2CSR273001R1324 ABB - DS203 M AC-C32/0.03

Technical

Type of Residual Current:
Type AC
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 15 kA
Power Supply Connection:
Arbitrary
Electrical Endurance:
10000 cycle
Number of Protected Poles:
3
Number of Poles:
3P
Number of Earth Leakage Circuit Breakers (ELCBs):
1
Operating Characteristic:
Instantaneous
Release Type:
C
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²

Electrical

Short-Circuit Current Rating (SCCR):
30 mA
Tripping Characteristic:
C
Rated Voltage (Ur):
400 V AC
Rated Operational Voltage:
400 V AC
Rated Current (In):
32 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
(400 V AC) 10 kA
Maximum Breaking Capacity:
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
15.7 W

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date:
20211115
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
SCIP:
33e3f2dd-9733-418c-a8a6-443f1d04461c Italy
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27:
25g 2 shocks 13 ms
Environmental Information:

Dimensions

Product Net Width:
87.5 mm
Product Net Height:
85 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
625 g

Engineering

EPLAN Data:

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.655 kg

Certificates and Declarations

Declaration of Conformity - CE:

Popular Downloads

External Classifications and Standards

ETIM 9:
EC002281 - Distributor assembly with combination RCCB/MCB
ETIM 10:
EC002281 - Distributor assembly with combination RCCB/MCB
eClass:
V11.0 : 27400618
Object Classification Code:
F
Standards:
IEC/EN 60947-2
IEC/EN 61009-1
IEC/EN 60947-2
IEC/EN 61009-1
2CSR273001R1325 ABB - DS203 M AC-B32/0.03

Technical

Type of Residual Current:
Type AC
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 15 kA
Power Supply Connection:
Arbitrary
Electrical Endurance:
10000 cycle
Number of Protected Poles:
3
Number of Poles:
3P
Number of Earth Leakage Circuit Breakers (ELCBs):
1
Operating Characteristic:
Instantaneous
Release Type:
B
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²

Electrical

Short-Circuit Current Rating (SCCR):
30 mA
Tripping Characteristic:
B
Rated Voltage (Ur):
400 V AC
Rated Operational Voltage:
400 V AC
Rated Current (In):
32 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
(400 V AC) 10 kA
Maximum Breaking Capacity:
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
15.7 W

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date:
20211115
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
SCIP:
33e3f2dd-9733-418c-a8a6-443f1d04461c Italy
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27:
25g 2 shocks 13 ms
Environmental Information:

Dimensions

Product Net Width:
87.5 mm
Product Net Height:
85 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
625 g

Engineering

EPLAN Data:

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.655 kg

Certificates and Declarations

Declaration of Conformity - CE:

Popular Downloads

External Classifications and Standards

ETIM 9:
EC002281 - Distributor assembly with combination RCCB/MCB
ETIM 10:
EC002281 - Distributor assembly with combination RCCB/MCB
eClass:
V11.0 : 27400618
Object Classification Code:
F
Standards:
IEC/EN 60947-2
IEC/EN 61009-1
IEC/EN 60947-2
IEC/EN 61009-1
2CSR273001R1404 ABB - DS203 M AC-C40/0.03

Technical

Type of Residual Current:
Type AC
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 15 kA
Power Supply Connection:
Arbitrary
Electrical Endurance:
10000 cycle
Number of Protected Poles:
3
Number of Poles:
3P
Number of Earth Leakage Circuit Breakers (ELCBs):
1
Operating Characteristic:
Instantaneous
Release Type:
C
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²

Electrical

Short-Circuit Current Rating (SCCR):
30 mA
Tripping Characteristic:
C
Rated Voltage (Ur):
400 V AC
Rated Operational Voltage:
400 V AC
Rated Current (In):
40 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
(400 V AC) 10 kA
Maximum Breaking Capacity:
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
21.6 W

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date:
20211115
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
SCIP:
33e3f2dd-9733-418c-a8a6-443f1d04461c Italy
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27:
25g 2 shocks 13 ms
Environmental Information:

Dimensions

Product Net Width:
87.5 mm
Product Net Height:
85 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
625 g

Engineering

EPLAN Data:

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.655 kg

Certificates and Declarations

Declaration of Conformity - CE:

Popular Downloads

External Classifications and Standards

ETIM 9:
EC002281 - Distributor assembly with combination RCCB/MCB
ETIM 10:
EC002281 - Distributor assembly with combination RCCB/MCB
eClass:
V11.0 : 27400618
Object Classification Code:
F
Standards:
IEC/EN 60947-2
IEC/EN 61009-1
IEC/EN 60947-2
IEC/EN 61009-1
2CSR273001R1634 ABB - DS203 M AC-C63/0.03

Technical

Type of Residual Current:
Type AC
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 15 kA
Power Supply Connection:
Arbitrary
Electrical Endurance:
10000 cycle
Number of Protected Poles:
3
Number of Poles:
3P
Number of Earth Leakage Circuit Breakers (ELCBs):
1
Operating Characteristic:
Instantaneous
Release Type:
C
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 25 ... 25 mm²
Flexible 25 ... 25 mm²
Busbar 10 mm²
Rigid 25 ... 25 mm²
Flexible 25 ... 25 mm²

