{"product_id":"rm35tf30","title":"RM35TF30 Schneider","description":"\u003cp\u003eHarmony Control Monitoring and Control Relays (RM17, RM22, RM35) monitor and detect abnormal operating conditions concerning phase ,current, voltage, frequency, speed, or temperature. The relays inform users of abnormal conditions and allow them to initiate the necessary corrective actions before serious and costly breakdown can occur. Harmony phase control relays detect all possible faults occurring in the phases. Harmony voltage and current control relays ensure your equipment is powered with proper values. Harmony frequency control relay monitors frequency variation from your power generation line. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Harmony pump control relay controls and protects your pump from dry running or overloading. Harmony speed control relay picks up the improper rhythm of your process. Harmony temperature control relay for lift application is a dedicated to elevator temperature monitoring (EN81). Harmony temperature control relays are dedicated to temperature regulation (heating, cooling or heating\/cooling of processes). These Harmony relays are available in 17.5 mm, 22.5 mm or 35 mm wide housings and are DIN rail mounted. Applications for these Harmony relays include hoisting, construction cranes, harbor cranes, packaging, construction elevators, passenger elevators, escalators, textile, water and waste water.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eHarmony Control Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eMultifunction control relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003e3-phase control relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay name\u003c\/td\u003e\n\u003ctd\u003eRM35TF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay monitored parameters\u003c\/td\u003e\n\u003ctd\u003eUndervoltage and overvoltage in window mode\u003cbr\u003ePhase sequence\u003cbr\u003ePhase failure detection\u003cbr\u003eAsymmetry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e220...480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003etime delay\u003c\/td\u003e\n\u003ctd\u003eAdjustable 0.1...10 s, +\/- 10 % of the full scale value Tt- time delay upon fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput contacts\u003c\/td\u003e\n\u003ctd\u003e2 C\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal output current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContacts type and composition\u003c\/td\u003e\n\u003ctd\u003e2 C\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e220...480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Specific Application\u003c\/td\u003e\n\u003ctd\u003eFor 3-phase supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Un] rated nominal voltage\u003c\/td\u003e\n\u003ctd\u003e, self-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage limits\u003c\/td\u003e\n\u003ctd\u003e194â¦528 V AC, 3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset time\u003c\/td\u003e\n\u003ctd\u003e1500 ms at 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum switching voltage\u003c\/td\u003e\n\u003ctd\u003e250 V AC\u003cbr\u003e250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching capacity in VA\u003c\/td\u003e\n\u003ctd\u003e1250 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e10 mA 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum switching current\u003c\/td\u003e\n\u003ctd\u003e5 A AC\u003cbr\u003e5 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e- 12 % + 10 % Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption in VA\u003c\/td\u003e\n\u003ctd\u003e0â¦22 VA 400 V AC 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage detection threshold\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 194 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit frequency\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz +\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement voltage limits\u003c\/td\u003e\n\u003ctd\u003e176â¦528 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHysteresis\u003c\/td\u003e\n\u003ctd\u003e2 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edelay at power up\u003c\/td\u003e\n\u003ctd\u003e650 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum measuring cycle\u003c\/td\u003e\n\u003ctd\u003e140 ms measurement cycle as true rms value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThreshold adjustment voltage\u003c\/td\u003e\n\u003ctd\u003e2...20 % of Un selected\u003cbr\u003e-12...-2 % in the range 220 V AC\u003cbr\u003e+2...+10 % in the range 480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage range\u003c\/td\u003e\n\u003ctd\u003e220...480 V phase to phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment of asymmetry threshold\u003c\/td\u003e\n\u003ctd\u003e5...15 % of Un selected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeat accuracy\u003c\/td\u003e\n\u003ctd\u003e0.3 % time delay\u003cbr\u003e0.5 % input and measurement circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement error\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 % over the whole range with voltage variation\u003cbr\u003e0.05 %\/Â°C with temperature variation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 200 ms (in the event of a fault)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 500 MOhm 500 V DC IEC 60255-5\u003cbr\u003e\u0026gt; 500 MOhm 500 V DC IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e400 V IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating position\u003c\/td\u003e\n\u003ctd\u003eAny position without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, 1 x 0.5...1 x 4 mmÂ² AWG 20...AWG 11) solid without cable end\u003cbr\u003eScrew terminals, 2 x 0.5...2 x 2.5 mmÂ² AWG 20...AWG 14) solid without cable end\u003cbr\u003eScrew terminals, 1 x 0.2...1 x 2.5 mmÂ² AWG 24...AWG 12) flexible with cable end\u003cbr\u003eScrew terminals, 2 x 0.2...2 x 1.5 mmÂ² AWG 24...AWG 16) flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003e5.3â¦8.9 lbf.in (0.6â¦1 N.m) IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal signalling\u003c\/td\u003e\n\u003ctd\u003eLED (green) for power ON\u003cbr\u003eLED (yellow) for relay ON\u003cbr\u003eLED (yellow) for fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting support\u003c\/td\u003e\n\u003ctd\u003e35 mm symmetrical DIN rail conforming to IEC 60715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e100000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e30000000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating rate\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 360 operations\/hour full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-12 IEC 60947-5-1\u003cbr\u003eAC-13 IEC 60947-5-1\u003cbr\u003eAC-14 IEC 60947-5-1\u003cbr\u003eAC-15 IEC 60947-5-1\u003cbr\u003eDC-12 IEC 60947-5-1\u003cbr\u003eDC-13 IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability data\u003c\/td\u003e\n\u003ctd\u003eMTTFd = 399.5 years\u003cbr\u003eB10d = 360000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.29 lb(US) (0.13 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Type\u003c\/td\u003e\n\u003ctd\u003eWithout test button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840797888734,"sku":"RM35TF30-Sealed","price":277.23,"currency_code":"USD","in_stock":true},{"title":"Never Used Surplus","offer_id":46667373117662,"sku":"RM35TF30","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Used","offer_id":46667373183198,"sku":"RM35TF30-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_933c0a37-a3cf-4eb5-ad01-0a338d4f1c79.png?v=1753949011","url":"https:\/\/plc-direct.com\/products\/rm35tf30","provider":"PLC Direct","version":"1.0","type":"link"}