Antenna cable, outside diameter: 2.5�mm (0.1�in.), inner conductor: stranded, attenuation: 0.9�dB at 900�MHz, connection: MCX (male) -> N (female), cable length: 1.2�m (4�ft.)
Antenna cable, outside diameter: 2.5mm (0.1in.), inner conductor: stranded, attenuation: 0.9dB at 900MHz, connection: SMA (male) -> N (male), cable length: 1.2m (4ft.)
Antenna cable, outside diameter: 10�mm (0.4�in.), inner conductor: solid, attenuation: 3.3 / 5.6 / 8.4�dB at 0.9 / 2.4 / 5.8�GHz, connection: 2x N (male), cable length: 24�m (80�ft.)
Analog /digital module for 2 digital inputs/outputs and 1 analog input/output
Antenna cable, outside diameter: 2.5�mm (0.1�in.), inner conductor: stranded, attenuation: 0.9�dB at 900�MHz, connection: MCX (male) -> N (male), cable length: 1.2�m (4�ft.)
Antenna cable, outside diameter: 10mm (0.4in.), inner conductor: solid, attenuation: 4.1 / 6.9 / 10.4dB at 0.9 / 2.4 / 5.8GHz, connection: 2x N (male), cable length: 30m (100ft.)
Antenna cable, outside diameter: 10�mm (0.4�in.), inner conductor: solid, attenuation: 3.5�dB at 900�MHz, connection: 2 x N (male), cable length: 15�m (50�ft.)
Omnidirectional antenna, 900�MHz, gain: 7�dBi, polarization: linear, opening angle: h/v 360�/30�, degree of protection: IP65, connection: N (female), incl. mounting bracket and mast clips
Omnidirectional antenna, 900�MHz, gain: 5�dBi, polarization: linear, opening angle: h/v 360�/28�, degree of protection: IP65, connection: N (female), incl. mounting bracket and mast clips
Analog extension module with 4 analog current outputs 4 mA ... 20mA
Energy storage device, lead AGM, VRLA technology, 24 V DC, 0.8 Ah.
Antenna cable, outside diameter: 10�mm (0.4�in.), inner conductor: solid, attenuation: 2.5 / 4.2 / 6.3�dB at 0.9 / 2.4 / 5.8�GHz, connection: 2x N (male), cable length: 18�m (60�ft.)
Antenna cable, outside diameter: 10�mm (0.4�in.), inner conductor: solid, attenuation: 2.9�dB at 900�MHz, connection: 2 x N (male), cable length: 12�m (40�ft.)
Monitoring relay for temperature monitoring of the motor winding (maximum 6 PTC) with error memory for temperature sensors in acc. with DIN 44081, test function with integrated test/reset button, supply voltage can be selected using power module, 2 PDTs
Monitoring relay for monitoring phase sequence, phase failure and asymmetry, 342 ... 457 V AC, supply from measurement supply, 2 PDTs
Omnidirectional antenna, 900�MHz, gain: 2�dBi, polarization: linear, opening angle: h 360�, degree of protection: IP65, connection: MCX (male), incl. 2�m / 6.5�ft. connecting cable and mounting bracket for wall mounting
Input Module DIN Rail 9 - 30VDC
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 25�mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Screw connection.
Ex i temperature transducer: converts measured values from resistance thermometers installed in the Ex area to a 0/4 mA 20 mA signal for driving a non-intrinsically safe load. Freely programmable. 3-way electrical isolation.
Ex i solenoid driver, pluggable. To control intrinsically safe solenoid valves, alarm modules as well as simple electric equipment installed in Ex areas. For Group IIC gases, loop-powered. Electrical isolation.
Ex i motherboard for accommodating 16 x PI-Ex supply, input or output signal conditioner modules. With interface for connecting to HART multiplexer and D-SUB pin strip for connecting the analog signals to the control system level.
Ex i solenoid driver, pluggable. To control intrinsically safe solenoid valves, alarm modules as well as simple electric equipment installed in Ex areas. For Group IIC gases, loop-powered. Electrical isolation.