Electrical

Short-Circuit Current Rating (SCCR):
30 mA
Tripping Characteristic:
C
Rated Voltage (Ur):
400 V AC
Rated Operational Voltage:
400 V AC
Rated Current (In):
63 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
(400 V AC) 10 kA
Maximum Breaking Capacity:
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
28.2 W

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date:
20211115
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
SCIP:
33e3f2dd-9733-418c-a8a6-443f1d04461c Italy
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27:
25g 2 shocks 13 ms
Environmental Information:

Dimensions

Product Net Width:
105 mm
Product Net Height:
85 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
775 g

Engineering

EPLAN Data:

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.71 kg

Certificates and Declarations

Declaration of Conformity - CE:

Popular Downloads

External Classifications and Standards

ETIM 9:
EC002281 - Distributor assembly with combination RCCB/MCB
ETIM 10:
EC002281 - Distributor assembly with combination RCCB/MCB
eClass:
V11.0 : 27400618
Object Classification Code:
F
Standards:
IEC/EN 60947-2
IEC/EN 61009-1
IEC/EN 60947-2
IEC/EN 61009-1
2CSR273101R1324 ABB - DS203 M A-C32/0.03

Technical

Type of Residual Current:
Type A
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 15 kA
Power Supply Connection:
Arbitrary
Electrical Endurance:
10000 cycle
Number of Protected Poles:
3
Number of Poles:
3P
Number of Earth Leakage Circuit Breakers (ELCBs):
1
Operating Characteristic:
Instantaneous
Release Type:
C
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²

Electrical

Short-Circuit Current Rating (SCCR):
30 mA
Tripping Characteristic:
C
Rated Voltage (Ur):
400 V AC
Rated Operational Voltage:
400 V AC
Rated Current (In):
32 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
(400 V AC) 10 kA
Maximum Breaking Capacity:
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
15.7 W

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date:
20211115
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
SCIP:
33e3f2dd-9733-418c-a8a6-443f1d04461c Italy
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27:
25g 2 shocks 13 ms
Environmental Information:

Dimensions

Product Net Width:
87.5 mm
Product Net Height:
85 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
625 g

Engineering

EPLAN Data:

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.655 kg

Certificates and Declarations

Declaration of Conformity - CE:

Popular Downloads

External Classifications and Standards

ETIM 9:
EC002281 - Distributor assembly with combination RCCB/MCB
ETIM 10:
EC002281 - Distributor assembly with combination RCCB/MCB
eClass:
V11.0 : 27400618
Object Classification Code:
F
Standards:
IEC/EN 60947-2
IEC/EN 61009-1
IEC/EN 60947-2
IEC/EN 61009-1
2CSR273101R1325 ABB - DS203 M A-B32/0.03

Technical

Type of Residual Current:
Type A
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 15 kA
Power Supply Connection:
Arbitrary
Electrical Endurance:
10000 cycle
Number of Protected Poles:
3
Number of Poles:
3P
Number of Earth Leakage Circuit Breakers (ELCBs):
1
Operating Characteristic:
Instantaneous
Release Type:
B
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²

Electrical

Short-Circuit Current Rating (SCCR):
30 mA
Tripping Characteristic:
B
Rated Voltage (Ur):
400 V AC
Rated Operational Voltage:
400 V AC
Rated Current (In):
32 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
(400 V AC) 10 kA
Maximum Breaking Capacity:
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
15.7 W

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date:
20211115
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
SCIP:
33e3f2dd-9733-418c-a8a6-443f1d04461c Italy
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27:
25g 2 shocks 13 ms
Environmental Information:

Dimensions

Product Net Width:
87.5 mm
Product Net Height:
85 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
625 g

Engineering

EPLAN Data:

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.655 kg

Certificates and Declarations

Declaration of Conformity - CE:

Popular Downloads

External Classifications and Standards

ETIM 9:
EC002281 - Distributor assembly with combination RCCB/MCB
ETIM 10:
EC002281 - Distributor assembly with combination RCCB/MCB
eClass:
V11.0 : 27400618
Object Classification Code:
F
Standards:
IEC/EN 60947-2
IEC/EN 61009-1
IEC/EN 60947-2
IEC/EN 61009-1
2CSR274001R1255 ABB - DS204 M AC-B25/0.03

Technical

Type of Residual Current:
Type AC
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 15 kA
Power Supply Connection:
Arbitrary
Electrical Endurance:
10000 cycle
Number of Protected Poles:
4
Number of Poles:
4P
Number of Earth Leakage Circuit Breakers (ELCBs):
1
Operating Characteristic:
Instantaneous
Position of Neutral Terminals:
Right
Left
Right
Left
Release Type:
B
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²

Electrical

Short-Circuit Current Rating (SCCR):
30 mA
Tripping Characteristic:
B
Rated Voltage (Ur):
400 V AC
Rated Operational Voltage:
400 V AC
Rated Current (In):
25 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
(400 V AC) 10 kA
Maximum Breaking Capacity:
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
12.4 W

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date:
20211115
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
SCIP:
33e3f2dd-9733-418c-a8a6-443f1d04461c Italy
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27:
25g 2 shocks 13 ms
Environmental Information:

