Filters
Best selling products
25228 products
circuit breaker 3VA6 UL frame 150 breaking capacity class L 150kA @ 480V 3-pole, line protection ETU550, LSI, In=150A overload protection Ir=60A...150A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% without connection
circuit breaker 3VA6 UL frame 150 breaking capacity class L 150kA @ 480V 4-pole, line protection ETU550, LSI, In=150A overload protection Ir=60A...150A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) without connection
circuit breaker 3VA6 UL frame 150 breaking capacity class L 150kA @ 480V 4-pole, line protection ETU860, LSIG, In=150A overload protection Ir=60A...150A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection adjustable (OFF, up to 100%) ground-fault protection Ig=0.2...1 x In= tg=0.05-0.8s without connection
circuit breaker 3VA6 UL frame 150 breaking capacity class L 150kA @ 480V 3-pole, line protection ETU830, LIG, In=150A overload protection Ir=60A...150A short-circuit protection Ii=1.5...10 x In ground-fault protection Ig=0.2...1 x In, tg=0.05-0.8s without connection
circuit breaker 3VA6 UL frame 150 breaking capacity class L 150kA @ 480V 4-pole, line protection ETU556, LSI, In=100A overload protection Ir=40A...100A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) ground-fault alarm message via EFB300 or COM without connection
circuit breaker 3VA6 UL frame 150 breaking capacity class L 150kA @ 480V 4-pole, line protection ETU560, LSIG, In=100A overload protection Ir=40A...100A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) ground-fault protection Ig=0.2...1 x In= tg=0.05-0.8s without connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU560, LSIG, In=63A overload protection Ir=25A...63A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.25...1 x In= tg=0.05-0.8s nut keeper kit
circuit breaker 3VA2 IEC frame 100 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU850, LSI, In=100A overload protection Ir=40A...100A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 100%) clamp connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU550, LSI, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) clamp connection
XUSL type 2 IP69K Hand protection with Heating - Std range - Hp = 910mm, R=30mm
Speed monitoring 1 HTL encoder expansion module with spring term
integrated drive ILS with stepper motor - 24..48 V - Ethernet Powerlink - 3.5 A
integrated drive ILS with stepper motor - 24..48 V - EtherCAT - 5 A
integrated drive ILS with stepper motor - 24..48 V - EtherCAT - 3.5 A
brushless dc motor 24..48 V - Modbus TCP interface - L = 140 mm - w/o gearbox
servo motor BMH - 84 Nm - 3800 rpm - keyed shaft - without brake - IP54
servo motor BMH - 84 Nm - 3800 rpm - keyed shaft - with brake - IP54
servo motor BMH - 8.4 Nm - 6000 rpm - untapped shaft - with brake - IP65/IP67
servo motor BMH - 6.2 Nm - 6000 rpm - untapped shaft - without brake - IP54
servo motor BMH - 3.3 Nm - 6000 rpm - untapped shaft - without brake - IP65/IP67
SIMATIC PCS 7 Redundancy AS pre-mounted and checked; Without memory card With 2 x CPU 414 H incl. AS RT PO 100)) With 2 x 2 10 m sync module and 2 x 1 m FOC With 2 x CP443-1 IE/PN With 1 x UR2-H (2 x 9 slots) Aluminum rack With 2 x 24 V DC 10 A Power supply Bundle Release F: Without IL Runtime License Without additional I/O connection
Simatic WinCC RT Prof. V14 SP1, Upgrade WinCC V7.0..V7.3 RT 262144 Powertags -> WinCC RT Professional 262144 Powertags V14 SP1, Runtime-SW in the Tia Portal, Single License, SW And Documentation on DVD, License Key on USB Stick, Class A, 6 Languages(Ge,En,It,Fr,Sp,Ch), Executable Under Windows 7 Prof/Ent/Ult SP1 (32/64 bit)/ 10 Prof/Ent (64 bit)/ 8.1 Pro/Ent (64 bit)/ Server2008 R2 +SP1 (64 bit)/ Server 2012 R2 / 2016 (64 bit)/
circuit breaker VL1250L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=1250A, rated current IR=500...1250A, overload protection, II=1.25 to 10xIN, short-circuit protection without auxiliary release without auxiliary/alarm switch Notes Sucessor:Further information about local contact: www.siemens.com/lowvoltage/contact
circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=1250A, rated current IR=500...1250A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection without auxiliary release without auxiliary/alarm switch Notes Sucessor:Further information about local contact: www.siemens.com/lowvoltage/contact
Filters