SmartWire DT adapter for CONTACTRON hybrid motor starters, with "Enable" input for safe shutdown up to PLe/SIL�3.
D-SUB plug, 9-pos., socket, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands (A-coded) under 90. Bus system: CAN, CANopen. Termination resistor via separate M12 terminator. Long version; S7-compatible.
Adapter for mounting short-circuit proof hybrid motor starters of type ELR-H51 ... on 60 mm power busbars. Classic design with 200 mm design height.
D-SUB plug, 9-pos., pin, assignment: 3, 5, 6, 8; two M12 cable glands (B-coded) under 90. Bus system: PROFIBUS DP up to 12 Mbps. Termination resistor via separate M12 terminator. Long version; S7-compatible.
D-SUB plug, 9-pos., pin, with PG-D-SUB socket, assignment: 3, 5, 6, 8; two M12 cable glands (B-coded) under 90. Bus system: PROFIBUS DP up to 12 Mbps. Termination resistor via separate M12 terminator. Long version; S7-compatible.
Industrial ADSL broadband router/modem with integrated firewall and NAT function. The device supports the standards Annex�A, B, and J (ALL-IP connections of Deutsche Telekom). Annex�J as of firmware v1.05.4
D-SUB plug, 9-pos., socket, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands (A-coded) under 180 (axial). Bus system: CAN, CANopen. Termination resistor via separate M12 terminator.
Constant voltage source, input voltage 9.6 - 30 V DC, output voltage 10 V, 7.5 V, 5 V, 2.5 V DC, electrically isolated, can be configured via DIP switches, screw connection technology, standard configuration
D-SUB plug, 9-pos., socket, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands (A-coded) under 35. Bus system: CAN, CANopen. Termination resistor via separate M12 terminator.
D-SUB plug, 9-pos., pin, assignment: 3, 5, 6, 8; two M12 cable glands (B-coded) under 35. Bus system: PROFIBUS DP up to 12 Mbps. Termination resistor via separate M12 terminator.
Adapter for mounting short circuit-proof hybrid motor starters of type ELR-H51 ... on 35 mm DIN rails.
Industrial ADSL broadband router/modem with RS-232, integrated firewall, NAT and VPN support (IPsec, OpenVPN). The device supports the standards Annex�A, B, and J (ALL-IP connections of Deutsche Telekom). Annex J as of firmware v1.05.4
Plug-in module for extending a relay module to create a timer relay, 3 time functions, 4 time ranges, for mounting on RIF-1, RIF-2, RIF-3, and RIF-4, input voltage: 12...24VDC
D-SUB plug, 9-pos., socket, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands (A-coded) under 90. Bus system: CAN, CANopen. Termination resistor via separate M12 terminator.
D-SUB plug, 9-pos., pin, assignment: 3, 5, 6, 8; two M12 cable glands (B-coded) under 180 (axial). Bus system: PROFIBUS DP up to 12 Mbps. Termination resistor via separate M12 terminator.
D-SUB plug, 9-pos., pin, assignment: 3, 5, 6, 8; two M12 cable glands (B-coded) under 90. Bus system: PROFIBUS DP up to 12 Mbps. Termination resistor via separate M12 terminator.
D-SUB plug, 9-pos., pin, with PG-D-SUB socket, assignment: 3, 5, 6, 8; two M12 cable glands (B-coded) under 90. Bus system: PROFIBUS DP up to 12 Mbps. Termination resistor via separate M12 terminator.
VARIOFACE front adapter, for Honeywell FC-RUSIO-3224, specifically for connection to the TC-D37SUB-ADIO16-EX-A-RUSIO 2904967 termination carrier. Transmission of 16 channels.
DIN rail adapter for EEM-MA600 and EEM-MA400 energy meters
Assembled shielded round cable connection 1: D-SUB socket strip (1x 37-position) connection 2: D-SUB socket strip (1x 37-position) cable length: 40 m
D-SUB plug, 9-pos., pin, with PG-D-SUB socket, assignment: 3, 5, 6, 8; two M12 cable glands (B-coded) under 35. Bus system: PROFIBUS DP up to 12 Mbps. Termination resistor via separate M12 terminator.
Assembled shielded round cable connection 1: D-SUB socket strip (1x 37-position) connection 2: D-SUB socket strip (1x 37-position) cable length: 35 m
Assembled shielded round cable connection 1: D-SUB socket strip (1x 37-position) connection 2: D-SUB socket strip (1x 37-position) cable length: 25 m
Power terminal with plug-in connection technology for delivering the supply voltage to the DIN rail connector. Monitoring of the supply voltages in combination with the fault monitoring module. Push-in connection technology