Dimensions

Product Net Width:
122.5 mm
Product Net Height:
85 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
775 g

Engineering

EPLAN Data:

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.83 kg

Certificates and Declarations

Declaration of Conformity - CE:

Popular Downloads

External Classifications and Standards

ETIM 9:
EC002281 - Distributor assembly with combination RCCB/MCB
ETIM 10:
EC002281 - Distributor assembly with combination RCCB/MCB
eClass:
V11.0 : 27400618
Object Classification Code:
F
Standards:
IEC/EN 60947-2
IEC/EN 61009-1
IEC/EN 60947-2
IEC/EN 61009-1
2CSR274001R1325 ABB - DS204 M AC-B32/0.03

Technical

Type of Residual Current:
Type AC
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 15 kA
Power Supply Connection:
Arbitrary
Electrical Endurance:
10000 cycle
Number of Protected Poles:
4
Number of Poles:
4P
Number of Earth Leakage Circuit Breakers (ELCBs):
1
Operating Characteristic:
Instantaneous
Position of Neutral Terminals:
Right
Left
Right
Left
Release Type:
B
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²

Electrical

Short-Circuit Current Rating (SCCR):
30 mA
Tripping Characteristic:
B
Rated Voltage (Ur):
400 V AC
Rated Operational Voltage:
400 V AC
Rated Current (In):
32 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
(400 V AC) 10 kA
Maximum Breaking Capacity:
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
15.7 W

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date:
20211115
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
SCIP:
33e3f2dd-9733-418c-a8a6-443f1d04461c Italy
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27:
25g 2 shocks 13 ms
Environmental Information:

Dimensions

Product Net Width:
122.5 mm
Product Net Height:
85 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
775 g

Engineering

EPLAN Data:

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.83 kg

Certificates and Declarations

Declaration of Conformity - CE:

Popular Downloads

External Classifications and Standards

ETIM 9:
EC002281 - Distributor assembly with combination RCCB/MCB
ETIM 10:
EC002281 - Distributor assembly with combination RCCB/MCB
eClass:
V11.0 : 27400618
Object Classification Code:
F
Standards:
IEC/EN 60947-2
IEC/EN 61009-1
IEC/EN 60947-2
IEC/EN 61009-1
2CSR274001R1635 ABB - DS204 M AC-B63/0.03

Technical

Type of Residual Current:
Type AC
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 15 kA
Power Supply Connection:
Arbitrary
Electrical Endurance:
10000 cycle
Number of Protected Poles:
4
Number of Poles:
4P
Number of Earth Leakage Circuit Breakers (ELCBs):
1
Operating Characteristic:
Instantaneous
Position of Neutral Terminals:
Right
Left
Right
Left
Release Type:
B
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 25 ... 25 mm²
Flexible 25 ... 25 mm²
Busbar 10 mm²
Rigid 25 ... 25 mm²
Flexible 25 ... 25 mm²

Electrical

Short-Circuit Current Rating (SCCR):
30 mA
Tripping Characteristic:
B
Rated Voltage (Ur):
400 V AC
Rated Operational Voltage:
400 V AC
Rated Current (In):
63 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
(400 V AC) 10 kA
Maximum Breaking Capacity:
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
28.2 W

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date:
20211115
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27:
25g 2 shocks 13 ms
Environmental Information:

Dimensions

Product Net Width:
140 mm
Product Net Height:
85 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
925 g

Engineering

EPLAN Data:

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.885 kg

Certificates and Declarations

Declaration of Conformity - CE:

Popular Downloads

External Classifications and Standards

ETIM 9:
EC002281 - Distributor assembly with combination RCCB/MCB
ETIM 10:
EC002281 - Distributor assembly with combination RCCB/MCB
eClass:
V11.0 : 27400618
Object Classification Code:
F
Standards:
IEC/EN 60947-2
IEC/EN 61009-1
IEC/EN 60947-2
IEC/EN 61009-1
2CSR274101R1254 ABB - DS204 M A-C25/0.03

Technical

Type of Residual Current:
Type A
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 15 kA
Power Supply Connection:
Arbitrary
Electrical Endurance:
10000 cycle
Number of Protected Poles:
4
Number of Poles:
4P
Number of Earth Leakage Circuit Breakers (ELCBs):
1
Operating Characteristic:
Instantaneous
Position of Neutral Terminals:
Right
Left
Right
Left
Release Type:
C
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²

Electrical

Short-Circuit Current Rating (SCCR):
30 mA
Tripping Characteristic:
C
Rated Voltage (Ur):
400 V AC
Rated Operational Voltage:
400 V AC
Rated Current (In):
25 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
(400 V AC) 10 kA
Maximum Breaking Capacity:
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
12.4 W

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date:
20211115
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
SCIP:
33e3f2dd-9733-418c-a8a6-443f1d04461c Italy
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27:
25g 2 shocks 13 ms
Environmental Information:

Dimensions

Product Net Width:
122.5 mm
Product Net Height:
85 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
775 g

Engineering

EPLAN Data:

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.83 kg
E-Number (Norway):
1653594

Certificates and Declarations

Declaration of Conformity - CE:

