SET OF 2 ROUND-HEAD BOLT GUIDES MAX. LOAD IN AXIAL DIRECTION 250 KN, WITH 2 OUTER BEARING BLOCKS
SET OF 2 ROUND-HEAD BOLT GUIDES MAX. LOAD IN AXIAL DIRECTION 500 KN, WITH INNER BEARING BLOCK
Digital display for SITRANS TF
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep
SITRANS P220 Transmitters for pressure and absolute pressure fully welded version for high-pressure and refrigerant applications Non-linearity: 0,25 Percent (typically) wetted parts material: stainless steel; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 160 bar, Overload- pressure 400 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Standard version Standard version
SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure applications Non-linearity: 0,25 percent (typically) wetted parts material: stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 600 mbar, Overload- pressure 2000 mbar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V with Explosion protection: EEx ia IIC T4 Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
SITRANS FC 300 . DN4 W2.4602/Hastelloy C22 (115C) PN410 G 1/4 Inch, ISO 228-1 Pipe thread Standard NONE 5 m. Cable Standard Calibration 3 flow x 2 points
SITRANS FC 300 . DN4 W1.4435/316L (115C) PN130 G 1/4 Inch, ISO 228-1 Pipe thread Standard NONE 5 m. Cable Standard Calibration 3 flow x 2 points
SITRANS FC 300 . DN4 W1.4435/316L (115C) PN130 G 1/4 Inch, ISO 228-1 Pipe thread Standard NONE 25 m. Cable Standard Calibration 3 flow x 2 points
SITRANS F C MASSFLO MASS2100 Standard without heating jacket . DI3 W2.4602/Hastelloy C22 PN350 G 1/4 Inch, ISO 228-1 Pipe thread Configuration: Standard no transmitter 25 m (82 ft) Cable Standard Calibration 3 flow x 2 points
SITRANS FM MAG 3100 Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 2000 (1/2" to 78"). Suitable for volume flow measurement of liquids (conductive), main applications in process industry, chemical industry, steel industry, mining, utility, power generation and distribution, O&G/HPI. . DN100, 4 Inch EN1092-1, PN6 Carbon steel flanges ASTM A 105, corrosion-resistant coating of category C4 Soft Rubber Stainless steel AISI 316Ti / 1.4571 MAG 5000, IP67 / NEMA 4X/6, Polyamid enclosure, With display, 115-230V AC 50/60 Hz No bus communication Metric Polyamid terminal box or 6000 I compact.
SITRANS FC Low Flow Program MASS2100 and FC300 flow sensors with digital transmitters FCT010/FCT030 SITRANS FC sensor MASS2100 or FC300 with SITRANS FC transmitter FCT030 MASS2100 Sensor Di 15 with DN25 (1 inch) connector size. Hygenic clamp ISO2852 AISI 316L / EN 1.4435 Max. media temperature 180 °C Standard calibration, Mass flow, 3 flow x 2 points Compact mounted transmitter. Painted aluminum transmitter enclosure. IP67 / NEMA 4X transmitter enclosure. (See Options for cable selection) Standard, no Ex approval Graphical local user interface, 240x160 pixels, Lid window in "Panzer glass Notes Product Configuration is incorrect. Please check the configuration.
MASS FCS200 GAS SENSOR . DN10 W2.4602/Hastelloy C22 PN350 1/2 Inch, NPT ASME B 1.20.1 Pipe thread PTB custody transfer approval Order trans. seperately Order cable seperately Standard Calibration 3 flow x 2 points
SITRANS FC 300 . DN4 W1.4435/316L (180C) PN100 G 1/4 Inch, ISO 228-1 Pipe thread Standard NONE No cable Standard Calibration 3 flow x 2 points
MASS FCS200 GAS SENSOR . DN10 W2.4602/Hastelloy C22 PN350 1/4 Inch, NPT ASME B 1.20.1 Pipe thread PTB custody transfer approval Order trans. seperately Order cable seperately Standard Calibration 3 flow x 2 points
SITRANS FC 300 . DN4 W1.4435/316L (180C) PN100 G 1/4 Inch, ISO 228-1 Pipe thread Standard NONE 10 m. Cable Standard Calibration 3 flow x 2 points
SITRANS FC 300 . DN4 W2.4602/Hastelloy C22 (115C) PN100 1/4 Inch, NPT ASME B 1.20.1 Pipe thread Standard NONE 5 m. Cable Standard Calibration 3 flow x 2 points
SITRANS FC 300 . DN4 W2.4602/Hastelloy C22 (180C) PN100 G 1/4 Inch, ISO 228-1 Pipe thread Standard NONE No cable Standard Calibration 3 flow x 2 points
SITRANS FC 300 . DN4 W2.4602/Hastelloy C22 (115C) PN410 1/4 Inch, NPT ASME B 1.20.1 Pipe thread Standard NONE 5 m. Cable Standard Calibration 3 flow x 2 points
SITRANS FC 300 . DN4 W1.4435/316L (180C) PN100 G 1/4 Inch, ISO 228-1 Pipe thread Standard NONE 5 m. Cable Standard Calibration 3 flow x 2 points
SITRANS FC 300 . DN4 W1.4435/316L (115C) PN100 G 1/4 Inch, ISO 228-1 Pipe thread Standard NONE 25 m. Cable Standard Calibration 3 flow x 2 points
SITRANS FC 300 . DN4 W1.4435/316L (180C) PN100 G 1/4 Inch, ISO 228-1 Pipe thread Standard NONE 25 m. Cable Standard Calibration 3 flow x 2 points
SITRANS FC Low Flow Program MASS2100 and FC300 flow sensors with digital transmitters FCT010/FCT030 SITRANS FC sensor MASS2100 or FC300 with SITRANS FC transmitter FCT030 MASS2100 Sensor Di 15 with DN15 (1/2 inch) connector size. Weld neck flange EN1092-1 B1, pressure PN40 Hastelloy C22/ UNS N06022/ EN 2.4602 Max. media temperature 180 °C Standard calibration, Mass flow, 3 flow x 2 points + Density calibration included Compact mounted transmitter. Painted aluminum transmitter enclosure. IP67 / NEMA 4X transmitter enclosure. (See Options for cable selection) Standard, no Ex approval Graphical local user interface, 240x160 pixels, Lid window in "Panzer glass Notes Product Configuration is incorrect. Please check the configuration.
SITRANS FC 300 . DN4 W1.4435/316L (115C) PN130 G 1/4 Inch, ISO 228-1 Pipe thread Standard NONE 10 m. Cable Standard Calibration 3 flow x 2 points