Freely configurable safety module with 20 safe inputs and 4 safe outputs; 4 alarm, 2 clock, and 2 ground switching outputs; can be extended with additional I/O modules, up to SILCL 3, Cat.4/PL e, SIL 3, EN 50156, plug-in screw connection terminal blocks
Freely configurable safety module with 20 safe inputs and 4 safe outputs, 4 signal, 2 clock, and 2 ground switching outputs; diagnostics possible via bus gateways, up to SILCL 3, Cat. 4/PL e, SIL 3, EN 50156, pluggable Push-in terminal block
Four-channel HART expansion module, with screw connection, with internal input resistors
Four-channel HART� expansion module, with screw connection
Four-channel digital input and four-channel digital output module with screw connection
Foundation Fieldbus isolator for Zone 2 installation using the intrinsically safe [ic] protection method.
FO converter, for converting 100Base-T to polymer and PCF fiber (660�nm), SC-RJ FO connection (PROFINET standard), can be mounted on a DIN rail, 24�V�DC supply
FO converter with ST fiber optic connection (1300�nm), for converting 100Base-TX to multi-mode fiberglass. Auto MDI(X) function and comprehensive link diagnostics. DIN rail mountable.
FO converter with ST fiber optic connection (1300�nm), for converting 100Base-TX to multi-mode fiberglass. Auto MDI(X) function and comprehensive link diagnostics. DIN rail mountable with wide operating temperature range.
FO converter with SC duplex fiber optic connection (1300�nm), for converting 100Base-TX to single mode fiberglass with a maximum FO segment length of 20�km. Auto MDI(X) function and comprehensive link diagnostics. DIN rail mountable with wide operating temperature range.
FO converter with SC duplex fiber optic connection (1300�nm), for converting 100Base-TX to multi-mode fiberglass. Auto MDI(X) function and comprehensive link diagnostics. DIN rail mountable.
FO converter with SC duplex fiber optic connection (1300�nm), for converting 100Base-TX to multi-mode fiberglass. Auto MDI(X) function and comprehensive link diagnostics. DIN rail mountable with wide operating temperature range.
FO converter with SC duplex fiber optic connection (1300�nm) for converting 100Base-TX to single mode fiberglass with a maximum FO segment length of 40�km. Auto MDI(X) function and comprehensive link diagnostics. DIN rail mountable with wide operating temperature range.
FO converter with SC duplex fiber optic connection (1300 nm), for converting 10/100Base-T(X) to single mode fiberglass (9/125 �m). Auto negotiation and auto MDI(X) function. Comprehensive link diagnostics. DIN-rail mountable, 18 ... 30 V DC supply.
FO converter with SC duplex fiber optic connection (1300 nm), for converting 10/100Base-T(X) to multi-mode fiberglass (50/125 �m). Auto negotiation and auto MDI(X) function. Comprehensive link diagnostics. DIN-rail mountable, 18 ... 30 V DC supply.
FO converter with LC duplex fiber optic connection (1300 nm), for converting 100Base-TX to single mode fiberglass. Auto MDI(X) function. Comprehensive link diagnostics. DIN rail mountable, 12 ... 57 V DC supply. Meets IEC�61850-3 and IEEE�1613 standards.
FO converter with LC duplex fiber optic connection (1300 nm), for converting 100Base-TX to multi-mode fiberglass. Auto MDI(X) function. Comprehensive link diagnostics. DIN rail mountable, 12 ... 57 V DC supply. Meets IEC�61850-3 and IEEE�1613 standards.
FO converter with integrated optical diagnostics, for DeviceNet, CAN, CANopen up to 800 kbps, extension/redundancy module, interfaces: 1 x FO (BFOC), 850 nm, for PCF/fiberglass cable (multimode)
FO converter with integrated optical diagnostics, for DeviceNet, CAN, CANopen up to 800 kbps, basic module, interfaces: 1 x CAN, 1 x alarm, 1 x FO (FSMA), 660 nm, for polymer/PCF fiberglass cable
FO converter with integrated optical diagnostics, for DeviceNet, CAN, CANopen up to 800 kbps, basic module, interfaces: 1 x CAN, 1 x alarm, 1 x FO (BFOC), 850 nm, for PCF/fiberglass cable (multimode)
FO converter with integrated optical diagnostics, coated PCB, alarm contact, for PROFIBUS up to 12�Mbps, T-coupler with two FO interfaces (BFOC), 850�nm, for PCF or fiberglass cable (multimode)
FO converter with integrated optical diagnostics, coated PCB, alarm contact, for PROFIBUS up to 12�Mbps, T-coupler with two FO interfaces (BFOC), 850�nm, for PCF or fiberglass cable (multimode)
FO converter with integrated optical diagnostics, alarm contact, for RS-485 2-wire bus systems (SUCONET K, MODBUS ...) up to 500 kbps, NRZ coding, termination device with an FO interface (SC-Duplex), 1300 nm, for fiberglass cable
FO converter with integrated optical diagnostics, alarm contact, for RS-485 2-wire bus systems (SUCONET K, Modbus ...) up to 500 kbps, NRZ coding, terminal device with one FO interface (FSMA), 660 nm, for polymer/PCF fiber cable