Popular Downloads

External Classifications and Standards

ETIM 9:
EC002281 - Distributor assembly with combination RCCB/MCB
ETIM 10:
EC002281 - Distributor assembly with combination RCCB/MCB
eClass:
V11.0 : 27400618
Object Classification Code:
F
Standards:
IEC/EN 60947-2
IEC/EN 61009-1
IEC/EN 60947-2
IEC/EN 61009-1
2CSR274101R1404 ABB - DS204 M A-C40/0.03

Technical

Type of Residual Current:
Type A
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 15 kA
Power Supply Connection:
Arbitrary
Electrical Endurance:
10000 cycle
Number of Protected Poles:
4
Number of Poles:
4P
Number of Earth Leakage Circuit Breakers (ELCBs):
1
Operating Characteristic:
Instantaneous
Position of Neutral Terminals:
Right
Left
Right
Left
Release Type:
C
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²
Busbar 10 mm²
Rigid 16 ... 25 mm²
Flexible 16 ... 25 mm²

Electrical

Short-Circuit Current Rating (SCCR):
30 mA
Tripping Characteristic:
C
Rated Voltage (Ur):
400 V AC
Rated Operational Voltage:
400 V AC
Rated Current (In):
40 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
(400 V AC) 10 kA
Maximum Breaking Capacity:
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
21.6 W

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date:
20211115
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
SCIP:
33e3f2dd-9733-418c-a8a6-443f1d04461c Italy
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27:
25g 2 shocks 13 ms
Environmental Information:

Dimensions

Product Net Width:
122.5 mm
Product Net Height:
85 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
775 g

Engineering

EPLAN Data:

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.83 kg
E-Number (Norway):
1653596

Certificates and Declarations

Declaration of Conformity - CE:

Popular Downloads

External Classifications and Standards

ETIM 9:
EC002281 - Distributor assembly with combination RCCB/MCB
ETIM 10:
EC002281 - Distributor assembly with combination RCCB/MCB
eClass:
V11.0 : 27400618
Object Classification Code:
F
Standards:
IEC/EN 60947-2
IEC/EN 61009-1
IEC/EN 60947-2
IEC/EN 61009-1
2CSR275040R1064 ABB
ABB 2CSR275040R1064 ABB
Sale price0.00 kr
Sold Out

DS201 Series: M DS201 C6 AC30 Differential circuit breaker, 10kA, type AC, Curve C, 6A 30mA 1P + N

2CSR275040R1104 ABB
ABB 2CSR275040R1104 ABB
Sale price0.00 kr
Sold Out

DS201 Series: M DS201 C10 AC30 Differential circuit breaker, 10kA, AC type, Curve C, 10A 30mA 1P + N

2CSR275040R1164 ABB
ABB 2CSR275040R1164 ABB
Sale price0.00 kr
Sold Out

DS201 Series: M DS201 C16 AC30 Differential circuit breaker, 10kA, AC type, Curve C, 16A 30mA 1P + N

2CSR275040R1204 ABB
ABB 2CSR275040R1204 ABB
Sale price0.00 kr
Sold Out

DS201 Series: M DS201 C20 AC30 Differential circuit breaker, 10kA, AC type, Curve C, 20A 30mA 1P + N

2CSR275040R1254 ABB
ABB 2CSR275040R1254 ABB
Sale price0.00 kr
Sold Out

DS201 Series: M DS201 C25 AC30 Differential circuit breaker, 10kA, AC type, Curve C, 25A 30mA 1P + N

2CSR275040R1324 ABB
ABB 2CSR275040R1324 ABB
Sale price0.00 kr
Sold Out

DS201 Series: M DS201 C32 AC30 Differential circuit breaker, 10kA, AC type, Curve C, 32A 30mA 1P + N

2CSR275040R3104 ABB
ABB 2CSR275040R3104 ABB
Sale price0.00 kr
Sold Out

DS201 Series: M DS201 C10 AC300 Differential circuit breaker, 10kA, AC type, Curve C, 10A 300mA 1P + N

2CSR275040R3164 ABB
ABB 2CSR275040R3164 ABB
Sale price0.00 kr
Sold Out

DS201 Series: M DS201 C16 AC300 Differential circuit breaker, 10kA, AC type, Curve C, 16A 300mA 1P + N

2CSR275051R1064 ABB - DSE201 M C6 AC30 - N Blue

ABB EcoSolutions

ABB EcoSolutions:
Yes
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 83.2 %
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Sustainable Material Content in Packaging (wt. %):
Recycled Cardboard - 96.89 %
Extended Product Lifetime:
Product Durability
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Technical

