SIPLUS CP 1543-1 -40 ... + 60 °C STARTUP -25 °C WITH CONFORMAL COATING BASED ON 6GK7543-1AX00-0XE0 COMMUNICATION PROCESSOR TO CONNECT SIMATIC S7-1500 WITH INDUSTRIAL ETHERNET: TCP/IP, ISO, UDP, S7- COMMUNICATION, IP-BROADCAST/ MULTICAST, SECURITY (HARDWARE- IDENTIFICATION, IP/MAC ACCESS- LIST, FIREWALL), DIAGNOSIS SNMPV1/V3, DHCP, FTP CLIENT/ SERVER, E-MAIL, IPV4/IPV6, DATA STORAGE ON SD-CARD IN THE CPU, TIME SYNCHRONISATION OVER NTP, ACCESS TO THE WEBSERVER OF THE CPU;GIGABIT-SS 1XRJ45 (10/100/1000 MBIT)

SIMATIC S7-1500F, CPU 1511F-1 PN, Central processing unit with work memory 225 KB for program and 1 MB for data, 1st interface: PROFINET IRT with 2-port switch, 60 ns bit performance, SIMATIC Memory Card required

SIMATIC S7-1500 Compact CPU CPU 1511C-1 PN, central processing unit with work memory 175 KB for program and 1 MB for data, 16 digital inputs, 16 digital outputs, 5 analog inputs, 2 analog outputs, 6 high-speed counters, 4 high-speed counters for PTO/PWM/frequency output 1st interface: PROFINET IRT with 2-port switch, 60 ns bit performance, incl. push-in front connector

SIMATIC S7-1500F, CPU 1513F-1 PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 450 KB FOR PROGRAM AND 1.5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 40 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY

***60 years of SIMATIC*** SIMATIC S7-1500, starter kit Consisting of: CPU 1511C-1 PN, power supply PM1507, 24 V/3 A, mounting rail 160 mm, SIMATIC Memory Card, 4 MB, Ethernet cable, STEP 7 V16 Professional Trial365 license, SIMATIC ProDiag S7-1500, SIMATIC OPC UA S7-1500 Small, information material

SIMATIC S7-300 CPU319F-3 PN/DP, Central processing unit with 1400 KB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface DP master/slave 3rd interface Ethernet PROFINET, Micro Memory Card required Can be used with software package Distributed Safety from V5.4 SP3

SIPLUS S7-1500 CPU 1516-3 PN/DP -40 ... +60 GRAD C STARTUP -20 GRAD C WITH CONFORMAL COATING BASED ON 6ES7516-3AN01-0AB0 . CENTRAL PROCESSING UNIT WITH WORKING MEMORY 1 MB FOR PROGRAM AND 5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: ETHERNET, 3. INTERFACE: PROFIBUS, 10 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY

SIMATIC S7-300 CPU 319-3 PN/DP, CENTRAL PROCESSING UNIT WITH 2 MBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE DP-MASTER/SLAVE, 3. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY

SIMATIC S7-1500, STARTERKIT, CONSISTIG OF: CPU 1511-1 PN, DI 16X 24VDC HF, DQ 16X 24VDC/0.5A ST, POWER SUPPLY PM1507, 24V/3A, MOUNTING RAIL 160MM, SIMATIC MEMORY CARD, 4 MB, FRONTCONNECTOR, ETHERNET CABLE. STEP 7 V13 SP1 PROFESSIONAL TRIAL365-LICENSE, INFO MATERIAL, IN SYSTAINER

SIPLUS S7-1500 CPU 1516-3 PN/DP -40 ... +70 GRAD C STARTUP -20 GRAD C WITH CONFORMAL COATING BASED ON 6ES7516-3AN01-0AB0 . CENTRAL PROCESSING UNIT WITH WORKING MEMORY 1 MB FOR PROGRAM AND 5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: PROFINET RT, 3. INTERFACE: PROFIBUS, 10 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY

SIPLUS S7-1500 CPU 1518F-4 PN/DP WITH CONFORMAL COATING BASED ON 6ES7518-4FP00-0AB0 . CENTRAL PROCESSING UNIT WITH WORKING MEMORY 4,5 MB FOR PROGRAM AND 10 MB FOR DATA, 1. INTERFACE, PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE, ETHERNET, 3. INTERFACE, ETHERNET, 4. INTERFACE, PROFIBUS, 1 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY

SIMATIC S7-1500, CPU 1511-1 PN, Central processing unit with Work memory 150 KB for program and 1 MB for data, 1st interface, PROFINET IRT with 2-port switch, 60 ns bit performance, SIMATIC Memory Card required

Simatic S7-300 CPU319F-3 PN/DP, Central PROCESSING Unit with 2.5 MBYTE WORKING Memory, 1. Interface MPI/DP 12MBIT/S, 2. Interface DP-MASTER/Slave, 3. Interface ETHERNET PROFINET, with 2 PORT Switch, MICRO Memory Card NECESSARY

Simatic S7-300, CPU 317TF-3 PN/DP, Central PROCESSING Unit FOR PLC, TECHNOLOGY and SAFETY, 1,5 MBYTE WORKING Memory, 1. Interface MPI/DP 12MBIT/S, 2. Interface DP(DRIVE), 3. Interface ETHERNET PROFINET with 2 PORT Switch, Integrated I/O FOR TECHNOLOGY, Front CONNECTOR (1 X 40PIN) and MICRO Memory Card MIN. 8 MB NECESSARY

SIMATIC S7-300, CPU 317T-2 DP, Central processing unit for PLC and Technology tasks, 1024 KB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface DP (drive), Integr. I/O for technology Front connector (1x 40-pole) and Micro Memory Card min. 8 MB required

SIMATIC S7-300, CPU 317T-2 DP, CENTRAL PROCESSING UNIT FOR PLC AND TECHNOLOGY 512 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S 2. INTERFACE DP(DRIVE), INTEGRATED I/O FOR TECHNOLOGY FRONT CONNECTOR (1 X 40PIN) AND MICRO MEMORY CARD MIN. 4MB NECESSARY

SIMATIC S7-300, CPU 317F-2DP, Central processing unit with 1024 KB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface DP master/slave Micro Memory Card required Can be used with software package S7 Distributed Safety V5.2 SP1 or higher

SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL -40 ... +70 Degree C TX with 85 Degree C for 10 min with Conformal Coating BasedOn 6ES7516-3AN01-0AB0 . Central Processing Unit without Display with working memory 1 MB for Program and 5 MB for Data, 1. Interface: PROFINET IRT with 2 Port Switch, 2. Interface: ETHERNET, 3. Interface: PROFIBUS, 10 NS Bit-Performance, SIMATIC Memory Card necessary

VICOS RTU, TIM 3V BN TRANSMISSION PROCESSOR FOR SIMATIC S7-300 WITH RS232/RS485 INTERFACE FOR EXT. MODEM/RADIO DEVICE FOR APPLICATIONS WITH SPECIAL DRIVERS

SIPLUS S7-1500 CPU 1516F-3 PN/DP T1 RAIL -25 ... +55°C T1 70°C für 10 min with conformal coating based on 6ES7516-3FN01-0AB0 . central processing unit with working memmory 1,5 MB for programm 5 MB for data, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: ETHERNET 3. INTERFACE: PROFIBUS, 10 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY