A
Trip unit technology Electronic
Range Compatibility ComPact NSX100
ComPact NSX160
ComPact NSX250
Device Application Distribution
Number of poles 4P
Protected poles description 3t + N/2
3t + OSN
3t
4t
Neutral position Left
Trip unit protection functions LSI
Protection type L : for overload protection (long time)
S : for short time short-circuit protection
I : for instantaneous short-circuit protection
Trip unit rated current 40 A 104 °F (40 °C)
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network Frequency 50/60 Hz

Complementary

Characteristic Value(s)
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 18...40 A
Long-time protection delay adjustment type tr Adjustable
[tr] long-time protection delay adjustment range 15…400 s 1.5 x Ir
0.35…11 s 7.2 x Ir
0.5…16 s 6 x Ir
Thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Adjustable
[tsd] Short-time protection delay adjustment range 0…0.4 s I²t=off
0.1…0.4 s I²t=on
Instantaneous protection pick-up adjustment type Ii Adjustable
[Ii] instantaneous protection pick-up adjustment range 1.5...15 x In
Earth-leakage protection Without
Neutral protection settings 0.5 x Ir 3t + N/2)
1 x Ir 4t)
1.6 x Ir 3t + OSN)
No protection 3t)
Zone selective interlocking ZSI With
Local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Display Type LCD display
Type of Measurement Ammeter
Communication of data Maximeters/minimeters
Power quality
Time-stamped histories and event tables
Energy metering
Demand current and power
Maintenance indicators
Protection and alarm settings
Instantaneous and demand values
Electrical data recording Maintenance indicators
LV429105 Schneider Electric
Schneider LV429105 Schneider Electric
Sale price0.00 kr
Sold Out

This Micrologic 5.2 E (Energy) is a 4 poles 4d electronic trip unit used on Compact NSX 100/160/250 circuit breakers. This 100A rating electronic trip unit is an optimum choice for all standard and specific applications. It embeds adjustable long time protection against overloads. It provides also adjustable short-time protection and instantaneous protection against short-circuits. Micrologic 5.2 E indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. Micrologic 5.2 E is equipped with a display module that gives energy measurement and allows fine adjustment settings. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.

Main

Characteristic Value(s)
Range ComPact
Range of Product ComPact NSX100...250
Product or Component Type Trip unit
Trip unit name MicroLogic 5.2 E
Trip unit technology Electronic
Range Compatibility ComPact NSX100
ComPact NSX160
ComPact NSX250
Device Application Distribution
Number of poles 4P
Protected poles description 3t + N/2
3t + OSN
4t
3t
Neutral position Left
Trip unit protection functions LSI
Protection type L : for overload protection (long time)
S : for short time short-circuit protection
I : for instantaneous short-circuit protection
Trip unit rated current 100 A 104 °F (40 °C)
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network Frequency 50/60 Hz

Complementary

Characteristic Value(s)
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 40...100 A
Long-time protection delay adjustment type tr Adjustable
[tr] long-time protection delay adjustment range 15…400 s 1.5 x Ir
0.35…11 s 7.2 x Ir
0.5…16 s 6 x Ir
Thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Adjustable
[tsd] Short-time protection delay adjustment range 0…0.4 s I²t=off
0.1…0.4 s I²t=on
Instantaneous protection pick-up adjustment type Ii Adjustable
[Ii] instantaneous protection pick-up adjustment range 1.5...15 x In
Earth-leakage protection Without
Neutral protection settings 0.5 x Ir 3t + N/2)
1 x Ir 4t)
1.6 x Ir 3t + OSN)
No protection 3t)
Zone selective interlocking ZSI With
Local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Display Type LCD display
Type of Measurement Energy meter
Communication of data Instantaneous and demand values
Maintenance indicators
Energy metering
Demand current and power
Maximeters/minimeters
Time-stamped histories and event tables
Power quality
Protection and alarm settings
Electrical data recording Maintenance indicators
LV429106 Schneider Electric
Schneider LV429106 Schneider Electric
Sale price 3,886.00 kr
Only 1 unit left

trip unit Micrologic 5.2 E for Compact NSX 100/160/250 circuit breakers, electronic, rating 40A, 4 poles 4d

Recently viewed