Type of Residual Current:
Type AC
Maximum Operating Voltage:
264 V
Test Voltage (Ut):
195 … 264 V
Dielectric Test Voltage:
2 kV
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
15 kA
Rated Residual Breaking Capacity (IΔm):
10 kA
Rated Service Short-Circuit Breaking Capacity (Ics):
7.5 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
7.5 kA
Maximum Surge Current:
0.25 kA
Power Supply Connection:
Bottom
Contact Position Indication:
Red ON / Green OFF
Energy Limiting Class:
3
Electrical Endurance:
10000 cycle
Mechanical Endurance:
20000 cycle
Number of Protected Poles:
1
Number of Poles:
1P+N
Number of Modular Spacings per DIN Rail:
1
Fault Indication:
Blue Window
Operating Characteristic:
Instantaneous
Position of Neutral Terminals:
Right
Tightening Torque:
Top 1.2 N·m
Bottom 2.8 N·m
Top 1.2 N·m
Bottom 2.8 N·m
Accessory Type:
Auxiliary contact
Auxiliary/Signal contact
Shunt trip
Undervoltage release
Overvoltage release
Bottom fitting auxiliary contact
Auxiliary contact
Auxiliary/Signal contact
Shunt trip
Undervoltage release
Overvoltage release
Bottom fitting auxiliary contact
Actuator Type:
Toggle - Insulation group II, black, sealable in ON-OFF positions
Earthing Switch Type:
Undelayed
Housing Type:
Insulation group II, RAL 7035
Screw Terminal Type:
Failsafe Bi-directional Cylinder-lift Terminal
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 1…35 mm²
Flexible 1…16 mm²
Busbar 10 mm²
Rigid 1…35 mm²
Flexible 1…16 mm²
Rated Cross-Section:
1 - Solid-Core 1…35 mm²
4 - Multi-Wired 1 … 25 mm²
1 - Solid-Core 1…35 mm²
4 - Multi-Wired 1 … 25 mm²
Wire Stripping Length:
Top 11 mm
Bottom 12.5 mm
Top 11 mm
Bottom 12.5 mm
Terminal Type:
Screw Terminals

Electrical

Short-Circuit Current Rating (SCCR):
0.03 A
Tripping Characteristic:
C
Rated Operational Voltage:
acc. to IEC 60898-1 240 V
Rated Insulation Voltage (Ui):
acc. to IEC/EN 60664-1 500 V
Rated Impulse Withstand Voltage (Uimp):
4 kV
Input Voltage Type:
AC
Rated Current (In):
6 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
10 kA
Rated Conditional Short-Circuit Current (Inc):
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
1.8 W
Overvoltage Category:
III

Material Compliance

RoHS Information:
RoHS Status:
Following EU Directive 2011/65/EU
RoHS Date:
20160829
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 … 55 °C
Reference Ambient Air Temperature:
30 °C
Degree of Protection:
IP20
IP40
IP20
IP40
Pollution Degree:
2
Environmental Conditions:
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 5g or 0.35mm 5 … 150 Hz
Resistance to Shock acc. to IEC 60068-2-27:
30g / 2 shocks / 13 ms

Dimensions

Width in Number of Modular Spacings:
1
Product Net Width:
18 mm
Product Net Height:
115 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
200 g
Built-In Depth (t2):
68.9 mm

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.220 kg

Certificates and Declarations

Declaration of Conformity - CE:

Installation

Instructions and Manuals:
Mounting Type:
DIN-Rail
Mounting Position:
Any

Popular Downloads

Data Sheet, Technical Information:

External Classifications and Standards

ETIM 9:
EC000905 - Earth leakage circuit breaker
ETIM 10:
EC000905 - Earth leakage circuit breaker
eClass:
V11.0 : 27142207
Object Classification Code:
F
Standards:
IEC 61009-1
IEC 61009-2-2
AS/NZS 61009.1
BS EN 61009-1
IEC 61009-1
IEC 61009-2-2
AS/NZS 61009.1
BS EN 61009-1
2CSR275051R1065 ABB - DSE201 M B6 AC30 - N Blue

ABB EcoSolutions

ABB EcoSolutions:
Yes
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 83.2 %
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Sustainable Material Content in Packaging (wt. %):
Recycled Cardboard - 96.89 %
Extended Product Lifetime:
Product Durability
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Technical

Type of Residual Current:
Type AC
Maximum Operating Voltage:
264 V
Test Voltage (Ut):
195 … 264 V
Dielectric Test Voltage:
2 kV
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
15 kA
Rated Residual Breaking Capacity (IΔm):
10 kA
Rated Service Short-Circuit Breaking Capacity (Ics):
7.5 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
7.5 kA
Maximum Surge Current:
0.25 kA
Power Supply Connection:
Bottom
Contact Position Indication:
Red ON / Green OFF
Energy Limiting Class:
3
Electrical Endurance:
10000 cycle
Mechanical Endurance:
20000 cycle
Number of Protected Poles:
1
Number of Poles:
1P+N
Number of Modular Spacings per DIN Rail:
1
Fault Indication:
Blue Window
Operating Characteristic:
Instantaneous
Position of Neutral Terminals:
Right
Tightening Torque:
Top 1.2 N·m
Bottom 2.8 N·m
Top 1.2 N·m
Bottom 2.8 N·m
Accessory Type:
Auxiliary contact
Auxiliary/Signal contact
Shunt trip
Undervoltage release
Overvoltage release
Bottom fitting auxiliary contact
Auxiliary contact
Auxiliary/Signal contact
Shunt trip
Undervoltage release
Overvoltage release
Bottom fitting auxiliary contact
Actuator Type:
Toggle - Insulation group II, black, sealable in ON-OFF positions
Earthing Switch Type:
Undelayed
Housing Type:
Insulation group II, RAL 7035
Screw Terminal Type:
Failsafe Bi-directional Cylinder-lift Terminal
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 1…35 mm²
Flexible 1…16 mm²
Busbar 10 mm²
Rigid 1…35 mm²
Flexible 1…16 mm²
Rated Cross-Section:
1 - Solid-Core 1…35 mm²
4 - Multi-Wired 1 … 25 mm²
1 - Solid-Core 1…35 mm²
4 - Multi-Wired 1 … 25 mm²
Wire Stripping Length:
Top 11 mm
Bottom 12.5 mm
Top 11 mm
Bottom 12.5 mm
Terminal Type:
Screw Terminals

