Axioline�F bus coupler for PROFINET (including bus base module and connector)
Axioline�E, Digital I/O device, Sercos, M12 fast connection technology, Digital inputs:�8, 24 V�DC, connection method:�4-wire, Digital outputs:�4, 24 V�DC, 2 A, connection method:�3-wire, Metal housing, degree of protection:�IP65/IP67
Axioline�E, Digital I/O device, Sercos, M12 fast connection technology, Digital inputs:�16, 24 V�DC, connection method:�4-wire, Digital outputs:�16, 24 V�DC, 500 mA, connection method:�3-wire, Metal housing, degree of protection:�IP65/IP67
Axioline�E digital output device via IO-Link in a plastic housing with 1�IO-Link port and 8 outputs, 24�V�DC, 500 mA, 3 wire technology, M12 fast connection technology
Axioline�E digital input device via IO-Link in plastic housing with an�IO-Link A-port and eight inputs, 24�V�DC, 4-conductor technology, M12 fast connection technology
Axioline�E digital input device via IO-Link in plastic housing with an�IO-Link A-port and 16 inputs, 24�V�DC, 4-conductor technology, M12 fast connection technology
Axioline P, PROFINET, RJ45 socket, auto negotiation and auto crossing, transmission speed in the local bus:�100 Mbps
Axioline F, function module, pulse width modulation, transmission speed in local bus 100 Mbps, IP20 degree of protection, including bus base module and Axioline F male connectors
Axioline F, Digital output module, Digital outputs: 16, 24 V DC, 500 mA, connection method: 3-wire, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
Axioline F, Digital I/O module, Digital inputs: 8, 24 V DC, connection method: 3-wire, Digital outputs: 8, 24 V DC, 500 mA, connection method: 3-wire, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
Axioline F XC, Temperature recording module, Analog inputs: 8 (for resistance temperature detectors), connection method: 2, 3, 4-wire (shielded), transmission speed in the local bus: 100 Mbps, Extreme�conditions version, degree of protection: IP20, including bus base module and Axioline�F connectors
Axioline F XC, Temperature recording module, Analog inputs: 4 (for resistance temperature detectors), connection method: 2, 3, 4-wire (shielded), transmission speed in the local bus: 100 Mbps, Extreme�conditions version, degree of protection: IP20, including bus base module and Axioline�F connectors
Axioline F XC, Digital output module, Digital outputs:�16, 24 V�DC, 500 mA, connection method:�3-wire, Extreme�conditions version, transmission speed in the local bus:�100 Mbps, degree of protection:�IP20, including bus base module and Axioline�F connectors
Axioline F XC, Digital output module, Digital outputs:�8, 24 V�DC, 2 A, connection method:�2-wire, Extreme�conditions version, transmission speed in the local bus:�100 Mbps, degree of protection:�IP20, including bus base module and Axioline�F connectors
Axioline F XC, Digital input module, Digital inputs:�32, 24 V�DC, connection method:�1-wire, Extreme�conditions version, transmission speed in the local bus:�100 Mbps, degree of protection:�IP20, including bus base module and Axioline�F connectors
Axioline F XC, Digital input module, Digital inputs:�16, 24 V�DC, connection method:�4-wire, Extreme�conditions version, transmission speed in the local bus:�100 Mbps, degree of protection:�IP20, including bus base module and Axioline�F connectors
Axioline F XC, Analog output module, Analog outputs: 8, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-wire, transmission speed in the local bus: 100 Mbps, Extreme�conditions version, degree of protection: IP20, including bus base module and Axioline�F connectors
Axioline F XC, Analog output module, Analog outputs: 4, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, connection method: 2-wire, transmission speed in the local bus: 100 Mbps, Extreme�conditions version, degree of protection: IP20, including bus base module and Axioline�F connectors
Axioline F XC, Analog input module, Analog inputs: 8, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-wire, transmission speed in the local bus: 100 Mbps, Extreme�conditions version, degree of protection: IP20, including bus base module and Axioline�F connectors
Axioline F XC, Analog input module, Analog inputs: 4, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2, 3, 4-wire, transmission speed in the local bus: 100 Mbps, integrated sensor supply, Extreme�conditions version, degree of protection: IP20, including bus base module and Axioline�F connectors
Axioline F XC, Analog I/O module, Analog inputs: 2, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-wire, Analog outputs: 2, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-wire, transmission speed in the local bus: 100 Mbps, Extreme�conditions version, degree of protection: IP20, including bus base module and Axioline�F connectors
AXC F 2152 starter kit including PLCnext Control AXC F 2152, voltage switch, digital input and output module, analog input and output module, potentiometer, switch module, PROFICLOUD license, as well as a power supply unit, patch cable, country-specific adapter plugs, and documentation.
Axiocontrol for the direct control of Axioline�F I/Os. With 3 Ethernet interfaces for the additional connection of distributed I/Os via PROFINET, Modbus TCP or TCP/IP. Programming according to IEC 61131-3. Includes connector plug and marking field.
AXC 1050 XC - 2701295 PHOENIX CONTACT CONTROL LOGIC 24V