Filters
Best selling products
25836 products
circuit breaker 3VA6 UL frame 250 breaking capacity class L 150kA @ 480V 3-pole, line protection ETU830, LIG, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2...1 x In, tg=0.05-0.8s without connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=25A overload protection Ir=10A...25A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s clamp connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU330, LIG, In=160A overload protection Ir=63A...160A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) ground-fault protection Ig=0.2...1 x In= tg=0.1/0.3s clamp connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU860, LSIG, In=63A overload protection Ir=25A...63A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.25...1 x In, tg=0.05-0.8s clamp connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU550, LSI, In=25A overload protection Ir=10A...25A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) clamp connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 4-pole, line protection ETU860, LSIG, In=100A overload protection Ir=40A...100A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.2...1 x In= tg=0.05-0.8s clamp connection
SIRIUS soft starter 200-480 V 370 A, 24 V AC/DC spring-type terminals Thermistor input
XUSL type 4 - Slave2 - For hand protection - Hp = 460 mm, R=30mm
XUSL type 4 - Slave2 - For body protection - 510 mm
Safety Controller CPU spring term. combined with backplane expansion connector
integrated drive ILS with stepper motor - 24..48 V - EtherCAT - 3.5 A
brushless dc motor 24..48 V - Ethernet Powerlink interface - L = 174 mm - 92:1
UPS AC/AC to control cabinet with battery built-3000VA//2100W
AC servo motor BSH - 2.2 N.m - 3000 rpm - keyed shaft - without brake - IP65
servo motor BMI 1-phase - keyed IP54 single turn - 32768 p/t - brake
BRAND NEW CONDITION, GUARANTEED.
servo motor BMH - 6.2 Nm - 6000 rpm - keyed shaft - without brake - IP65/IP67
servo motor BMH - 2.5 Nm - 8000 rpm - keyed shaft - without brake - IP54
servo motor BMH - 1.2 Nm - 8000 rpm - untapped shaft - with brake - IP65/IP67
Crimping tool for crimping of crimp contacts for Front connector K
SINAMICS G110D AC Drive, without Repair circuit with integrated Class A filter with integrated braking chopper with AS-Interface bus interface 380-500 V 3AC +10/-10% 47-63 Hz Power high overload: 1.5kW at 200% 3s, 150% 60S, 100% 300S; Ambient temperature -10 to +40 °C 210x 450x 145 (HxWxD), FSA Degree of protection IP65 without operator panel
SIMATIC PCS 7 CPU 410 Redundancy automation system pre-mounted and checked; with 2x CPU 410-5H Process Automation Incl. AS RT PO 100; with 2 x system expansion cards PO 500; With 2x 2 10 m sync mod. XTR and 2x 1 m FOC; Without CP443-1IE; With 1x UR2-H XTR (2 x 9 slots) Aluminum rack; With 2x 24 V DC 10 A Power supply; Bundle Release F: Without IL Runtime License Without CP443-5EXT (PROFIBUS);
Simatic WinCC RT Professional, Powerpack 102400 Powertags -> 153600 P-Tags V14 / Asia V14 (No Change Of Version) Runtime-SW in Tia Portal, Single License, Without SW And Docu., License Key on USB Stick, Class A
circuit breaker VL800L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=800A, rated current IR=320...800A, overload protection, II=1.25 to 8 xIN, short-circuit protection N protected without auxiliary release ETU communication-capable without auxiliary/alarm switch Notes Sucessor:Further information about local contact: www.siemens.com/lowvoltage/contact