Electrical

Short-Circuit Current Rating (SCCR):
0.03 A
Tripping Characteristic:
B
Rated Operational Voltage:
acc. to IEC 60898-1 240 V
Rated Insulation Voltage (Ui):
acc. to IEC/EN 60664-1 500 V
Rated Impulse Withstand Voltage (Uimp):
4 kV
Input Voltage Type:
AC
Rated Current (In):
6 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
10 kA
Rated Conditional Short-Circuit Current (Inc):
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
1.8 W
Overvoltage Category:
III

Material Compliance

RoHS Information:
RoHS Status:
Following EU Directive 2011/65/EU
RoHS Date:
20160829
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 … 55 °C
Reference Ambient Air Temperature:
30 °C
Degree of Protection:
IP20
IP40
IP20
IP40
Pollution Degree:
2
Environmental Conditions:
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 5g or 0.35mm 5 … 150 Hz
Resistance to Shock acc. to IEC 60068-2-27:
30g / 2 shocks / 13 ms

Dimensions

Width in Number of Modular Spacings:
1
Product Net Width:
18 mm
Product Net Height:
115 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
200 g
Built-In Depth (t2):
68.9 mm

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.220 kg

Certificates and Declarations

Declaration of Conformity - CE:

Installation

Instructions and Manuals:
Mounting Type:
DIN-Rail
Mounting Position:
Any

Popular Downloads

Data Sheet, Technical Information:

External Classifications and Standards

ETIM 9:
EC000905 - Earth leakage circuit breaker
ETIM 10:
EC000905 - Earth leakage circuit breaker
eClass:
V11.0 : 27142207
Object Classification Code:
F
Standards:
IEC 61009-1
IEC 61009-2-2
AS/NZS 61009.1
BS EN 61009-1
IEC 61009-1
IEC 61009-2-2
AS/NZS 61009.1
BS EN 61009-1
2CSR275051R1104 ABB - DSE201 M C10 AC30 - N Blue

ABB EcoSolutions

ABB EcoSolutions:
Yes
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 83.2 %
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Sustainable Material Content in Packaging (wt. %):
Recycled Cardboard - 96.89 %
Extended Product Lifetime:
Product Durability
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Technical

Type of Residual Current:
Type AC
Maximum Operating Voltage:
264 V
Test Voltage (Ut):
195 … 264 V
Dielectric Test Voltage:
2 kV
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
15 kA
Rated Residual Breaking Capacity (IΔm):
10 kA
Rated Service Short-Circuit Breaking Capacity (Ics):
7.5 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
7.5 kA
Maximum Surge Current:
0.25 kA
Power Supply Connection:
Bottom
Contact Position Indication:
Red ON / Green OFF
Energy Limiting Class:
3
Electrical Endurance:
10000 cycle
Mechanical Endurance:
20000 cycle
Number of Protected Poles:
1
Number of Poles:
1P+N
Number of Modular Spacings per DIN Rail:
1
Fault Indication:
Blue Window
Operating Characteristic:
Instantaneous
Position of Neutral Terminals:
Right
Tightening Torque:
Top 1.2 N·m
Bottom 2.8 N·m
Top 1.2 N·m
Bottom 2.8 N·m
Accessory Type:
Auxiliary contact
Auxiliary/Signal contact
Shunt trip
Undervoltage release
Overvoltage release
Bottom fitting auxiliary contact
Auxiliary contact
Auxiliary/Signal contact
Shunt trip
Undervoltage release
Overvoltage release
Bottom fitting auxiliary contact
Actuator Type:
Toggle - Insulation group II, black, sealable in ON-OFF positions
Earthing Switch Type:
Undelayed
Housing Type:
Insulation group II, RAL 7035
Screw Terminal Type:
Failsafe Bi-directional Cylinder-lift Terminal
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 1…35 mm²
Flexible 1…16 mm²
Busbar 10 mm²
Rigid 1…35 mm²
Flexible 1…16 mm²
Rated Cross-Section:
1 - Solid-Core 1…35 mm²
4 - Multi-Wired 1 … 25 mm²
1 - Solid-Core 1…35 mm²
4 - Multi-Wired 1 … 25 mm²
Wire Stripping Length:
Top 11 mm
Bottom 12.5 mm
Top 11 mm
Bottom 12.5 mm
Terminal Type:
Screw Terminals

Electrical

Short-Circuit Current Rating (SCCR):
0.03 A
Tripping Characteristic:
C
Rated Operational Voltage:
acc. to IEC 60898-1 240 V
Rated Insulation Voltage (Ui):
acc. to IEC/EN 60664-1 500 V
Rated Impulse Withstand Voltage (Uimp):
4 kV
Input Voltage Type:
AC
Rated Current (In):
10 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
10 kA
Rated Conditional Short-Circuit Current (Inc):
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
1.8 W
Overvoltage Category:
III

Material Compliance

RoHS Information:
RoHS Status:
Following EU Directive 2011/65/EU
RoHS Date:
20160829
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 … 55 °C
Reference Ambient Air Temperature:
30 °C
Degree of Protection:
IP20
IP40
IP20
IP40
Pollution Degree:
2
Environmental Conditions:
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 5g or 0.35mm 5 … 150 Hz
Resistance to Shock acc. to IEC 60068-2-27:
30g / 2 shocks / 13 ms

Dimensions

Width in Number of Modular Spacings:
1
Product Net Width:
18 mm
Product Net Height:
115 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
200 g
Built-In Depth (t2):
68.9 mm

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.220 kg

Certificates and Declarations

Declaration of Conformity - CE:

Installation

Instructions and Manuals:
Mounting Type:
DIN-Rail
Mounting Position:
Any

Popular Downloads

Data Sheet, Technical Information:

External Classifications and Standards

ETIM 9:
EC000905 - Earth leakage circuit breaker
ETIM 10:
EC000905 - Earth leakage circuit breaker
eClass:
V11.0 : 27142207
Object Classification Code:
F
Standards:
IEC 61009-1
IEC 61009-2-2
AS/NZS 61009.1
BS EN 61009-1
IEC 61009-1
IEC 61009-2-2
AS/NZS 61009.1
BS EN 61009-1
2CSR275051R1164 ABB - DSE201 M C16 AC30 - N Blue

ABB EcoSolutions

ABB EcoSolutions:
Yes
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 83.2 %
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Sustainable Material Content in Packaging (wt. %):
Recycled Cardboard - 96.89 %
Extended Product Lifetime:
Product Durability
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Technical

Type of Residual Current:
Type AC
Maximum Operating Voltage:
264 V
Test Voltage (Ut):
195 … 264 V
Dielectric Test Voltage:
2 kV
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
15 kA
Rated Residual Breaking Capacity (IΔm):
10 kA
Rated Service Short-Circuit Breaking Capacity (Ics):
7.5 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
7.5 kA
Maximum Surge Current:
0.25 kA
Power Supply Connection:
Bottom
Contact Position Indication:
Red ON / Green OFF
Energy Limiting Class:
3
Electrical Endurance:
10000 cycle
Mechanical Endurance:
20000 cycle
Number of Protected Poles:
1
Number of Poles:
1P+N
Number of Modular Spacings per DIN Rail:
1
Fault Indication:
Blue Window
Operating Characteristic:
Instantaneous
Position of Neutral Terminals:
Right
Tightening Torque:
Top 1.2 N·m
Bottom 2.8 N·m
Top 1.2 N·m
Bottom 2.8 N·m
Accessory Type:
Auxiliary contact
Auxiliary/Signal contact
Shunt trip
Undervoltage release
Overvoltage release
Bottom fitting auxiliary contact
Auxiliary contact
Auxiliary/Signal contact
Shunt trip
Undervoltage release
Overvoltage release
Bottom fitting auxiliary contact
Actuator Type:
Toggle - Insulation group II, black, sealable in ON-OFF positions
Earthing Switch Type:
Undelayed
Housing Type:
Insulation group II, RAL 7035
Screw Terminal Type:
Failsafe Bi-directional Cylinder-lift Terminal
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 1…35 mm²
Flexible 1…16 mm²
Busbar 10 mm²
Rigid 1…35 mm²
Flexible 1…16 mm²
Rated Cross-Section:
1 - Solid-Core 1…35 mm²
4 - Multi-Wired 1 … 25 mm²
1 - Solid-Core 1…35 mm²
4 - Multi-Wired 1 … 25 mm²
Wire Stripping Length:
Top 11 mm
Bottom 12.5 mm
Top 11 mm
Bottom 12.5 mm
Terminal Type:
Screw Terminals

Electrical

Short-Circuit Current Rating (SCCR):
0.03 A
Tripping Characteristic:
C
Rated Operational Voltage:
acc. to IEC 60898-1 240 V
Rated Insulation Voltage (Ui):
acc. to IEC/EN 60664-1 500 V
Rated Impulse Withstand Voltage (Uimp):
4 kV
Input Voltage Type:
AC
Rated Current (In):
16 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
10 kA
Rated Conditional Short-Circuit Current (Inc):
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
2.4 W
Overvoltage Category:
III

Material Compliance

RoHS Information:
RoHS Status:
Following EU Directive 2011/65/EU
RoHS Date:
20160829
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 … 55 °C
Reference Ambient Air Temperature:
30 °C
Degree of Protection:
IP20
IP40
IP20
IP40
Pollution Degree:
2
Environmental Conditions:
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 5g or 0.35mm 5 … 150 Hz
Resistance to Shock acc. to IEC 60068-2-27:
30g / 2 shocks / 13 ms

Dimensions

Width in Number of Modular Spacings:
1
Product Net Width:
18 mm
Product Net Height:
115 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
200 g
Built-In Depth (t2):
68.9 mm

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.220 kg

Certificates and Declarations

Declaration of Conformity - CE:

Installation

Instructions and Manuals:
Mounting Type:
DIN-Rail
Mounting Position:
Any

Popular Downloads

Data Sheet, Technical Information:

External Classifications and Standards

ETIM 9:
EC000905 - Earth leakage circuit breaker
ETIM 10:
EC000905 - Earth leakage circuit breaker
eClass:
V11.0 : 27142207
Object Classification Code:
F
Standards:
IEC 61009-1
IEC 61009-2-2
AS/NZS 61009.1
BS EN 61009-1
IEC 61009-1
IEC 61009-2-2
AS/NZS 61009.1
BS EN 61009-1
2CSR275051R1165 ABB - DSE201 M B16 AC30 - N Blue

ABB EcoSolutions

ABB EcoSolutions:
Yes
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 83.2 %
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Sustainable Material Content in Packaging (wt. %):
Recycled Cardboard - 96.89 %
Extended Product Lifetime:
Product Durability
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Technical

Type of Residual Current:
Type AC
Maximum Operating Voltage:
264 V
Test Voltage (Ut):
195 … 264 V
Dielectric Test Voltage:
2 kV
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
15 kA
Rated Residual Breaking Capacity (IΔm):
10 kA
Rated Service Short-Circuit Breaking Capacity (Ics):
7.5 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
7.5 kA
Maximum Surge Current:
0.25 kA
Power Supply Connection:
Bottom
Contact Position Indication:
Red ON / Green OFF
Energy Limiting Class:
3
Electrical Endurance:
10000 cycle
Mechanical Endurance:
20000 cycle
Number of Protected Poles:
1
Number of Poles:
1P+N
Number of Modular Spacings per DIN Rail:
1
Fault Indication:
Blue Window
Operating Characteristic:
Instantaneous
Position of Neutral Terminals:
Right
Tightening Torque:
Top 1.2 N·m
Bottom 2.8 N·m
Top 1.2 N·m
Bottom 2.8 N·m
Accessory Type:
Auxiliary contact
Auxiliary/Signal contact
Shunt trip
Undervoltage release
Overvoltage release
Bottom fitting auxiliary contact
Auxiliary contact
Auxiliary/Signal contact
Shunt trip
Undervoltage release
Overvoltage release
Bottom fitting auxiliary contact
Actuator Type:
Toggle - Insulation group II, black, sealable in ON-OFF positions
Earthing Switch Type:
Undelayed
Housing Type:
Insulation group II, RAL 7035
Screw Terminal Type:
Failsafe Bi-directional Cylinder-lift Terminal
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 1…35 mm²
Flexible 1…16 mm²
Busbar 10 mm²
Rigid 1…35 mm²
Flexible 1…16 mm²
Rated Cross-Section:
1 - Solid-Core 1…35 mm²
4 - Multi-Wired 1 … 25 mm²
1 - Solid-Core 1…35 mm²
4 - Multi-Wired 1 … 25 mm²
Wire Stripping Length:
Top 11 mm
Bottom 12.5 mm
Top 11 mm
Bottom 12.5 mm
Terminal Type:
Screw Terminals

Electrical

Short-Circuit Current Rating (SCCR):
0.03 A
Tripping Characteristic:
B
Rated Operational Voltage:
acc. to IEC 60898-1 240 V
Rated Insulation Voltage (Ui):
acc. to IEC/EN 60664-1 500 V
Rated Impulse Withstand Voltage (Uimp):
4 kV
Input Voltage Type:
AC
Rated Current (In):
16 A
Rated Residual Current:
30 mA
Rated Short-Circuit Capacity:
10 kA
Rated Conditional Short-Circuit Current (Inc):
10 kA
Rated Frequency (f):
50 … 60 Hz
Power Loss:
2.4 W
Overvoltage Category:
III

Material Compliance

RoHS Information:
RoHS Status:
Following EU Directive 2011/65/EU
RoHS Date:
20160829
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 … 55 °C
Reference Ambient Air Temperature:
30 °C
Degree of Protection:
IP20
IP40
IP20
IP40
Pollution Degree:
2
Environmental Conditions:
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 5g or 0.35mm 5 … 150 Hz
Resistance to Shock acc. to IEC 60068-2-27:
30g / 2 shocks / 13 ms

Dimensions

Width in Number of Modular Spacings:
1
Product Net Width:
18 mm
Product Net Height:
115 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
200 g
Built-In Depth (t2):
68.9 mm

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.220 kg

Certificates and Declarations

Declaration of Conformity - CE:

Installation

Instructions and Manuals:
Mounting Type:
DIN-Rail
Mounting Position:
Any

Popular Downloads

Data Sheet, Technical Information:

External Classifications and Standards

ETIM 9:
EC000905 - Earth leakage circuit breaker
ETIM 10:
EC000905 - Earth leakage circuit breaker
eClass:
V11.0 : 27142207
Object Classification Code:
F
Standards:
IEC 61009-1
IEC 61009-2-2
AS/NZS 61009.1
BS EN 61009-1
IEC 61009-1
IEC 61009-2-2
AS/NZS 61009.1
BS EN 61009-1

Recently viewed